Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETISM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Growth stimulation of biological cells and tissue by electromagnetic fields and uses thereof

The present invention provides systems for growing two or three dimensional mammalian cells within a culture medium facilitated by an electromagnetic field, and preferably, a time varying electromagnetic field. The cells and culture medium are contained within a fixed or rotating culture vessel, and the electromagnetic field is emitted from at least one electrode. In one embodiment, the electrode is spaced from the vessel. The invention further provides methods to promote neural tissue regeneration by means of culturing the neural cells in the claimed system. In one embodiment, neuronal cells are grown within longitudinally extending tissue strands extending axially along and within electrodes comprising electrically conductive channels or guides through which a time varying electrical current is conducted, the conductive channels being positioned within a culture medium.

Wolf, David A.↗

Electromagnetic Forces in a Hybrid Magnetic-Bearing Switched-Reluctance Motor

Analysis and experimental measurement of the electromagnetic force loads on the hybrid rotor in a novel hybrid magnetic-bearing switched-reluctance motor (MBSRM) have been performed. A MBSRM has the combined characteristics of a switched-reluctance motor and a magnetic bearing. The MBSRM discussed in this report has an eight-pole stator and a six-pole hybrid rotor, which is composed of circular and scalloped lamination segments. The hybrid rotor is levitated using only one set of four stator poles, while a second set of four stator poles imparts torque to the scalloped portion of the rotor, which is driven in a traditional switched reluctance manner by a processor. Static torque and radial force analysis were done for rotor poles that were oriented to achieve maximum and minimum radial force loads on the rotor. The objective is to assess whether simple one-dimensional magnetic circuit analysis is sufficient for preliminary evaluation of this machine, which may exhibit strong three-dimensional electromagnetic field behavior. Two magnetic circuit geometries, approximating the complex topology of the magnetic fields in and around the hybrid rotor, were employed in formulating the electromagnetic radial force equations. Reasonable agreement between the experimental and the theoretical radial force loads predictions was obtained with typical magnetic bearing derating factors applied to the predictions.

Morrison, Carlos R.↗

Comparisons in Performance of Electromagnet and Permanent-Magnet Cylindrical Hall-Effect Thrusters

Three different low-power cylindrical Hall thrusters, which more readily lend themselves to miniaturization and low-power operation than a conventional (annular) Hall thruster, are compared to evaluate the propulsive performance of each. One thruster uses electromagnet coils to produce the magnetic field within the discharge channel while the others use permanent magnets, promising power reduction relative to the electromagnet thruster. A magnetic screen is added to the permanent magnet thruster to improve performance by keeping the magnetic field from expanding into space beyond the exit of the thruster. The combined dataset spans a power range from 50-350 W. The thrust levels over this range were 1.3-7.3 mN, with thruster efficiencies and specific impulses spanning 3.5-28.7% and 400-1940 s, respectively. The efficiency is generally higher for the permanent magnet thruster with the magnetic screen, while That thruster s specific impulse as a function of discharge voltage is comparable to the electromagnet thruster.

Polzin, K. A.↗

Modeling Electromagnetic Scattering From Complex Inhomogeneous Objects

This software innovation is designed to develop a mathematical formulation to estimate the electromagnetic scattering characteristics of complex, inhomogeneous objects using the finite-element-method (FEM) and method-of-moments (MoM) concepts, as well as to develop a FORTRAN code called FEMOM3DS (Finite Element Method and Method of Moments for 3-Dimensional Scattering), which will implement the steps that are described in the mathematical formulation. Very complex objects can be easily modeled, and the operator of the code is not required to know the details of electromagnetic theory to study electromagnetic scattering.

