Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Rate Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Laboratory-driven Multiscale Investigation of X-Ray Induced Mass Loss and Photochemical Evolution in Cosmic Carbon and Silicate Dust

We present the results of an integrated laboratory and modeling investigation into the impact of stellar X-rays on cosmic dust. Carbonaceous grains were prepared in a cooled (< 200 K) supersonic expansion from aromatic molecular precursors, and were later irradiated with 970 eV X-rays. Silicate (enstatite) grains were prepared via laser ablation, thermally annealed, and later irradiated with 500 eV X-rays. Infrared spectra of the 3.4 μm band of the carbon sample prepared with benzene revealed 84% ± 5% band area loss for an X-ray dose of 5.2 x 10 23 eV.cm -2 . Infrared spectra of the 8 -12 μm Si-O band of the silicate sample revealed band area loss up to 63% ± 5% for doses of 2.3 x 10 23 eV.cm -2 . A hybrid Monte Carlo particle trajectory approach was used to model the impact of X-rays and ensuing photoelectrons, Auger and collisionally ionized electrons through the bulk. As a result of x-ray ionization and ensuing Coulomb explosions on surface molecules, the calculated mass loss is 60% for the carbonaceous sample and 46% for the silicate sample, within a factor of 2 of the IR band loss, supporting an X-ray induced mass-loss mechanism. We apply the laboratory X-ray destruction rates to estimate the lifetimes of dust grains in protoplanetary disks surrounding 1 M ⊙ and 0.1 M ⊙ G and M stars. In both cases, X-ray destruction timescales are short (a few million years) at the disk surface, but are found to be much longer than typical disk lifetimes (≳10 Myr) over the disk bulk.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision measurement of relative γ-ray intensities from the decay of 61Cu

A discrepancy, well outside reported uncertainties, has been observed between the accepted and measured values of the intensity ratio of the two strongest γ-ray following 61 Cu β + decay. This discrepancy has significant impact since the nat Ni(d,x) 61 Cu reaction has historically been one of only a few IAEA recommendations for use as a deuteron flux monitor and a considerable number of published cross sections measured in ratio to that beam monitor cross section may depend on the choice of either the first or second strongest ray in those calculations. To determine the magnitude of this error most precisely, over a hundred separate measurements of the 283 keV to 656 keV γ-ray emission ratio were collected from seven experiments and a variety of detectors and detection geometries. A weighted average of all these measurements indicates an error in the value listed in the Nuclear Data Sheets of 11% in either the primary or second-highest intensity γ-ray of 61 Cu, potentially introducing an 11% error in 61 Cu production cross section measurements, cross sections using nickel activation as a deuteron beam current monitor, or in dose rates when 61 Cu is used in nuclear medicine. General agreement with the Data Sheets with ten other intensity ratios suggests the most probable error is in the secondary (656 keV) emission, which accordingly should be updated from 10.8% to 9.69%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Heterogeneity effects on nondestructive assay measurements of enrichment in UF 6 cylinders

A set of measurements were performed using multiple mechanically cooled HPGe detectors at six positions around a cylinder uranium hexafluoride to assess if matrix inhomogeneity is detectible and effects the determined apparent uranium enrichment. These measurements were performed on nine 30B cylinders of uranium hexafluoride. Six of the cylinders appeared to be homogeneous and had similar apparent measured uranium enrichment, as calculated by the FRAM software, at all positions. However, three cylinders appeared to have local inhomogeneity based on the observed results. This was manifested as very low apparent enrichments, often <10% of the declared enrichment, on select positions. The side with a low apparent enrichment shows elevated daughter isotope activity (e.g., elevated 1001 keV and 766 keV peak count rate) and slightly reduced 235 U activity (lower 185.7 keV count rate). We hypothesize that these heterogenous cylinders may have experienced asymmetric solar heating, which caused volatile UF 6 to sublime preferentially away from the warmed side. A similar phenomenon was observed at a second facility where dose rate measurements confirm that the “low-enriched side” of cylinders show elevated gamma ray dose rates, likely from the removal of UF 6 attenuation and concentration of daughter-products. Care should be taken during uranium enrichment verification when applying methods that include gamma-rays associated with daughter nuclides to the determination of uranium enrichment on cylinders that are stored in sunlight and have asymmetric dose readings around the cylinder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimating dermal contact soil exposure for amphibians

