Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Continuous soil temperature measurements from 2019-10-4 to 2020-10-4, Teller road Mile 27, Seward Peninsula, Alaska

The dataset contains depth-resolved soil temperature measured at 45 discrete locations in a watershed located along the Nome-Teller road at Mile 27 in Seward Peninsula, Alaska. The dataset was generated to understand the local heterogeneity of soil thermal dynamics and their controls in a discontinuous permafrost region. At each location, temperatures were measured by a distributed temperature profiling probe designed based on Dafflon et al (2022). The dataset includes a description of the probe locations in the "Probe_locations.csv" file and the 45 data files (Soil_temperatures_*.csv). Metadata files include data descriptions (_dd.csv) for tabular data. All included files are listed and described in NGA513_flmd.csv.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

NRC Multiphysics Analysis Capability Deployment (FY2021--Part 1)

This report details progress and activities of Idaho National Laboratory (INL) on the Nuclear Regulatory Commission (NRC) project “Development and Modeling Support for Advanced Non-Light Water Reactors.” The tasks completed for this report are as follows: First, Task 1d: The net radiation transfer method was implemented into MOOSE for modeling reactor cavity cooling system geometries. RCCS models for two experiments were created: (1) Natural Convection Shutdown Heat Removal Test Facility (NSTF) experiment R022, and (2) HTTR VCS mockup. For validation, computed temperature distributions were compared to measured temperatures. Next, Task 4c: An algorithm for computing the pebble bed reactor equilibrium core isotopic com-position was developed and an initial version is implemented into the reactor multi-physics code Griffin. Initial results for a simplified axisymmetric pebble bed reactor are presented. Finally, Task 7: generation of a reference plant model for molten salt cooled pebble bed reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measuring thermal profiles in high explosives using neural networks

We present a new method for calculating the temperature profile of high explosive (HE) material using a Convolutional Neural Network (CNN). To train/test the CNN, we have developed a hybrid experiment/simulation method for collecting acoustic and temperature data. We experimentally heat cylindrical containers of HE material until detonation/deflagration, where we continuously measure the acoustic bursts through the HE using multiple acoustic transducers lined around the exterior container circumference. However, measuring the temperature profile in the HE in an experiment would require inserting a large number of thermal probes, which would disrupt the heating process. Thus, we use two thermal probes, one at the HE center and one at the wall. We then use numerical simulation of the heating process to calculate the temperature distribution and correct the simulated temperatures based on the experimental center and wall temperatures. We calculate temperature errors on the order of 15 °C, which is ~12% of the range of temperatures in the experiment. We also investigate how the algorithm’s accuracy is affected by the number of acoustic receivers used to collect each measurement and the resolution of the temperature prediction. This work provides a means of assessing the safety status of HE material, which cannot be achieved using existing temperature measurement methods. In addition, it has implications for a range of other applications where internal temperature profile measurements would provide critical information. These applications include detecting chemical reactions, observing thermodynamic processes such as combustion, monitoring metal or plastic casting, determining the energy density in thermal storage capsules, and identifying abnormal battery operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Code Benchmark of Depressurized Conduction Cooldown Transient in the High Temperature Test Facility

This paper presents results from modeling of a depressurized conduction cooldown (DCC) transient at the High Temperature Test Facility (HTTF) as part of the OECD-NEA Thermal Hydraulics Code Validation Benchmark for High-Temperature Gas-Cooled Reactors using HTTF Data . This paper briefly describes the benchmark and the models being used. It then presents a comparison of steady state and transient results based on the Problem 2 Exercise 1A and 1B definitions. We compare block and helium temperature distributions, mass flow distribution, and energy balance in steady state. All models show comparable mass flow distributions and energy balances. The temperatures within the core and outer regions are comparable in all models too, but inner reflector temperatures can vary significantly. Despite that, we find that the models are in good agreement for the full-power steady state. In the DCC, we look at block temperature at the core midplane and RCCS water exit temperature. The INL and ANL models are found to be in excellent agreement with one another on block temperature over time, while the agreement when the KAERI and NRG models are added into consideration is good. Differences in the transient heat removal from the RCCS cause the differences in block temperature over time in these models. The CNL models show similar trends to the INL, ANL, KAERI, and NRG models, but the temperatures are high because the volumes used in calculating the average temperature include the heater rods in the CNL models only. The HUN-REN model shows results that suggest significantly lower heat removal in the RCCS which merit further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode↗

