Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Time Resolved Spectroscopy of High Field Polars (FUSE 00)

The following work has been accomplished: 1) The emission lines of O VI1 and He II were used to produce Doppler tomograms of the plasma emission. 2) An improved interstellar absorption model is being developed for the CIAO spectral fitting program, Sherpa. Use of the earlier version of this model showed it to be inadequate for its purpose. Once this model is working, we intend to complete our analysis of V884 Her and those of other FUSE programs. In addition to the above work, this grant has helped support the following related work: 1) The publication of the paper "Periodicities in the X-ray intensity variations of TV Columbae: an Intermediate Polar" by Rana, V. R., Singh, K. P., Schlegel, E. M., & Barrett, P. 2004, AJ, 126,489, and 2) FUSE data of a possible nova-like variable Ret 1 has been analyzed and shown to contain a hot (37000 deg) white dwarf (WD 0334-6400). The FUV spectrum shows strong absorption lines of C III.

Barrett, Paul↗

Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum

This software processes the flyby spectra of the Chirp Transform Spectrometer (CTS) of the Microwave Instrument for Rosetta Orbiter (MIRO). The tool corrects the effect of Doppler shift and local-oscillator (LO) frequency shift during the flyby mode of MIRO operations. The frequency correction for CTS flyby spectra is performed and is integrated with multiple spectra into a high signal-to-noise averaged spectrum at the rest-frame RF frequency. This innovation also generates the 8 molecular line spectra by dividing continuous 4,096-channel CTS spectra. The 8 line spectra can then be readily used for scientific investigations. A spectral line that is at its rest frequency in the frame of the Earth or an asteroid will be observed with a time-varying Doppler shift as seen by MIRO. The frequency shift is toward the higher RF frequencies on approach, and toward lower RF frequencies on departure. The magnitude of the shift depends on the flyby velocity. The result of time-varying Doppler shift is that of an observed spectral line will be seen to move from channel to channel in the CTS spectrometer. The direction (higher or lower frequency) in the spectrometer depends on the spectral line frequency under consideration. In order to analyze the flyby spectra, two steps are required. First, individual spectra must be corrected for the Doppler shift so that individual spectra can be superimposed at the same rest frequency for integration purposes. Second, a correction needs to be applied to the CTS spectra to account for the LO frequency shifts that are applied to asteroid mode.

Lee, Seungwon↗

Method for boosting dispersive spectrograph stability 1000× using interferometry with crossfaded pairs of delays

We demonstrate a key step along a technical route to achieving cm/s scale accuracy for astronomical spectrographs over long (multi-year) time scales, which is critical for the Doppler characterization of Earth sized exoplanets, and measurement of small cosmic redshift drift over many years. This same technique also enables searching exoplanet atmospheres for biosignificant molecules in direct planet imaging using, otherwise, insufficiently low resolution and drift prone dispersive (grating or prism) spectrographs. Using a method called crossfading for externally dispersed interferometers (EDIs) to get highly robust spectra, we recently demonstrated a factor of 1000 x reduction in the net shift of an EDI measured ThAr line to a deliberate simulated wavelength translation of the detector. This 1000 x gain in disperser stability can be combined with conventional stability gains afforded by fiber scramblers, vacuum tanks, and thermal control, to provide an additional 1 to 3 orders of magnitude reduction in the net point spread function shift drift. Crossfading combines high- and low-delay fringing signals that react oppositely in phase to cancel their net reaction to a detector wavelength drift. This can be implemented by an interferometer addition to a facility spectrograph.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of spectra using correlation functions

A novel method is presented for the quantitative analysis of spectra based on the properties of the cross correlation between a real spectrum and either a numerical synthesis or laboratory simulation. A new goodness-of-fit criterion called the heteromorphic coefficient H is proposed that has the property of being zero when a fit is achieved and varying smoothly through zero as the iteration proceeds, providing a powerful tool for automatic or near-automatic analysis. It is also shown that H can be rendered substantially noise-immune, permitting the analysis of very weak spectra well below the apparent noise level and, as a byproduct, providing Doppler shift and radial velocity information with excellent precision. The technique is in regular use in the Atmospheric Trace Molecule Spectroscopy (ATMOS) project and operates in an interactive, realtime computing environment with turn-around times of a few seconds or less.

