Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRO-OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Displays, memories, and signal processing: A compilation

Articles on electronics systems and techniques were presented. The first section is on displays and other electro-optical systems; the second section is devoted to signal processing. The third section presented several new memory devices for digital equipment, including articles on holographic memories. The latest patent information available is also given.

Source record↗

The Corralitos Observatory program for the detection of lunar transient phenomena

This is a final report on the establishment, observing procedures, and observational results of a survey program for the detection of lunar transient phenomena (LTP's) by electro-optical image conversion means. For survey, a unique detection system with an image orthicon was used as the primary element in conjunction with a 24-in. f/20 Cassegrainian telescope. Observations in three spectral ranges, with 6,466 man-hours of observing, were actually performed during the period from October 27, 1965, to April 26, 1972. Within this entire period, no color or feature change within the detection capabilities of the instrumentation was observed, either independently or in follow up of amateur LTP reports, with the exception of one general bluing and several localized bluings (probably ascribable to the effects of the terrestrial atmosphere) that were observed solely by the Corralitos system. A table is presented indicating amateur and professional reports of LTP's and the results of efforts to confirm these reports through the Corralitos system.

Hynek, J. A.↗

Polarization compensator for optical communications

An optical data communication system is provided whereby two orthogonal polarization states of a light beam carrier correspond to digital states. In such a system, automatic polarization compensation is provided by applying a dither modulating voltage to a cell exhibiting the electro-optic effect. The cell controls the relative phase of electric field components of an input light beam enabling the dither frequency component of the difference of the instantaneous powers in the two polarization states to be coherently detected. A signal derived from the coherent detection process is fed back to the cell via an integrator to form polarization bias compensating servo loop ot Type 1.

Fitzmaurice, M. W.↗

Optical storage in lithium niobate

Holographic storage and retrieval using photorefractive media (electro-optic ferroelectric materials), particularly iron-doped lithium niobate with its enhanced sensitivity, are discussed. Refractive index changes induced by exposure to light render the materials useful for read-write memories and read-write memory simulation. Resolution, dark storage time, write and erase times, reversibility, and noise levels of the materials are examined. The laser source, deflection system, hololens, page composer, and detector array of the holographic memory system are described. High SNR and two orders of magnitude improvement in speed are reported over earlier experimental prototypes, but the system is still too slow to meet practical needs.

Alphonse, G. A.↗

A real-time optical data processing device

A novel liquid-crystal electro-optical device useful as a real-time input device in coherent optical data processing is described. The device is a special adaptation of an ac photoactivated liquid-crystal light valve, and utilizes a hybrid field effect (45 deg twisted nematic effect in OFF state and pure optical birefringence of the liquid crystal in ON state). A thin-film sandwich exerts photoelectric control over the optical birefringence of a thin liquid-crystal layer. Liquid-crystal layer thickness is successfully reduced without image degradation. The device offers high resolution (better than 100 lines/mm), contrast (better than 100/1), high speed (10 msec ON, 15 msec OFF), high input sensitivity, low power input, low fabrication cost, and can be operated at below 10 V rms. Preliminary measurements on device performance in level slicing, filtering, contrast reversal, and edge enhancement are under way.

Jacobson, A.↗

Results of the asteroid-meteoroid particle experiment on Pioneer 11

The Asteroid-Meteoroid Detector, an electro-optical instrument that detects and measures particles in space by sensing the sunlight reflected from them, is part of the payload of both the Pioneer 10 and 11 spacecraft. The Pioneer 11 instrument is essentially identical to that on Pioneer 10, with some minor modifications. Reduction of the Pioneer 11 data was complicated by the failure of one of the four sensor channels at about 1.1 AU from the sun. Detailed analysis yielded 51 events between 1.0 and 3.5 AU, which were used to determine the particle concentration distribution in that region of space. Weighted curve-fitting of the results shows agreement with the concentrations derived from Pioneer 10 to within about a factor of two. As with the Pioneer 10 results, the exponent of the size dependency varies from about -1.7 for 100-micron radius particles to about -3.2 for 10-cm bodies. The instrument, its operation, and the method of data analysis are reviewed.

Soberman, R. K.↗

Development of a monolithic GaAs integrated optical transmitter

The paper discusses a program designed for the development of a GaAs IOC transmitter consisting of a monolithic surface laser whose output is coupled into patterned channel waveguides. Modulation and switching of the radiation occur in the waveguide circuit and are controlled separately. These structures are to be fabricated monolithically on a single semiconductor chip with each device amenable to integrated low-cost manufacture. The waveguide outputs of the IOC transmitter will be coupled to single mode optical fibers which form a transmission cable. The properties of the semiconductors (Ga,Al)As and (Ga,In)As permit performance of each of the basic functions included in the device considered. The concept of monolithic nondiscrete GaAs diode lasers is examined along with optical stripline channel waveguides and electro-optic channel waveguide modulators and switches.

Blum, F. A.↗

Monitoring Air Pollution from Satellites (MAPS). Volume 1: Technical report

Performance tests on an electro-optical model of an infrared sensor for remote measurements of trace atmospheric gases are detailed; the instrument utilized a sample of the gas to be measured as spectral filter. Also reported is the development of radiometric calibration equipment that determines responses to simulated pollution effects. Results show excellent agreement with theoretical performance predictions with the exception of nonuniform radiance responses. Balance stability to an accuracy better than the rms noise level was demonstrated for the EOM in both the NH3 and CO modes for a period of two days under laboratory conditions. Flight test results show that the temperature range of the absorption cell is restricted to 255 K or higher.

