Search NASA⌕ Search

SEARCH · Search NASA

Results for “END EFFECTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Dragonfly Entry and Descent System

Dragonfly is a proposed New Frontiers class mission that will send a nuclear powered octocopter to the surface of Titan for an extended science mission. This presentation will provide an overview of the Entry and Descent system that is under development to ensure the save delivery of this unique "relocatable lander" to Titan. Titan's dense atmosphere, large atmospheric scale height, and low gravity allows for a slow-paced entry and descent sequence that lasts more than 100 minutes, as opposed to the "7 minutes of terror" that is charac-teristic of landed Mars missions. This slow pace al-lows for sufficient temporal separation between critical events of the EDL sequence to minimize overall risk.The Dragonfly entry and descent system is composed of high-heritage components, minimizing overall risk. The aeroshell will be a scaled Genesis Sample Return capsule with a diameter of 3.75 meters, built by Lock-heed Martin. The thermal protection system (TPS) is made up of Phenolic Impregnated Carbon Ablator-Domestic (PICA-D) on the heatshield, SLA-561V on the backshell, and SLA-220M on the aft cover and low gain antenna. Each material has extensive heritage for the chosen application. The spacecraft will enter Titan at a velocity of 7.3 km/s, resulting in a predicted fully margined stagnation point heating environment of 254 W/cm2 heat rate and 13 kJ/cm2 heat load, well within the tested limits of the chosen materials. The aeroheat-ing environments, including the significant contribu-tion of shock layer radiation from CN on both the heatshield and backshell, are evaluated using state of the art models and codes that have been validated with appropriate ground testing.Once the deceleration pulse is complete, a disk-gap-band (DGB) drogue parachute will be deployed at ap-proximately Mach 1.5 to stabilize and further deceler-ate the spacecraft. Due to the dense atmosphere, the spacecraft will spend more than 80 minutes on this parachute, until reaching an appropriate altitude to de-ploy the subsonic main parachute. The lander is re-leased after approximately 17 minutes on the main chute before releasing and transitioning to powered flight in order to navigate to its first landing site. The release of the lander from the backshell effectively ends the entry and descent portion of the mission.The full presentation will provide additional details about the design of the EDL system hardware, engi-neering design, and overall con-ops. Preliminary aero-thermal and TPS sizing analyses will be presented, and the parachute system will be described in greater detail. In addition, the Dragonfly spacecraft will carry an En-gineering Science Investigation (ESI) package designed to obtain engineering data during EDL that will be used to validate the design methodology for future missions. An overview of the proposed ESI package will also be presented.

EDL↗

Flow regimes during immiscible displacement

Fractional ow of immiscible phases occurs at the pore scale where grain surfaces and phases interfaces obstruct phase mobility. However, the larger scale behavior is described by a saturation-dependent phenomenological relationship called relative permeability. As a consequence, pore-scale parameters, such as phase topology and/ or geometry, and details of the flow regime cannot be directly related to Darcy-scale flow parameters. It is well understood that relative permeability is not a unique relationship of wetting-phase saturation and rather depends on the experimental conditions at which it is measured. Herein we use fast X-ray microcomputed tomography to image pore-scale phase arrangements during fractional flow and then forward simulate the flow regimes using the lattice-Boltzmann method to better understand the underlying pore-scale flow regimes and their influence on Darcy-scale parameters. We find that relative permeability is highly dependent on capillary number and that the Corey model fits the observed trends. At the pore scale, while phase topologies are continuously changing on the scale of individual pores, the Euler characteristic of the nonwetting phase (NWP) averaged over a sufficiently large field of view can describe the bulk topological characteristics; the Euler characteristic decreases with increasing capillary number resulting in an increase in relative permeability. Lastly, we quantify the fraction of NWP that flows through disconnected ganglion dynamics and demonstrate that this can be a significant fraction of the NWP flux for intermediate wetting-phase saturation. Furthermore, rate dependencies occur in our homogenous sample (without capillary end effect) and the underlying cause is attributed to ganglion flow that can significantly influence phase topology during the fractional flow of immiscible phases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active-to-Passive Environmental Cleanup Transition Strategies - 13220

