Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Acousto-optic spectrometer for radio astronomy

A prototype acousto-optic spectrometer which uses a discrete bulk acoustic wave Itek Bragg cell, 5 mW Helium Neon laser, and a 1024 element Reticon charge coupled photodiode array is described. The analog signals from the photodiode array are digitized, added, and stored in a very high speed custom built multiplexer board which allows synchronous detection of weak signals to be performed. The experiment is controlled and the data are displayed and stored with an LSI-2 microcomputer system with dual floppy discs. The performance of the prototype acousto-optic spectrometer obtained from initial tests is reported.

Chin, G.↗

Hadamard transform imager and imaging spectrometer

An imager and a spectrometric imager, which achieve multiplexing by the use of binary optical encoding masks, have been built and tested. The masks are based on orthogonal, pseudorandom digital codes derived from Hadamard matrices. The spatial (and/or spectral) data are therefore obtained in the form of a Hadamard transform of the spatial (and/or spectral) scene. Computer algorithms are used to decode the data and reconstruct images of the original scene. The hardware, algorithms processing and display facility are described. A number of spatial and spatial/spectral images, obtained in the laboratory, are presented.

Swift, R. D.↗

A method for classification of multisource data using interval-valued probabilities and its application to HIRIS data

A method of classifying multisource data in remote sensing is presented. The proposed method considers each data source as an information source providing a body of evidence, represents statistical evidence by interval-valued probabilities, and uses Dempster's rule to integrate information based on multiple data source. The method is applied to the problems of ground-cover classification of multispectral data combined with digital terrain data such as elevation, slope, and aspect. Then this method is applied to simulated 201-band High Resolution Imaging Spectrometer (HIRIS) data by dividing the dimensionally huge data source into smaller and more manageable pieces based on the global statistical correlation information. It produces higher classification accuracy than the Maximum Likelihood (ML) classification method when the Hughes phenomenon is apparent.

Kim, H.↗

A method for classification of multisource data using interval-valued probabilities and its application to HIRIS data

A method of classifying multisource data in remote sensing is presented. The proposed method considers each data source as an information source providing a body of evidence, represents statistical evidence by interval-valued probabilities, and uses Dempster's rule to integrate information based on multiple data sources. The method is applied to the problems of ground-cover classification of multispectral data combined with digital terrain data such as elevation, slope, and aspect. Then this method is applied to simulated 201-band High Resolution Imaging Spectrometer (HIRIS) data by dividing the dimensionally huge data source into smaller and more manageable pieces based on the global statistical correlation information. It produces higher classification accuracy than the Maximum Likelihood (ML) classification method when the Hughes phenomenon is apparent.

Kim, H.↗

A summary of the test procedures and operational details of an ocean dumping pollution monitoring experiment conducted 7 October 1976

A remote sensor experiment was conducted at a sewage sludge dump site off the Delaware/Maryland coast. Two aircraft serving as remote sensor platforms flew over the dump site during a sludge dump. One aircraft carried a multispectral scanner and the other aircraft carried a rapid scanning spectrometer. Data from sea-truth stations were collected concurrent with overpasses of the aircraft. All sensors were operational and produced good digital data.

Hypes, W. D.↗

Determining experimentally induced variation in coniferous canopy chemistry with Airborne Imaging Spectrometer data

Experimental treatments in a Douglas-fir forest in NE New Mexico were carried out to determine whether differences in forest canopy chemistry could be detected using data from the Airborne Imaging Spectrometer (AIS-2). Experimental treatments consisted of nitrogen fertilizer additions, sawdust additions, and control plots. After AIS-2 data were collected, the digital number of a given pixel was extracted from each channel, yielding 128 values that were used to form a spectrum. Four spectra were extracted from each treatment plot. Multiple stepwise linear regressions between first and second difference transformations of AIS-2 spectra and the canopy characteristics of biomass, nitrogen concentration, and nitrogen content were performed. The results showed a coefficient of multiple determination of 0.71 between first-difference AIS-2 spectra and measured nitrogen concentration in foliage, indicating that it may be possible to predict nitrogen concentration in Douglas fir using AIS-2 spectra.

Swanberg, N. A.↗

Hard-X-Ray/Soft-Gamma-Ray Imaging Sensor Assembly for Astronomy

An improved sensor assembly has been developed for astronomical imaging at photon energies ranging from 1 to 100 keV. The assembly includes a thallium-doped cesium iodide scintillator divided into pixels and coupled to an array of high-gain avalanche photodiodes (APDs). Optionally, the array of APDs can be operated without the scintillator to detect photons at energies below 15 keV. The array of APDs is connected to compact electronic readout circuitry that includes, among other things, 64 independent channels for detection of photons in various energy ranges, up to a maximum energy of 100 keV, at a count rate up to 3 kHz. The readout signals are digitized and processed by imaging software that performs "on-the-fly" analysis. The sensor assembly has been integrated into an imaging spectrometer, along with a pair of coded apertures (Fresnel zone plates) that are used in conjunction with the pixel layout to implement a shadow-masking technique to obtain relatively high spatial resolution without having to use extremely small pixels. Angular resolutions of about 20 arc-seconds have been measured. Thus, for example, the imaging spectrometer can be used to (1) determine both the energy spectrum of a distant x-ray source and the angular deviation of the source from the nominal line of sight of an x-ray telescope in which the spectrometer is mounted or (2) study the spatial and temporal development of solar flares, repeating - ray bursters, and other phenomena that emit transient radiation in the hard-x-ray/soft- -ray region of the electromagnetic spectrum.