Beer, Reinhard↗

Analysis of He I 1083 nm Imaging Spectroscopy Using a Spectral Standard

We develop a technique. for the analysis of He I 1083 nanometer spectra which addresses several difficulties through determination of a continuum background by comparison with a well calibrated standard and through removal of nearby solar and telluric blends by differential comparison to an average spectrum. The method is compared with earlier analysis of imaging spectroscopy obtained at the National Solar Observatory/Kitt Peak Vacuum Telescope (NSO/KPVT) with the NASA/NSO Spectromagnetograph (SPM). We examine distributions of Doppler velocity and line width as a function of central intensity for an active region, filament, quiet Sun, and coronal hole. For our example, we find that line widths and central intensity are oppositely correlated in a coronal hole and quiet Sun. Line widths are comparable to the quiet sun in the active region, are systematically lower in the filament, and extend to higher values in the coronal hole. Outward velocities of approximately equal to 2 to 4 kilometers per second are typically observed in the coronal hole. The sensitivity of these results to analysis technique is discussed.

Malanushenko, Elena V.↗

Non-intrusive flow measurements on a reentry vehicle

This study evaluates the utility of various non-intrusive techniques for the measurement of the flow field on the windward side of the Space Shuttle or a similar re-entry vehicle. Included are linear (Rayleigh, Raman, Mie, Laser Doppler Velocimetry, Resonant Doppler Velocimetry) and nonlinear (Coherent Anti-Stokes Raman, Laser Induced Fluorescence) light scattering, electron beam fluorescence, thermal emission and mass spectroscopy. Flow field properties are taken from a nonequilibrium flow model by Shinn, Moss and Simmonds at NASA Langley. Conclusions are, when possible, based on quantitative scaling of known laboratory results to the conditions projected. Detailed discussion with researchers in the field contributed further to these conclusions and provided valuable insights regarding the experimental feasibility of each of the techniques.

Miles, R. B.↗

Tunable diode laser Stark modulation spectroscopy for rotational assignment of the HNO3 7.5-micron band

The technique of Stark modulation spectroscopy for unraveling and assigning rotationally resolved dense molecular spectra has been employed using a tunable diode laser (TDL) source. Doppler-limited absorption and Stark modulation spectra of the HNO3 7.5-micron band near the 1326/cm band origin are presented with preliminary values of the excited-state rovibrational constants derived from both TDL and Bomem Fourier transform IR spectra.

Webster, C. R.↗

Laboratory molecular spectroscopy

The precision required in making spectroscopic measurements is discussed. Remarks are directed specifically to vibration-rotation spectra rather than continuum absorptions. The ultimate precision that is required for line positions is related to the width of the lines which may be no narrower than the Doppler width. The spectroscopic methods considered are those which are of the most general value to the astronomers; those which acquire and can handle large volumes of spectra in digital form, or in a form which is compatible with computer analysis, and in a form which is at least internally consistent. The use of dye laser, grating instruments, and the most versatile instrument for laboratory spectroscopy, the Fourier transform spectrometer is discussed.

Margolis, J.↗

Evaluation of non-intrusive flow measurement techniques for a re-entry flight experiment

This study evaluates various non-intrusive techniques for the measurement of the flow field on the windward side of the Space Shuttle orbiter or a similar reentry vehicle. Included are linear (Rayleigh, Raman, Mie, Laser Doppler Velocimetry, Resonant Doppler Velocimetry) and nonlinear (Coherent Anti-Stokes Raman, Laser-Induced Fluorescence) light scattering, electron-beam fluorescence, thermal emission, and mass spectroscopy. Flow-field properties were taken from a nonequilibrium flow model by Shinn, Moss, and Simmonds at the NASA Langley Research Center. Conclusions are, when possible, based on quantitative scaling of known laboratory results to the conditions projected. Detailed discussion with researchers in the field contributed further to these conclusions and provided valuable insights regarding the experimental feasibility of each of the techniques.

Miles, R. B.↗

2D coherence imaging measurements of C 2+ ion temperatures in the divertor of Wendelstein 7-X

