Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

RADIATION DOSE SIMULATIONS FOR JEFFERSON LAB’S PERMANENT MAGNET RESILIENCY LDRD STUDY

In late 2023, Thomas Jefferson National Accelerator Facil- ity (Jefferson Lab) funded a Laboratory Directed Research and Development (LDRD) grant dedicated to investigating the impact of radiation on permanent magnet materials. This research initiative is specifically geared towards assessing materials slated for use in the CEBAF energy upgrade. The experimental approach involves strategically placing perma- nent magnet samples throughout the accelerator, exposing them to varying radiation doses. The simulation code BD- SIM is used to first validate the data and then to simulate the effects on future higher energy passes to study the degra- dation effects on the permanent magnets. In this paper we present the progress of that work.

Deitrick, K.↗

Shielding Calculations for the Hard X-Rays Generated by LCLS Mec Laser System

Linac Coherent Light Source (LCLS) Matter in Extreme Conditions (MEC) Instrument is an X-ray instrument that will be able to create and diagnose High Energy Density (HED) matter. The MEC laser system can generate hard X-ray due to the interaction of the laser and the plasma. This paper summarizes results of the shielding calculations performed to evaluate the radiation hazards induced by this hard X-ray source with Monte Carlo code FLUKA. The dose rates and photon spectra due to this X-ray source are calculated at different locations with different shielding. The influence of the electron temperature on the source terms and the shielding effectiveness was also investigated.

43 PARTICLE ACCELERATORS↗

Predictive Fallout Composition Modeling: Improvements and Applications of the Defense Land Fallout Interpretive Code

This paper outlines several improvements to the Particle Activity Module of the Defense Land Fallout Interpretive Code (DELFIC). The modeling of each phase of the fallout process is discussed within DELFIC to demonstrate the capabilities and limitations with the code for modeling and simulation. Expansion of the DELFIC isotopic library to include actinides and light elements is shown. Several key features of the new library are demonstrated, including compliance with ENDF/B-VII standards, augmentation of hardwired activated soil and actinide decay calculations with exact Bateman calculations, and full physical and chemical fractionation of all material inventories. Improvements to the radionuclide source term are demonstrated, including the ability to specify heterogeneous fission types and the ability to import source terms from irradiation calculations using the Oak Ridge Isotope Generation (ORIGEN) code. Additionally, the dose, kerma, and effective dose conversion factors are revised. Finally, the application of DELFIC for consequence management planning and forensic analysis is presented. For consequence management, DELFIC is shown to provide disaster recovery teams with simulations of real-time events, including the location, composition, time of arrival, activity rates, and dose rates of fallout, accounting for site-specific atmospheric effects. The results from DELFIC are also demonstrated for use by nuclear forensics teams to plan collection routes (including the determination of optimal collection locations), estimate dose rates to collectors, and anticipate the composition of material at collection sites. These capabilities give mission planners the ability to maximize their effectiveness in the field while minimizing risk to their collectors.

54 ENVIRONMENTAL SCIENCES↗

Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations

Purpose: A dose calculation tool, which combines the accuracy of the dose planning method (DPM) Monte Carlo code and the versatility of a practical analytical multisource model, which was previously reported has been improved and validated for the Varian 6 and 10 MV linear accelerators (linacs). The calculation tool can be used to calculate doses in advanced clinical application studies. One shortcoming of current clinical trials that report dose from patient plans is the lack of a standardized dose calculation methodology. Because commercial treatment planning systems (TPSs) have their own dose calculation algorithms and the clinical trial participant who uses these systems is responsible for commissioning the beam model, variation exists in the reported calculated dose distributions. Today’s modern linac is manufactured to tight specifications so that variability within a linac model is quite low. The expectation is that a single dose calculation tool for a specific linac model can be used to accurately recalculate dose from patient plans that have been submitted to the clinical trial community from any institution. The calculation tool would provide for a more meaningful outcome analysis. Methods: The analytical source model was described by a primary point source, a secondary extra-focal source, and a contaminant electron source. Off-axis energy softening and fluence effects were also included. The additions of hyperbolic functions have been incorporated into the model to correct for the changes in output and in electron contamination with field size. A multileaf collimator (MLC) model is included to facilitate phantom and patient dose calculations. An offset to the MLC leaf positions was used to correct for the rudimentary assumed primary point source. Results: Dose calculations of the depth dose and profiles for field sizes 4 × 4 to 40 × 40 cm agree with measurement within 2% of the maximum dose or 2 mm distance to agreement (DTA) for 95% of the data points tested. The model was capable of predicting the depth of the maximum dose within 1 mm. Anthropomorphic phantom benchmark testing of modulated and patterned MLCs treatment plans showed agreement to measurement within 3% in target regions using thermoluminescent dosimeters (TLD). Using radiochromic film normalized to TLD, a gamma criteria of 3% of maximum dose and 2 mm DTA was applied with a pass rate of least 85% in the high dose, high gradient, and low dose regions. Finally, recalculations of patient plans using DPM showed good agreement relative to a commercial TPS when comparing dose volume histograms and 2D dose distributions. Conclusions: A unique analytical source model coupled to the dose planning method Monte Carlo dose calculation code has been modified and validated using basic beam data and anthropomorphic phantom measurement. While this tool can be applied in general use for a particular linac model, specifically it was developed to provide a singular methodology to independently assess treatment plan dose distributions from those clinical institutions participating in National Cancer Institute trials.