Deshpande, Manohar↗

Electromagnetic Launch Vehicle Fairing and Acoustic Blanket Model of Received Power Using FEKO

Evaluating the impact of radio frequency transmission in vehicle fairings is important to electromagnetically sensitive spacecraft. This study employs the multilevel fast multipole method (MLFMM) from a commercial electromagnetic tool, FEKO, to model the fairing electromagnetic environment in the presence of an internal transmitter with improved accuracy over industry applied techniques. This fairing model includes material properties representative of acoustic blanketing commonly used in vehicles. Equivalent surface material models within FEKO were successfully applied to simulate the test case. Finally, a simplified model is presented using Nicholson Ross Weir derived blanket material properties. These properties are implemented with the coated metal option to reduce the model to one layer within the accuracy of the original three layer simulation.

Trout, Dawn H.↗

Short Wavelength Electromagnetic Perturbations Excited Near the Solar Probe Plus Spacecraft in the Inner Heliosphere: 2.5D Hybrid Modeling

A 2.5D numerical plasma model of the interaction of the solar wind (SW) with the Solar Probe Plus spacecraft (SPPSC) is presented. These results should be interpreted as a basic plasma model derived from the SW-interaction with the spacecraft (SC), which could have consequences for both plasma wave and electron plasma measurements on board the SC in the inner heliosphere. Compression waves and electric field jumps with amplitudes of about 1.5 V/m and (12-18) V/m were also observed. A strong polarization electric field was also observed in the wing of the plasma wake. However, 2.5D hybrid modeling did not show excitation of whistler/Alfven waves in the upstream connected with the bidirectional current closure that was observed in short-time 3D modeling SPPSC and near a tether in the ionosphere. The observed strong electromagnetic perturbations may be a crucial point in the electromagnetic measurements planned for the future Solar Probe Plus (SPP) mission. The results of modeling electromagnetic field perturbations in the SW due to shot noise in absence of SPPSC are also discussed.

Lipatov, Alexander S.↗

Electromagnetic Characterization Of Metallic Sensory Alloy

Ferromagnetic shape-memory alloy (FSMA) particles undergo changes in both electromagnetic properties and crystallographic structure when strained. When embedded in a structural material, these attributes can provide sensory output of the strain state of the structure. In this work, a detailed characterization of the electromagnetic properties of a FSMA under development for sensory applications is performed. In addition, a new eddy current probe is used to interrogate the electromagnetic properties of individual FSMA particles embedded in the sensory alloy during controlled fatigue tests on the multifunctional material.

Wincheski, Russell A.↗

International Space Station-Based Electromagnetic Launcher for Space Science Payloads

A method was developed of lowering the cost of planetary exploration missions by using an electromagnetic propulsion/launcher, rather than a chemical-fueled rocket for propulsion. An electromagnetic launcher (EML) based at the International Space Station (ISS) would be used to launch small science payloads to the Moon and near Earth asteroids (NEAs) for the science and exploration missions. An ISS-based electromagnetic launcher could also inject science payloads into orbits around the Earth and perhaps to Mars. The EML would replace rocket technology for certain missions. The EML is a high-energy system that uses electricity rather than propellant to accelerate payloads to high velocities. The most common type of EML is the rail gun. Other types are possible, e.g., a coil gun, also known as a Gauss gun or mass driver. The EML could also "drop" science payloads into the Earth's upper

Jones, Ross M.↗

Scattering and Diffraction of Electromagnetic Radiation: An Effective Probe to Material Structure