Abstract Chemical exposure estimation through the dermal route is an underemphasized area of ecological risk assessment for terrestrial animals. Currently, there are efforts to create exposure models to estimate doses from this pathway for use in ecological risk assessment. One significant limitation has been insufficient published data to characterize exposure and to support the selection and parameterization of appropriate models, particularly for amphibians in terrestrial habitats. Recent publications measuring pesticide doses to terrestrial‐phase amphibians have begun to rectify this situation. We collated and summarized available measurements of terrestrial amphibian dermal exposure to pesticides from 11 studies in which researchers measured tissue concentrations associated with known pesticide experimental application rates. This data set included tissue concentrations in 11 amphibian species and 14 different pesticides. We then compared the results of two screening exposure models that differed based on surface area scaling approaches as a function of body weight (one based on birds as surrogates for amphibians and another amphibian‐specific) to the measured tissue residue concentrations. We define a false‐negative rate for each screening model as the proportion of amphibians for which the predicted concentration is less than the observed concentration (i.e., underestimate), contrary to the intent of screening models, which are intended to have a bias for higher exposure concentrations. The screening model that uses birds as surrogates did not have any instances where estimated expected avian doses were less than measured amphibian body burdens. When using the amphibian‐specific exposure model that corrected for differences between avian and amphibian surface area, measured concentrations were greater than model estimates for 11.3% of the 1158 comparisons. The database of measured pesticide concentrations in terrestrial amphibians is provided for use in calculating bioconcentration factors and for future amphibian dermal exposure model development. Integr Environ Assess Manag 2023;19:9–16. © 2022 SETAC. This article has been contributed to by U.S. Government employees and their work is in the public domain in the USA.

Environmental Sciences & Ecology↗

SCALE 6.3.1 Radiation Source Terms and Shielding Analysis for a Postulated Sodium-Cooled Fast Reactor Accident Scenario

In support of the US Nuclear Regulatory Commission non–light-water reactor fuel cycle demonstration project, SCALE 6.3.1 capabilities for radiation source term and shielding calculations are demonstrated for scenarios in the sodium-cooled fast reactor (SFR) fuel cycle. A postulated accident scenario, which consists of a seismic event causing the refueling machine to fall and release a spent fuel assembly inside the containment building (CB), is analyzed in this paper. Radiation source terms were generated for a U/TRU-10Zr metal fuel assembly with a 16.5% initial transuranic waste content and a discharge burnup of approximately 95 GWd/tHM; source terms were also generated for a high-assay low-enriched uranium metal fuel assembly (U-10Zr) with a 16.5% initial enrichment and a discharge burnup of 149.74 GWd/tHM. These radiation source terms were then used to determine the dose rate inside the CB and near the outer surface of the CB for a range of spent fuel assembly cooling times. The dose rate produced by the analyzed SFR assemblies is similar to that produced by a typical pressurized water reactor assembly with a discharge burnup of 50 GWd/MTU. Ultimately, the validation of the source terms predicted for SFRs with SCALE will need to be demonstrated via the use of assay measurements.