60 APPLIED LIFE SCIENCES↗

SU-E-T-578: MCEBRT, A Monte Carlo Code for External Beam Treatment Plan Verifications

Purpose: Present a new Monte Carlo code (MCEBRT) for patient-specific dose calculations in external beam radiotherapy. The code MLC model is benchmarked and real patient plans are re-calculated using MCEBRT and compared with commercial TPS. Methods: MCEBRT is based on the GEPTS system (Med. Phys. 29 (2002) 835–846). Phase space data generated for Varian linac photon beams (6 – 15 MV) are used as source term. MCEBRT uses a realistic MLC model (tongue and groove, rounded ends). Patient CT and DICOM RT files are used to generate a 3D patient phantom and simulate the treatment configuration (gantry, collimator and couch angles; jaw positions; MLC sequences; MUs). MCEBRT dose distributions and DVHs are compared with those from TPS in absolute way (Gy). Results: Calculations based on the developed MLC model closely matches transmission measurements (pin-point ionization chamber at selected positions and film for lateral dose profile). See Fig.1. Dose calculations for two clinical cases (whole brain irradiation with opposed beams and lung case with eight fields) are carried out and outcomes are compared with the Eclipse AAA algorithm. Good agreement is observed for the brain case (Figs 2-3) except at the surface where MCEBRT dose can be higher by 20%. This is due to better modeling of electron contamination by MCEBRT. For the lung case an overall good agreement (91% gamma index passing rate with 3%/3mm DTA criterion) is observed (Fig.4) but dose in lung can be over-estimated by up to 10% by AAA (Fig.5). CTV and PTV DVHs from TPS and MCEBRT are nevertheless close (Fig.6). Conclusion: A new Monte Carlo code is developed for plan verification. Contrary to phantombased QA measurements, MCEBRT simulate the exact patient geometry and tissue composition. MCEBRT can be used as extra verification layer for plans where surface dose and tissue heterogeneity are an issue.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-08: LET-Based Inverse Planning for IMPT

Purpose: Cell survival experiments suggest that the relative biological effectiveness (RBE) of proton beams depends on linear energy transfer (LET), leading to higher RBE near the end of range. With intensity-modulated proton therapy (IMPT), multiple treatment plans that differ in the dose contribution per field may yield a similar physical dose distribution, but the RBE-weighted dose distribution may be disparate. RBE models currently do not have the required predictive power to be included in an optimization model due to the variations in experimental data. We propose an LET-based planning method that guides IMPT optimization models towards plans with reduced RBE-weighted dose in surrounding organs at risk (OARs) compared to inverse planning based on physical dose alone. Methods: Optimization models for physical dose are extended with a term for dose times LET (doseLET). Monte Carlo code is used to generate the physical dose and doseLET distribution of each individual pencil beam. The method is demonstrated for an atypical meningioma patient where the target volume abuts the brainstem and partially overlaps with the optic nerve. Results: A reference plan optimized based on physical dose alone yields high doseLET values in parts of the brainstem and optic nerve. Minimizing doseLET in these critical structures as an additional planning goal reduces the risk of high RBE-weighted dose. The resulting treatment plan avoids the distal fall-off of the Bragg peaks for shaping the dose distribution in front of critical stuctures. The maximum dose in the OARs evaluated with RBE models from literature is reduced by 8–14\% with our method compared to conventional planning. Conclusion: LET-based inverse planning for IMPT offers the ability to reduce the RBE-weighted dose in OARs without sacrificing target dose. This project was in part supported by NCI - U19 CA 21239.