Scattered electromagnetic waves from material bodies of different forms contain, in an intricate way, precise information on the intrinsic, geometrical and physical properties of the objects. Scattering theories, ever deepening, aim to provide dependable interpretation and prediction to the complicated interaction of electromagnetic radiation with matter. There are well-established multiple-scattering formulations based on classical electromagnetic theories. An example is the Generalized Multi-particle Mie-solution (GMM), which has recently been extended to a special version ̶ the GMM-PA approach, applicable to finite periodic arrays consisting of a huge number (e.g., >>106) of identical scattering centers [1]. The framework of the GMM-PA is nearly complete. When the size of the constituent unit scatterers becomes considerably small in comparison with incident wavelength, an appropriate array of such small element volumes may well be a satisfactory representation of a material entity having an arbitrary structure. X-ray diffraction is a powerful characterization tool used in a variety of scientific and technical fields, including material science. A diffraction pattern is nothing more than the spatial distribution of scattered intensity, determined by the distribution of scattering matter by way of its Fourier transform [1]. Since all linear dimensions entered into Maxwell's equations are normalized by wavelength, an analogy exists between optical and X-ray diffraction patterns. A large set of optical diffraction patterns experimentally obtained can be found in the literature [e.g., 2,3]. Theoretical results from the GMM-PA have been scrutinized using a large collection of publically accessible, experimentally obtained Fraunhofer diffraction patterns. As far as characteristic structures of the patterns are concerned, theoretical and experimental results are in uniform agreement; no exception has been found so far. Closely connected with the spatial distribution of scattered intensities are cross sections, such as for extinction, scattering, absorption, and radiation pressure, as a critical type of key quantity addressed in most theoretical and experimental studies of radiative scattering. Cross sections predicted from different scattering theories are supposed to be in general agreement. For objects of irregular shape, the GMM-PA solutions can be compared with the highly flexible Discrete Dipole Approximation (DDA) [4,5] when dividing a target to no more than ~106 unit cells. Also, there are different ways to calculate the cross sections in the GMM-PA, providing an additional means to examine the accuracy of the numerical solutions and to unveil potential issues concerning the theoretical formulations and numerical aspects. To solve multiple scattering by an assembly of material volumes through classical theories such as the GMM-PA, the radiative properties of the component scatterers, the complex refractive index in particular, must be provided as input parameters. When using a PA to characterize a material body, this involves the use of an adequate theoretical tool, an effective medium theory, to connect Maxwell's phenomenogical theory with the atomistic theory of matter. In the atomic theory, one regards matter as composed of interacting particles (atoms and molecules) embedded in the vacuum [6]. However, the radiative properties of atomic-scaled particles are known to be substantially different from bulk materials. Intensive research efforts in the fields of cluster science and nanoscience attempt to bridge the gap between bulk and atom and to understand the transition from classical to quantum physics. The GMM-PA calculations, which place virtually no restriction on the component-particle size, might help to gain certain insight into the transition.

Xu, Yu-Lin↗

System for Transmitting and Receiving Electromagnetic Radiation

A system for transmitting and receiving electromagnetic radiation includes a beam splitter and a transceiver. The beam splitter is configured to separate an optical pulse into a pump pulse and a probe pulse. The transceiver may include a transmitter switch and a receiver switch. The pump pulse is directed toward the transmitter switch and the probe pulse is directed towards the receiver switch. Electromagnetic radiation is emitted from the transceiver when the pump pulse strikes the transmitter switch. The electromagnetic radiation may be terahertz radiation in either a pulsed or continuous wave form.

Strong, Timothy↗

Electromagnetic Redesign of NASA’s High Efficiency Megawatt Motor

NASA’s High Efficiency Megawatt Motor (HEMM) is being developed to achieve the performance needed by single aisle class electrified aircraft. It is a 1.4 MW electric machine designed as a generator for NASA’s STARC-ABL concept vehicle. It has performance objectives of greater than 16 kW/kg electromagnetic specific power and efficiency of greater than 98%. A significant flaw in the preliminary electromagnetic design of HEMM was recently discovered. The stator teeth in the preliminary design cause the magnetic flux in the rotating components of HEMM to oscillate at a very high frequency (12,240 Hz). Two independent energy loss analyses are presented to show that the frequency is high enough to cause eddy current losses that significantly exceed the rotor’s loss limit (50 W), despite the very small magnitude of this flux oscillation (<0.01 T). To eliminate these rotor losses, while continuing to meet the target performance, it was determined that the stator teeth needed to be removed and the electromagnetic geometry of the motor needed to be revised. The revised, slotless HEMM motor design is summarized. Sensitivity of the new design to key unknown variables such as the temperature of and number of turns in the superconducting rotor coils and the stator winding’s average temperature.

