Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Pulse Detonation Engine for Advanced Oxy-Combustion of Coal-Based Fuel for Direct Power Extraction Applications

Pressure gain combustion and magnetohydrodynamic (MHD) systems have the potential to provide a step increase in the efficiency of combined-cycle power plants. Specific advantages include a net pressure increase to the system instead of a pressure drop, the high temperature of the detonation waves can increase the efficiency of power extraction compared to other processes, significant thermal energy can be released in a compact region, and the high velocities of the flow increase extraction of electrical power. In summary, a pressure gain combustor coupled with a MHD has the potential to be transformative. Despite the potential advantages, relatively little research has been conducted considering coupled pressure gain combustion systems with MHD systems. With this background and motivation, the overall goal of this effort was to advance the knowledge, technology, and computational tools associated with coupled detonation and MHD systems. A joint experimental and computational approach was used while seeking to accomplish the goals of this work. Specifically, two pulse detonation engines were developed and used for the experiments to produce detonations. Detonation speeds were measured for a variety of flow and fuel conditions (e.g., methane, propane, with coal particles). Preliminary electrical conductivity measurements were collected. An extensive amount of research was performed to identify sensitivities of detonation behaviors to the presence of combustion products. Computationally, a twofold approach was used in this work. First, a solver was developed for solving the governing equations for a reactive flow with coupled detonation and ionization chemistry. The solver was applied to study the impacts of seed material ionization on detonation. Second, a conservation element-solution element (CE-SE) based numerical solver for detonation studies with a reduced reaction mechanism for oxy-methane combustion was developed and verified on standard test cases. Key findings and contributions from this work are as follows. A system was developed for injecting powderized coal, or other seeding material, into a pulse-detonation system. The influence of a combustion product (i.e., CO 2 ) on detonation behavior was identified. Knowledge gained from this work is applicable to devices such as rotating detonation engines, where combustion products mix with fresh reactants. A system for measuring the electrical conductivity of the exhaust from a pulse-detonation engine was developed. The open-source solver, Clawpack, was extended to solve the reactive Euler equations for simulating detonations. A coupled combustion and ionization chemistry was developed in a single chemical kinetic model for methane oxidation. This model can be used to solve coupled MHD and detonation simulations. It was found that parasitic interactions from ionization chemistry with the magnetic field can reduce the detonation velocity by up to 8%, with a potential impact on power extraction of 15%. It is recommended that interactions between the detonation front and MHD field be considered. Higher gas temperatures and velocities were achieved owing to oxy-fuel detonations. Use of radical dissociation reactions in the reduced reaction mechanism, was found to be critical in predicting detonation temperature and velocity accurately.

01 COAL, LIGNITE, AND PEAT↗

Engine system and method including first and second turbochargers

An engine system includes an internal combustion engine having an intake passage, a first set of combustion chambers, a second set of combustion chambers, a first exhaust passage fluidly connected to the first set of combustion chambers, and a second exhaust passage fluidly connected to the second set of combustion chambers. The engine system includes a first turbocharger including a first compressor and a first turbine. The engine system also includes a second turbocharger including a second compressor and a second turbine, the second compressor connected in series with the first compressor, and the second turbine being in fluid communication with the second exhaust passage. The first and second turbines are connected in parallel such that the first turbine only receives exhaust flow from the first set of combustion chambers, and the second turbine only receives exhaust flow from the second set of combustion chambers.

Lusardi, Christopher↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simultaneous H/D/T and 3He/4He absolute concentration measurements with an optical Penning gauge on JET

The Optical Penning (or Species-Selective Penning) Gauge technique is used for the measurement of the H2/D2/T2 fuel isotopic composition and He/D2 concentration in the neutralized particle exhaust of fusion devices. An Optical Penning detection system has already been used in JET during its first deuterium-tritium campaigns (DTE1) and has been chosen by ITER. Recent improvements to the sub-divertor diagnostic suite as well as the optical instrumentation, in preparation for the next DT campaign, have improved the optical throughput of the measurement and enabled 3He/D2 detection down to 0.1 %. For the first time, the 3He/4He isotopic ratio can be measured simultaneously with the H/D/T ratio. This technique is of particular interest for ion cyclotron resonance frequency (ICRF) heating scenarios.