60 APPLIED LIFE SCIENCES↗

SU-D-16A-01: A Novel Method to Estimate Normal Tissue Dose for Radiotherapy Patients to Support Epidemiologic Studies of Second Cancer Risk

Purpose: Patient cohort of second cancer study often involves radiotherapy patients with no radiological images available: We developed methods to construct a realistic surrogate anatomy by using computational human phantoms. We tested this phantom images both in a commercial treatment planning system (Eclipse) and a custom Monte Carlo (MC) transport code. Methods: We used a reference adult male phantom defined by International Commission on Radiological Protection (ICRP). The hybrid phantom which was originally developed in Non-Uniform Rational B-Spline (NURBS) and polygon mesh format was converted into more common medical imaging format. Electron density was calculated from the material composition of the organs and tissues and then converted into DICOM format. The DICOM images were imported into the Eclipse system for treatment planning, and then the resulting DICOM-RT files were imported into the MC code for MC-based dose calculation. Normal tissue doses were calculation in Eclipse and MC code for an illustrative prostate treatment case and compared to each other. Results: DICOM images were generated from the adult male reference phantom. Densities and volumes of selected organs between the original phantom and ones represented within Eclipse showed good agreements, less than 0.6%. Mean dose from Eclipse and MC code match less than 7%, whereas maximum and minimum doses were different up to 45%. Conclusion: The methods established in this study will be useful for the reconstruction of organ dose to support epidemiological studies of second cancer in cancer survivors treated by radiotherapy. We also work on implementing body size-dependent computational phantoms to better represent patient's anatomy when the height and weight of patients are available.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-01: A System for Automatically Calculating Organ and Effective Dose for Fluoroscopically-Guided Procedures

Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to read data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Quality Assurance Plan for Federal Guidance Report 16

Federal Guidance Report No. 16 will provide risk coefficients for use in projecting the probability of cancer morbidity or mortality from exposure to environmental radionuclides. The derivation of nuclide-specific risk coefficients involves multiple steps, with each step relying on the accuracy of the previous step as well as the numerical data utilized within each step. Thus, to ensure the quality of the derived risk coefficients, it is necessary to evaluate and confirm the quality and proper implementation of input data at each step of the derivation. The Oak Ridge National Laboratory (ORNL) dosimetry research team currently has two largely independent software codes for deriving radiation dose estimates, dose coefficients, and cancer risk coefficients for internally deposited radionuclides: DCAL and QCAL. The agreement of derived values based on alternate codes is an important step in quality assurance (QA) of the risk coefficients produced in this project. DCAL is an integration of the dosimetric software and numerical databases developed at ORNL over the past 25 years for the EPA’s Office of Radiation and Indoor Air (ORIA). QCAL was developed in 2015 to serve as a substitute for DCAL while DCAL was undergoing revision and to provide QA for the updated version of DCAL. The complex methodology employed in the derivation of cancer risk coefficients presents a challenge for QA, and as such, this report describes the QA steps used by the ORNL dosimetry team in this process as implemented in DCAL and QCAL for Federal Guidance Report No. 16.

61 RADIATION PROTECTION AND DOSIMETRY↗

Update on the Code Intercomparison and Benchmark for Muon Fluence and Absorbed Dose Induced by an 18 GeV Electron Beam After Massive Iron Shielding

In 1974, Nelson, Kase and Svensson published an experimental investigation on muon shielding around SLAC high-energy electron accelerators [1]. They measured muon fluence and absorbed dose induced by 14 and 18 GeV electron beams hitting a copper/water beamdump and attenuated in a thick steel shielding. In their paper, they compared the results with the theoretical models available at that time. In order to compare their experimental results with present model calculations, we use the modern transport Monte Carlo codes MARS15, FLUKA2011 and GEANT4 to model the experimental setup and run simulations. The results are then compared between the codes, and with the SLAC data.