The Savannah River Site uses a graded approach to environmental cleanup. The selection of groundwater and vadose zone remediation technologies for a specific contamination area is based on the size, contaminant type, contaminant concentration, and configuration of the plume. These attributes are the result of the nature and mass of the source of contamination and the subsurface characteristics in the area of the plume. Many large plumes consist of several zones that are most efficiently addressed with separate complementary corrective action/remedial technologies. The highest concentrations of contaminants are found in the source zone. The most robust, high mass removal technologies are often best suited for remediation of the source zone. In the primary plume zone, active remedies, such as pump-and-treat, may be necessary to remove contaminants and exert hydraulic control of the plume. In the dilute fringe zone, contaminants are generally lower in concentration and can often be treated with passive techniques. A key determination in achieving an acceptable and cost-effective end state for a given waste unit is when to transition from an active treatment system to a more passive or natural approach (e.g., monitored natural attenuation or enhanced attenuation). This paper will discuss the considerations for such a transition as well as provide examples of successful transitions at the Savannah River Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Stagger on the Vibroacoustic Loads from Clustered Rockets

The effect of stagger startup on the vibro-acoustic loads that form during the end- effects-regime of clustered rockets is studied using both full-scale (hot-gas) and laboratory scale (cold gas) data. Both configurations comprise three nozzles with thrust optimized parabolic contours that undergo free shock separated flow and restricted shock separated flow as well as an end-effects regime prior to flowing full. Acoustic pressure waveforms recorded at the base of the nozzle clusters are analyzed using various statistical metrics as well as time-frequency analysis. The findings reveal a significant reduction in end- effects-regime loads when engine ignition is staggered. However, regardless of stagger, both the skewness and kurtosis of the acoustic pressure time derivative elevate to the same levels during the end-effects-regime event thereby demonstrating the intermittence and impulsiveness of the acoustic waveforms that form during engine startup.

Rojo, Raymundo↗

The Effect of Variable End of Charge Battery Management on Small-Cell Batteries

Batteries are critical components for spacecraft, supplying power to all electrical systems during solar eclipse. These components must be lightweight due to launch vehicle limitations and the desire to fly heavier, more capable payloads, and must show excellent capacity retention with age to support the ever growing durations of space missions. ABSL's heritage Lithium Ion cell, the ABSL 18650HC, is an excellent low mass solution to this problem that has been proven capable of supporting long mission durations. The NASA Glenn Research Center recently proposed and initiated a test to study the effects of reduced end of charge voltage on aging of the ABSL 18650HC and other Lithium Ion cells. This paper presents the testing details, a method to analyze and compare capacity fade between the different cases, and a preliminary analysis of the to-date performance of ABSL s cells. This initial analysis indicates that employing reduced end of charge techniques could double the life capabilities of the ABSL 18650HC cell. Accordingly, continued investigation is recommended, particularly at higher depths of discharge to better assess the method s potential mass savings for short duration missions.

Neubauer, Jeremy S.↗

Effects of End-Wall Vibration on Oscillatory Thermocapillary Flow

Our previous float zone experiments 1,2 with NaNO3 revealed that steady thermocapillary flow (TC flow) can be balanced/offset by the controlled surface streaming flow (CSS flow), induced by end-wall vibration. In the current experiments, we are examining the effects of surface streaming flow on steadying/stabilizing oscillatory thermocapillary flow. To this effect, we have set up a controlled NaNO3 half-zone experiment, where the processing parameters like zone dimensions and temperature gradients scan be easily varied to achieve oscillatory TC flow. In the present paper, we discuss the thermal signature of the TC flow, and how it is affected by imposition of CSS flow. The results will also include a comparison of the microstructure of a NaNO3- BaNO3 eutectic, processed under oscillatory TC conditions, with and without imposed CSS flow.