Thomas T Tallerico↗

Electromagnetic Pain Relief/Blocking: Feasibility Assessment

Context/Background: Astronauts use pharmaceuticals during spaceflight to manage acute and chronic pain, but use of analgesics will have drawbacks for exploration-class missions because the shelf life of these medications is limited, resupply will be curtailed, astronauts may develop tolerance and/or addiction to these medications, and side effects can include impairment of cognitive abilities. Electromagnetic devices have been developed that treat pain terrestrially by affecting neuromodulation–dubbed “electroceuticals”, these devices have varied mechanisms of action that either stimulate or suppress neural activity in the central nervous system or peripheral nerves. Objective/Purpose: The available literature was reviewed and FDA-approved pain treatments (both pharmacological and non-pharmacological), as well as those currently under development, were assessed for their suitability for use in exploration class spaceflight missions. Data Sources: Due to the COVID-19 pandemic and the resulting closure of libraries, data sources were restricted to those available digitally. Online database searches included PubMed, U.S. Patent and Trademark Office, federal grant award databases (National Aeronautics and Space Administration (NASA), Department of Defense (DoD), National Institutes of Health (NIH)), and general internet searches. More than 1,600 records were reviewed in this effort. Study Selection/Eligibility Criteria: Targeted searches included different aspects of pain management. Priority was given to review studies, to cover as much of the available literature as possible in this limited effort. Study Appraisal and Synthesis Methods/Data Extraction and Data Synthesis: The titles of the studies and the awards that were obtained by searching online databases were reviewed and further information was sought for the relevant titles. Abstracts or award summaries were generally available online; for journal abstracts, full text articles were either available online or were requested via interlibrary loan. Results: An overwhelming majority of the literature focuses on the treatment of chronic rather than acute pain because it is assumed that acute pain only rarely fails to resolve and instead transitions into chronic pain when the central nervous system becomes hypersensitized. The available electromagnetic devices marketed for pain treatment have varying levels of invasiveness, use different mechanisms of action, and have demonstrated varying efficacy when evaluated scientifically. A truly noninvasive, highly efficient device is desired for use during spaceflight. One portable, self-contained, FDA-approved device was identified that, from preliminarily assessment, best met these criteria; the device noninvasively applies pulsed shortwave therapy (PSWT) to modify pain signals from peripheral nerves, however, the device has limited battery life and the effects are relatively non-selective in type of neural signal modified. Limitations: This current effort, although extensive, did not identify a comprehensive list of all alternatives for pain treatment. Once the pandemic limitations are lifted, a longer, more thorough effort may find additional options. Conclusions/Implications: The ideal electromagnetic pain treatment device for use on exploration-class spaceflight missions does not yet exist, but it may be available soon. It is not feasible for NASA to develop medical devices due to the schedule constraints for pending exploration-class missions, but adapting a promising device that is already FDA-approved might be an option. Monitoring research that is ongoing at other federal agencies is recommended, and further review of the candidate PSWT device identified in this current effort may be warranted.

