Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Ground-state energies of simple metals

A structural expansion for the static ground-state energy of a simple metal is derived. Two methods are presented, one an approach based on single-particle band structure which treats the electron gas as a nonlinear dielectric, the other a more general many-particle analysis using finite-temperature perturbation theory. The two methods are compared, and it is shown in detail how band-structure effects, Fermi-surface distortions, and chemical-potential shifts affect the total energy. These are of special interest in corrections to the total energy beyond third order in the electron-ion interaction and hence to systems where differences in energies for various crystal structures are exceptionally small. Preliminary calculations using these methods for the zero-temperature thermodynamic functions of atomic hydrogen are reported.

Hammerberg, J.↗

THE STRUCTURE FUNCTION OF THE FREE NEUTRON AT HIGH X-BJORKEN

Understanding the internal structure of nucleons is one of the primary goal of nuclear physicists. As protons and neutrons are only the bound state solution of the QCD lagrangian (at least inside atomic nuclei), studying protons and neutrons helps uncover nuclear struc ture. Due to its easy availability, many studies on protons have been done on a wide range of kinematics. However, free neutron targets are not readily achievable. So, any information on neutrons has to be extracted from neutron-rich nuclei, and some nuclear models have to be used to subtract the contributions from other nucleons to extract the information on neutrons. So, the Barely Off-shell Nucleon Structure (BONuS12) experiment at Jefferson Lab was conducted to overcome these challenges by using spectator tagging. The experiment effectively created a quasi-free neutron target by scattering electrons off a deuterium target and detecting low-momentum, backward-moving protons using a custom-built Radial Time Projection Chamber (RTPC). Selecting the low momentum and backward-moving spectators would enable us to minimize the model-dependent effects due to final state interactions and target fragmentation. The RTPC was a 40 cm-long cylindrical detector that works on the principle of gaseous ionization. It had three layers of Gas Electron Multipliers (GEMs) for charge amplification and a surrounding readout pad. The scattered electrons were measured using the CLAS12 detector, and data were collected using a 10.4 GeV electron beam dur ing Spring and Summer 2020. Using spectator tagging, we extracted the structure function ratio Fn 2 of the quasi-free neutron in the deep inelastic scattering at high x, upto x ~ 0.8. The result was extracted in the region with the invariant mass W > 1.8 GeV/c2, and Q2 in the range 1.3 to 11 GeV2. This dissertation presents the methodology, event selection criteria and refinements, estimation and subtraction of backgrounds, and complete analysis of extraction of Fn 2/Fp 2 in a model-independent way. Also, systematic uncertainties in our final analysis will be discussed in detail.

Pokhrel, Madhusudhan [Old Dominion Univ., Norfolk,↗

Measurement of the Neutron Magnetic Form Factor at Large Momentum Transfer Using the Super-Bigbite Apparatus in Jefferson Lab Hall-A

The nucleon elastic electromagnetic form factors help us study the electromagnetic structure of the nucleon, benchmark theoretical models, and improve our understanding of non-perturbative quantum chromodynamics and confinement. The Nobel Prize-winning electron-nucleon scattering experiments by Robert Hofstadter and collaborators in the 1950s at Stanford High Energy Physics Lab were the first nucleon form factor measurements performed using leptonic probes. The Super Bigbite Spectrometer (SBS) program at Hall-A of Jefferson Lab represents the latest efforts to measure nucleon form factors. This ambitious program aims to significantly extend the current data set in terms of square momentum transfer (Q2) with high precision. The advent of novel detector technologies, like Gas Electron Multipliers (GEM), which provide excellent position resolution (< 100 ?m) while withstanding high background particle rates (several hundred MHz/cm2) over a large active area, has paved the way for open-geometry, moderate solid angle spectrometers, which are central to all form factor experiments in the SBS program. The first experimental run group in SBS ran successfully between September 2021 and February 2022, collecting data for the measurement of the magnetic form factor of the neutron Gn M at five squared momentum-transfer values: 3.0, 4.5, 7.5, 9.8, and 13.5 (GeV /c)2. This extends the existing high-precision data for Gn M by about a factor of four. The ratio technique was used, which involved the simultaneous measurement of exclusive quasielastic scattering of D(e,e?n)p and D(e,e?p)n from a deuterium target. Pre-preliminary results for D(e,e?n)p and D(e,e?p)n quasi-elastic ratio, and the neutron magnetic form factor Gn M , for Q2 points 3.0, 9.8, and 13.5 (GeV /c)2 are presented.