Bhowmick, J.↗

The Effect of Variable End of Charge Battery Management on Small-Cell Batteries

ABSL Space Products is the world leading supplier of Lithium-ion batteries for space applications and has pioneered the use of small capacity COTS cells within large arrays. This small-cell approach has provided many benefits to space application designers through increased flexibility and reliability over more traditional battery designs. The ABSL 18650HC cell has been used in most ABSL space battery applications to date and has a recommended End Of Charge Voltage (EOCV) of 4.2V per cell. For all space applications using the ABSL 18650HC so far, this EOCV has been used at all stages of battery life from ground checkout to in orbit operations. ABSL and NASA have identified that, by using a lower EOCV for the same equivalent Depth Of Discharge (DOD), battery capacity fade could be reduced. The intention of this paper is to compare battery performance for systems with fixed and variable EOCV. In particular, the effect of employing the blanket value of 4.2V per cell versus utilizing a lower EOCV at Beginning Of Life (BOL) before gradually increasing it (as the effects of capacity fade drive the End Of Discharge Voltage closer to the acceptable system level minimum) is analyzed. Data is compared from ABSL in-house and NASA GRC tests that have been run under fixed and variable EOCV conditions. Differences in capacity fade are discussed and projections are made as to potential life extension capability by utilizing a variable EOCV strategy.

Neubauer, Jeremy↗

End-to-End Models for Effects of System Noise on LIMS Analysis of Igneous Rocks

The ChemCam instrument on the Mars Science Laboratory will be the first extraterrestial deployment of laser-induced breakdown spectroscopy (UBS) for remote geochemical analysis. LIBS instruments are also being proposed for future NASA missions. In quantitative LIBS applications using multivariate analysis techniques, it is essential to understand the effects of key instrument parameters and their variability on the elemental predictions. Baseline experiments were run on a laboratory instrument in conditions reproducing ChemCam performance on Mars. These experiments employed Nd:YAG laser producing 17 mJ/pulse on target and an with a 200 {micro}m FWHM spot size on the surface of a sample. The emission is collected by a telescope, imaged on a fiber optic and then interfaced to a demultiplexer capable of >40% transmission into each spectrometer. We report here on an integrated end-to-end system performance model that simulates the effects of output signal degradation that might result from the input signal chain and the impact on multivariate model predictions. There are two approaches to modifying signal to noise (SNR): degrade the signal and/or increase the noise. Ishibashi used a much smaller data set to show that the addition of noise had significant impact while degradation of spectral resolution had much less impact on accuracy and precision. Here, we specifically focus on aspects of remote LIBS instrument performance as they relate to various types of signal degradation. To assess the sensitivity of LIBS analysis to signal-to-noise ratio (SNR) and spectral resolution, the signal in each spectrum from a suite of 50 laboratory spectra of igneous rocks was variably degraded by increasing the peak widths (simulating misalignment) and decreasing the spectral amplitude (simulating decreases in SNR).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytic investigation of effect of end-wall contouring on stator performance

Calculations show improved stator performance when the tip end wall was contoured so that the inlet area was greater than the exit area. Comparisons are made with previously published experimental data. The results of a parametric analysis of the effect contour geometry on the efficiency of a highly loaded axial stator are given. The maximum stator efficiency gain is about 0.8 percentage point, and this represents a 22 percent reduction in stator losses. The degree to which endwall contouring reduces the forces driving secondary flows was also examined. The driving forces for both cross channel and radial secondary flow were reduced.

Boyle, R. J.↗

The effect of riser end geometry on gas-solid hydrodynamics in a CFB riser operating in the core annular and dilute homogeneous flow regimes

Riser hydrodynamics are a function of the flow rates of gas and solids as well as the exit geometry, particularly when operated above the upper transport velocity. This work compares the exit voidage for multiple geometries and two different solids: Geldart group A glass beads and Geldart group B coke. Geometries were changed by modifying the volume of an abrupt T-shaped exit above the lateral riser exit. This was accomplished by positioning a plunger at various heights above the exit from zero to 0.38 m. A dimensionless expression used to predict smooth exit voidage was modified to account for the effect of the depth of the blind-T. The new correlation contains the solids-gas load ratio, solids-to-gas density ratio, bed-to-particle diameter ratio, gas Reynolds Number, as well as a term for the exit geometry. This study also found that there was a minimum riser roof height above the blind-T exit beyond which the riser exit voidage was not affected by the exit geometry. A correlation for this minimum riser roof height has also been developed in this study. This study covered riser superficial gas velocities of 4.35 to 7.7 m/s and solids circulation rates of 1.3 to 11.5 kg/s.

