Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fine structure in the α decay of $^{179}$Hg and $^{177}$Au

Abstract The$$\upalpha $$ α -decay fine structure of$$^{179}$$ 179 Hg and$$^{177}$$ 177 Au was studied by means of decay spectroscopy. Two experiments were performed at the Accelerator Laboratory of the University of Jyväskylä (JYFL), Finland, utilizing the recoil separator RITU and a digital data acquisition system. The heavy-ion induced fusion-evaporation reactions$$^{82}_{36}$$ 36 82 Kr + $$^{100}_{44}$$ 44 100 Ru and$$^{88}_{38}$$ 38 88 Kr + $$^{92}_{42}$$ 42 92 Mo were used to produce the$$^{179}$$ 179 Hg and$$^{177}$$ 177 Au nuclei, respectively. Studying the evaporation residues (ER, recoils)-$$\alpha _1$$ α 1 -$$\alpha _2$$ α 2 correlations and$$\upalpha $$ α -$$\gamma $$ γ coincidences, a new$$\upalpha $$ α decay with E$$_\alpha $$ α = 6156(10) keV was observed from$$^{179}$$ 179 Hg. This decay populates the (9/2$$^-$$ - ) excited state at an excitation energy of 131.3(5) keV in$$^{175}$$ 175 Pt. The internal conversion coefficient for the 131.3(5) keV transition de-exciting this state was measured for the first time. Regarding the$$^{177}$$ 177 Au nucleus, a new$$\upalpha $$ α decay with E$$_\alpha $$ α = 5998(9) keV was observed to populate the 156.1(6) keV excited state in$$^{173}$$ 173 Ir. Two de-excitation paths were observed from this excited state. Moreover, a new 215.7(13) keV transition was observed to depopulate the 424.4(13) keV excited state in$$^{173}$$ 173 Ir. Properties of the$$^{179}$$ 179 Hg and$$^{177}$$ 177 Au$$\upalpha $$ α decays were examined in a framework of reduced widths and hindrance factors. For clarity and simplicity, the spin and parity assignments (e.g.$$J^{\pi }$$ J π ) are presented without brackets throughout the text.

Physics↗

Development of the Ultimate One-Dimensional Time to Explosion (UODTX) Apparatus

With recent advancements in experimental capabilities and worldwide improvement of digital data acquisition and control, there is sufficient justification to develop a new version of the One Dimensional Time to eXplosion (ODTX) system to allow for additional diagnostics and improved control to increase sample throughput and increase the adaptability of future experiments. The legacy ODTX system was designed to measure time to explosion (TTX) for a given temperature, which it does well, but it was not equipped to handle the recent experimental advances of Pressure-ODTX (PODTX) and Composition-ODTX (CODTX). PODTX involves fielding a pressure transducer as an additional diagnostic and applying arbitrary heating-profiles to the system anvils. CODTX furthers this concept by including in-situ gas-composition analysis via infrared (IR) absorption techniques with plans to extend CODTX to solid composition detection and in-situ mass spectrometry (MS). The legacy ODTX system was not built with these experiments in mind and performing them involves substantial modifications and downtime to the existing machine. Developing a standalone system that can perform all C/P/ODTX experiments and is adaptable to unconceived experiments would allow for the continued use of ODTX as a work-horse for Small Scale Safety Testing (SSST), but also provide a testbed for new explosive safety research. This system would ultimately be housed in the neighboring ODTX cell and would live at the High Explosive Application Facility (HEAF) until the end of its service life. HEAF, Chemistry, and Engineering would be the primary stakeholders for the system’s design as they all have experiments that they want to perform. Engineering would be responsible for the system development and would work closely with HEAF to ensure that the system is built with high explosive (HE) safety in mind. By the end of development and after product realization, HEAF/Chemistry would be the system owner, operator, and primary user. The proposed system design is highly influenced by the existing ODTX design. The system will have load frame to support the experiment, anvils to confine the explosive, and some means of applying confining pressure. The samples will be able to be heated and cooled through the confining the anvils. The biggest change from the legacy design is the ability to add diagnostics to the experiment as needed: thermocouples (TCs), resistance temperature detectors (RTDs), pressure transducers (PTs), infrared transmittance/absorbance (IR), mass spectrometry (MS), strain gages (SGs), photonic doppler velocimeter (PDV), as well as arbitrary 4-20 mV signals and +/- 10 VDC signals. The current design does not allow for flexibility in that respect and is hardwired with a few diagnostic channels. The onus will fall on designing a load frame that can support system modifications as well as a data acquisition system that can handle the multitude of signal types.