Mudiyanselage, Anuruddha Rathnayake↗

Mixed Carrier Conduction in Modulation-doped Field Effect Transistors

The contribution of more than one carrier to the conductivity in modulation-doped field effect transistors (MODFET) affects the resultant mobility and complicates the characterization of these devices. Mixed conduction arises from the population of several subbands in the two-dimensional electron gas (2DEG), as well as the presence of a parallel path outside the 2DEG. We characterized GaAs/AlGaAs MODFET structures with both delta and continuous doping in the barrier. Based on simultaneous Hall and conductivity analysis we conclude that the parallel conduction is taking place in the AlGaAs barrier, as indicated by the carrier freezeout and activation energy. Thus, simple Hall analysis of these structures may lead to erroneous conclusions, particularly for real-life device structures. The distribution of the 2D electrons between the various confined subbands depends on the doping profile. While for a continuously doped barrier the Shubnikov-de Haas analysis shows superposition of two frequencies for concentrations below 10(exp 12) cm(exp -2), for a delta doped structure the superposition is absent even at 50% larger concentrations. This result is confirmed by self-consistent analysis, which indicates that the concentration of the second subband hardly increases.

Schacham, S. E.↗

Wide-bandwidth electron bolometric mixers - A 2DEG prototype and potential for low-noise THz receivers

This paper presents a new type of electron bolometric ('hot electron') mixer. We have demonstrated a 3 order-of-magnitude improvement in the bandwidth compared with previously known types of electron bolometric mixers, by using the two-dimensional electron gas (2DEG) medium at the heterointerface between AlGaAs and GaAs. We have tested both in-house MOCVD-grown material and MBE material, with similar results. The conversion loss (Lc) at 94 GHz is presently 18 dB for a mixer operating at 20 K, and calculations indicate that Lc can be decreased to about 10 dB in future devices. Calculated and measured curves of Lc versus P(LO), and I(DC), respectively, agree well. We argue that there are several different configurations of electron bolometric mixers, which will all show wide bandwidth, and that these devices are likely to become important as low-noise THz receivers in the future.

Yang, Jian-Xun↗

Interfacial charge transfer and its impact on transport properties of LaNiO 3 /LaFeO 3 superlattices

Charge transfer or redistribution at oxide heterointerfaces is a critical phenomenon, often leading to remarkable properties such as two-dimensional electron gas and interfacial ferromagnetism. Despite studies on LaNiO 3 /LaFeO 3 superlattices and heterostructures, the direction and magnitude of the charge transfer remain debated, with some suggesting no charge transfer due to the high stability of Fe 3+ (3d 5 ). Here, we synthesized a series of epitaxial LaNiO 3 /LaFeO 3 superlattices and demonstrated partial (up to ~0.5 e - /interface unit cell) charge transfer from Fe to Ni near the interface, supported by density functional theory simulations and spectroscopic evidence of changes in Ni and Fe oxidation states. The electron transfer from LaFeO 3 to LaNiO 3 and the subsequent rearrangement of the Fe 3d band create an unexpected metallic ground state within the LaFeO 3 layer, strongly influencing the in-plane transport properties across the superlattice. Moreover, we establish a direct correlation between interfacial charge transfer and in-plane electrical transport properties, providing insights for designing functional oxide heterostructures with emerging properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AlGaAs/GaAs quasi-bulk effect mixers: Analysis and experiments