01 COAL, LIGNITE, AND PEAT↗

Effect of insulator end cap thickness on time-dependent Hartmann flow in a rotating mirror

We present a framework for analysing plasma flow in a rotating mirror. By making a series of physical assumptions, we reduce the magnetohydrodynamic (MHD) equations in a three-dimensional cylindrical system to a one-dimensional system in a shallow, cuboidal channel within a transverse magnetic field, similar to the Hartmann flow in ducts. We then solve the system both numerically and analytically for a range of values of the Hartmann number and calculate the dependence of the plasma flow speed on the thickness of the insulating end cap. We observe that the mean flow overshoots and decelerates before achieving a steady-state value, a phenomenon that the analytical model cannot capture. This overshoot is directly proportional to the thickness of the insulating end cap and the external electric field, with a weak dependence on the external magnetic field. Our simplified model can act as a benchmark for future simulations of the supersonic mirror device CMFX (centrifugal magnetic fusion experiment), which will employ more sophisticated physics and realistic magnetic field geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of end-ring stiffness on buckling of pressure-loaded stiffened conical shells

Buckling studies were conducted on truncated 120 deg conical shells having large end rings and many interior reinforcing rings that are typical of aeroshells used as spacecraft decelerators. Changes in base-end-ring stiffness were accomplished by simply machining away a portion of the base ring between successive buckling tests. Initial imperfection measurements from the test cones were included in the analytical model.

Davis, R. C.↗

Volumetric-Modulated Arc Therapy: Effective and Efficient End-to-End Patient-Specific Quality Assurance

Purpose: To explore an effective and efficient end-to-end patient-specific quality-assurance (QA) protocol for volumetric modulated arc radiotherapy (VMAT) and to evaluate the suitability of a stationary radiotherapy QA device (two-dimensional [2D] ion chamber array) for VMAT QA. Methods and Materials: Three methods were used to analyze 39 VMAT treatment plans for brain, spine, and prostate: ion chamber (one-dimensional absolute, n = 39), film (2D relative, coronal/sagittal, n = 8), and 2D ion chamber array (ICA, 2D absolute, coronal/sagittal, n = 39) measurements. All measurements were compared with the treatment planning system dose calculation either via gamma analysis (3%, 3- to 4-mm distance-to-agreement criteria) or absolute point dose comparison. The film and ion chamber results were similarly compared with the ICA measurements. Results: Absolute point dose measurements agreed well with treatment planning system computed doses (ion chamber: median deviation, 1.2%, range, -0.6% to 3.3%; ICA: median deviation, 0.6%, range, -1.8% to 2.9%). The relative 2D dose measurements also showed good agreement with computed doses (>93% of pixels in all films passing gamma, >90% of pixels in all ICA measurements passing gamma). The ICA relative dose results were highly similar to those of film (>90% of pixels passing gamma). The coronal and sagittal ICA measurements were statistically indistinguishable by the paired t test with a hypothesized mean difference of 0.1%. The ion chamber and ICA absolute dose measurements showed a similar trend but had disparities of 2-3% in 18% of plans. Conclusions: After validating the new VMAT implementation with ion chamber, film, and ICA, we were able to maintain an effective yet efficient patient-specific VMAT QA protocol by reducing from five (ion chamber, film, and ICA) to two measurements (ion chamber and single ICA) per plan. The ICA (Matrixx Registered-Sign , IBA Dosimetry) was validated for VMAT QA, but ion chamber measurements are recommended for absolute dose comparison until future developments correct the ICA angular dependence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End region and current consolidation effects upon the performance of an MHD channel for the ETF conceptual design

It is noted that operating conditions which yielded a peak thermodynamic efficiency (41%) for an EFT-size MHD/steam power plant were previously (Wang et al., 1981; Staiger, 1981) identified by considering only the active region (the primary portion for power production) of an MHD channel. These previous efforts are extended here to include an investigation of the effects of the channel end regions on overall power generation. Considering these effects, the peak plant thermodynamic efficiency is found to be slightly lowered (40.7%); the channel operating point for peak efficiency is shifted to the supersonic mode (Mach number of approximately 1.1) rather than the previous subsonic operation (Mach number of approximately 0.9). Also discussed is the sensitivity of the channel performance to the B-field, diffuser recovery coefficient, channel load parameter, Mach number, and combustor pressure.