Radulescu, Georgeta↗

Microstructure-Dependent Rate Theory Model of Radiation-Induced Segregation in Binary Alloys

Conventional rate theory often uses the mean field concept to describe the effect of inhomogeneous microstructures on the evolution of radiation induced defect and solute/fission product segregation. However, the spatial and temporal evolution of defects and solutes determines the formation and spatial distribution of radiation-induced second phase such as precipitates and gas bubbles/voids, especially in materials with complicated microstructures and subject to high dose radiation. In this work, a microstructure-dependent model of radiation-induced segregation (RIS) has been developed to investigate the effect of inhomogeneous thermodynamic and kinetics properties of defects on diffusion and accumulations of solute A in AB binary alloys. Four independent concentrations: atom A, interstitial A, interstitial B, and vacancy on [A, B] sublattice are used as field variables to describe temporal and spatial distribution and evolution of defects and solute A. The independent concentrations of interstitial A and interstitial B allow to describe their different generation rates, thermodynamic and kinetic properties, and release the assumptions of interstitial generation and sink strength used in the conventional rate theory. Microstructure and concentration dependent chemical potentials of defects are used to calculate the driving forces of defect diffusions. With the model, the effects of defect chemical potentials and mobilities on the RIS in polycrystalline AB model alloys have been simulated. The results demonstrated the model capability in predicting defect evolution in materials with inhomogeneous thermodynamic and kinetic properties of defects. The model can be extended to materials with complicated microstructures such as a wide range of grain size distribution, coating structure and multiphases as well as radiation-induced precipitation subject to severe radiation damage.

36 MATERIALS SCIENCE↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at the Idaho National Laboratory (INL) Radiological Response Training Range (RRTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K2O, LaBr3, KBr, Cu, Zr, F, Ga, Ga2O3, NaNO2, Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated assuming 12 tests are conducted annually using all 11 material types for a period of 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradioactive chemical

54 ENVIRONMENTAL SCIENCES↗

Hanford Site Composite Analysis Special Analysis: Inventory and Solid Waste Release Modeling for the LLBG Sensitivity Case - UCAQ-22-01 Inventory Discrepancies for 218-E-12B, 218-W-3A, and 218-W-3AE in the Hanford Site Composite Analysis

This environmental calculation file (ECF) documents the methodologies, assumptions, and results of four sensitivity analyses that reevaluate the representativeness of solid-waste radionuclide inventory and release rate from three solid waste sites included in the recently completed Hanford Site Composite Analysis (CA) (DOE-RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020), Rev. 1) (hereinafter called the CA Update). Specifically, this ECF reevaluates the representativeness of the base case inventory and radionuclide waste release rates from three solid waste sites (i.e., 218-E-12B, 218-W-3A, and 218-W-3AE) and two radionuclides (i.e., carbon-14 [C-14] and technetium-99 [Tc-99]). These three waste sites and two radionuclides were identified as being the most significant contributors to groundwater contamination and dose in the CA Update for the Inner Area boundary at times periods after the compliance period. This ECF first evaluates the representativeness of the C-14 and Tc-99 inventory and second, radionuclide release rates for the three waste sites1. If the inventory and release rates assumed in the CA Update are determined to be not representative, as hypothesized in the CA Update, then this ECF evaluates the impact of more representative inventories and release rates on the transfer of radionuclides to the vadose zone. The four analyses described in this ECF are as follows: 1) 218-E-12B C-14 Inventory and Release Rate Sensitivity Case – Determine the representativeness of the C-14 inventory and associated waste release rate from the 218-E-12B waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted C-14 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 2) 218-W-3A C-14 Inventory and Release Rate Sensitivity Case – Determine the representativeness of the C-14 inventory and associated waste release rate from the 218-W-3A waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted C-14 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 3) 218-W-3AE Tc-99 Release Rate Sensitivity Case – Determine the representativeness of the Tc-99 inventory and associated waste release rate from the 218-W-3AE waste site assumed in the CA Update. If the inventory and associated waste release are more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted Tc-99 release rate and compare the results to the results presented in the CA Update (DOE/RL-2019-52); 4) 218-W-3AE Tc-99 Release Footprint Sensitivity Case – Determine the representativeness of the Tc-99 waste area footprint for the 218-W-3AE waste site assumed in the CA Update. If the footprint of the waste is more appropriately characterized as being different from the assumptions in the CA Update, then update the predicted Tc-99 release rate and compare the results to the result presented in the CA Update (DOE/RL-2019-52).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis Special Analysis: P2R Model Predictive Contaminant Transport Simulations - Sensitivity Case