The lowest noise temperature for any receiver in the 0.5 to 1 THz range has been achieved with the bulk InSb hot electron mixer, which unfortunately suffers from the problem of having a very narrow bandwidth (1-2 MHz). We have demonstrated a three order of magnitude improvement in the bandwidth of hot electron mixers, by using the two-dimensional electron gas (2DEG) medium at the hetero-interface between AlGaAs and GaAs. We have tested both inhouse MOCVD-grown material, and MBE materials, with similar results. The conversion loss (L(sub c)) at 94 GHz is presently 18 dB for a mixer operating at 20 K, and calculations indicate that L(sub c) can be decreased to about 10 dB in future devices. Calculated and measured curves of L(sub c), versus PLO and IDC, respectively, agree well. We argue that there are several different configurations of hot electron mixers, which will also show wide bandwidth, and that these devices are likely to become important as low-noise THz receivers in the future.

Yngvesson, K. S.↗

Electron confinement–induced plasmonic breakdown in metals

Plasmon resonance represents the collective oscillation of free electron gas density and enables enhanced light-matter interactions in nanoscale dimensions. Traditionally, the classical Drude model describes plasmonic excitation, wherein plasma frequency exhibits no spatial dispersion. Here, we show conclusive experimental evidence of the breakdown of plasmon resonance and a consequent metal-insulator transition in an ultrathin refractory plasmonic material, hafnium nitride (HfN). Epitaxial HfN thick films exhibit a low-loss and high-quality Drude-like plasmon resonance in the visible spectral range. However, as the film thickness is reduced to nanoscale dimensions, Coulomb interaction among electrons increases because of electron confinement, leading to the spatial dispersion of plasma frequency. With a further decrease in thickness, electrons lose their ability to shield the incident electric field, turning the medium into a dielectric. The observed metal-insulator transition might carry some signatures of Wigner crystallization and indicates that such transdimensional, between 2D and 3D, films can serve as a promising playground to study strongly correlated electron systems.

Science & Technology - Other Topics↗

Two Carrier Analysis of Persistent Photoconductivity in Modulation-Doped Structures

A simultaneous fit of Hall and conductivity data gives quantitative results on the carrier concentration and mobility in both the quantum well and the parallel conduction channel. In this study this method was applied to reveal several new findings on the effect of persistent photoconductivity (PPC) on free-carrier concentrations and mobilities. The increase in the two-dimensional electron-gas (2DEG) concentration is significantly smaller than the apparent one derived from single carrier analysis of the Hall coefficient. In the two types of structures investigated, delta doped and continuously doped barrier, the apparent concentration almost doubles following illumination, while analysis reveals an increase of about 20% in the 2DEG. The effect of PPC on mobility depends on the structure. For the sample with a continuously doped barrier the mobility in the quantum well more than doubles. This increase is attributed to the effective screening of the ionized donors by the large electron concentration in the barrier. In the delta doped barrier sample the mobility is reduced by almost a factor of 2. This decrease is probably caused by strong coupling between the two wells, as is demonstrated by self-consistent analysis.

Schacham, S. E.↗

A theory of neutral gas emissions from a plasma contactor and its effect on electrodynamic tether performance

An existing anisotropic anodic plasma contactor model is extended to include neutral gas emissions. Within the framework of the contactor model, the inclusion of external ionization leads to an integrodifferential equation. By choosing the ratio of the contactor radius to the neutral gas-electron ionization mean free path at the contactor exit as a suitable expansion parameter, an analytical expression for the current-voltage characteristic can be found. The performance of this contactor model is examined via a dynamic simulation model developed for electrodynamic tethers. Detailed models of the geomagnetic field and the ionosphere are used to create a realistic environment. The highly nonlinear contactor voltagle-current characteristic is incorporated into a circuit equation, which includes radiation impedance, and is solved along the tether's orbit. Results show that it is more effective to fully ionize the contactor gas internally, than to partially ionize it externally, and that based on the specific power for the tether system, the optimum gas to use is argon. In addition, the effect of the radiation impedance on tether system performance is examined.