36 MATERIALS SCIENCE↗

Vibration-Based Sensor Design: A Grey-Box Approach

Knowledge of the internal structure of an object or device under investigation proceeds from the basic idea of constructing its dynamic behavioral relations governed by a set of differential/algebraic equations that characterize its response. These equations can be partial differential equations leading to finite element or finite difference relations requiring a complex numerical solution on a super computer or ordinary differential equations requiring sophisticated numerical integration techniques to obtain the desired solution. Discrete dynamic systems evolving from digitized data acquisition are typically captured by sampled-data (continuous-to-discrete) representations characterized by a set of difference equations specifying the underlying system dynamics. In any case, with a mathematical description in hand, Grey-Box modeling techniques have evolved, concerned with the estimation of model parameters embedded in a prescribed set of equations (the system) governing its behavior, while capturing the underlying physical phenomenology of the problem at hand.

97 MATHEMATICS AND COMPUTING↗

Manufacturing Management System Overview [Slides]

Vision: Institute a trusted manufacturing capability within the ALDWP Production Agency enabling digital product acceptance and access to digital manufacturing post-production activities. Mission: Establish a modern manufacturing infrastructure that ensures operator credentials, minimized human transcription errors, capable of managing all aspects of manufacturing including digital data acquisition, NCR resolution, and product acceptance, while providing an effective and intuitive user experience. Strategy: Constitute the modern manufacturing infrastructure to minimize risk and plant disruption while incrementally involving the capability.

42 ENGINEERING↗

Advanced Data Management for the Wastewater Industry

This information sheet discusses the technology pillar Advanced Data Management as a pathway toward improving wastewater infrastructure sustainability and resiliency. To supplement existing literature on current technologies and policies for improving resiliency at wastewater treatment plants (WWTPs), this document aims to accomplish the following: • Summarize key technologies such as Supervisory Control and Data Acquisition (SCADA), digital twins, and smart sensors • Summarize relevant cybersecurity measures and data management tools available for WW utilities • Summarize advances in sensing and monitoring technologies • Serve as a comprehensive (though not exhaustive) repository for data management for wastewater utilities The Advanced Management Technical Information Sheet should be viewed as a general guide to established best practices for the water and wastewater sector when considering implementing energy capture and energy- or process-efficient technologies. Further details are presented in the SWIFt Technology Information Sheet Series for accompanying Technology Pillars.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Petrophysical Analysis and Geographic Information System for San Juan Basin Tight Gas Reservoirs

The primary goal of this project is to increase the availability and ease of access to critical data on the Mesaverde and Dakota tight gas reservoirs of the San Juan Basin. Secondary goals include tuning well log interpretations through integration of core, water chemistry and production analysis data to help identify bypassed pay zones; increased knowledge of permeability ratios and how they affect well drainage and thus infill drilling plans; improved time-depth correlations through regional mapping of sonic logs; and improved understanding of the variability of formation waters within the basin through spatial analysis of water chemistry data. The project will collect, integrate, and analyze a variety of petrophysical and well data concerning the Mesaverde and Dakota reservoirs of the San Juan Basin, with particular emphasis on data available in the areas defined as tight gas areas for purpose of FERC. A relational, geo-referenced database (a geographic information system, or GIS) will be created to archive this data. The information will be analyzed using neural networks, kriging, and other statistical interpolation/extrapolation techniques to fine-tune regional well log interpretations, improve pay zone recognition from old logs or cased-hole logs, determine permeability ratios, and also to analyze water chemistries and compatibilities within the study area. This single-phase project will be accomplished through four major tasks: Data Collection, Data Integration, Data Analysis, and User Interface Design. Data will be extracted from existing databases as well as paper records, then cleaned and integrated into a single GIS database. Once the data warehouse is built, several methods of data analysis will be used both to improve pay zone recognition in single wells, and to extrapolate a variety of petrophysical properties on a regional basis. A user interface will provide tools to make the data and results of the study accessible and useful. The final deliverable for this project will be a web-based GIS providing data, interpretations, and user tools that will be accessible to anyone with Internet access. During this project, the following work has been performed: (1) Assimilation of most special core analysis data into a GIS database; (2) Inventorying of additional data, such as log images or LAS files that may exist for this area; (3) Analysis of geographic distribution of that data to pinpoint regional gaps in coverage; (4) Assessment of the data within both public and proprietary data sets to begin tuning of regional well logging analyses and improve payzone recognition; (5) Development of an integrated web and GIS interface for all the information collected in this effort, including data from northwest New Mexico; (6) Acquisition and digitization of logs to create LAS files for a subset of the wells in the special core analysis data set; and (7) Petrophysical analysis of the final set of well logs.