This environmental calculation file (ECF) documents the methodologies, assumptions, and results of predictive fate and transport simulations using the Plateau-to-River (P2R) model. This ECF supports the reevaluation of the representativeness of solid-waste radionuclide inventory and release rate from three solid waste sites included in the recently completed Hanford Site Composite Analysis (CA) (DOE-RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020)). Specifically, this ECF supports the reevaluation of the representativeness of the base case inventory and radionuclide waste release rates from three solid waste sites (i.e., 218-E-12B, 218-W-3A and 218-W-3AE) and two radionuclides (carbon-14 [C-14] and technetium [Tc-99]). These three waste sites and two radionuclides were identified as being the most significant contributors to groundwater contamination and dose in the CA at time periods after the compliance period. The release rates and footprints of the releases from the vadose zone are implemented in the fate and transport modeling utilizing the HSS package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Minimum Detectable Activities for Stack Sample Analyses

The Rad-NESHAP program takes samples at major point sources to track how much of select nuclides are being emitted out of the stack. Samples are taken at the site where the radiological operations are being performed. The samples are then sent to analytical laboratories for analysis to determine what nuclides exist in the sample. However, due to the sensitivity of the instruments, false positives are often reported. To reduce the number of false positives, the results reported from the analytical labs are compared to set detection limits. Anything below the set detection limit is considered part of the background while anything above the limit is considered a positive hit. Therefore, the detection limit must be set low enough that any false negatives do not result in a significant dose missed at the end of the year but high enough that there are not enough false positives to skew the annual dose being reported. All detection limits listed in this section for the analyses below were designed to meet the stated equivalent emissions rate and subsequent off-site doses. These minimum detectable activities (MDAs) were developed in the 1990s and documented in the memo cited for each analysis below. These limits and memos are all currently referenced in the Quality Assurance Project Plan (QAPP) for the Rad-NESHAP Compliance Task, which is being updated to a Project Implementation Plan (PIP) concurrently with this document. As part of this update process, the original MDAs defined in this section needed to be verified that they were still conservative and meet the off-site dose levels stated.

2019 MDA↗

Activation Analysis in Preparation for a Tungsten Irradiation Experiment at LANSCE

To organize the safe handling of activated material, knowing the residual dose rates is crucial. Here, in this work, we present the pre-experiment activation analysis for an experiment in which tungsten blocks are irradiated by 800-MeV protons. In this analysis, we use the Monte Carlo N-Particle (MCNP) code for radiation transport, Attila4MC for unstructured mesh generation, and Activation in Accelerator Radiation Environments (AARE), including CINDER2008, for activation analysis. If the tungsten blocks must be removed within a day after the experiment, then exposure to personnel entering the room must be reduced. One exposure-reduction strategy is to add carbon steel shielding around the tungsten blocks, efficiently reducing the dose from the activated tungsten. However, the shielding becomes activated itself during irradiation: 56Mn is the dominant contributor for short decay times. The actual schedule at the time of the experiment allowed sufficient cool-off time for the tungsten in the room so that additional shielding was not necessary. A less rigorous comparison of the calculated values with the post-experiment measurements showed reasonable agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atom Probe Tomography for understanding microstructural and chemical changes in nuclear materials