Roy, R. I. S.↗

Crystallization of the Transdimensional Electron Liquid

Wigner crystallization of free electrons at room temperature has been explored theoretically for a new class of metallic ultrathin (transdimensional) materials whose properties can be controlled by their thickness. Our calculations of the melting surface, critical electron density and temperature explain consistently the experimental data reported previously. We show that by reducing the material thickness one can Wigner-crystallize free electrons at room temperature to get them pinned onto a two-dimensional triangular lattice of a supersolid inside of the crystalline material. Such a solid melts and freezes reversibly with increase and decrease of electron doping or temperature, whereby its resistivity behaves opposite to the free electron gas model predictions.

Wigner crystal↗

Measurement of the Neutron Elastic Electromagnetic Form Factor Ratio at Large Momentum Transfer

Exploring nucleon structure is vital both for understanding its origin and existence as well as for the advancement of the sciences. It helps us answer key questions such as how quark and gluon dynamics create 99% of the nucleon mass. Electron- nucleon scattering has been widely used for precision studies of the nucleon and nuclear structure since the Nobel Prize winning investigations by Robert Hofstadter and collaborators in the 1950s. These studies provide information about the spatial charge and current densities of the nucleon in terms of the electromagnetic form factors. The form factors are functions of four momentum transfer squared (Q2). Extending the electromagnetic form factor measurements to higher Q2 plays a critical role in furthering the understanding of nucleon structure. This motivated the Super BigBite Spectrometer (SBS) program at Jefferson Lab. The open nature of the spectrometers and the direct line of sight from the target to the tracking detector locations in experimental setups such as SBS creates high levels of background at the detectors. This necessitates the use of tracking detectors with high rate capability and good position resolution. Gas Electron Multiplier (GEM) detectors are an excellent choice for tracking detectors in such experiments. Understanding the performance of the GEM detectors is important not just for SBS experiments but also for future high-luminosity experiments. This thesis reports the exploratory results from the measurement of the neutron elastic electromagnetic form factor ratio (Gn E/Gn M) at high momentum transfer. A longitudinally polarized electron beam was scattered off a polarized 3He target, used as an effective polarized neutron target. In this experiment, the polarized 3He target achieved a world record polarization weighted luminosity at a beam current of 45 µA. Double spin asymmetry of the scattered neutron events is used to extract the neutron form factor ratio. Measurements were taken at Q2 = 3.0, 6.8, 9.8 (GeV/c)2. The lowest Q2 measurement is in good agreement with the existing world data, and the higher-Q2 measurements extend the Q2 reach well beyond the existing world data and are expected to remain unmatched for a long time.

Gamage, Vimukthi Haththotuwa [Univ. of Virginia, C↗

Role of mechanical stress localizations on the radiation hardness of AlGaN/GaN high electron mobility transistors

Multi-material, multi-layered systems such as AlGaN/GaN high electron mobility transistors (HEMTs) contain residual mechanical stresses that arise from sharp contrasts in device geometry and materials parameters. These stresses, which can be either tensile or compressive, are difficult to detect and eliminate because of their highly localized nature. We propose that their high-stored internal energy makes potential sites for defect nucleation sites under radiation, particularly if their locations coincide with the electrically sensitive regions of a transistor. In this study, we validate this hypothesis with molecular dynamic simulation and experiments exposing both pristine and annealed HEMTS to 2.8 MeV Au +3 irradiation. Our unique annealing process uses mechanical momentum of electrons, also known as the electron wind force (EWF) to mitigate the residual stress at room temperature. High-resolution transmission electron microscopy and cathodoluminescence spectra reveal the reduction of point defects and dislocations near the two-dimensional electron gas region of EWF-treated devices compared to pristine devices. The EWF-treated HEMTs showed relatively higher resilience with approximately 10% less degradation of drain saturation current and ON-resistance and 5% less degradation of peak transconductance. Both mobility and carrier concentration of the EWF-treated devices were less impacted compared to the pristine devices. Our results suggest that the lower density of nanoscale stress localization contributed to the improved radiation tolerance of the EWF-treated devices. Intriguingly, the EWF is found to modulate the defect distribution by moving the defects to electrically less sensitive regions in the form of dislocation networks, which act as sinks for the radiation induced defects and this assisted faster dynamic annealing.

