At least 145 records · Page 8

Analysis of IECC (2003, 2006, 2009) and ASHRAE 90.1-2007 Commercial Energy Code Requirements for Mesa, AZ.

This report summarizes code requirements and energy savings of commercial buildings in Climate Zone 2B built to the 2009 IECC and ASHRAE Standard 90.1-2007 when compared to the 2003 IECC and the 2006 IECC. In general, the 2009 IECC and ASHRAE Standard 90.1-2007 have higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment. HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted. The energy analysis results show that commercial buildings meeting the 2009 IECC requirements save 4.4% to 9.5% site energy and 4.1% to 9.9% energy cost when compared to the 2006 IECC; and save 10.6% to 29.4% site energy and 10.3% to 29.3% energy cost when compared to the 2003 IECC. Similar analysis comparing ASHRAE Standard 90.1-2007 requirements to the 2006 IECC shows that the energy savings are in the 4.0% to 10.7% for multi-family and retail buildings, but less than 2% for office buildings. Further comparison of ASHRAE Standard 90.1-2007 requirements to the 2003 IECC show site energy savings in the range of 7.7% to 30.6% and energy cost savings range from 7.9% to 30.3%. Both the 2009 IECC and ASHRAE Standard 90.1-2007 have the potential to save energy by comparable levels for most building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of 2006 IECC and 2009 IECC Commercial Energy Code Requirements for Kansas City, MO

This report summarizes code requirements and energy savings of commercial buildings in climate zone 4 built to the 2009 IECC when compared to the 2006 IECC. In general, the 2009 IECC has higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment (HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted). The energy analysis results show that residential and nonresidential commercial buildings meeting the 2009 IECC requirements save between 6.1% and 9.0% site energy, and between 6.4% and 7.7% energy cost when compared to 2006 IECC. Analysis also shows that semiheated buildings have energy and cost savings of 3.9% and 5.6%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Foundation Insulation Strategies for the 2012 International Energy Conservation Code in Cold Climate New Home Construction

Even though the International Energy Conservation Code 2012 (International Code Council 2012) is a model code now available for adoption by individual states, only two cold-climate states have adopted it as their new home energy code. Understanding the resistance to adoption is important in assisting more states to accept the code and engage in deep energy strategies nationwide. This three-part assessment by the NorthernSTAR Building America Partnership was focused on foundation insulation R-values for cold climates and the design, construction, and performance implications. In Section 1, a literature review and attendance at stakeholder meetings held in Minnesota were used to assess general stakeholder interest and concerns about proposed code changes. Section 2 includes drawings of robust foundation insulation systems that were presented at one Minnesota stakeholder meeting to address critical issues and concerns for adopting best practice strategies. In Section 3, a sampling of builders participated in a telephone interview to gain baseline knowledge on insulation systems used to meet the current energy code and how the same builders intend to meet the new proposed code. In general, most builders expressed interest in being able to deliver greater energy efficiency to their customers. Concerns were voiced, however, about the costs compared to the energy savings, constructability, and durability risk resulting from increased foundation insulation R-values. When solutions for building robust foundation wall systems were presented to stakeholders, they did express interest in learning the details of the strategies. There was, however, continued interest in proof of cost, payback, and hygrothermal performance. Builders who participated in the interview were more confident in being able to meet the new requirements. This might have been a result of these respondents already using more advanced techniques for foundation insulation. This insight gives Building America an opportunity to engage the industry with existing research and practice measures that can address constructability and durability concerns at the proposed code levels. It also indicates that builders are interested in more specific information on cost, energy savings, and overall hygrothermal performance. Filling these voids could yield the supportive data needed to enhance building industry confidence and engage more states in the adoption of 2012 International Energy Conservation Code for new homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost Effective Electrochromic Glazing Repositioning For Insulating Glass & Secondary Windows