Vartanian, S.↗

Identification and control of the exhaust using gas perturbations in the DIII-D tokamak

This paper presents perturbative experiments that enable the validation and development of control-oriented models for exhaust control. We identify the response of the divertor plasma and scrape-off layer in the DIII-D tokamak to deuterium and nitrogen multi-sine perturbations, in favorable and unfavorable field directions for H-mode access. We obtained good signal-to-noise ratios in the 1–10 Hz frequency range by measuring Balmer-alpha, Lyman-alpha, and N 4+ line emission, radiated power, and neutral pressure. We find a similar phase response across gas species and magnetic field directions, while the gain response is nonlinear. With these experiments, we identify a control-oriented model to design a divertor radiated power controller to track specified reference waveforms in conjunction with resonant magnetic perturbations. Although the physics basis for compatibility between detachment and resonant magnetic perturbation edge-localized mode suppression remains to be demonstrated, the present results provide a robust controller that represents a promising step toward future joint control strategies.

detachment control↗

Machine learning mathematical models for incidence estimation during pandemics

Accurate estimates of the incidence of infectious diseases are key for the control of epidemics. However, healthcare systems are often unable to test the population exhaustively, especially when asymptomatic and paucisymptomatic cases are widespread; this leads to significant and systematic under-reporting of the real incidence. Here, we propose a machine learning approach to estimate the incidence of a pandemic in real-time, using reported cases and the overall test rate. In particular, we use Bayesian symbolic regression to automatically learn the closed-form mathematical models that most parsimoniously describe incidence. We develop and validate our models using COVID-19 incidence values for nine different countries, confirming their ability to accurately predict daily incidence. Remarkably, despite the differences in epidemic trajectories and dynamics across countries, we find that a single model for all countries offers a more parsimonious description and is more predictive of actual incidence compared to separate models for each country. Our results show the potential to accurately model incidence in real-time using closed-form mathematical models, providing a valuable tool for public health decision-makers.

Fajardo-Fontiveros, Oscar (ORCID:0000000207058972)↗

Oneida Indian Nation Facility Energy Efficiency Project (Final Technical Report)

The Oneida Indian Nation (“Oneida”) implemented a comprehensive energy efficiency project across nearly 30 facilities over the course of the project period. Grounded in findings from a 2018 energy audit, the project installed LED lighting, high-efficiency HVAC systems, programmable thermostats, variable speed drives, and kitchen exhaust controls across 28 Nation facilities and the Turning Stone Resort and Casino (TSRC) campus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Turbocharger system with turbine bypass circuit to reduce emissions during engine cold start

An engine system includes an engine having first and second exhaust manifolds each having outlet ports and a bypass runner. A first turbocharger is in fluid communication with the outlet port of the first manifold, and a second turbocharger in fluid communication with the outlet port of the second manifold. An exhaust aftertreatment device is in fluid communication with the first and second turbochargers. A turbocharger bypass circuit includes a valve assembly having an inlet side connected in fluid communication with the bypass runners of the first and second manifolds, an outlet side in fluid communication with the aftertreatment device, and a valve having an open position in which the inlet and outlet sides are in fluid communication and a closed position in which the inlet and outlet sides are not in fluid communication.