AlGaN/GaN HEMTs↗

Role of Surface Termination in the Structural and Electronic Properties of Sc$_2$CT$_\textrm{x}$ MXene

Graphene-like layered transition metal carbides, nitrides, or carbonitrides, called MXenes, obey the stoichiometric formula of M n+1 X n T x , where M is an early transition metal such as scandium (Sc), n is a natural number, X is C, N, or CN, and T x is a functional group such as –O, –F, or –OH that passivates the surface of the MXene. The electronic structure of bare Sc 2 C and functionalized Sc 2 CT x MXenes are explored by performing first-principles density functional theory (DFT) calculations. The bare Sc 2 C is metallic, but less stable than its passivated structure. The Sc 2 C MXene has an interlayer 2D electron gas not bound to Sc or C atoms but free to move, making it an electride. DFT calculations show that functionalization can open an energy gap in Sc 2 CT x MXenes. The size and type (direct versus indirect) of the bandgap vary with the functional groups, which provides a means for opening and tuning of the band gap.

DFT↗

Fast spark-detection system for GEM detectors

The sPHENIX experiment is currently under commissioning at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL). The Time Projection Chamber (TPC) serves as a tracking detector for the experiment. The sPHENIX TPC uses a stack of four Gas Electron Multipliers (GEMs) as a gain stage in a reduced ion back-flow configuration. To mitigate the damaging effects of sparks in the GEMs, an online spark monitoring system was created. Once the system detects a spark in a GEM stack, the voltages across the GEMs in that stack can be lowered to prevent further sparking without affecting the gain and efficiency of the other modules. Spark signals are coupled out of the GEM stack by a pick-off capacitor attached to the bottom of the bottom GEM. Custom PCBs convert the oscillatory spark signal into a mono-polar pulse that is then digitized. The software then saves the waveform in a server and uses experimentally derived thresholds to determine how to react. As a result, the system has so far proven to be effective at improving the stability of the TPC and preventing damaging events while collecting cosmic ray data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Removing Basis Set Incompleteness Error in Finite-Temperature Electronic Structure Calculations: Two-Electron Systems

We investigate the basis-set-size dependence for quantities related to interacting electrons in the canonical ensemble. Calculations are performed using exact diagonalization (finite temperature full configuration interaction method) on two-electron model systems–the uniform electron gas (UEG) and the helium atom. Our data reproduce previous observations of a competition for how the internal energy converges between the ground-state correlation energy and the high-temperature kinetic energy. We explore how this can be related to component parts of the internal energy including kinetic, exchange, and correlation energies and show there is surprising nuance in how this can be broken down into mostly monotonically converging quantities. We also show that separation of the free energy into a free energy with/without correlation allows for monotonic convergence with basis set size due to the variational principle. We find that the free energy convergence matches the previously observed convergence properties of the internal energy. We discuss the free energy divergence that happens when converging a finite basis analytical hydrogen atom to the complete basis set limit and compare this to the energies of a helium atom in a large periodic box. Reducing the box size, we saw convergence trends for the helium atom that were similar to the UEG.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

Development of the CMS detector for the CERN LHC Run 3

Since the initial data taking of the CERN LHC, the CMSexperiment has undergone substantial upgrades and improvements. Thispaper discusses the CMS detector as it is configured for the thirddata-taking period of the CERN LHC, Run 3, which started in2022. The entire silicon pixel tracking detector was replaced. A newpowering system for the superconducting solenoid was installed. Theelectronics of the hadron calorimeter was upgraded. All the muonelectronic systems were upgraded, and new muon detector stationswere added, including a gas electron multiplier detector. Theprecision proton spectrometer was upgraded. The dedicated luminositydetectors and the beam loss monitor were refurbished. Substantialimprovements to the trigger, data acquisition, software, andcomputing systems were also implemented, including a new hybridCPU/GPU farm for the high-level trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