Fasso, A.↗

Radiological Performance Modeling: Platform Comparison

Zapadnoe Uranium Mill Tailings Site, Pridneprovsky Chemical Plant Ukraine: Two exposure scenarios were utilized to develop performance assessment models in GoldSim and NORMALYSA. The first scenario is an onsite worker exposed to radioactivity through external ground irradiation as well as radon and radioactive dust inhalation. The second being an offsite Resident 300 years after institutional control exposed through the ingestion of garden vegetables irrigated by contaminated ground water, ingestion of fish from Konoplyanka River, and agricultural activities in contaminated garden. NORMALYSA utilizes a modular interface to connect extensive pre-created modules to develop contaminant transport and risk assessment models for safety assessments and performance assessments at NORM and legacy sites. Developed by Facilia AB, the program was tested with the creation of the Zapadnoe model under the International Atomic Energy Agency MODARIA Il Working Group 1 (WG1). Default values are provided for input parameters where site specific data and distributions lack. Probabilistic simulations and inputs are limited to parameters with assigned Gaussian probability functions. Similar results for transient worker inhalation dose were found in comparison with the Zapadnoe GoldSim model. However, the NORMALYSA model has results larger by an order of magnitude for external radiation in the transient worker and for aquatic food ingestion, inhalation, and garden food ingestion to the resident. Performance Assessment Modeling: Radiological performance models promote good management and support in remediation and environmental decision making by optimizing radioactive waste disposal site performance. a performance assessment model of the Zapadnoe uranium mill tailings site and a model for calculating authorized limits at Los Alamos National Laboratory are created to demonstrate and highlight the respective capabilities of three modeling platforms: GoldSim, NORMALYSA, and RESRAD-Onsite. GoldSim is a general-purpose modeling platform with the ability to simulate site-specific FT radionuclide transport and risk assessment using a graphical interface to create and link elements that act as indivisible building blocks of the model. The Zapadnoe performance assessment model created in GoldSim is composed of input parameters collected from site specific parameters from WG1 as well as standard assumptions seen in the Generic PA Model from Neptune and Company. The multivariate Zapadnoe simulation contains both deterministic and probabilistic simulation capabilities with the ability to quantitatively represent the uncertainty and associated risks of the site via the Monte Carlo simulation method. Model parameters, documentation, and assumptions are built directly into the model creating a transparent, reproducible, and more purposeful site specific model. To demonstrate this, an ingestion of water pathway was included in addition to the exposure pathways included in the NORMALYSA model. GoldSim offers a wide variety of probability distributions to choose from as well as many tools to visualize the uncertainty of the models and explore which pathways and radionuclides dominate dose. In contrast to the NORMALYSA model, the GoldSim model uses dynamic simulation to calculate tritium concentrations. Authorized limits support the evaluation of radiological health effects from radionuclides present in bulk contaminated soil in order to assist in the process of clearing land for release under different uses. Calculations of authorized limits in RESRAD-Onsite and GoldSim models support the evaluation for 15 radionuclides using a residential exposure scenario, indoor and outdoor inhalation of dust and vapor phase radionuclides (tritium), incidental soil ingestion, and ingestion grown fruits and Vegetables. RESRAD-Onsite, developed by Argonne National Laboratory is a dedicated computer code for calculating radiation doses and cancer risks to an individual located on top of radioactively contaminated soils. It can also be used to provide guidelines for deriving radionuclide soil levels corresponding to a specific dose criterion. The menu driven user interface facilitates selection of radionuclides and soil concentrations, as well as defines parameter values related to materials, environmental factors, and exposure pathways. The program contains radionuclide-specific data such as dose conversion factors and risk coefficients, as well as soil-water partition coefficients and transfer factors for biotic media. The GoldSim model successfully emulates the RESRAD-Onsite code using identical radiological decay and ingrowth factors, radiation dose conversion factors, and other input parameters. DE EEDE ETS Each model supports dynamic modeling of radionuclide ingrowth and decay over time, and integrate this capability with the transport of radionuclides in the environment via processes such as advection and/or diffusion in fluids, or within porous solid media, The applicability of each program is heavily dependent on project context. In the context of developing Authorized Limits, RESRAD-Onsite may be a more desirable option as it was developed for this particular application. For simple disposal or legacy sites or sites that do not need site-specific model structure, NORMALYSA may be a desirable modeling platform, GoldSim can be used to model any problem for which RESRAD or NORMALYSA is applicable, but its strength lies in its flexibility, analytical, and probabilistic capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioimmunotherapy with radioactive nanoparticles: Biological doses and treatment efficiency for vascularized tumors with or without a central hypoxic area