Carol Mullenax↗

Electromagnetic Pain Relief/Blocking: Feasibility Assessment

CONTEXT/BACKGROUND Astronauts use pharmaceuticals during spaceflight to manage acute and chronic pain, but use of analgesics will have drawbacks for exploration-class missions because the shelf life of these medications is limited, resupply will be curtailed, astronauts may develop tolerance and/or addiction to these medications, and side effects can include impairment of cognitive abilities. Electromagnetic devices have been developed that treat pain terrestrially by affecting neuromodulation–dubbed “electroceuticals”, these devices have varied mechanisms of action that either stimulate or suppress neural activity in the central nervous system or peripheral nerves. OBJECTIVE/PURPOSE The available literature was reviewed and FDA-approved pain treatments (both pharmacological and non-pharmacological), as well as those currently under development, were assessed for their suitability for use in exploration class spaceflight missions. DATA SOURCES Due to the COVID-19 pandemic and the resulting closure of libraries, data sources were restricted to those available digitally. Online database searches included PubMed, U.S. Patent and Trademark Office, federal grant award databases (National Aeronautics and Space Administration (NASA), Department of Defense (DoD), National Institutes of Health (NIH)), and general internet searches. More than 1,600 records were reviewed in this effort. STUDY SELECTION/ELIGIBILITY CRITERIA Targeted searches included different aspects of pain management. Priority was given to review studies, to cover as much of the available literature as possible in this limited effort. STUDY APPRAISAL AND SYNTHESIS METHODS/DATA EXTRACTION AND DATA SYNTHESIS The titles of the studies and the awards that were obtained by searching online databases were reviewed and further information was sought for the relevant titles. Abstracts or award summaries were generally available online; for journal abstracts, full text articles were either available online or were requested via interlibrary loan. RESULTS An overwhelming majority of the literature focuses on the treatment of chronic rather than acute pain because it is assumed that acute pain only rarely fails to resolve and instead transitions into chronic pain when the central nervous system becomes hypersensitized. The available electromagnetic devices marketed for pain treatment have varying levels of invasiveness, use different mechanisms of action, and have demonstrated varying efficacy when evaluated scientifically. A truly noninvasive, highly efficient device is desired for use during spaceflight. One portable, self-contained, FDA-approved device was identified that, from preliminarily assessment, best met these criteria; the device noninvasively applies pulsed shortwave therapy (PSWT) to modify pain signals from peripheral nerves, however, the device has limited battery life and the effects are relatively non-selective in type of neural signal modified. LIMITATIONS This current effort, although extensive, did not identify a comprehensive list of all alternatives for pain treatment. Once the pandemic limitations are lifted, a longer, more thorough effort may find additional options. CONCLUSIONS/IMPLICATIONS The ideal electromagnetic pain treatment device for use on exploration-class spaceflight missions does not yet exist, but it may be available soon. It is not feasible for NASA to develop medical devices due to the schedule constraints for pending exploration-class missions, but adapting a promising device that is already FDA-approved might be an option. Monitoring research that is ongoing at other federal agencies is recommended, and further review of the candidate PSWT device identified in this current effort may be warranted.

C A Mullenax↗

Electromagnetic Compatibility Test and Analysis Campaign of NASA's Mars 2020 Rover

NASA's Mars 2020 Rover—with a launch window opening July 2020, and landing expected February 2021—has mission objectives to look for evidence of habitability, seek biosignatures of past life, collect and cache samples for possible future return to Earth, and prepare for future human missions. The Rover platform is similar to the previous Mars Science Laboratory (MSL) “Curiosity” rover that landed in 2012 but contains a new suite of scientific instruments and upgrades to existing functionality. The scientific payload includes a trio of chemical analysis tools (PIXL, SHERLOC, SuperCam), a ground penetrating radar (RIMFAX), an upgraded weather station (MEDA), upgraded high resolution camera (MastCam-Z), and an oxygen-producing experiment (MOXIE). These changes—along with new efficiency goals to operate more Rover subsystems concurrently and thus collect more science—presented new electromagnetic compatibility (EMC) challenges. In this paper, we will describe the campaign to ensure Mars 2020 mission success from an electromagnetic environment perspective: 1) confirming existing MSL heritage subsystems and EMC requirements were compatible with the new Mars 2020 mission objectives, 2) engaging with engineers and scientists early in the project to identify and evaluate risks before hardware assembly and performing ambitious risk reduction tests, 3) undertaking a comprehensive subsystem qualification test program based on tailored MIL-STD-461F requirements, occasionally leading to redesign, 4) synthesizing the data collected to perform detailed analyses toward the goal of making risk-informed decisions at a system level. The spacecraft has successfully completed all three planned system level tests, demonstrating self-compatibility with minimal impact to operations from electromagnetic interference in all mission phases.

