Search NASA⌕ Search

SEARCH · Search NASA

Results for “ERROR CORRECTING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Superconducting switch concept applied to superconducting undulator phase-error correction

Superconducting undulator (SCU) technology has the potential to significantly enhance the performance of synchrotron radiation sources for storage ring and FEL applications. Since 2002, our team at Lawrence Berkeley National Laboratory has been performing R and D on superconducting undulators, including the fabrication of three Nb{sub 3}Sn prototypes. We have demonstrated experimentally the possibility to provide the prototype with trim coils that could be used for phase error correction. The research effort that we report here demonstrates the possibility to add degrees of freedom to the field correction provided by these coils in a cryogenic environment. By means of bridge of superconducting switches, we can modify the current direction through a trim coil. Here we describe the design of the experimental bridge we fabricated, the results we obtained and finally the generalized concept one could plan to apply to correct the phase errors with trim coils connected to a network of superconducting bridges.

43 PARTICLE ACCELERATORS↗

A Comparison Between Electronic Portal Imaging Device and Cone Beam CT in Radiotherapy Verification of Nasopharyngeal Carcinoma

The demand of greater accuracy in intensity-modulated radiotherapy (IMRT) has driven the development of more advanced verification systems. The purpose of this study is to investigate the differences in verification accuracy in terms of the position error detected between cone-beam computed tomography (CBCT) and electronic portal imaging device (EPID) in the IMRT of nasopharyngeal carcinoma (NPC). Two groups of NPC patients (n = 22 and n = 28) verified by CBCT (G1-CB), EPID (G1-EP), and EPID (G2-EP) only, respectively, were recruited. The positional errors between the G1-CB group and the G2-EP group were compared. In addition, the magnitudes of the position errors of EPID taken in the same session of the CBCT, but after necessary corrections (G1-EP), were analyzed. In the CBCT group, 455 CBCT images (G1-CB) and 206 EPID images (G1-EP) were collected, whereas 319 EPID images (G2-EP) for the EPID group, were recorded. The median position errors detected in CBCT were between 0.80 and 0.90 mm in the antero-posterior (A-P), left-right (L-R), and supero-inferior (S-I) directions, whereas those of the EPID were all 0.50 mm. The magnitude of position deviation detected by the CBCT was higher than that of the EPID and their differences were extremely significant (p < 0.001). The frequencies in the G2-EP group with position errors greater than the tolerance (2 mm) were 32, 42, and 27 in the A-P, L-R, and S-I directions, respectively, which accounted for 16.5%, 21.6%, and 13.9% of the total number of EPID. There was difference in verification capability between the CBCT and EPID when applied to IMRT of NPC patients. Because an average of 1 of 6 verifications in EPID was inferior to that of the CBCT, verification by CBCT is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superconducting microwave cavities and qubits for quantum information systems

Superconducting microwave cavities featuring ultrahigh Q-factors, which measure the efficiency of energy storage in relation to energy loss in a system, are revolutionizing quantum computing by providing long coherence times exceeding 1 ms, crucial for the development of scalable multi-qubit quantum systems with low error rates. Here, in this work, we provide an in-depth analysis of recent advances in ultrahigh Q-factor cavities, integration of Josephson junction-based qubits, and bosonic-encoded qubits in 3D cavities. We examine the sources of quantum state dephasing caused by damping and noise mechanisms in cavities and qubits, highlighting the critical challenges that need to be addressed to achieve even higher coherence times. We critically survey the latest progress made in implementing single 3D qubits using superconducting materials, normal metals, and multi-qubit and multi-state quantum systems. Our work sheds light on the promising future of this research area, including novel materials for cavities and qubits, modes with nontrivial topological properties, error correction techniques for bosonic qubits, and new light–matter interaction effects.