Purpose: Radioactive atoms attached to monoclonal antibodies are used in radioimmunotherapy to treat cancer while limiting radiation to healthy tissues. One limitation of this method is that only one radioactive atom is linked to each antibody and the deposited dose is often insufficient to eradicate solid and radioresistant tumors. In a previous study, simulations with the Monte Carlo N-Particle eXtended code showed that physical doses up to 50 Gy can be delivered inside tumors by replacing the single radionuclide by a radioactive nanoparticle of 5 nm diameter containing hundreds of radioactive atoms. However, tumoral and normal tissues are not equally sensitive to radiation, and previous works did not take account the biological effects such as cellular repair processes or the presence of less radiosensitive cells such as hypoxic cells. Methods: The idea is to adapt the linear-quadratic expression to the tumor model and to determine biological effective doses (BEDs) delivered through and around a tumor. This BED is then incorporated into a Poisson formula to determine the shell control probability (SCP) which predicts the cell cluster-killing efficiency at different distances ''r'' from the center of the tumor. BED and SCP models are used to analyze the advantages of injecting radioactive nanoparticles instead of a single radionuclide per vector in radioimmunotherapy. Results: Calculations of BED and SCP for different distances r from the center of a solid tumor, using the non-small-cell lung cancer as an example, were investigated for {sup 90}Y{sub 2} O{sub 3} nanoparticles. With a total activity of about 3.5 and 20 MBq for tumor radii of 0.5 and 1.0 cm, respectively, results show that a very high BED is deposited in the well oxygenated part of the spherical carcinoma. Conclusions: For either small or large solid tumors, BED and SCP calculations highlight the important benefit in replacing the single {beta}-emitter {sup 90}Y attached to each antibody by a {sup 90}Y{sub 2} O{sub 3} nanoparticle.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-556: Monte Carlo Generated Dose Distributions for Orbital Irradiation Using a Single Anterior-Posterior Electron Beam and a Hanging Lens Shield

Purpose: Various cancers of the eye are successfully treated with radiotherapy utilizing one anterior-posterior (A/P) beam that encompasses the entire content of the orbit. In such cases, a hanging lens shield can be used to spare dose to the radiosensitive lens of the eye to prevent cataracts. Methods: This research focused on Monte Carlo characterization of dose distributions resulting from a single A-P field to the orbit with a hanging shield in place. Monte Carlo codes were developed which calculated dose distributions for various electron radiation energies, hanging lens shield radii, shield heights above the eye, and beam spoiler configurations. Film dosimetry was used to benchmark the coding to ensure it was calculating relative dose accurately. Results: The Monte Carlo dose calculations indicated that lateral and depth dose profiles are insensitive to changes in shield height and electron beam energy. Dose deposition was sensitive to shield radius and beam spoiler composition and height above the eye. Conclusion: The use of a single A/P electron beam to treat cancers of the eye while maintaining adequate lens sparing is feasible. Shield radius should be customized to have the same radius as the patient’s lens. A beam spoiler should be used if it is desired to substantially dose the eye tissues lying posterior to the lens in the shadow of the lens shield. The compromise between lens sparing and dose to diseased tissues surrounding the lens can be modulated by varying the beam spoiler thickness, spoiler material composition, and spoiler height above the eye. The sparing ratio is a metric that can be used to evaluate the compromise between lens sparing and dose to surrounding tissues. The higher the ratio, the more dose received by the tissues immediately posterior to the lens relative to the dose received by the lens.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-644: QuAArC: A 3D VMAT QA System Based On Radiochromic Film and Monte Carlo Simulation of Log Files

Purpose: VMAT involves two main sources of uncertainty: one related to the dose calculation accuracy, and the other linked to the continuous delivery of a discrete calculation. The purpose of this work is to present QuAArC, an alternative VMAT QA system to control and potentially reduce these uncertainties. Methods: An automated MC simulation of log files, recorded during VMAT treatment plans delivery, was implemented in order to simulate the actual treatment parameters. The linac head models and the phase-space data of each Control Point (CP) were simulated using the EGSnrc/BEAMnrc MC code, and the corresponding dose calculation was carried out by means of BEAMDOSE, a DOSXYZnrc code modification. A cylindrical phantom was specifically designed to host films rolled up at different radial distances from the isocenter, for a 3D and continuous dosimetric verification. It also allows axial and/or coronal films and point measurements with several types of ion chambers at different locations. Specific software was developed in MATLAB in order to process and evaluate the dosimetric measurements, which incorporates the analysis of dose distributions, profiles, dose difference maps, and 2D/3D gamma index. It is also possible to obtain the experimental DVH reconstructed on the patient CT, by an optimization method to find the individual contribution corresponding to each CP on the film, taking into account the total measured dose, and the corresponding CP dose calculated by MC. Results: The QuAArC system showed high reproducibility of measurements, and consistency with the results obtained with the commercial system implemented in the verification of the evaluated treatment plans. Conclusion: A VMAT QA system based on MC simulation and high resolution dosimetry with film has been developed for treatment verification. It shows to be useful for the study of the real VMAT capabilities, and also for linac commissioning and evaluation of other verification devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-F-16A-01: Implementation of MPPG TPS Verification Tests On Various Accelerators

