Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct Current (DC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Josephson dynamics in two-dimensional ring-shaped condensates

We investigate Josephson transport in a fully closed, two-dimensional superfluid circuit formed by a ring-shaped 87 Rb Bose-Einstein condensate that contains two optical barriers acting as movable weak links. Translating these barriers at controlled speeds imposes a steady bias current, enabling direct mapping of the current-chemical-potential (𝐼−Δ⁢𝜇) characteristics. For narrow junctions (𝑤 ≈ 1µ⁢m), the circuit exhibits a pronounced dc branch that terminates at a critical current 𝐼 𝑐 = 9⁢(1) × 10 3 s −1 ; above this threshold, the system switches to an ac, resistive regime. Classical-field simulations that include the moving barriers quantitatively reproduce both the nonlinear 𝐼−Δ⁢𝜇 curve and the measured 𝐼 𝑐 , validating the underlying microscopic picture. Analysis of the ensuing phase dynamics shows that dissipation is mediated by the nucleation and traversal of vortex-antivortex pairs through the junctions, while the bulk condensate remains globally phase locked—direct evidence of the ring's topological constraint enforcing quantized circulation. These results establish a cold-atom analog of a superconducting quantum interference device in which Josephson dynamics can be resolved at the single-vortex level, providing a versatile platform for atomtronic circuit elements, nonreciprocal Josephson devices, and on-chip Sagnac interferometers for multiaxis rotation sensing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Limiting Current in Nanostructured Block Copolymer Electrolytes

The next-generation electrolytes for lithium batteries must be able to conduct ions at sufficiently high current densities; yet this regime is rarely studied directly. The limiting current density of an electrolyte quantifies the highest possible rate of ion transport under an applied dc potential. Herein, we report on the limiting current density in twelve nanostructured polystyrene-block-poly(ethylene oxide) (PS-b-PEO, or SEO) copolymer electrolytes. We find that the limiting current at a given salt concentration increases systematically with increasing volume fraction of the PEO block (φ EO ). In contrast, the effective-medium theory, commonly used to analyze conductivity in block copolymer electrolytes, predicts that limiting current is independent of φ EO . To resolve this conundrum, the ionic conductivity, the mutual diffusion coefficient of the salt, and the steady-state current fraction of the block copolymer electrolytes were measured. These measurements enable predictions of limiting current with no adjustable parameters using the concentrated solution theory. We found quantitative agreement between experimentally measured limiting current densities and predictions based on the concentrated solution theory. This work sheds light on how to reliably measure and predict limiting current density in composite electrolytes.

25 ENERGY STORAGE↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Comparison of 1D and 2D particle-in-cell simulations for DC magnetron sputtering discharges

One-dimensional and two-dimensional particle-in-cell (PIC)/Monte Carlo collision simulations are performed for a balanced direct current magnetron sputtering (DCMS) discharge. The plasma parameters obtained by both simulations above the target racetrack share similar features and magnitudes under similar discharge intensities, i.e., similar local discharge current densities. The commonly observed high-energy tail of electron energy distribution in DCMS discharges is reproduced in both simulations. Additionally, the accuracy and applicability of using onedimensional simulations to qualitatively investigate the characteristics of balanced DCMS discharge are confirmed. In terms of capturing the key physical mechanisms in DCMS, one-dimensional PIC simulation is an efficient method, which could largely alleviate the computational expense and preserve the physical fidelity of modeling results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scalable Hybrid Large-Scale dc-ac Grid Analysis Methods (Phase II)

The goals of the project included the identification and evaluation of a voltage source converter multiterminal high-voltage direct current (VSC-MTdc) system architecture suitable for a high amount of power transfer through long transmission lines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Layout Design of a GaN HEMTs-Based High-Power High-Efficiency Three-Level ANPC Inverter for 800 V DC Bus System