3D printing↗

A new method for tracking organ motion on diagnostic ultrasound images

Purpose: Respiratory-gated irradiation is effective in reducing the margins of a target in the case of abdominal organs, such as the liver, that change their position as a result of respiratory motion. However, existing technologies are incapable of directly measuring organ motion in real-time during radiation beam delivery. Hence, the authors proposed a novel quantitative organ motion tracking method involving the use of diagnostic ultrasound images; it is noninvasive and does not entail radiation exposure. In the present study, the authors have prospectively evaluated this proposed method. Methods: The method involved real-time processing of clinical ultrasound imaging data rather than organ monitoring; it comprised a three-dimensional ultrasound device, a respiratory sensing system, and two PCs for data storage and analysis. The study was designed to evaluate the effectiveness of the proposed method by tracking the gallbladder in one subject and a liver vein in another subject. To track a moving target organ, the method involved the control of a region of interest (ROI) that delineated the target. A tracking algorithm was used to control the ROI, and a large number of feature points and an error correction algorithm were used to achieve long-term tracking of the target. Tracking accuracy was assessed in terms of how well the ROI matched the center of the target. Results: The effectiveness of using a large number of feature points and the error correction algorithm in the proposed method was verified by comparing it with two simple tracking methods. The ROI could capture the center of the target for about 5 min in a cross-sectional image with changing position. Indeed, using the proposed method, it was possible to accurately track a target with a center deviation of 1.54 ± 0.9 mm. The computing time for one frame image using our proposed method was 8 ms. It is expected that it would be possible to track any soft-tissue organ or tumor with large deformations and changing cross-sectional position using this method. Conclusions: The proposed method achieved real-time processing and continuous tracking of the target organ for about 5 min. It is expected that our method will enable more accurate radiation treatment than is the case using indirect observational methods, such as the respiratory sensor method, because of direct visualization of the tumor. Results show that this tracking system facilitates safe treatment in clinical practice.

60 APPLIED LIFE SCIENCES↗

Unified architecture for quantum lookup tables

Quantum access to arbitrary classical data encoded in unitary black-box oracles underlies interesting data-intensive quantum algorithms, such as machine learning or electronic structure simulation. The feasibility of these applications depends crucially on gate-efficient implementations of these oracles, which are commonly some reversible versions of the Boolean circuit for a classical lookup table. Here, we present a general parametrized architecture for quantum circuits implementing a lookup table that encompasses all prior work in realizing a continuum of optimal trade-offs between qubits, non-Clifford gates, and error resilience, up to logarithmic factors. Our architecture assumes only local 2D connectivity, yet recovers results, with the appropriate parameters, polylogarithmic error scaling. We also identify regimes, such as simultaneous sublinear scaling, in all parameters. These results enable tailoring implementations of the commonly used lookup table primitive to any given quantum device with constrained resources.

quantum circuits↗

Adaptive Image-Guided Radiotherapy (IGRT) Eliminates the Risk of Biochemical Failure Caused by the Bias of Rectal Distension in Prostate Cancer Treatment Planning: Clinical Evidence

Purpose: Rectal distension has been shown to decrease the probability of biochemical control. Adaptive image-guided radiotherapy (IGRT) corrects for target position and volume variations, reducing the risk of biochemical failure while yielding acceptable rates of gastrointestinal (GI)/genitourinary (GU) toxicities. Methods and Materials: Between 1998 and 2006, 962 patients were treated with computed tomography (CT)-based offline adaptive IGRT. Patients were stratified into low (n = 400) vs. intermediate/high (n = 562) National Comprehensive Cancer Network (NCCN) risk groups. Target motion was assessed with daily CT during the first week. Electronic portal imaging device (EPID) was used to measure daily setup error. Patient-specific confidence-limited planning target volumes (cl-PTV) were then constructed, reducing the standard PTV and compensating for geometric variation of the target and setup errors. Rectal volume (RV), cross-sectional area (CSA), and rectal volume from the seminal vesicles to the inferior prostate (SVP) were assessed on the planning CT. The impact of these volumetric parameters on 5-year biochemical control (BC) and chronic Grades {>=}2 and 3 GU and GI toxicity were examined. Results: Median follow-up was 5.5 years. Median minimum dose covering cl-PTV was 75.6 Gy. Median values for RV, CSA, and SVP were 82.8 cm{sup 3}, 5.6 cm{sup 2}, and 53.3 cm{sup 3}, respectively. The 5-year BC was 89% for the entire group: 96% for low risk and 83% for intermediate/high risk (p < 0.001). No statistically significant differences in BC were seen with stratification by RV, CSA, and SVP in quartiles. Maximum chronic Grades {>=}2 and 3 GI toxicities were 21.2% and 2.9%, respectively. Respective values for GU toxicities were 15.5% and 4.3%. No differences in GI or GU toxicities were noted when patients were stratified by RV. Conclusions: Incorporation of adaptive IGRT reduces the risk of geometric miss and results in excellent biochemical control that is independent of rectal volume/distension while maintaining very low rates of chronic GI toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-181: Clinical Implementation of Task Group 176