Plagens, Keith Michael↗

Scalability analysis of heavy-duty gas turbines using data-driven machine learning

With the increasing integration of variable renewable energy sources into power systems, the role of flexible power generation technologies like gas turbines (GT) in rapid grid balancing remains crucial. This sustained importance underscores the need for scaled and precise modeling of GT to ensure effective integration within evolving energy frameworks. While physics-driven GT models integrate thermodynamics, fluid dynamics, and combustion principles, they often rely on approximate mathematical representations to accommodate scaling that may not capture the actual complex dynamics for GTs and inertial effects associated to GTs with different ratings. In this study, a data-driven model is proposed using machine learning (ML) techniques to conduct GT scalability analysis and performance evaluation with high accuracy. The ML model, trained on data from various operating conditions and performance parameters, aims to uncover intricate relationships and patterns, resembling GT characteristics at different scales (ratings). The model is developed to capture complex system interaction and to adapt to changing operational scenarios at different capacities, providing valuable insights of power system dynamics. In this study, the real-time digital simulator platform was employed to generate training data for the ML model and assess its dynamic characteristics. The ultimate objective was to develop a detailed modeling framework based on governing equations and data-driven ML capable of predicting key performance indicators, in thermal systems such as GTs, including power output, speed, fuel consumption, and exhaust temperature under diverse operating conditions at different scales. The developed ML framework demonstrated high accuracy, with mean relative errors for GT power prediction, reference speed, exhaust temperature, and compressor pressure ratio (CPR) parameters consistently below 0.1% across typical load fluctuation scenarios. Maximum deviations were limited to approximately 0.5 K for exhaust temperature and 0.009 for CPR, underscoring the model’s ability to replicating dynamic GT behavior with high precision. The adaptability of the ML model enables its application across diverse operational conditions and its extension to other thermal systems. By leveraging advanced ML techniques, this study presents a robust and scalable modeling framework that enhances GT simulation precision, facilitating improved integration into evolving power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Potential for Electrons to Molecules Using Solar Energy

Solar photovoltaics (PV) do and will continue to play an important role in the electric power sector and can potentially support other sectors that are in need of decarbonized energy sources. Chemicals such as hydrogen, ammonia, and hydrocarbons including ethylene are currently produced from natural gas and crude oil. Thus, processes to produce them emit carbon dioxide and other greenhouse gases both directly and in upstream feedstock recovery processes. Electrons-to-molecules (E2M) technologies are being developed to convert carbon dioxide, water, and atmospheric nitrogen to desired chemical products and they are large electricity loads. Thus, they are emerging as a potential applications for PV. In its essence, they can act as electrochemical energy storage, thereby providing a means to further utilize the energy generated from PV and store it in molecular form. E2M systems offer an array of potential products and system designs that can be tailored to different end-uses and applications. It involves electrochemical conversion which uses electricity to break molecular bonds and produce new molecules. Various electrochemical conversion technologies split water into hydrogen and oxygen, reduce carbon dioxide into other hydrocarbon molecules, and several other possible combinations. While this Chapter does not attempt to provide an exhaustive summary or analysis of the potential products from E2M systems, it does provide an initial overview of the potential opportunities and challenges for PV and E2M systems in this space. This Chapter considers the potential for E2M to produce key chemicals and fuels that currently rely on hydrocarbons for production, either as a reactant or a source of high-grade heat.

14 SOLAR ENERGY↗

Final Design of Vacuum Pumping Systems for the Material Plasma Exposure eXperiment

The Material Plasma Exposure eXperiment (MPEX) vacuum pumping system is responsible for creating prototypic conditions in the plasma material interaction chamber that mimic those in a fusion reactor divertor region. Additionally, the vacuum system needs to minimize the pressure in the plasma heating region to improve the coupling of the electron cyclotron heating and ion cyclotron heating to the plasma, minimizing waste heat exhausted to high heat flux components. Here, the final design of the system has been sized to comply with the vacuum pump operating environment and to reduce the number of unique pumps required while meeting performance requirements. Bounding cases with and without the plasma present have been developed in the pumping analysis, and an initial calculation has been performed based on the plasma pumping identified in Proto-MPEX operation though this result will remain unverified until MPEX operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dataset for: Price Controls for Scarcity Events in Real-Time and Transactive Energy Systems

