Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC INSPECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

MMOD Impact Damage to ISS

Paper will describe micrometeoroid and orbital debris (MMOD) damage that has been observed on the International Space Station (ISS). Several hundred documented MMOD damage sites on ISS have been identified through imagery from the windows of ISS modules or docked vehicles. Sites that are observable from ISS or shuttle windows exhibiting distinct features of hypervelocity impact damage are usually greater than 5mm in diameter. Many smaller features are revealed in on-orbit imagery are typically less distinct and difficult to characterize but could be MMOD damage. Additional images of on-orbit damage features have been collected by astronauts during extra vehicular activities. Ground inspection of returned ISS hardware has also contributed to the database of ISS MMOD impact damage. A handful of orbital replacement units (ORU) from the ISS active thermal control and electrical power subsystems were swapped out and returned during the Space Shuttle program. In addition, a reusable logistics module was deployed on ISS for a total 59.4 days on 11 shuttle missions between 2001 and 2011 and then brought back in the shuttle payload bay. All of this returned hardware was subjected to detailed post-flight inspections for MMOD damage, and a database with nearly 1000 impact records has been collected. A description of the largest observed damages will be provided in the paper. In addition, a discussion of significant MMOD impact sites with operational or design aspects will be presented. Some of the ISS modules/subsystems damaged by MMOD to be included in the discussion are (1) Solar Arrays, (2) US and Russian windows, (3) EVA handrails, (4) Radiators, and (5) Russian FGB module.

Hyde, James L.↗

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY↗

SolarAPP+ Pilot Analysis: Performance and Impact of Instant, Online Solar Permitting

The National Renewable Energy Laboratory (NREL) led a collaborative effort to develop the Solar Automated Permit Processing Plus (SolarAPP+), a no-cost solar permitting software solution to address residential solar photovoltaic (PV) permitting resource constraints and streamline solar adoption processes among authorities having jurisdiction (AHJs). The SolarAPP+ is an online portal that automates permit plan review, enabling an instant permit approval process for code-compliant residential PV systems. Based on national model building, electrical, and fire codes, the SolarAPP+ automatically performs a compliance check of permit inputs against code requirements and produces an inspection checklist that can be used to verify installation practices, workmanship, and adherence to the approved design. NREL conducted a two-phase pilot with five participating AHJs and 16 solar contractors, spanning from November 2020 through December 2021, evaluating the ability of SolarAPP+ to deliver instant permits and its impact on four critical areas within each AHJ: permit review timelines; solar adoption timelines; AHJ time saved; and inspection results. The pilot confirmed that SolarAPP+ reduced permit review times to less than one day, reduced solar adoption timelines by an average of 12 days, saved an estimated 2,067 staff hours, and had comparable inspection results to those found in traditional permitting. The pilot further identified key lessons for improving SolarAPP+, including ways to streamline SolarAPP+ adoption, development of training resources, and expansion of supported products.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CF6-6D engine performance deterioration

Cruise cockpit recordings and test cell performance data in conjunction with hardware inspection data from airline overhaul shops were analyzed to define the extent and magnitude of performance deterioration of the General Electric CF6-6D model engine. These studies successfully isolated short-term deterioration from the longer term, and defined areas where a significant reduction in aircraft energy requirements for the 1980's can be realized. Unrestored losses which remain after engine refurbishment represent over 70% of the loss at engine shop visit. Sixty-three percent of the unrestored losses are cost-effective to restore which could reduce fuel consumed by CF6-6D engines in 1980 by 10.9 million gallons.