Purpose: The implementation of TG-176 with regards to immobilization devices and couch tops as they effect dosimetric treatment planning. Methods: The external devices used clinically were scanned to measure their HU values. Plans were created in the Eclipse treatment planning system (TPS) using these devices, one that accounted for the correct HU value of the each device and another that did not include the device as a structure. A dose subtraction was performed between the two plans to evaluate the dosimetric differences. The metrics used for evaluation included attenuation and surface dose. Plan parameters were varied to evaluate the impact of the devices in different clinical scenarios. Results: While the exact HU values of our results are clinic-dependent, the protocol being implemented is widely applicable. We recommend a four step process for implementing this task group. First, physics should scan each treatment device to determine accurate HU values. Second, CT therapists should include in the setup note which table top was used during patient CT simulation and are asked to make immobilization devices as uniform in thickness as possible. Therapists should also index the devices whenever possible so beam will traverse the same area of the device. Third, the dosimetrist should manually correct the HU value for any external device, including the couch. For H&N cases, the rails must be removed from the couch structure. When rails are used during treatments, it is important to make note of their exact position in the setup notes. Finally, physicians should be made aware that there could be changes in surface doses depending on whether or not immobilization devices or couch tops are in the beam path. Conclusion: The protocol outlined above was implemented to reduce the errors that arise from ignoring effects of external devices, thus ensuring safer, more accurate patient treatments.

60 APPLIED LIFE SCIENCES↗

Improving Swift-XRT positions of GRBs

Since GRBs fade rapidly, it is important to publish accurate, precise positions at early times. For Swift-detected bursts, the best promptly available position is most commonly the X-ray Telescope (XRT) position. We present two processes, developed by the Swift team at Leicester, which are now routinely used to improve the precision and accuracy of the XRT positions reported by the Swift team. Both methods, which are fully automated, make use of a PSF-fitting approach which accounts for the bad columns on the CCD. The first method yields positions with 90% error radii <4.4''90% of the time, within 10-20 minutes of the trigger. The second method astrometrically corrects the position using UVOT field stars and the known mapping between the XRT and UVOT detectors, yielding enhanced positions with 90% error radii of <2.8''90% of the time, usually 2 hours after the trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-BRB-06: Dosimetric Impact of Breast Contour Reconstruction Errors in GammaPod Stereotactic Radiotherapy

Purpose: The first GammaPod™ unit, a dedicated prone stereotactic treatment device for early stage breast cancer, has been installed and commissioned at University of Maryland School of Medicine. The objective of this study was to investigate potential dosimetric impact of inaccurate breast contour. Methods: In GammaPod treatments, patient’s beast is immobilized by a breast cup device (BCID) throughout the entire same-day imaging and treatment procedure. 28 different BICD sizes are available to accommodate patients with varying breast sizes. A mild suction helps breast tissue to conform to the shape of the cup with selected size. In treatment planning, dose calculation utilizes previously calculated dose distributions for available cup geometry rather than the breast shape from CT image. Patient CT images with breast cups indicate minor geometric discrepancy between the matched shape of the cup and the breast contour, i.e., the contour size is larger or smaller. In order to investigate the dosimetric impact of these discrepancies, we simulated such discrepancies and reassessed the dose to target as well as skin. Results: In vicinity of skin, hot/cold spots were found when matched cup size was smaller/larger than patient’s breast after comparing the corrected dose profiles from Monte Carlo simulation with the planned dose from TPS. The overdosing/underdosing of target could yield point dose differences as large as 5% due to these setup errors (D95 changes within 2.5%). Maximal skin dose was overestimated/underestimated up to 25%/45% when matched cup size was larger/smaller than real breast contour. Conclusion: The dosimetric evaluation suggests substantial underdosing/overdosing with inaccurate cup geometry during planning, which is acceptable for current clinical trial. Further studies are needed to evaluate such impact to treating small volume close to skin.