Distributed Fiber Optic Sensing for in-well hydraulic fracture monitoring

This study presents the results from in-well hydraulic fracture monitoring within a horizontal well in an unconventional reservoir utilizing Distributed Fiber Optic Sensing (DFOS). An in-house-developed Brillouin-based Distributed Strain Sensing (DSS) interrogator was deployed to obtain strain measurements, complemented by a commercial Raman-based Distributed Temperature Sensing (DTS) interrogator for temperature measurements and a commercial Rayleigh-based Low-Frequency Distributed Acoustic Sensing (LF-DAS) interrogator for strain-rate measurements. Examined over a ten-day period, the spatio-temporal distribution of temperature-compensated strain obtained from DSS and DTS revealed distinct signatures of the multi-stage hydraulic fracturing process. These signatures were analyzed with respect to fracture width growth and closure, residual strain effects, and fracture conductivity near the wellbore. Fracture widths within the fracture zone were estimated for individual stages. The findings were assessed with LF-DAS measurements for further evaluation. This work integrates DFOS-measured strain, temperature, and strain-rate data for monitoring in-well hydraulic fracturing, with the goal of supporting future studies in interpreting DFOS measurements for improved understanding of hydraulic fracturing in unconventional reservoirs.

58 GEOSCIENCES↗

Robust Carbon Dioxide Plume Imaging Using Joint Tomographic Inversion of Seismic Onset Time and Distributed Pressure and Temperature Measurements (Final Report)

We develop and demonstrate rapid and cost-effective methodologies for spatiotemporal tracking of CO2 plumes during geologic sequestration using joint inversion of seismic data and distributed pressure and temperature measurements. Key elements of our methodology are: (a) a computationally efficient approach to pressure and temperature propagation, (b) analysis of time lapse seismic data using a novel ‘seismic onset time’ approach to detect fluid front propagation, and (c) data assimilation and uncertainty assessment via joint inversion of pressure, temperature and time lapse seismic data, and (d) validating the numerical tomographic inversion using a CO2 injection demonstration projects, specifically data collected from the from the Petra Nova Parish Holdings CCUS project in the West Ranch Field, Texas and the Chester-16 reef CO2 injection site in Northern Michigan which is part of the DOE Midwestern Carbon Sequestration Project. The research team is led by Texas A&M University and includes Battelle as a subcontractor with support from Shell, Anadarko, Chevron and JX Nippon. A carbon dioxide (CO2) water-alternating-gas (WAG) pilot was conducted to gain insights into tertiary oil recovery potential via CO2 flood in the West Ranch Field as part of the Petra Nova project, the world’s largest post-combustion CO2 capture and utilization initiative. With a fluvial formation geology and large contrasts in permeability, this is a challenging and novel application of CO2 enhanced oil recovery (EOR). We build a predictive dynamic model of the subsurface that incorporates the multiphase and compositional data acquired during the pilot operation. The calibrated model is used for the carbon dioxide plume imaging. The study began with an initialization of the pilot sector model extracted from a calibrated full-field model. The pilot model calibration follows a two-step hierarchical workflow. First, we performed a large-scale update of the permeability distribution by integrating available bottomhole pressure and multiphase production data. In the second step, local permeability field is fine-tuned using a streamline-based method to match CO2 breakthrough times at the producers. The predictive capability of the calibrated model was verified through two blind validation tests: (1) the model showed good agreement with saturation logs acquired at two observation wells; and (2) the model reproduced the CO2 recovery as a fraction of the injected CO2. The use of seismic onset times has shown great promise for integrating near-continuous seismic surveys for updating geologic models. In this study, we analyze the impact of seismic survey frequency on the onset time approach aiming to extend the application of onset time to infrequent seismic surveys. In addition, we quantitatively examine the nonlinearity of the onset time method and compare it to the commonly used amplitude inversion method. We carry out a sensitivity analysis of seismic survey frequency based on the complete seismic survey data (over 175 surveys) of steam injection in a heavy oil reservoir (Peace River Unit) in Canada. Our results show that an adequate onset time map can be obtained from the infrequent seismic surveys by interpolation between seismic surveys as long as there is no change in the dominant underlying physics between the successive surveys. The study also shows that nonlinearity of the onset time method can be -smaller than that of the amplitude inversion method by several orders of magnitude. Application to the Brugge benchmark case shows that the onset time method obtains comparable permeability update as the traditional seismic amplitude inversion method with faster computation and improved convergence characteristics. We extend the streamline-based data integration approach to incorporate distributed temperature sensor (DTS) data using the concept of thermal tracer travel time. Then, a hierarchical workflow composed of evolutionary and streamline methods is employed to jointly history match the DTS and pressure data. Finally, CO2 saturation and streamline maps are used to visualize the CO2 plume movement during the sequestration process. The hierarchical workflow is applied to a carbon sequestration project in a carbonate reef reservoir within the Northern Niagaran Pinnacle Reef Trend in Michigan, USA. The monitoring data set consists of distributed temperature sensing (DTS) data acquired at the injection well and a monitoring well, flowing bottom-hole pressure data at the injection well, and time-lapse pressure measurements at several locations along the monitoring well. The history matching results indicate that the CO2 movement is mostly restricted to the intended zones of injection which is consistent with an independent warm-back analysis of the temperature data. In addition to employing simulation models and inverse methods for CO2 plume imaging, we also initialized a data-driven technology for detecting inter-well connectivity based on production and pressure data. Our machine-learning framework is built on the statistical recurrent unit (SRU) model and interprets well-based injection/production data into inter-well connectivity without relying on a geologic model. We test it on synthetic and field-scale CO2 EOR projects utilizing the water-alternating-gas (WAG) process. The validation of the proposed data-driven inter-well connectivity assessment is performed using synthetic data from simulation models where inter-well connectivity can be easily measured using the streamline-based flux allocation. The SRU model is shown to offer excellent prediction performance on the synthetic case. Despite significant measurement noise and frequent well shut-ins imposed in the field-scale case, the SRU model offers good prediction accuracy, the overall relative error of the phase production rates at most producers ranges from 10% to 30%. It is shown that the dominant connections identified by the data-driven method and streamline method are in close agreement. Texas A&M University, the lead organization in the project, was primarily responsible for the development of tomographic approaches for CO2 plume mapping in conjunction with distributed pressure, temperature and seismic onset time data. Battelle, as a subcontractor, was primarily responsible for the development of analytical and empirical methods for analyzing transient injection rate and pressure data from point/line sources such as injection and monitoring wells. An additional area of emphasis for Battelle was the use of machine learning for such tasks as inferring reservoir connectivity information from injection-production data, and identifying variable importance for machine learning-based proxy models developed from full-physics simulations. The two organizations also collaborated on the application of the tomographic inversion methodology for a field data set.