Multiple commutation paths exist for switching devices in a three-level active neutral point clamped (3L-ANPC) inverter operation based on the selected switching state and current direction. In addition, the capacitive coupling path of the nonswitching device is a key design aspect for enabling high voltage and high current operation of gallium nitride (GaN) switches in 3L-ANPC topology. A comprehensive study of the switching transient events of inner, outer, and clamping devices of 3L-ANPC is presented in this article. The commutation mechanisms for worst-case transient voltage overshoots (TVOs) are identified. A simplified equivalent circuit model is presented to determine the design criteria for the power layout structure's parasitic inductances. A power layout strategy satisfying the design criteria is then proposed using an insulated metal substrate power printed circuit board (PCB) to enable efficient high-power operation. The proposed design minimizes the commutation and capacitive coupling path inductances to 6 nH and 11.5 nH, respectively. This enables the fast switching operation of GaN HEMTs at 800 V dc, 36 A with a low TVO of 31% verified through experimental three-level double pulse test results. Experimental evaluation of a three-phase 3L-ANPC hardware prototype based on the proposed power layout shows 99% efficiency at 800 V, 9.5 kVA and 50 kHz switching frequency. The proposed design achieves a low case-to-ambient thermal resistance of 2.3 °C/W.

42 ENGINEERING↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

ARC-SAFE: Accelerated Response semiconducting Contactors and Surge Attenuation For DC Electrical systems (Final Scientific/Technical Report)

The landscape of power transmission and distribution is quickly evolving as more power conversion is done through power electronics and transmitted or distributed at medium voltage direct current (MVDC). As power electronics tend to store less energy and be less resilient to faults than conventional power transformers, a reliable and fast protection against faults is critical to protect power electronics (PE) based infrastructure, especially for medium- and high-voltage applications. This motivates the development of PE based protection circuits to replace slower contemporary electromechanical breakers. In this project a novel PE based MVDC circuit breaker is developed; the new design is comprised of 1) a normally-on leg made of commercially-available, cascaded SiC junction field effect transistors (JFETs) with a passive balancing network, and 2) a normally-off leg based on an optically-triggered gallium nitride (GaN) photoconductive semiconductor switch (PCSS). The normally-off leg was designed to be quickly turned on, to divert current to an auxiliary dissipative circuit, as the normally-on leg is turned off. This approach, using solid-state devices, was selected for a high-performance, fast-switching operation for the DC circuit breaker as compared to approaches that use slower mechanical switches. To be practical, the circuit breaker must have low conduction loss (low Ron) in the normally-on leg and fast coordinated triggering of the normally-off leg to avoid damage from inductive flyback, which could be considerable for long lengths of cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electronic assembly with a direct current bus connection

A folded outer tab comprises a first outer dielectric layer and a second outer dielectric layer that contact or overlie an outer terminal, where the outer terminal is associated with a first polarity of the DC bus. A bent inner tab comprises a first inner dielectric layer and a second inner dielectric layer that contact or overlie an inner terminal, where the inner terminal is associated with a second polarity of the DC bus that is opposite the first polarity. The folded outer tab and the bent inner tab comprise electrically conductive faces, of opposite polarities, formed of exposed portions of the outer terminal and the inner terminal.

Schmit, Christopher J.↗

Precision current regulator for NMR electromagnets

When using electromagnets or non-persistent superconducting magnets, the field stability can be directly proportional to the current stability. We present in this report a simple design for a current regulator based upon a high-precision, dc-dc fluxgate transformer. The output current and NMR frequency are stabilized by about a factor of 50, over times of order one hour. The method can be applied to essentially any current supply.

59 BASIC BIOLOGICAL SCIENCES↗

Ultraviolet (UV) light emitting device (LED) driven photocathode

An apparatus includes an electromechanical x-ray generator (MEXRAY) configured to charged capacitors using a small, high-voltage direct current. The apparatus also includes an ultraviolet (UV) light emitting diode (LED) driven photocathode device configured to control/modulate an electron dose rate of the MEXRAY or other vacuum DC, source.

Watson, Scott Avery↗

Heterogeneous Integration Technologies for High-temperature, High-density, Low-profile Power Modules of Wide Bandgap Devices in Electric Drive Applications (Final Technical Report)