Wulf, R. H.↗

Engine diagnostics program: CF6-50 engine performance deterioration

Cockpit cruise recordings and test cell data in conjunction with hardware inspection results from airline overhaul shops were analyzed to define the extent and magnitude of performance deterioration of the General Electric CF6-50 high bypass turbofan engine. The magnitude of short term deterioration was isolated from the long term, and the individual damage mechanisms that were the cause for the majority of the performance deterioration was identified. It was determined that the long term engine performance deterioration characteristics were different for the 3 aircraft types currently powered by the CF6-50 engine, but these differences were due to operational considerations (flight length and takeoff derate) and not to differences associated with the aircraft type. Unrestored losses, that is, performance deterioration which remains after engine refurbishment, represents over 70 percent of the total performance deterioration at engine shop visit. Superficial damage, such as, increased surface roughness, leading edge shape changes on airfoils, and increases in the average clearances between rotating and stationary components is the major contributor to these losses. Seventy one percent of the unrestored losses are cost effective to restore, and if implemented could reduce fuel consumed by CF6-50 engines by 26 million gallons in 1980.

Wulf, R. H.↗

Summary report for CF6 jet engine diagnostics program

Cockpit cruise recordings and test cell data in conjunction with hardware inspection results from airline overhaul shops were analyzed to define the extent and magnitude of performance deterioration of the General Electric CF6 high bypass turbofan engines. The magnitude of Short Term deterioration from the Long Term was isolated and the individual damage mechanisms that were the cause for the majority of the performance deterioration were identified. A potential for reduction in compressor clearance and a potential for improvement in turbine roundness, which corresponds to cruise SFC reductions of 0.38 and 0.36 percent, respectively, were identified.

Fasching, W. A.↗

Determining Internal Connections in Capacitors

Simple electrical test shows which terminals connected to outer capacitor foil. Test makes it unnecessary to resort to X-ray inspection to distinguish terminals. When outer foil of capacitor is attached to ungrounded signal-generator output lead, oscilloscope displays higher waveform amplitude. When outer foil is joined to grounded signalgenerator output lead, waveform amplitude is lower. Test also used to determine internal connections in multiple-element capacitors.

Ott, F. M.↗

Effects of natural environment on first generation solid rocket booster thermal protection system materials

The effort to demonstrate, by real-time exposure, the effects of the natural environment at Kennedy Space Center, Florida, upon the Thermal Protection System (TPS) of the Solid Rocket Booster (SRB) is summarized, and that the overall SRB TPS configuration is verified to meet all requirements for resistance to the conditions associated with outdoor weathering, including: solar radiation; temperature; humidity; precipitation; wind; sand/dust abrasion; static electricity; salt spray; fungus; and atmospheric oxidants. The evaluation criterion for this project was based upon flatwise tensile properties, visual inspection, color change, and thermal performance. Based upon the evaluation of the changes in these properties, it is concluded that properly applied and topcoat-protected TPS can satisfactorily withstand the conditions of the natural environment at KSC for exposures up to six months.

Webb, D. D.↗

Simple Method For Detection Of Intergranular Attack

Evidence of intergranular attack occurring on chemically milled and wire-electrical-discharge-machined metal parts detected with replicating tape which makes it unnecessary to manufacture and stock test coupons and inspect them microscopically. Tape pressed on part to be inspected. When removed, it presents visual evidence of intergranular attack.

Jackson, Amy A.↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

NASAs Evolutionary Xenon Thruster (NEXT) Long-Duration Test (LDT) is part of the comprehensive service life assessment of the NEXT thruster. The test was voluntarily terminated in April 2014 after accumulating 51,184 hours of high voltage operation, processing 918 kg of xenon, and delivering 35.5 MN-s of total impulse. This presentation covers the post-test inspection of the thruster hardware, in particular of the discharge chamber and other miscellaneous components such as propellant isolators and electrical cabling.