Source record↗

Photorefractive materials for optical storage and display

Real-time data storage and processing using optical techniques have been considered in recent years. Of particular interest are photosensitive electro-optic crystals which permit volume storage in the form of phase holograms, by means of a charge transfer process. A survey of the state of the art of such holographic memories is presented. The physical mechanism responsible for the formation of phase holograms in such crystals is discussed. Attention is focused on various aspects of materials characterization, development and utilization. Experimental reversible holographic read-write memory systems with fast random access and high storage capacity employing this new class of photosensitive materials have already been demonstrated.

Shah, R. R.↗

High sensitivity 1.06 micron optical receiver for precision laser range finding

Aluminum gallium antimonide avalanche photodiodes with average gain of 10, internal quantum efficiency of greater than 60%, capacitance less than 0.2pf, and dark current of less than 1 micron were designed and fabricated for use in a low noise optical receiver suitable for 2 cm accuracy rangefinding. Topics covered include: (1) design of suitable photodetector structures; (2) epitaxial growth of AlGaSb devices; (3) fabrication of photodetectors; and (4) electro-optics characterization.

Scholl, F. W.↗

Trade-off study of data storage technologies

The need to store and retrieve large quantities of data at modest cost has generated the need for an economical, compact, archival mass storage system. Very significant improvements in the state-of-the-art of mass storage systems have been accomplished through the development of a number of magnetic, electro-optical, and other related devices. This study was conducted in order to do a trade-off between these data storage devices and the related technologies in order to determine an optimum approach for an archival mass data storage system based upon a comparison of the projected capabilities and characteristics of these devices to yield operational systems in the early 1980's.

Kadyszewski, R. V.↗

The Addition of EI/CI Capability to the Mattauch-herzog Spectrograph with EOID

A modification was made to the Mattauch-Herzog Spectrograph with an electro-optical ion detector (EOID) previously designed and constructed, so that it would be capable of operating not only in the electron-impact (EI) mode of ionization, but also in the chemical ionization (CI) mode. This modification necessitated an effort in three specific design areas: (1) sample inlet; (2) ion source and analyzer regions; and (3) the pumping system. In addition, an appropriate electronics package had to be designed to control and operate the combined EI/CI source.

Fergusson, G. J.↗

Vision Test in Seconds

Acuity Systems, Inc. developed an electro-optical instrument under a grant from NASA to measure the visual performance of pilots. Transferred from Ames Research Center, this instrument now allows you to have your eyes tested in seconds by relatively unskilled operators. The device automatically measures refractive error of eye and prints out proper prescription for glasses. The unit also detects cataracts and glaucoma.

Source record↗

Lead Poison Detection

With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

Source record↗

Microbe Detector

The AutoMicrobic System (AMS) represents years of intensive research and development by McDonnell Douglas Corp. that originated with a NASA study aimed at development of a fully automated microbial detection and identification system for spacecraft use. A urine specimen is placed into the system, where it is subjected to different freeze-dried microbe nutrients for the nine most common pathogens. An electro-optical scanner studies each specimen once an hour through a 4-to-13 hour cycle, operating automatically. Changes in cell growths on each culture are monitored by computer. The presence of pathogens is indicated when growth reaches a predetermined level. The system also enumerates the pathogens and specifies the type. Developed initially to handle urine testing, AMS soon is expected to allow analyses of blood, spinal fluid, and other body fluids. An additional capability under development is "susceptibility testing," or the determination of which microbe-killing agents-such as penicillin or other antibiotics-would be most effective in eliminating the pathogens. The whole process of detecting, identifying, and enumerating the pathogens and determining susceptibility is accomplished in less half the time required for the manual procedure. The AMS minimizes human error, reduces technician time , and increases laboratory output.

Source record↗

A Method of Monitoring Non-Resonant Raman Lidar Returns During Daylight Hours

A method for using non-resonant Raman lidar during daytime hours is presented. A dual (or quadruple) arrangement of electro-optical channels is set up in the lidar receiver. Each channel contains its own optical spectral response as determined by an appropriate set of interference filters. The incoming signal is split and fed into two channels, filtered (simultaneously) and then inserted into the input terminals of an operational amplifier. The difference signal is selected and amplified whereas the common portion of the signal is highly attenuated (Common Mode Re.jection Ratio = 75-80db). For the present hardware, daylight intensities 10(exp 2)-10(exp 3) times Raman signals are received simultaneously. Mean values of intensities of daylight signals which give rise to a constant differences merely shift the value of the measured variable at the ground. These mean value signals have their common part highly attenuated. The differences of the fluctuation portions of the daylight signal represents a noise signal. Identical (space-time) optical paths for each component of the daylight signal produce the same fluctuational spectra in each channel. Hence noise levels, much less than signal levels, are anticipated. First a N2-H2 ) signal pair is differenced. Then an N2-O2 pair is differenced and used for instrumental normalization purposes. Signal levels to be encountered are quite well known as a result of prior field work. Improved optical design of laser system can reduce mean value of daylight intensities by 10(exp 2). Thus the mean daylight intensity can be set equal to the expected signal levels by more advanced optical design. Performance characteristics of photomultiplier pairs are discussed in this connection.

Cooney, John↗