Atom Probe Tomography (APT) is routinely employed to determine 3D microstructure and chemistry changes in structural materials used in reactor to understand irradiation effect. These findings help to correlate changes to mechanical and physical properties of nuclear materials which are subjected to extreme reactor conditions. With safety and economics of a reactor in mind, it is essential to be able to predict the changes in the fuel composition and microstructure as a function of burnup. Also, there is current need to develop advanced fuels with improved properties and performance which requires the experimental data on changes in microstructure, physical and chemical properties after irradiation for feedback process. A novel approach is presented to determine the local burnup in irradiated fuels using isotopic quantification obtained by Atom Probe Tomography (APT). Considering the volume of sample used (<100?µm3) for APT experiments using the lift-out process in a scanning electron microscope equipped with a Focused Ion Beam (FIB), the presented method determines the local burnup from a nuclear fuel, where a minimal amount of waste is produced. In this work, three samples were analyzed with different burnup conditions to quantify the isotopes of 235U, 236U, and 238U for burnup calculation in the irradiated metallic U–7Mo dispersion fuel. The calculated values were found in excellent agreement with MCNP calculations. With regard to structural materials, one of the primary factors limiting the utilization of fuel rods of Zr alloys is hydrogen pick up during oxidation. Past experimental studies have shown that the hydrogen pickup in Zirconium alloys is influenced by the alloy composition as well by irradiation temperature and neutron dose. Oftentimes, it is not feasible to carry out comprehensive studies on understanding the microstructural evolution in neutron irradiated materials since in reactor irradiation programs are extremely costly, lengthy and logistically complicated. The use of ion irradiation as a substitute has grown in recent years for several reasons including less radioactivity, faster irradiations and lower costs. In the framework of the MUZIC 3 project, samples of Zircaloy-4 have been proton and Zr2+ irradiated at the Michigan Ion Beam Lab (MIBL) facility with aim to create a microstructure that is similar to that observed after in-reactor service. The temperature of the environment is adjusted to compensate for the higher dose rate, as has been done previously. As a first step in this project the irradiated microstructures have been characterized using Transmission Electron Microscopy and Atom Probe Tomography to elucidate the microstructural changes, including precipitate amorphization and dissolution and the formation of dislocation loops. This presentation plans to highlight initial finding of this project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ProZES: the methodology and software tool for assessment of assigned share of radiation in probability of cancer occurrence

ProZES is a software tool for estimating the probability that a given cancer was caused by preceding exposure to ionising radiation. ProZES calculates this probability, the assigned share, for solid cancers and hematopoietic malignant diseases, in cases of exposures to low-LET radiation, and for lung cancer in cases of exposure to radon. User-specified inputs include birth year, sex, type of diagnosed cancer, age at diagnosis, radiation exposure history and characteristics, and smoking behaviour for lung cancer. Cancer risk models are an essential part of ProZES. Linking disease and exposure to radiation involves several methodological aspects, and assessment of uncertainties received particular attention. ProZES systematically uses the principle of multi-model inference. Models of radiation risk were either newly developed or critically re-evaluated for ProZES, including dedicated models for frequent types of cancer and, for less common diseases, models for groups of functionally similar cancer sites. The low-LET models originate mostly from the study of atomic bomb survivors in Hiroshima and Nagasaki. Risks predicted by these models are adjusted to be applicable to the population of Germany and to different time periods. Adjustment factors for low dose rates and for a reduced risk during the minimum latency time between exposure and cancer are also applied. The development of the methodology and software was initiated and supported by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) taking up advice by the German Commission on Radiological Protection (SSK, Strahlenschutzkommission). These provide the scientific basis to support decision making on compensation claims regarding malignancies following occupational exposure to radiation in Germany.