60 APPLIED LIFE SCIENCES↗

Mitigation of the Brighter-Fatter Effect in the LSST Camera

Thick, fully depleted charge-coupled devices (CCDs) are known to exhibit non-linear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). This particularly impacts bright calibration stars, which appear larger than their intrinsic shape, creating a flux-dependent point-spread function (PSF) that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSST Camera before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new sampling method based on a physically motivated model to account these higher-order terms in the correction, and then we test the modified correction on both datasets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars which we conclude is the result of a unmodeled curl component of the deflection field by the correction. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Photometric Recalibration of the SDSS Stripe 82 to a Few Millimagnitude Precision with the Stellar Color Regression Method and Gaia EDR3

By combining spectroscopic data from the LAMOST DR7, Sloan Digital Sky Survey (SDSS) DR12, and corrected photometric data from the Gaia EDR3, we apply the stellar color regression (SCR) method to recalibrate the SDSS Stripe 82 standard stars catalog of Ivezic' et al. With a total number of about 30,000 spectroscopically targeted stars, we have mapped out the relatively large and strongly correlated photometric zero-point errors present in the catalog, ~2.5% in the u band and ~1% in the griz bands. Our study also confirms some small but significant magnitude dependence errors in the z band for some charge-coupled devices. Various tests show that we have achieved an internal precision of about 5 mmag in the u band and about 2 mmag in the griz bands, which is about five times better than previous results. We also apply the method to the latest version of the catalog (v4.2), and find modest systematic calibration errors of up to ~1% along the R.A. direction and smaller errors along the decl. direction. The results demonstrate the power of the SCR method when combining spectroscopic data and Gaia photometry in breaking the 1% precision barrier of ground-based photometric surveys. Our work paves the way for the recalibration of the whole SDSS photometric survey and has important implications for the calibration of future surveys. Future implementations and improvements of the SCR method under different situations are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packet size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.

43 PARTICLE ACCELERATORS↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Internal structure of 0.9 GHz microplasma

Argon microplasmas generated at 0.9 GHz by a split-ring resonator form a single filament-shaped nonequilibrium glow discharge. The internal structure of these microplasmas is probed using laser diode absorption and imaging emission spectrometry. These two-dimensional diagnostics are then Abel inverted to reveal that the core of the filament has a strongly depleted central metastable argon population. The microdischarges are approximately 0.2 mm in width at 1 atm and expand with increasing input power between 0.05-1.5 W. The relative electron density and the Ar(4p) density are estimated from the emission detected by a CCD camera through various bandpass filters. Absolute Ar(4s) densities, on the other hand, are determined by Ar 801.4 nm absorption. The Ar(4s) profile transitions from center-peaked at low power (0.05 W) to center-depleted above 0.25 W, saturating at 10{sup 19} m{sup -3}. The electron density profile within the microplasma, however, remains center-peaked regardless of the power. The spatially-resolved gas temperature was estimated from the broadening of the Ar 801.4 nm absorption profile. The error in this gas temperature measurement due to the depletion of the metastable atoms is corrected using numerical heat transfer models and shown to be 1650 K if the plasma power is 1.2 W. Differences between the peak and average temperatures based on the nitrogen rotational spectrum are also explained using nitrogen emission imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, characterization and indoor validation of the optical soiling detector “DUSST”