For the first time, 2D ion temperature values are derived from coherence imaging spectroscopy (CIS) fringe contrast measurements by taking Zeeman line broadening effects into account during the analysis procedure of a spatial-heterodyne CIS instrument. This allowed 2D images of C 2+ ion temperatures (T i ) across the 3D-shaped island divertor of the Wendelstein 7-X stellarator. Ion temperatures ranging from 10 to 20 eV are observed for the C 2+ impurity species in the region above the divertor targets. During the transition from the attached to the detached plasma state, the C 2+ radiation zone moves from close to the divertor target towards the last closed flux surface. Within this radiation zone, C 2+ temperature does not decrease significantly. Experimentally, the coherence imaging measurements were cross-calibrated at one poloidal cross-section using a high resolution Echelle spectrometer, that shared its sightlines with the coherence imaging diagnostic. The spectra demonstrated that, apart from Doppler broadening, the Zeeman effect significantly contributes to the spectral line broadening and cannot be neglected when analyzing the CIS contrast data for T i extraction in the edge and scrape-off-layer of Wendelstein 7-X (W7-X), due to the relatively low temperatures (T i < 100 eV) and high magnetic fields (B ≈ 2.5 T).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute wind measurements in the lower thermosphere of Venus using infrared heterodyne spectroscopy

The first absolute wind velocities above the Venusian cloud-tops were obtained using NASA/Goddard infrared heterodyne spectrometers at the NASA Infrared Telescope Facility (IRTF) and the McMath Solar Telescope. Beam-integrated Doppler displacements in the non-thermal emission core of (12)C(16)O2 10.33 micron R(8) sampled the line of sight projection of the lower thermospheric wind field (100 to 120 km). A field-usable Lamb-dip laser stabilization system, developed for spectrometer absolute frequency calibration to less than + or - 0.1 MHz, allowed S/N-limited line of sight velocity resolution at the 1 m/s level. The spectrometer's diffraction-limited beam (1.7 arc-second HPBW at McMath, 0.9 arc-second HPBW at IRTF), and 1 to 2 arc-second seeing, provided the spatial resolution necessary for circulation model discrimination. Qualitative analysis of beam-integrated winds provided definitive evidence of a dominant subsolar-antisolar circulation in the lower thermosphere. Beam-integrated winds were modelled with a 100x100 grid over the beam, incorporating beam spatial rolloff and across-the-beam gradients in non-thermal emission intensity, line of sight projection geometry, and horizontal wind velocity. Horizontal wind velocity was derived from a 2-parameter model wind field comprised of subsolar-antisolar and zonal components. Best-fit models indicated a dominant subsolar-antisolar flow with 120 m/s cross-terminator winds and a retrograde zonal component with a 25 m/s equatorial velocity. A review of all dynamical indicators above the cloud-tops allowed development of an integrated and self-consistent picture of circulation in the 70 to 200 km range.

Goldstein, Jeffrey J.↗

Current channel evolution in ideal Z pinch for general velocity profiles

Recent diagnostic advances in gas-puff Z pinches at the Weizmann Institute for the first time allow the reconstruction of the current flow as a function of time and radius. These experiments show an unexpected radially-outward motion of the current channel, as the plasma moves radially-inward. In this paper, a mechanism that could explain this current evolution is described. Here, we examine the impact of advection on the distribution of current in a cylindrically symmetric plasma. In the case of metric compression, |v r | ∝ r, the current enclosed between each plasma fluid element and the axis is conserved, and so the current profile maintains its shape. We show that for more general velocity profiles, this simple behavior quickly breaks down, allowing for non-conservation of current in a compressing conductor, rapid redistribution of the current density, and even for the formation of reverse currents. In particular, a specific inward radial velocity profile is shown to result in radially-outward motion of the current channel, recovering the surprising current evolution discovered at the Weizmann Institute.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution continuous-wave coherent anti-Stokes Raman spectroscopy in a supersonic jet

High-resolution CW coherent anti-Stokes Raman spectra of the nu1 Q branch of methane in an underexpanded supersonic jet were obtained at temperatures as low as 31.5 K and pressures as low as 2 torr. The experimental spectra were well fitted by the calculated theoretical spectra, including transit-time broadening. A temperature of 31.5 K produced the best fit to the data, and the transit-time broadening was comparable to the residual Doppler broadening of about 100 MHz. The supersonic jet provides a convenient method of obtaining molecular cooling at relatively high density, and the ease of construction and the wide range of temperatures and densities available make it a useful tool for high resolution molecular spectroscopy.

Gustafson, E. K.↗

A spectroscopic and photometric study of FK Comae in 1989

Results of an observational campaign, coordinated between visual photometry, optical spectroscopy, and UV spectroscopy, to elucidate the characteristics of FK Comae are presented. The photometry showed complicated but systematic behavior. Photospheric absorption lines were distorted by a Doppler-shifted bump caused by dark starspots resulting in small apparent radial velocity variations. No radial velocity variations characteristic of orbital motion were seen to a level of 3 km/s. Broad emission in H-alpha was modulated at the photospheric rotational amplitude, implying an origin no farther from the rotational axis than 1 stellar radius. The strengths of Ca II lines are modulated in phase with H-alpha but do not have velocity-modulated wings like H-alpha.