02 PETROLEUM↗

Evaluation of temperature changes in a cell culture plate well with absorbing walls containing a 3D model of tumour spheroid under irradiation in the optical range

The temperature conditions for photodynamic therapy of the culture of tumour cells organised in 3D spheroids are studied. The spheroids are placed in the cell culture medium in the well of a special cell culture plate with absorbing walls. A mathematical model is presented that describes the temperature distribution in a well with a cell culture plate heated by optical radiation. It is shown that the temperature in the well volume is not uniformly distributed, and the temperature on the well surface can differ significantly from the temperature in its volume. (laser medicine)

60 APPLIED LIFE SCIENCES↗

Thermal Behavior During the Selective Laser Melting Process of Ti-6Al-4V Powder in the Point Exposure Scan Pattern

Currently, there are two main scan patterns, including the continuous exposure scan pattern and the point exposure scan pattern, during the selective laser melting (SLM) process. The point exposure scan pattern allows a three-dimensional (3-D) printer to build finer detail features as a static molten pool that is more stable than a dynamic one. However, there has been limited theoretical research on the thermal behavior characteristics during the process in the point exposure scan pattern. Therefore, in this study, the simulation of thermal behavior during SLM of Ti-6Al-4V powder in the point exposure scan pattern was performed. The temperature evolution behavior of different positions and the effects of exposure time on the temperature evolution behavior of different positions, temperature distributions, and dimensions of the molten pool were investigated. The results showed that the direct exposure position and unexposed position had significantly different temperature evolution behaviors under a given condition, and the changed exposure time had the greatest influence on the direct exposure position compared with unexposed position. Moreover, the thermal accumulation effect of a former exposure point on a later one decreased with increasing exposure time. In addition, with the increase of exposure time, the maximum temperature of the molten pool was enhanced and the surface morphology of the molten pool changed from an approximate ellipse to an approximate circle. Besides, the molten pool dimensions were found to increase with exposure time, which indicated that the exposure time played an important role in the stability of the molten pool and the metallurgical bonding in the process. Furthermore, the dimensions of the molten pool and metallurgical bonding in the cross-sectional view were obtained through experiments. Good agreement was obtained when comparing the simulated results with the experimental ones.