Myers, Richard A.↗

Optical Evaluation of DMDs with UV-Grade FS, Sapphire, MgF2 Windows and Reflectance of Bare Devices

Digital Micro-mirror Devices (DMDs) have been identified as an alternative to microshutter arrays for space-based multi-object spectrometers (MOS). Specifically, the MOS at the heart of a proposed Galactic Evolution Spectroscopic Explorer (GESE) that uses the DMD as a reprogrammable slit mask. Unfortunately, the protective borosilicate windows limit the use of DMDs in the UV and IR regimes, where the glass has insufficient throughput. In this work, we present our efforts to replace standard DMD windows with custom windows made from UV-grade fused silica, Low Absorption Optical Sapphire (LAOS) and magnesium fluoride. We present reflectance measurements of the antireflection coated windows and a reflectance study of the DMDs active area (window removed). Furthermore, we investigated the long-term stability of the DMD reflectance and recoating device with fresh Al coatings.

Quijada, Manuel A.↗

Imaging Spectrometer With Liquid-Crystal Tunable Filter

Imaging spectrometer constructed from charged-coupled-device video camera; liquid-crystal tunable filter (LCTF) placed in front of camera lens; and associated digital and analog control, signal-processing, and data-processing circuits. To enable operation of instrument in specific application for which designed (balloon flights in cold weather), camera and LCTF surrounded by electric heating pad. Total operating power, excluding that consumed by heating pad, 16 W. Instrument weighs 4.5 kg.

Chrien, Thomas G.↗

Development and evaluation of a Hadamard transform imaging spectrometer and a Hadamard transform thermal imager

A spectrometric imager and a thermal imager, which achieve multiplexing by the use of binary optical encoding masks, were developed. The masks are based on orthogonal, pseudorandom digital codes derived from Hadamard matrices. Spatial and/or spectral data is obtained in the form of a Hadamard transform of the spatial and/or spectral scene; computer algorithms are then used to decode the data and reconstruct images of the original scene. The hardware, algorithms and processing/display facility are described. A number of spatial and spatial/spectral images are presented. The achievement of a signal-to-noise improvement due to the signal multiplexing was also demonstrated. An analysis of the results indicates both the situations for which the multiplex advantage may be gained, and the limitations of the technique. A number of potential applications of the spectrometric imager are discussed.

Harwit, M.↗

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

International Symposium on Remote Sensing of Environment, 10th, University of Michigan, Ann Arbor, Mich., October 6-10, 1975, Proceedings. Volumes 1 & 2

Topics treated include the application of a Fourier transform spectrometer to infrared remote sensing, the performance optimization of a satellite-borne thematic mapper, a data handling system to be integrated with a digital airborne multispectral scanner, infrared thermography for micro- and mesometeorological measurements, satellite interrogated data collection platforms for river and flood forecasting and the automatic measurement of sea surface temperature from a GOES satellite. Solar and atmospheric effects on satellite imagery derived from aircraft reflectance measurements, methods for determining haze levels from multispectral scanner data, restoration of Landsat images by discrete two-dimensional deconvolution and the automatic classification of aircraft and satellite multispectral images using mixed integer programming are also discussed. Individual items are announced in this issue.

Source record↗

Analysis of hyper-spectral AVIRIS image data over a mixed-conifer forest in Maine

An introduction to some of the potential uses of hyperspectral data for ecosystem analysis is presented. The examples given are derived from a digital dataset acquired over a sub-boreal forest in central Maine in 1990 by the NASA-JPL Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) instrument gathers data from 400 to 2500 nm in 224 channels at bandwidths of approximately 10 nm. As a preview to the uses of the hyperspectral data, several products from this dataset were extracted. They range from the traditional false color composite made from simulated Thematic Mapper bands and the well known normalized difference vegetation index to much more exotic products such as fractions of vegetation, soil and shade based on linear spectral mixing models and estimates of the leaf water content at the landscape level derived using spectrum-matching techniques. Our research and that of many others indicates that the hyperspectral datasets carry much important information which is only beginning to be understood. This analysis gives an initial indication of the utility of hyperspectral data. Much work still remains to be done in algorithm development and in understanding the physics behind the complex information signal carried in the hyperspectral datasets. This work must be carried out to provide the fullest science support for high spectral resolution data to be acquired by many of the instruments to be launched as part of the Earth Observing System program in the mid-1990's.