Huenemoerder, David P.↗

High Resolution Infrared Spectroscopy of Highly Reactive Chemical Intermediates: Berkeley Inspiration and a C.B. Moore Retrospective

One of the long-standing paradoxes in chemistry is that the molecular species of greatest interest are often highly reactive chemical intermediates and thus present only at vanishingly small concentrations under typical steady state conditions. Here, this has proven both a key frustration and powerful motivation for physical chemists in probing such species, particularly for high resolution laser spectroscopic methods in the infrared. Over the past 4-5 decades, this fundamental sensitivity challenge has stimulated the development of many novel techniques for efficient generation, cooling, and infrared probing of such transient chemical intermediates, achieving increasingly sophisticated levels of spectroscopic detail, chemical insight, and a testbed for comparison with first principles ab initio quantum calculations. Two of the pioneering contributors to this scientific arena have been George Pimentel and C. Bradley Moore, both responsible for nourishing DJN’s own enduring fascination with spectroscopic IR study of elusive chemical intermediates. This chapter is not intended to provide a comprehensive review of this large and enormously successful field, but it rather more simply attempts to capture a few selective “Moore-centric” snapshots of the Nesbitt group scientific evolution, specifically in i) advances by Pimentel for the original development of rapid scan flash kinetic spectroscopy based on spectrometers with rapidly rotating IR gratings, ii) the modernization/extension of these methods in the Moore group toward the first high resolution IR laser spectroscopy of singlet/triplet methylene 1,3 CH 2 diradical, and finally to iii) the development of slit supersonic discharge expansion methods at JILA for sub-Doppler infrared laser study of multiple radicals, jet cooled molecular ions, and highly reactive chemical intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared spectra of van de Waals complexes of importance in planetary atmospheres

It has been suggested that (CO2)2 and Ar-CO2 are important constituents of the planetary atmospheres of Venus and Mars. Recent results on the laboratory spectroscopy of CO2 containing van der Waals complexes which may be of use in the modeling of the spectra of planetary atmospheres are presented. Sub-Doppler infrared spectra were obtained for (CO2)2, (CO2)3, and rare-gas-CO2 complexes in the vicinity of the CO2 Fermi diad at 2.7 micrometers using a color-center-laser optothermal spectrometer. From the spectroscopic constants the geometries of the complexes have been determined and van der Waals vibrational frequencies have been estimated. The equilibrium configurations are C2h, C3h, and C2v, for (CO2)2, (CO2)3, and the rare-gas-CO2 complexes, respectively. Most of the homogeneous linewidths for the revibrational transitions range from 0.5 to 22 MHz, indicating that predissociation is as much as four orders of magnitude faster than radiative processes for vibrational relaxation in these complexes.

Fraser, G. T.↗

Measuring higher-order moments of neutron-time-of-flight data for cryogenic inertial confinement fusion implosions on OMEGA

Ion temperatures serve as an important diagnostic for inertial confinement fusion (ICF) implosions. In direct-drive ICF experiments on OMEGA, neutron-time-of-flight (nTOF) data are used to infer the ion temperature of the fusing plasma produced in the implosion experiment. The analysis of the nTOF data requires an assumption about the shape of the underlying source signal. Since the source nTOF signal is a near-replica of the neutron energy spectrum, an ideal Gaussian shape, corresponding to the neutron energy spectrum of a uniform temperature plasma, is routinely employed. However, spatial and temporal variations of the ion temperature in the plasma give rise to higher-order moments, which were first described by Munro [Nucl. Fusion 56, 036001 (2016)]. In this work, we show a simpler alternative analysis to derive moments of the neutron energy spectrum for a plasma with variations in ion temperature. We also present a revised analysis of measured nTOF signals that uses a model with an additional degree of freedom to take into account the effect of ion temperature variations on the shape of the spectrum. Compared to presently used nTOF analysis, the revised analysis yields on average ≈2× more accurate fits to the data and up to 15% higher ion temperatures for cryogenic experiments. As a result, we quantify the ion temperature inflation caused by radially symmetric fluid flows, which are present even in a symmetric implosion, and which serve as a lower bound on the ion temperature inflation in real implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monitoring for neuroprotection. New technologies for the new millennium

Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.

Review↗