36 MATERIALS SCIENCE↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring thermal state in mixed immersive virtual environments

Combining immersive virtual environment (IVE) with a controlled environment is a potential solution for analyzing human thermal experience during building design. Existing studies in this field have not adequately analyzed scenarios involving stabilized comfortable and uncomfortable temperature conditions using both thermal state votes and physiological responses, or the influence of the seasons. By combining IVE with a climate chamber, called mixed IVE (MIVE) in this study, experiments were conducted to test the hypothesis that participants' virtual experience did not significantly alter their thermal experience compared to their in-situ experience. Response variables were the control temperature distribution, the thermal state vote (at temperature steps 18.3 °C, 23.8 °C, and 29.4 °C), and physiological responses (heart rate and skin temperature). The results show that the first two response variables were not significantly different between the MIVE and in-situ settings (except for one case). Due to the heat development of the head mounted display device, the mean forehead skin temperature in the MIVE experiments was significantly higher than that in the in-situ experiments in most cases. Furthermore, such difference in skin temperature did not seem to affect general thermal state votes. In addition, significant skin temperature differences at some locations were also observed between the MIVE and in-situ settings.

42 ENGINEERING↗

Application of a Physics-Informed Convolutional Neural Network for Monitoring the Temperature Fields in High-Temperature Gas Reactors

Here, this work presents current advances in applying a physics-informed convolutional neural network (CNN) to evaluate temperature distributions in advanced reactors. Our goal is to demonstrate that the CNN can reconstruct temperature fields within the solid region of a prismatic fuel assembly in a high-temperature gas reactor (HTGR) with sensor data available in only a few cooling channels. Before that, we showcase the superior performance of the physics-informed CNN in comparison to a purely data-driven multilayer perceptron (MLP), considering a canonical heated channel setup. This analysis shows the advantages of our approach and justifies its choice. The datasets employed here are obtained upon numerical simulations performed with codes under the Nuclear Energy Advanced Modeling and Simulation program. This work is important, as industry experience indicates that the assembly material in HTGR concepts is prone to large thermal-mechanical loads nearing operational limits. This makes it crucial to characterize peak temperatures and their distributions near hot spots. Modern thermocouples are unreliable in these types of harsh environments because of the high neutron fluxes and elevated temperatures involved. The CNN-based field reconstruction represents an attractive solution, enabling sensor arrays in less aggressive locations and augmenting indirect predictions for less accessible regions. The results show that the CNN reduces prediction errors by orders of magnitude in comparison to the MLP, considering the simple yet well-representative heated channel case. In the case of the HTGR fuel assembly, the CNN can successfully reconstruct temperature fields over various cooling regimes. Furthermore, we also explore the algorithm’s ability to detect abnormalities. Interestingly, the CNN proves it has the capacity to detect blockage in one of the noninstrumented cooling channels.

Machine learning↗

Performance of Microreactor Test Article with Embedded Sensors During Testing in The Single Primary Heat Extraction and Removal Emulator

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes that use passive heat flow, increasing the surface area for heat transfer without requiring active coolant flow through the reactor core. Additional experimental testing is required to understand the heat rejection limitations of heat pipes and thermal stresses in the monolithic core block due to significant temperature gradients. This report describes the initial characterization and testing of a stainless-steel test article that was fabricated with embedded sensors to measure heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing to simulate nuclear heating. The electrically heated testing was performed in the Single Primary Heat Extraction and Removal Emulator facility located at Idaho National Laboratory. The ultimate goals of this work are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify the heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. Initial tests focused on the feasibility of using advanced fiber-optic sensors and other sensor technologies to improve the understanding of temperature and strain distributions within the electrically heated experiments. However, these sensing capabilities could benefit the broader microreactor community if the sensors could be used to monitor component and system health during nuclear operations to inform a limited number of microreactor operators, ultimately reducing operation and maintenance costs and moving toward semiautonomous operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of Temperature Heterogeneity in Utility-Scale Power Plant Boilers by Spatially Distributed Ultrasonic Measurements