03 NATURAL GAS↗

Results of aerodynamic heat transfer tests of a 0.0175-scale model of the Rockwell International Space Shuttle Orbiter 139 (model number 22-0) in the NASA/Ames 3.5-foot hypersonic wind tunnel (test OH6)

The results of a hypersonic wind tunnel test program conducted using a 0.0175 scale thin-skin thermocouple model of the Space Shuttle Orbiter to obtain aerodynamic heat transfer data on the Orbiter under simulated reentry conditions were presented. The test program was conducted at a Mach number of 7.3 and a freestream Reynolds number ranging between 1.0 and 6.0 million/foot. The model was tested for angles of attack ranging between 10 deg and 30 deg and a sideslip angle of 0 deg. The model was constructed of 15-5 PH stainless steel with the instrumented areas machined to a nominal skin thickness of 0.030 in. The model instrumentation consisted of 288 iron-constantan thermocouples spot welded to the skin inner surface, but only 75 of these were used in this test program. A high-speed, analog-to-digital data acquisition system was used to record data on magnetic tape.

Dye, W. H.↗

Pulse width fluctuations in mode-locked Nd:YAG lasers

The experiment consisted of a flashlamp-pumped Nd:YAG laser rod in the Brewster-Brewster configuration, passively modelocked by a thick flowing dye in contact with the high reflectivity rear mirror. A single pulse was selected by a cylindrical-ring electrode Pockel's cell, and amplified by two Nd:YAG amplifiers. Calibrated photodiodes measured the total pulse energy at the fundamental frequency and the total pulse energy at the second harmonic frequency. The signals were monitored by a digital data acquisition system and displayed on a teletype printer.

Bechtel, J. H.↗

A performance evaluation of various coatings, substrate materials, and solar collector systems

An experimental apparatus was constructed and utilized in conjunction with both a solar simulator and actual sunlight to test and evaluate various solar panel coatings, panel designs, and scaled-down collector subsystems. Data were taken by an automatic digital data acquisition system and reduced and printed by a computer system. The solar collector test setup, data acquisition system, and data reduction and printout systems were considered to have operated very satisfactorily. Test data indicated that there is a practical or useful limit in scaling down beyond which scaled-down testing cannot produce results comparable to results of larger scale tests. Test data are presented as are schematics and pictures of test equipment and test hardware.

Dolan, F. J.↗

Preliminary demonstration of precision DSN clock synchronization by radio interferometry

A wideband digital data acquisition system has been developed to measure the clock offsets to the 10-ns accuracy required to facilitate three-way spacecraft ranging, to monitor the hydrogen maser frequency standard rates to 1 part in 10 to the forteenth power and to potentially reduce operational costs by replacing the current DSN operational time sync system.

Hurd, W. J.↗

Energy efficient face seal

Torque, face temperature, leakage, and wear of a flat face seal were compared with three coned face seals at pressures up to 2758 kPa and speeds up to 8000 rpm. Axial movement of the mating seal parts was recorded by a digital data acquisition system. The coning of the tungsten carbide primary ring ranged from .51 micro-m to 5.6 micro-m. The torque of the coned face seal balanced to 76.3% was an average 42% lower, the leakage eleven times higher, than that of the standard flat face seal. The reduction of the balance of the coned face seal to 51.3% resulted by decreasing the torque by an additional 44% and increasing leakage 12 to 230 times, depending on the seal shaft speed. No measurable wear was observed on the face of the coned seals.

Sehnal, J.↗

Satellite freeze forecast system

Provisions for back-up operations for the satellite freeze forecast system are discussed including software and hardware maintenance and DS/1000-1V linkage; troubleshooting; and digitized radar usage. The documentation developed; dissemination of data products via television and the IFAS computer network; data base management; predictive models; the installation of and progress towards the operational status of key stations; and digital data acquisition are also considered. The d addition of dew point temperature into the P-model is outlined.

Martsolf, J. D.↗

Analytical Ultrasonics in Materials Research and Testing

Research results in analytical ultrasonics for characterizing structural materials from metals and ceramics to composites are presented. General topics covered by the conference included: status and advances in analytical ultrasonics for characterizing material microstructures and mechanical properties; status and prospects for ultrasonic measurements of microdamage, degradation, and underlying morphological factors; status and problems in precision measurements of frequency-dependent velocity and attenuation for materials analysis; procedures and requirements for automated, digital signal acquisition, processing, analysis, and interpretation; incentives for analytical ultrasonics in materials research and materials processing, testing, and inspection; and examples of progress in ultrasonics for interrelating microstructure, mechanical properites, and dynamic response.

Vary, A.↗