Lawrence, William T.↗

Digital decorrelator saves time and expense in acoustic testing of structures

Instantaneous signals from coherent random sound field are summed and time delayed to avoid introducing vectorial addition errors. Resultant statistically independent signals are applied to spectrometer. Displayed sound pressure level is proportional to square root of sum of squares of sound pressure levels taken over frequency range of interest.

Nakich, R. B.↗

Development of a high-speed H-alpha camera system for the observation of rapid fluctuations in solar flares

A solid-state digital camera was developed for obtaining H alpha images of solar flares with 0.1 s time resolution. Beginning in the summer of 1988, this system will be operated in conjunction with SMM's hard X-ray burst spectrometer (HXRBS). Important electron time-of-flight effects that are crucial for determining the flare energy release processes should be detectable with these combined H alpha and hard X-ray observations. Charge-injection device (CID) cameras provide 128 x 128 pixel images simultaneously in the H alpha blue wing, line center, and red wing, or other wavelength of interest. The data recording system employs a microprocessor-controlled, electronic interface between each camera and a digital processor board that encodes the data into a serial bitstream for continuous recording by a standard video cassette recorder. Only a small fraction of the data will be permanently archived through utilization of a direct memory access interface onto a VAX-750 computer. In addition to correlations with hard X-ray data, observations from the high speed H alpha camera will also be correlated and optical and microwave data and data from future MAX 1991 campaigns. Whether the recorded optical flashes are simultaneous with X-ray peaks to within 0.1 s, are delayed by tenths of seconds or are even undetectable, the results will have implications on the validity of both thermal and nonthermal models of hard X-ray production.

Kiplinger, Alan L.↗

Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers

Here, in this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9–1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ~30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Airy light-sheet Raman imaging

Light-sheet fluorescence microscopy has greatly improved the speed and overall photostability of optically sectioning cellular and multi-cellular specimens. Similar gains have also been conferred by light-sheet Raman imaging; these schemes, however, rely on diffraction limited Gaussian beams that hinder the uniformity and size of the imaging field-of-view, and, as such, the resulting throughput rates. Here, we demonstrate that a digitally scanned Airy beam increases the Raman imaging throughput rates by more than an order of magnitude than conventional diffraction-limited beams. Overall, this, spectrometer-less, approach enabled 3D imaging of microparticles with high contrast and 1 µm axial resolution at 300 msec integration times per plane and orders of magnitude lower irradiation density than coherent Raman imaging schemes. We detail the apparatus and its performance, as well as its compatibility with fluorescence light-sheet and quantitative-phase imaging towards rapid and low phototoxicity multimodal imaging.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, December 2012

The topics include: Pattern Generator for Bench Test of Digital Boards; 670-GHz Down- and Up-Converting HEMT-Based Mixers; Lidar Electro-Optic Beam Switch with a Liquid Crystal Variable Retarder; Feedback Augmented Sub-Ranging (FASR) Quantizer; Real-Time Distributed Embedded Oscillator Operating Frequency Monitoring; Software Modules for the Proximity-1 Space Link Interleaved Time Synchronization (PITS) Protocol; Description and User Instructions for the Quaternion to Orbit v3 Software; AdapChem; Mars Relay Lander and Orbiter Overflight Profile Estimation; Extended Testability Analysis Tool; Interactive 3D Mars Visualization; Rapid Diagnostics of Onboard Sequences; MER Telemetry Processor; pyam: Python Implementation of YaM; Process for Patterning Indium for Bump Bonding; Archway for Radiation and Micrometeorite Occurrence Resistance; 4D Light Field Imaging System Using Programmable Aperture; Device and Container for Reheating and Sterilization; Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources; Membrane Shell Reflector Segment Antenna; High-Speed Transport of Fluid Drops and Solid Particles via Surface Acoustic Waves; Compact Autonomous Hemispheric Vision System; A Distributive, Non-Destructive, Real-Time Approach to Snowpack Monitoring; Wideband Single-Crystal Transducer for Bone Characterization; Numerical Simulation of Rocket Exhaust Interaction With Lunar Soil; Motion Imagery and Robotics Application (MIRA): Standards-Based Robotics; Particle Filtering for Model-Based Anomaly Detection in Sensor Networks; Ka-band Digitally Beamformed Airborne Radar Using SweepSAR Technique; Composite With In Situ Plenums; Multi-Beam Approach for Accelerating Alignment and Calibration of HyspIRI-Like Imaging Spectrometers; JWST Lifting System; Next-Generation Tumbleweed Rover; Pneumatic System for Concentration of Micrometer-Size Lunar Soil.

Source record↗