Ion Thrusters↗

Urban Air Mobility Community Noise Test Planning

The term “Advanced Air Mobility” has been adopted by NASA to describe safe, sustainable, affordable, and accessible aviation for transformational local and intraregional missions. By this definition, Advanced Air Mobility includes both “rural” and “urban” applications including cargo and passenger transport missions, and other aerial missions (e.g., infrastructure inspection). There will be a range of aircraft types performing such missions, including small and medium Unmanned Aircraft Systems (UAS), electric Conventional Takeoff and Landing (eCTOL) aircraft, and electric Vertical Takeoff and Landing (eVTOL) aircraft. Urban Air Mobility (UAM) is a challenging use case for transporting cargo and passengers in an urban environment and is a new opportunity for aviation that could revolutionize the transportation system. The National Aeronautics and Space Administration and the Noise Division of the Federal Aviation Administration Office of Environment and Energy have initiated discussions for planning UAM community noise test(s) at the end of this decade. This presentation discusses the test goals, candidate test objectives, and some of activities needed in preparation for the test(s). It also draws distinctions between the type of study envisioned (observational vs. staged), and between it and recent and planned studies on large fixed-wing transports and commercial supersonic transports.

urban air mobility↗

End-of-Test Performance and Wear Characterization of NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test

The NASA's Evolutionary Xenon Thruster (NEXT) program is developing the next-generation solar electric ion propulsion system with significant enhancements beyond the state-of-the-art NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) ion propulsion system to provide future NASA science missions with enhanced capabilities. A Long-Duration Test (LDT) was initiated in June 2005 to validate the thruster service life modeling and to quantify the thruster propellant throughput capability. Testing was recently completed in February 2014, with the thruster accumulating 51,184 hours of operation, processing 918 kg of xenon propellant, and delivering 35.5 MN-s of total impulse.As part of the test termination procedure, a comprehensive performance characterization was performed across the entire NEXT throttle table. This was performed prior to planned repairs of numerous diagnostics that had become inoperable over the course of the test. After completion of these diagnostic repairs in November 2013, a comprehensive end-of-test performance and wear characterization was performed on the test article prior to exposure to atmosphere. These data have confirmed steady thruster performance with minimal degradation as well as mitigation of numerous life limiting mechanisms encountered in the NSTAR design. Component erosion rates compare favorably to pretest predictions based on semi-empirical models used for the thruster service life assessment. Additional data relating to ion beam density profiles, facility backsputter rates, facility backpressure effects on thruster telemetry, and modulation of the neutralizer keeper current are presented as part of the end-of-test characterization. Presently the test article for the NEXT LDT has been exposed to atmosphere and placed within a clean room environment, with post-test disassembly and inspection underway.

wear tests↗

Thunderstorm hazards flight research: Storm hazards 1980 overview

A highly instrumented NASA F-106B aircraft, modified for the storm hazards mission and protected against direct lightning strikes, was used in conjunction with various ground based radar and lightning measurement systems to collect data during thunderstorm penetration flights. During 69 thunderstorm penetrations, there were 10 direct lightning strikes to the aircraft. No problems were encountered with any of the aircraft's systems as a result of the strikes and the research instrumentation performed as designed. Electromagnetic characteristics of nine strikes were recorded, and the results of other experiments confirm the theory that X-ray radiation and nitrous oxide gas are being produced by processes associated directly with thunderstorm electric fields and lightning discharges. A better understanding of aircraft lightning attachment mechanisms and strike zones is being accomplished by careful inspection, identification, and documentation of lightning attachment points and swept stroke paths following each strike to the aircraft.

Deal, P. L.↗

NASA/ASEE Summer Faculty Fellowship Program. 1991 Research Reports

Reports from the NASA/ASEE Summer Faculty Fellowship Program are presented. The editors are responsible for selecting appropriately qualified faculty to address some of the many problems of current interest to NASA Kennedy. Some representative titles are as follows: Development of an Accelerated Test Method for the Determination of Susceptibility to Atmospheric Corrosion; Hazardous Gas Leak Analysis in the Space Shuttle; Modeling and Control of the Automated Radiator Inspection Device; Study of the Finite Element Software Packages at KSC; Multispectral Image Processing for Plants; Algorithms for Contours Depicting Static Electric Fields during Adverse Weather Conditions; Transient Study of a Cryogenic Hydrogen Filling System; and Precision Cleaning Verification of Nonvolatile Residues by using Water, Ultrasonics, and Turbidity Analyses.