Purpose: To demonstrate the implementation of the Medical Physics Practice Guideline (MPPG) for dose calculation and beam parameters verification of treatment planning systems (TPS). Methods: We implemented the draft TPS MPPG for three linacs: Varian Trilogy, TomoHDA and Elekta Infinity. Static and modulated test plans were created. The static fields are different than used in commissioning. Data was collected using ion chambers and diodes in a scanning water tank, Delta4 phantom and a custom phantom. MatLab and Microsoft Excel were used to create analysis tools to compare reference DICOM dose with scan data. This custom code allowed for the interpolation, registration and gamma analysis of arbitrary dose profiles. It will be provided as open source code. IMRT fields were validated with Delta4 registration and comparison tools. The time for each task was recorded. Results: The tests confirmed the strengths, and revealed some limitations, of our TPS. The agreement between calculated and measured dose was reported for all beams. For static fields, percent depth dose and profiles were analyzed with criteria in the draft MPPG. The results reveal areas of slight mismatch with the model (MLC leaf penumbra, buildup region.) For TomoTherapy, the IMRT plan 2%/2 mm gamma analysis revealed poorest agreement in the low dose regions. For one static test plan for all 10MV Trilogy photon beams, the plan generation, scan queue creation, data collection, data analysis and report took 2 hours, excluding tank setup. Conclusions: We have demonstrated the implementation feasibility of the TPS MPPG. This exercise generated an open source tool for dose comparisons between scan data and DICOM dose data. An easily reproducible and efficient infrastructure with streamlined data collection was created for repeatable robust testing of the TPS. The tests revealed minor discrepancies in our models and areas for improvement that are being investigated.

07 ISOTOPE AND RADIATION SOURCES↗

The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources

Purpose: The goal of this work is to compare D{sub m,m} (radiation transported in medium; dose scored in medium) and D{sub w,m} (radiation transported in medium; dose scored in water) obtained from Monte Carlo (MC) simulations for a subset of human tissues of interest in low energy photon brachytherapy. Using low dose rate seeds and an electronic brachytherapy source (EBS), the authors quantify the large cavity theory conversion factors required. The authors also assess whether applying large cavity theory utilizing the sources' initial photon spectra and average photon energy induces errors related to spatial spectral variations. First, ideal spherical geometries were investigated, followed by clinical brachytherapy LDR seed implants for breast and prostate cancer patients. Methods: Two types of dose calculations are performed with the GEANT4 MC code. (1) For several human tissues, dose profiles are obtained in spherical geometries centered on four types of low energy brachytherapy sources: {sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds, as well as an EBS operating at 50 kV. Ratios of D{sub w,m} over D{sub m,m} are evaluated in the 0-6 cm range. In addition to mean tissue composition, compositions corresponding to one standard deviation from the mean are also studied. (2) Four clinical breast (using {sup 103}Pd) and prostate (using {sup 125}I) brachytherapy seed implants are considered. MC dose calculations are performed based on postimplant CT scans using prostate and breast tissue compositions. PTV D{sub 90} values are compared for D{sub w,m} and D{sub m,m}. Results: (1) Differences (D{sub w,m}/D{sub m,m}-1) of -3% to 70% are observed for the investigated tissues. For a given tissue, D{sub w,m}/D{sub m,m} is similar for all sources within 4% and does not vary more than 2% with distance due to very moderate spectral shifts. Variations of tissue composition about the assumed mean composition influence the conversion factors up to 38%. (2) The ratio of D{sub 90(w,m)} over D{sub 90(m,m)} for clinical implants matches D{sub w,m}/D{sub m,m} at 1 cm from the single point sources. Conclusions: Given the small variation with distance, using conversion factors based on the emitted photon spectrum (or its mean energy) of a given source introduces minimal error. The large differences observed between scoring schemes underline the need for guidelines on choice of media for dose reporting. Providing such guidelines is beyond the scope of this work.

60 APPLIED LIFE SCIENCES↗