Nowadays, photovoltaic (PV) technology has reached a high level of maturity in terms of module efficiency and cost competitiveness in comparison with other energy technologies. As PV has achieved high levels of deployment, the development of devices that can help to reduce PV operation and maintenance costs has become a priority. Soiling can be cause of significant losses in certain PV plants and its detection has become essential to ensure a correct mitigation. For this reason, accurate and low-cost monitoring devices are needed. While soiling stations have been traditionally employed to measure the impact of soiling, their high cost and maintenance have led to the development of innovative low-cost optical sensors, such as the device presented in this work and named “DUSST” (Detector Unit for Soiling Spectral Transmittance). The thermal characterization of DUSST’s components and the methodology used to predict soiling transmittance losses are presented in this study. The results demonstrate that the losses can be predicted with an error lower than 1.4%. The method has been verified with an experimental campaign with naturally soiled coupons exposed outdoors in Jaén, Spain.

14 SOLAR ENERGY↗

Invited Article: Deep Impact instrument calibration

Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [{approx}1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of {approx}9 pixels. The charge coupled device (CCD) read noise is {approx}1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to {approx}1%. Spectrometer read noise is {approx}2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to {approx}10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of {approx}2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to {approx}0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rolex: Resilience-oriented language extensions for extreme-scale systems

Future exascale high-performance computing (HPC) systems will be constructed from VLSI devices that will be less reliable than those used today, and faults will become the norm, not the exception. This will pose significant problems for system designers and programmers, who for half-a-century have enjoyed an execution model that assumed correct behavior by the underlying computing system. The mean time to failure (MTTF) of the system scales inversely to the number of components in the system and therefore faults and resultant system level failures will increase, as systems scale in terms of the number of processor cores and memory modules used. However every error detected need not cause catastrophic failure. Many HPC applications are inherently fault resilient. Yet it is the application programmers who have this knowledge but lack mechanisms to convey it to the system. In this paper, we present new Resilience Oriented Language Extensions (Rolex) which facilitate the incorporation of fault resilience as an intrinsic property of the application code. We describe the syntax and semantics of the language extensions as well as the implementation of the supporting compiler infrastructure and runtime system. Furthermore, our experiments show that an approach that leverages the programmer's insight to reason about the context and significance of faults to the application outcome significantly improves the probability that an application runs to a successful conclusion.

97 MATHEMATICS AND COMPUTING↗

Breast Patient Setup Error Assessment: Comparison of Electronic Portal Image Devices and Cone-Beam Computed Tomography Matching Results

Purpose: To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. Methods and Materials: Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the treatment beams were recorded. Registrations of the bony anatomy for CBCT to planning CT and EPID to digitally reconstructed-radiographs (DRRs) were compared. In addition, similar measurements of an anthropomorphic thorax phantom were acquired. Bland-Altman and linear regression analysis were performed for clinical and phantom registrations. Systematic and random setup errors were quantified for CBCT and EPID-driven correction protocols in the EPID coordinate system (U, V), with V parallel to the cranial-caudal axis and U perpendicular to V and the central beam axis. Results: Bland-Altman analysis of clinical EPID and CBCT registrations yielded 4 to 6-mm limits of agreement, indicating that both methods were not compatible. The EPID-based setup errors were smaller than the CBCT-based setup errors. Phantom measurements showed that CBCT accurately measures setup error whereas EPID underestimates setup errors in the cranial-caudal direction. In the clinical measurements, the residual bony anatomy setup errors after offline CBCT-based corrections were {Sigma}{sub U} = 1.4 mm, {Sigma}{sub V} = 1.7 mm, and {sigma}{sub U} = 2.6 mm, {sigma}{sub V} = 3.1 mm. Residual setup errors of EPID driven corrections corrected for underestimation were estimated at {Sigma}{sub U} = 2.2mm, {Sigma}{sub V} = 3.3 mm, and {sigma}{sub U} = 2.9 mm, {sigma}{sub V} = 2.9 mm. Conclusion: EPID registration underestimated the actual bony anatomy setup error in breast cancer patients by 20% to 50%. Using CBCT decreased setup uncertainties significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