Gonzales, Edward C↗

SelenITA: A dual-spacecraft lunar CubeSat mission to characterize the near-surface electromagnetic plasma environment

SelenITA is an international interdisciplinary mission consisting of two CubeSats that will provide the first multi-point measurement in a sustained low lunar orbit. This mission will advance the understanding of spatiotemporal differentiation of the electromagnetic space environment at the Moon in support of Artemis crew and the geosciences. The mission science objectives are to: (1) further constrain the origins of crustal magnetic fields and their applications; (2) determine the nature of plasma interactions with crustal magnetic fields; (3) characterize plasma waves and turbulence at the Moon; (4) characterize the lunar surface potential in all plasma environments; (5) constrain the composition, thermal state, and structure of the lunar upper mantle and crust; (6) characterize the ionizing radiation in lunar orbit; (7) determine the density of the dust exosphere as a function of latitude, longitude, and altitude, including the lunar polar space environment. The measurement requirements include: 3-component vector magnetic field, plasma distribution (flux, energy, density, temperature), energetic particles (protons, electrons, gamma rays), and dust. SelenITA builds on a rich history of electromagnetic plasma observations of the near lunar surface and space environment, and it answers high level science questions with state of the art instruments in a small package. PLAIN LANGUAGE ABSTRACT – SelenITA comes from the greek word for Moon, selene, with the addition of “ITA” as a reference to the Brazilian teammate, Instituto Tecnológico de Aeronáutica. In addition, in Portuguese "ita" is a prefix similar to "ite" in English, used in naming minerals, so Selenita could be seen as a lunar gemstone. In Spanish, “ita” is a diminutive suffix for “little” which is appropriate for this CubeSat mission which consists of twin 12U CubeSats in low lunar orbit. The primary science goal of the mission is to distinguish time varying features within the electromagnetic plasma environment near the surface of the Moon. The science objectives include investigating the origins of crustal magnetic fields, plasma interactions with these fields, plasma waves, surface potential, and interior properties. This mission is also interested in the radiation environment at the Moon and the amount of dust at the lunar poles. This is important because it helps us understand how future astronauts will live and work on the lunar surface and identify hazards.

space weather↗

SelenITA: A Dual-Spacecraft Lunar CubeSat Mission to Characterize the Near-Surface Electromagnetic Plasma Environment

SelenITA is an international interdisciplinary mission consisting of two CubeSats that will provide the first multi-point measurement in a sustained low lunar orbit. This mission will advance the understanding of spatiotemporal differentiation of the electromagnetic space environment at the Moon in support of Artemis crew and the geosciences. The mission science objectives are to: (1) further constrain the origins of crustal magnetic fields and their applications; (2) determine the nature of plasma interactions with crustal magnetic fields; (3) characterize plasma waves and turbulence at the Moon; (4) characterize the lunar surface potential in all plasma environments; (5) constrain the composition, thermal state, and structure of the lunar upper mantle and crust; (6) characterize the ionizing radiation in lunar orbit; (7) determine the density of the dust exosphere as a function of latitude, longitude, and altitude, including the lunar polar space environment. The measurement requirements include: 3-component vector magnetic field, plasma distribution (flux, energy, density, temperature), energetic particles (protons, electrons, gamma rays), and dust. SelenITA builds on a rich history of electromagnetic plasma observations of the near lunar surface and space environment, and it answers high level science questions with state of the art instruments in a small package. PLAIN LANGUAGE ABSTRACT – SelenITA comes from the greek word for Moon, selene, with the addition of “ITA” as a reference to the Brazilian teammate, Instituto Tecnológico de Aeronáutica. In addition, in Portuguese "ita" is a prefix similar to "ite" in English, used in naming minerals, so Selenita could be seen as a lunar gemstone. In Spanish, “ita” is a diminutive suffix for “little” which is appropriate for this CubeSat mission which consists of twin 12U CubeSats in low lunar orbit. The primary science goal of the mission is to distinguish time varying features within the electromagnetic plasma environment near the surface of the Moon. The science objectives include investigating the origins of crustal magnetic fields, plasma interactions with these fields, plasma waves, surface potential, and interior properties. This mission is also interested in the radiation environment at the Moon and the amount of dust at the lunar poles. This is important because it helps us understand how future astronauts will live and work on the lunar surface and identify hazards.

space weather↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor - Extended Abstract

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD↗