Hosler, E. Ramon↗

Reliability of Ceramic Column Grid Array Interconnect Packages Under Extreme Temperatures

A paper describes advanced ceramic column grid array (CCGA) packaging interconnects technology test objects that were subjected to extreme temperature thermal cycles. CCGA interconnect electronic package printed wiring boards (PWBs) of polyimide were assembled, inspected nondestructively, and, subsequently, subjected to ex - treme-temperature thermal cycling to assess reliability for future deep-space, short- and long-term, extreme-temperature missions. The test hardware consisted of two CCGA717 packages with each package divided into four daisy-chained sections, for a total of eight daisy chains to be monitored. The package is 33 33 mm with a 27 27 array of 80%/20% Pb/Sn columns on a 1.27-mm pitch. The change in resistance of the daisy-chained CCGA interconnects was measured as a function of the increasing number of thermal cycles. Several catastrophic failures were observed after 137 extreme-temperature thermal cycles, as per electrical resistance measurements, and then the tests were continued through 1,058 thermal cycles to corroborate and understand the test results. X-ray and optical inspection have been made after thermal cycling. Optical inspections were also conducted on the CCGA vs. thermal cycles. The optical inspections were conclusive; the x-ray images were not. Process qualification and assembly is required to optimize the CCGA assembly, which is very clear from the x-rays. Six daisy chains were open out of seven daisy chains, as per experimental test data reported. The daisy chains are open during the cold cycle, and then recover during the hot cycle, though some of them also opened during the hot thermal cycle..

Ramesham, Rajeshuni↗

Optical Microscopy Techniques to Inspect for Metallic Whiskers

Metal surface finishes of tin, zinc and cadmium are often applied to electronic components, mechanical hardware and other structures. These finishes sometimes unpredictably may form metal whiskers over periods that can take from hours to months or even many years. The metal whiskers are crystalline structures commonly having uniform cross sectional area along their entire length. Typical whisker dimensions are nominally on the order of only a few microns (um) across while their lengths can extend from a few microns to several millimeters. Metal whiskers pose a reliability hazard to electronic systems primarily as an electrical shorting hazard. The extremely narrow dimensions of metal whiskers can make observation with optical techniques very challenging. The videos herein were compiled to demonstrate the complexities associated with optical microscope inspection of electronic and mechanical components and assemblies for the presence or absence of metal whiskers. The importance of magnification, light source and angle of illumination play critical roles in being able to detect metal whiskers when present. Furthermore, it is demonstrated how improper techniques can easily obscure detection. It is hoped that these videos will improve the probability of detecting metal whiskers with optical inspection techniques.

Brusse, Jay A.↗

Large-Scale CT Inspection of Feed-Through EMI Filters for Space Application

A type of Feed-Through Electromagnetic Interference (EMI) Filter incorporating two discoidal (ring-shaped) capacitors was selected for use in the Europa Clipper spacecraft propulsion systems. Parts reliability specialists were aware of historical problems with the attach materials used to provide mechanical support and electrical contact within these devices, so therefore a screening was desired to ensure the longevity and ruggedness of units intended for the space environment. CT X-ray, a technology which has become more widely available thanks to the compelling depth of information it offers, was selected as the inspection method of choice.

Bescup, John C↗

The ERDA/LeRC Photovoltaic Systems Test Facility

The ERDA/LeRC Photovoltaic Systems Test Facility (STF) provides a vital support function to the overall ERDA National Solar Photovoltaic Program. It allows preliminary investigation and checkout of components, subsystems, and complete photovoltaic systems before installation in actual service. The STF can also be used to determine optimum system configurations and operating modes. A facility description is presented, taking into account the solar cell array, the energy storage equipment, the power conditioning equipment, electric utility distribution network and loads, and instrumentation and data acquisition systems. Safety procedures which have been set up for maintenance and inspection of the solar array are discussed. Attention is also given to a number of investigations regarding the effect of environmental factors on solar cell array operation.

Forestieri, A. F.↗