In extreme environments, even hardened insertion sensors fail quickly. For such environments, we have developed an ultrasonic (US) method for measuring the spatial distribution of temperatures in solid materials and, specifically, across containments of extreme processes. By deploying US sensors in multiple locations, spatial heterogeneity in temperatures inside harsh environments may be characterized. In this note, we update our progress on testing the developed approach in an industrial setting and its performance in describing the temperature distribution inside a 500 MW (electrical) coalfired utility boiler of an electrical power generation plant. We use waveguides (WG) structured to contain echogenic features that produce a train of echoes in response to an excitation pulse. The time of flight between echoes encodes the information on the temperature distribution in the corresponding segment of the WG, which we reconstruct using its parametrization. Five waveguides were welded to the boiler’s heat exchange surface (waterwall) and different locations at the same boiler elevation and produced reliable US waveforms 18 months after the installation. For several weeks during the latest trial, we performed US measurements in five locations spanning half of the boiler’s 14-meter width. The measurements were acquired during regular operation, including load cycling to adjust for demand and intermittent contributions of renewable power sources, and during boiler shutdown for emergency maintenance and the subsequent restart. The interpretation of US waveforms by signal processing resulted in an accurate estimation of temperature distribution along the waveguides. We captured daily cyclical variations in demand-following load. Measurements performed in multiple locations revealed unexpected temperature variations across the boiler. We conclude that an array of developed sensors can provide responsive and spatial temperature measurements while maintaining functionality despite prolonged exposure to an extreme environment.

Walton, Kenneth↗

The Physical Parameters of Clumps Associated with Class I Methanol Masers

We present a study of the association between class I methanol masers and cold dust clumps from the APEX Telescope Large Area Survey of the Galaxy (ATLASGAL) survey. It was found that almost 100% of class I methanol masers are associated with objects listed in the ATLASGAL compact source catalog. We find a statistically significant difference in the flux density, luminosity, number and column density, and temperature distributions of ATLASGAL sources associated with 95/44 GHz methanol masers compared with those ATLASGAL sources devoid of 95 GHz methanol masers. The masers tend to arise in clumps with higher densities, luminosities, and temperatures compared with both the full sample of ATLASGAL clumps, as well as the sample of ATLASGAL sources that were cross-matched with positions previously searched for methanol masers but with no detections. Comparison between the peak position of ATLASGAL clumps and the interferometric positions of the associated class I and II methanol masers reveals that class I masers are generally located at larger physical distances from the peak submillimeter emission than class II masers. We conclude that the tight association between ATLASGAL sources and class I methanol masers may be used as a link toward understanding the conditions of the pumping of these masers and evolutionary stages at which they appear.

79 ASTRONOMY AND ASTROPHYSICS↗

Utah FORGE: Well 16B(78)-32 DTS, RFS DSS Strain, and Absolute Strain Circulation Test Fiber Optic Data - August 2024

This dataset contains processed fiber optic measurements collected during the extended cross-well circulation test at the Utah FORGE site in August 2024. The data was acquired from the 16B(78)-32 well using distributed fiber optic sensing (DFOS) technology, including distributed temperature sensing (DTS) on multimode fiber and distributed strain sensing (DSS) measurements on single-mode fiber. The dataset includes Brillouin absolute strain, Rayleigh frequency shift (RFS) DSS strain change, RFS DSS strain change rate, and temperature (DTS) data, all stored in HDF5 format. Time coordinates are provided in UTC, and depth measurements are given in measured depth relative to the rotary kelly bushing (MD RKB) in feet. The spatial sampling on the RFS DSS strain data and the Brillouin Absolute Total Strain data is 20 cm and the spatial sampling on the DTS data is 1m. The dataset is accompanied by a report from Neubrex, which provides further documentation.

15 GEOTHERMAL ENERGY↗

Nucleosynthetic Analysis of Three-dimensional Core-collapse Supernova Simulations

Abstract We study in detail the ejecta conditions and theoretical nucleosynthetic results for 18 three-dimensional core-collapse supernova (CCSN) simulations done by F ornax . Most of the simulations are carried out to at least 3 s after bounce, which allows us to follow their longer-term behaviors. We find that multidimensional effects introduce many complexities into the ejecta conditions. We see a stochastic electron fraction evolution, complex peak temperature distributions and histories, and long-tail distributions of the time spent within nucleosynthetic temperature ranges. These all lead to substantial variation in CCSN nucleosynthetic yields and differences from 1D results. We discuss the production of lighter α -nuclei, radioactive isotopes, heavier elements, and a few isotopes of special interest. Comparing pre-CCSN and CCSN contributions, we find that a significant fraction of elements between roughly Si and Ge are generally produced in CCSNe. We find that 44 Ti exhibits an extended production timescale as compared to 56 Ni, which may explain its different distribution and higher than previously predicted abundances in supernova remnants such as Cas A and SN1987A. We also discuss the morphology of the ejected elements. This study highlights the high-level diversity of ejecta conditions and nucleosynthetic results in 3D CCSN simulations and emphasizes the need for additional long-term (∼10 s) 3D simulations to properly address such complexities.

Astronomy & Astrophysics↗