97 MATHEMATICS AND COMPUTING↗

Summary of Graphite Data Stored within NDMAS

The Graphite Technology Development Project provides data to support the design of graphite core components within specific reactor service conditions of the next generation of high-temperature, gas-cooled nuclear reactors. Physical, mechanical, and thermal properties of nuclear grade graphite were characterized for specimens that were unirradiated, irradiated, and irradiated under various stress conditions. The material properties include diameter, length, mass, density, compressive strength, tensile strength, flexural strength, modulus, resistivity, thermal diffusivity, and thermal expansion coefficient. Baseline graphite specimens are unirradiated from different grades (2114, IG-110, NBG-17, NBG-18, and PCEA) and different types used in different characterization tests (compressive, flexural, tensile, one-inch cylinder, and quarter-inch cylinder). The Advanced Graphite Creep (AGC) irradiation specimens are from a much larger number of grades and cylinder types (creep, piggyback, and pencil). For baseline graphite, characterization data for 7,756 specimens extracted from thirteen graphite billets were captured to the NDMAS database. For AGC experiments, four irradiation campaigns have been completed: AGC-1, AGC-2, AGC-3, and AGC-4. The ongoing HDG-1 (High-Dose Graphite) experiment, which began irradiation with Cycle 168B on August 26, 2020, includes specimens previously irradiated in AGC-2 in addition to the specimens originally destined for AGC-5.. Besides the characterization data, the AGC data includes irradiation monitoring and physics data representing the irradiation conditions of AGC specimens. Currently, all data for AGC-1, AGC-2, and AGC-3 have been captured to the NDMAS database. Only AGC-4 pre-irradiation and irradiation monitoring data have been captured, and HDG-1 pre-irradiation data are in process of being captured for unirradiated specimens. To date, a total of 38,149 material property records have been captured into NDMAS database for baseline and AGC specimens. All characterization data are qualified for use according to their perspective data verification reports. For the AGC irradiation campaigns, a total of 41,502 qualified physics calculation records were added for AGC-1, AGC-2, and AGC-3. Finally, a total of 173,698,505 AGC irradiation monitoring data records (thermocouple temperature, gas flow rate, gas pressure, gas moisture, applied load, and specimen displacement) have been captured to NDMAS; the majority of those records (~94%) are qualified data records.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of energy correction coefficient for neutron albedo dosimeter. Three approaches

To accurately determine dose, albedo TLD dosimeters require application of a neutron energy correction factor (NECF). Here, in this paper, the results from three different methods were used to determine NECFs. In the first method, NECF values were calculated as a ratio of the known “conventional true” dose and the neutron dose reported by albedo dosimeter(s) irradiated on a phantom. The results from this direct method were utilized for verification of two other methods. The second method used a specially designed device called the Neutron Area Monitor (NAM) model 5. The third method of NECF determination was based on the response of a BF 3 tube under different levels of moderation. The results of this work showed that the Navy-developed Neutron Area Monitor (NAM) model 5 measures NECF values correctly when irradiated with 252 Cf (bare and D 2 O-moderated). This was an important result, because it validated the use of the NAM-5 in nuclear power and marine propulsion reactors, as their neutron energy spectrum is approximated by the field of a Cadmium-coated 30 cm diameter steel sphere of D 2 O moderated 252 Cf. In the case of a broad neutron energy spectrum the 6 Li response to the small amount of slow neutrons outweighs its response to the fast neutrons overwhelmingly responsible for the neutron dose rate. Based on the obtained results we can conclude that NAM-5 provides correct NECF determination if the fraction of slow neutrons in the neutron dose rate is more than 20%. A satisfactory correlation between the NECF determined by NAM-5 and the multi-moderated BF3 tube method was observed, but the multi-moderated BF 3 tube values were ~30% lower than those obtained by the NAM-5 at the same locations for broader neutron energy spectrum locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Coefficient Calculation for Use in Dosimetry Assessment of a Fission-Based Weapon