Real time pricing (RTP) is often promoted as a mechanism to improve the economic efficiency of the electricity system. However, many regulators have been hesitant to adopt RTP due to concerns about exposing customers to extreme price swings. To balance these concerns, this paper proposes a methodology for establishing price controls, based on the supply of demand-side flexibility in the system. As an illustrative example, we measure price responsiveness using an agent-based simulation model that is representative of the ERCOT market. The model is composed of a distribution feeder that has 250 customers with active agents controlling their HVAC systems in response to the historical ERCOT RTP with an artificially added high-price event. These agents are subjected to increasing electricity prices during the event, which we then use to create a supply curve for demand-side resources in our modeled scarcity event. We set potential price caps at points on the supply curve where customers’ have exhausted their flexible capacity. Using historical prices, we examine the systemic costs of these price caps, and present regulatory options for recouping them. Utilities and regulators interested in limiting consumer risk from dynamic pricing can utilize these methods to develop rate structures and encourage conservation. The attached data upload allows for the duplication or modification of the analysis performed in this study.

Kerby, Jessica R↗

Selective Pb 2+ removal and electrochemical regeneration of fresh and recycled FeOOH

Heavy metal pollution is a key environmental problem. Selectively extracting heavy metals could accomplish water purification and resource recycling simultaneously. Adsorption is a promising approach with a facile process, adaptability for the broad concentration of feed water, and high selectivity. However, the adsorption method faces challenges in synthesizing high-performance sorbents and regenerating adsorbents effectively. FeOOH is an environmentally friendly sorbent with low-cost production on a large scale. Nevertheless, the selectivity behavior and regeneration of FeOOH are seldom studied. Therefore, we investigated the selectivity of FeOOH in a mixed solution of Co 2+ , Ni 2+ , and Pb 2+ and proposed to enhance the capacity of FeOOH and regenerate it by using external charges. Without charge, the FeOOH electrode shows a Pb 2+ uptake capacity of 20 mg/g. After applying a voltage of –0.2/+0.8 V, the uptake capacity increases to a maximum of 42 mg/g and the desorption ratio is 70%–80%. In 35 cycles, FeOOH shows a superior selectivity towards Pb 2+ compared with Co 2+ and Ni 2+ , with a purity of 97% ± 3% in the extracts. The high selectivity is attributed to the lower activation energy for Pb 2+ sorption. The capacity retentions at the 5 th and the 35 th cycles are ca. 80% and ca. 50%, respectively, comparable to the chemical regeneration method. With industrially exhausted granular ferric hydroxide as the electrode material, the system exhibits a Pb 2+ uptake capacity of 37.4 mg/g with high selectivity. Our work demonstrates the feasibility of regenerating FeOOH by charge and provides a new approach for recycling and upcycling FeOOH sorbent.

36 MATERIALS SCIENCE↗

Making Coal Relevant for Small Scale Applications: Modular Gasification for Syngas/Engine CHP Applications in Challenging Environments

The proposed project includes construction and operation of a power plant consisting of coal gasification facilities and engine generators which would produce electrical power and heat. The recovered heat and a portion of the carbon dioxide emissions from the engines would support an onsite greenhouse and other heat and power customers. The proposed project site is located on the Marathon North Pole Terminal property in North Pole, Alaska. Two gasifiers would convert the coal into syngas, which would be fed through a gas cleanup train and then combusted in six reciprocating engines driving electric generators. Heat recovery on the engine cooling loops and exhaust trains would provide heat to a glycol/water circulation system for use in the greenhouse, in the Marathon facilities and for other customers. Natural gas would fuel two additional engine generators and would also be available to supplement the syngas-fired engines.