The goal of this project is to develop packaging technologies for making high-temperature, high-density, and low-profile wide-bandgap (WBG) power electronics modules for electric drives. These modules are aimed at enabling the DOE’s University Consortium to reach its 2025 inverter targets of ≥ 100 kW/L and ≤ 2.7 $/kW. The specific objectives are to: design and fabricate SiC half-bridge power modules with double-sided cooling and parasitic inductances < 5 nH, heat flux density > 400 W/cm 2 , and working junction temperature of 200 o C; design, fabricate, and deliver a gate driver with double-sided cooled modules for the construction of a 100 kW/L inverter at Oak Ridge National Lab; and design and prototype intelligent gate drivers with integrated current sensor and a low-profile DC-DC power supply with air-core transformer for testing power modules at 200 o C junction temperature. We followed an iterative technical approach of design, simulation, fabrication, and testing of various versions of modules, current sensors, and power supply. The state-of-the-art silicon carbide devices rated at 1.2 kV and 149 A were packaged by sintered-silver bonding on an aluminum nitride direct-bond-copper substrate for high thermal conductivity, high working temperature, and high joint reliability. Porous silver posts were used to interconnect the device’s source pads to the other direct-bond-copper substrate for low mechanical stresses, ease of manufacturing, and double-sided cooling. A current sensor based on package parasitic inductance was developed to measure switching current. A dynamic feedback scheme was developed to compensate the effect of parasitic resistance and temperature variation. A constant-current class-E dc-dc converter with air-core transformer was developed. Air-core transformer was used due to the unavailability of magnetic core at high temperatures. Gate driver and power supply were integrated with the double-side cooled, high temperature SiC power modules for testing the modules at 200 o C junction temperature. Double-pulse and continuous testing of the integrated technologies validated the design and fabrication of the three component technologies. Throughout the project, we overcame the challenge for design verification caused by low prototyping yield, which then helped train the graduate students, the future workforce, to learn the engineering know-how for low-cost manufacturing of reliable products. Below is a summary of the major accomplishments of this project: development of a prototyping process for fabricating double-side cooled (1200 V, 149 A) SiC phase-leg modules capable of working to 200 o C Tj; simulation and experimental verification of the improvement of thermo-mechanical reliability of the double-side cooled SiC phase-leg module by using rigid encapsulant; design and experimental validation of a current sensor based on package parasitic inductance and a compensation solution for eliminating the effect of parasitic resistance; design and experimental validation of a low-profile power supply with six-output air-core transformer for gate driver; functional demonstration of a SiC phase-leg module integrated with its gate driver, current sensor, and an air-core power supply at 200 o C Tj in a double-pulse switching test setup and Buck converter continuous test setup; successful completion of six PhD and two MS students who are or will work at Apple Inc., Tesla Inc., Wolfspeed Inc., Microchip Inc., Monolithic Power Systems Inc., and LG Magna Inc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Antiferromagnetic memory storage devices from magnetic transition metal dichalcogenides

Switchable antiferromagnetic (AFM) memory devices are provided based on magnetically intercalated transition metal dichalcogenides (TMDs) of the form AxMC2, where A is a magnetic element of stoichiometry x between 0 and 1, M is a transition metal of stoichiometry 1, and C is a chalcogen of stoichiometry 2. Memory storage is achieved by fabricating these materials into crosses of two or more bars and driving DC current pulses along the bars to rotate the AFM order to a fixed angle with respect to the current pulse. Application of current pulses along different bars can switch the AFM order between multiple directions. Standard resistance measurements can detect the orientation of the AFM order as high or low resistance states. The state of the device can be set by the input current pulses, and read-out by the resistance measurement, forming a non-volatile, AFM memory storage bit.

Analytis, James G.↗

Effect of net direct current on the properties of radio frequency sheaths: simulation and cross-code comparison

In order to understand, predict and control ion cyclotron range of frequency (ICRF) interactions with tokamak scrape-off layer plasmas, computational tools which can model radio frequency (RF) sheaths are needed. In particular, models for the effective surface impedance and DC rectified sheath potentials may be coupled with full wave RF simulation codes to predict self-consistent wave fields near surfaces and the resulting power dissipation and plasma-material interactions from ion sputtering. In this study, previous work assuming zero net DC current flow through the sheath is generalized to allow the surface to collect net positive or negative current, as is often observed in experiments. The waveforms, DC potential and RF admittance are investigated by means of analytical theory, nonlinear fluid and particle-in-cell (PIC) codes. Cross-code comparisons provide detailed model verification and elucidate the roles of ion and electron kinetics. When the sheath draws negative (positive) DC current, the voltage rectification is reduced (increased) compared with the zero-current case, and the magnitude of both the real and imaginary parts of the admittance are increased (reduced). In conclusion, a previous four-input parametrization of the sheath rectification and admittance properties is generalized to include a fifth parameter describing the DC sheath current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