In the event of a fission-based weapon or improvised nuclear device (IND) detonation, dose coefficients can be harnessed to provide dose assessments for defense, emergency preparedness, and consequence management, as well as to prospectively inform the assessment of radiation biomarkers and development of medical prophylaxis countermeasures for defense and homeland security stakeholders and decision-makers. Although dose coefficients have previously been calculated for this group, they would apply specifically to the studied population, the 1945 Japanese cohort, after which their anthropomorphic computational phantoms were modeled. For this reason, applications to other populations may be limited, and instead, an assessment of a more standardized population is desired. We employed a series of computational human phantoms representing international reference individuals: UF/NCI voxel phantom series containing newborn, 1-, 5-, 10-, 15-, and 35-year-old males and females. Irradiation of the phantoms was simulated using the Monte Carlo N-Particle transport code to determine organ dose coefficients under four idealized irradiation geometries at three distances from the detonation hypocenter at Hiroshima and Nagasaki using DS02 free-in-air prompt neutron and photon fluence spectra. Through these simulations, age-specific dose coefficients were determined for individual organs. Various articulated PIMAL stylized phantoms were simulated as well to estimate the effect of body posture on dose coefficients and determine the effect of posture on dosimetric estimation and reconstruction. Results additionally demonstrate that 137 Cs and the Watt fission spectra are not ideal general surrogate sources for fission weapons, which may be considered for experimental testing of medical countermeasures. Supplementary data provided tabulates the compilation of organ dose-rate coefficients in this study.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Temperature Effects on Interdiffusion of Al and U-Mo under Irradiation

A high-energy Xe ion irradiation experiment was conducted to investigate the temperature dependence of interdiffusion in bilayer Al-UMo samples under irradiation. The amount of interdiffusion achieved at a fixed dose with the increase of temperature showed a clear transition at 175 degrees C (with an estimated error in the range of ± 10 degrees C) from temperature-independent to temperature-dependent behavior. The activation energy derived from the curve of interdiffusion quantity vs. irradiation temperature is 0.77 ± 0.16 eV. This information has been utilized to understand the temperature effect on the interdiffusion process that occurred at the interfaces of U-Mo particles and the Al matrix in U-Mo/Al dispersion fuels, whose magnitude significantly impacts the fuel's performance. Although this temperature effect was deemed important, it cannot be examined directly using in-pile irradiation data, as fuel temperatures cannot be measured in reactor irradiation and are highly correlated with fission rate and thermal conductivity evolution. To connect the knowledge accumulated from ion irradiation with in-pile irradiation data, simulation of a full-sized U-Mo/Al dispersion fuel plate irradiated in the FUTURE test in the BR2 reactor was performed with the Dispersion Analysis Research Tool (DART), a dispersion fuel performance code. DART is equipped with an interaction or interdiffusion layer (IL) growth correlation formulated to describe the temperature dependence of ion mixing results. The agreement between calculated and measured fuel meat constituent volume fractions and swelling data demonstrated that the temperature effect on in-pile Al-UMo interdiffusion is well captured with the correlation. In this case, the fitted activation energy is 0.70 eV. Considering the uncertainties associated with the ion irradiation data, the activation energy obtained from in-pile data fitting is in accord with that from ion irradiation results.

36 MATERIALS SCIENCE↗

Fading study of Harshaw LiF:Mg,Ti thermoluminescence dosimeters exposed to neutron doses

Sensitivity and signal fading were tested in Harshaw LiF:Mg,Ti thermoluminescence dosimeters (TLDs) exposed to neutron and beta/photons doses. A significant difference in the signal fading rate was observed for TLDs exposed to neutrons compared with TLDs exposed to betas. This difference may have been related to differences in glow curves for dosimeters exposed to different beams and to differences in glow curve evolution after exposure. A fading-correction algorithm was developed to correct the cumulative sensitivity + signal fading of TL doses for the fading time t using the formulae: y = 0.147∗exp(-t/4.36) + 0.308∗exp(-t/34.1) + 0.73 for neutrons, and: y = 0.132∗exp(-t/10.72) + 0.174∗exp(-t/31.5) + 0.8 for betas/photons. The formula was validated using the dose recovery test, where the average deviation of fading-corrected doses from delivery doses was within 1%. In conclusion, the proposed fading-correction approaches may significantly improve the accuracy of Harshaw TL dosimetry with LiF:Mg,Ti cards for both neutron and beta/gamma irradiation.

61 RADIATION PROTECTION AND DOSIMETRY↗