Wang, S. Y.↗

Contaminant Migration Modeling to Support the In Situ Decommissioning of Hardened Nuclear Facilities - 20215

The decommissioning of hardened nuclear facilities provides a unique challenge in balancing current worker dose with exposure to future receptors and media. In situ decommissioning (ISD) is a cost-effective and safe option for the closure of such facilities but requires a detailed understanding of the threat that radioactive and hazardous constituents remaining in the facilities pose to groundwater and surrounding surface water. The Savannah River Site (SRS) extensively employs contaminant migration models within the decommissioning process to develop site-specific removal, grouting, and monitoring strategies in support of safe and effective final end states of nuclear facilities. This work discusses the use of contaminant migration modeling in the ISD process at SRS, including specific examples from the closure of P-Reactor and R-Reactor, Building 235-F, F-Canyon and F/H Laboratory Complex. Migration models developed during the closure of P-Reactor and R-Reactor were divided into four source areas: the reactor vessel, the process area, the disassembly basin, and the purification wing. Each source area was assigned a specific inventory and migration pathway and was then subject to varying hypothetical removal, capping, and grouting schemes. Modeling indicated that groundwater Maximum Concentration Limits (MCLs) might be exceeded if no action was taken for eleven and ten constituents of concern (COCs) at P-Reactor and R-Reactor, respectively. These exceedances could occur in as few as 200 to 500 years. Alternatively, the migration modeling demonstrated that the selected ISD actions reduced contaminant mobility which allowed for significant radioactive decay and resulted in fewer predicted exceedances of groundwater MCLs (five COCs for P-Reactor; eight COCs for R-Reactor). In response to the modeling results for P-Reactor and R-Reactor, effectiveness monitoring programs were developed to target contaminants, specific to each reactor, that may migrate to groundwater. Contaminant migration modeling also revealed that roof collapse was a large factor in the release of COCs to the environment, giving rise to roof improvements, and an inspection and vegetation control program to ensure roof stability over time. Contaminant migration modeling is also aiding in the closure planning for hardened facilities in F Area. Building 235-F housed the Actinide Billet Line, which produced Np-237 billets for irradiation in SRS reactors, and the Plutonium Fuel Form (PuFF) facility that produced Pu-238 heat sources for the space program. As a result of these missions, areas within Building 235-F contain considerable residual amounts of both Pu-238 and Np-237. Contaminant migration modeling of Building 235-F was originally performed in 2012 to identify the feasibility of ISD and the amount of radioactive material removal required to prevent the exceedance of groundwater MCLs. The original model indicated that a 60% reduction in the PuFF facility Pu-238 inventory could keep groundwater concentrations below standards, while Np-237 did not pose a threat to groundwater. However, updates to the model with an emphasis on source impact pathways revealed that, due to the orientation of the source areas relative to groundwater flow, no amount of reasonable removal of Pu-238 would keep groundwater concentrations below MCLs and that Np-237 could be a large contributor to localized MCL exceedances. With this insight, the refined 2019 model is being used to assist in the development of grouting plans specific to each facility source area, where bentonite may be utilized to slow the migration of Pu-238 and its daughter products from the PuFF facility and a reducing grout may decrease Np-237 transport by ensuring the nuclide remains in the less mobile +IV oxidation state. The beginning phases of contaminant migration modeling are underway for F-Canyon and associated facilities using lessons learned from the Reactors and Building 235-F. A contaminant migration pathway, similar to the pathway used for the reactor vessels, is being developed for the hot and warm canyons. The F-Canyon inventories are being spatially refined to identify specific and localized source zones, comparable to Building 235-F, that may impact groundwater. Contaminant migration modeling provides vital input within the ISD process, from facility investigation to post closure effectiveness monitoring, making it a valuable tool in the development of safe and effective end states for hardened nuclear facilities at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