01 COAL, LIGNITE, AND PEAT↗

Divertor Component Testing

Power exhaust is an immense challenge in tokamaks. Commonwealth Fusion Systems (CFS), in collaboration with MIT and others, is working on the design of a compact (R 0 = 1.85 m), high-field (B 0 = 12 T) tokamak for the demonstration of net fusion energy, called SPARC. Empirical scaling laws indicate that the unmitigated heat flux in the boundary plasma will exceed 10 GW/m 2 . Such high heat fluxes will be a formidable challenge. The scope of this work is to utilize the HHF testing expertise maintained by ORNL, used in support of NSTX-U and to demonstrate the thermal performance of tungsten-coated graphitic foam targets, to help CFS and its collaborators to assess the performance of (1) base materials (tungsten and its alloys) and (2) divertor mockups under SPARC-like divertor heat flux conditions. These activities will be performed by ORNL personnel using electron beam exposure facilities at the Pennsylvania State University’s Applied Research Laboratory (ARL). ARL is a Department of Defense University Affiliated Research Center where ORNL has successfully executed NSTX-U and graphitic foam high heat flux testing using electron beam (e-beam) facilities, which is a nonstandard service. For the assessment of base materials, CFS will do an initial thermal analysis, in consultation with ORNL, to understand under what scenarios the materials are most likely to fail. CFS will supply to ORNL various tungsten-based material samples to test with testing taking 3 weeks. ORNL will thermally stress the samples under SPARC divertor-like conditions to either failure or to a prescribed number of pulses. ORNL will record experimental data, including IR surface temperature and embedded thermocouple readings, and report results to CFS

36 MATERIALS SCIENCE↗

Optimizing Solar PV Deployment in Manufacturing: A Morphological Matrix and Fuzzy TOPSIS Approach

The growing energy demand of the industrial sector and the need for sustainable solutions highlight the importance of efficient decision making in solar photovoltaic (PV) implementation. Selecting optimal PV configuration is complex due to the interdependent technical, economic, environmental, and social factors involved. This study introduces an integrated decision-making method combining a morphological matrix and fuzzy TOPSIS to systematically select and rank optimal PV system configurations for manufacturing firms. While the morphological matrix exhaustively examines possible design solutions based on sensing, smart, sustainable, and social (S4) attributes, the fuzzy TOPSIS method ranks the alternatives by handling uncertainty in decision making. A case study conducted in a Mexican manufacturing company validates the methodology’s effectiveness. The optimal PV configuration identified comprehensively addresses operational and sustainability criteria, covering all lifecycle stages. This approach demonstrates quantitative superiority and greater robustness compared to existing fuzzy TOPSIS-based methods for solar PV applications. The findings highlight the practical value of data-driven, multi-criteria decision making for industrial solar energy adoption, enhancing project feasibility, cost efficiency, and environmental compliance. Future research will incorporate discrete event simulation (DES) to further refine energy consumption strategies in manufacturing.

Briceño, Citlaly Pérez↗

Next Gen High Efficiency Boosted Engine Development

This work represents an advanced engineering research project partially funded by the U.S. Department of Energy (DOE). Ford Motor Company, FEV North America, and Oak Ridge National Laboratory collaborated to develop a next generation boosted spark ignited engine concept. The project goals, specified by the DOE, were 23% improved fuel economy and 15% reduced weight relative to a 2015 or newer light-duty vehicle. The fuel economy goal was achieved by designing an engine incorporating high geometric compression ratio, high dilution tolerance, low pumping work, and low friction. The increased tendency for knock with high compression ratio was addressed using early intake valve closing (EIVC), cooled exhaust gas recirculation (EGR), an active pre-chamber ignition system, and careful management of the fresh charge temperature. Engine weight reduction measures were implemented throughout the engine system making use of composite materials, advanced manufacturing techniques, and architectural choices. This report outlines the analytical, design, fabrication, and test work conducted for the duration of the project. The combustion system stability, EGR tolerance, and knock resistance were validated on a single cylinder engine. An inline six-cylinder engine was then designed targeting application in the Ford F150. Multi-cylinder engines were produced and tested achieving the target vehicle fuel economy improvement of 23% assessed using measured engine fuel consumption combined with a vehicle drive cycle simulation. Actions were identified and designs were demonstrated to achieve the 15% weight reduction target. This project included items covering a range of technology readiness levels. Some of the technologies explored are production ready, while others were investigated to understand the limitations for what can be achieved in a stoichiometric, gasoline-fueled, spark-ignited internal combustion engine.