This project addressed both technical and economic objectives toward significantly increasing the availability of ElectroChromic (EC) dynamic architectural glass at reduced cost. In contrast to the prevailing industry location of the EC device layer on the exterior light of an Insulating Glass (IG) unit, Project Objectives assessed the feasibility of a) repositioning the device layer midway between two IG panes to configure triple glazing, and b) independently framed to enable positioning to the building interior independent of the original glass configured as a dynamic secondary window. Parallel research complementing both EC-IG and EC-WinSert configurations addressed integral Photo Voltaic, and ceiling mounted “broadcast” power to circumvent the significant onsite electrical con tracting normally associated with the installation of commercial EC glazing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Project Overcoat: Airtightness Strategies and Impacts for 1-1/2 Story Homes, Minneapolis, Minnesota (Fact Sheet)

In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 STORY BUNGALOW↗

Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 story bungalow↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the façade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution.This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre Omer↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the facade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution. This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre↗

Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 STORY BUNGALOW↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1 ½-Story Homes in Cold Climates

The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 ½-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 ½-Story House↗

Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1 ½-Story Homes in Cold Climates

The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 ½-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 1/2-Story House↗

Building America Case Study: Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1-1/2 Story Homes in Cold Climates, Minneapolis, MN (Fact Sheet)

The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 1/2-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 1/2-STORY HOUSE↗

Technology Solutions Case Study: Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1-1/2 Story Homes in Cold Climates, Minneapolis, MN

This case study describes the External Thermal and Moisture Management System developed by the NorthernSTAR Building America Partnership. This system is typically used in deep energy retrofits and is a valuable approach for the roof-only portions of existing homes, particularly the 1 1/2-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 1/2-STORY HOUSE↗

Investigation of Technologies to Improve Condenser Heat Transfer and Performance in a Relevant Coal-Fired Power Plant

Improvements in thermal power-generating plant performance is correlated directly to societal benefits including lower cost of reduced fuel consumption, resulting in lower cost of electricity for the consumer and reduced carbon emissions to the atmosphere. Warm steam exhausted from low-pressure steam turbines is condensed to liquid water on the exterior of thin-walled metal condenser tubes with cooling water passing through the tube interior. The condensation of steam creates a vacuum that supports turbine rotation and the concurrent generation of electricity. This vacuum is optimized when heat transfer across the wall of condenser tube is maximized. Common hindrances to heat transfer include foulants in cooling water that may form and adhere to the interior of condenser tubes, including mineral scale, microbiological films, and particulate deposition. Flowing cooling water may also include a laminar layer at the interior metal surfaces that travels more slowly than bulk water flow, serving to impede heat transfer. On the tube exterior, condensing steam forms an insulating layer of water that flows down the tube and reduces the effectiveness of cooling. Both the interior and exterior barriers to optimal heat transfer may be alleviated to some extent by surface treatments. On the tube interior, hydrophobic coatings may be applied that can reduced the adherence of foulants and of the laminar flow layer to the tube surface. On the tube exterior, hydrophobic coatings or mechanical treatments can be applied that may result in the termination of droplet growth and the departure of droplets from the surface rather than coalescence into a continuous layer of flowing water. Fourteen surface treatments were applied to condenser tubes in this study, including eight interior coatings and six exterior treatments, five of which were coatings and one a microstructural texture. Heat transfer measurement equipment simulating conditions in the condenser of an operating power plant was used to determine heat transfer coefficients by measuring sufficient flow, temperature, water chemistry and other data. Several of the tubes with interior surface treatments showed improvement in heat transfer coefficients compared with a plain (uncoated) tube, and several of the tubes with exterior surface treatments also showed enhanced heat transfer coefficients.

01 COAL, LIGNITE, AND PEAT↗

Newporter Apartments: Deep Energy Retrofit Short-Term Results

This project demonstrates a path to meet the goal of the Building America program to reduce home energy use by 30% in multi-family buildings. The project demonstrates cost effective energy savings targets as well as improved comfort and indoor environmental quality (IEQ) associated with deep energy retrofits by a large public housing authority as part of a larger rehabilitation effort. The project focuses on a typical 1960's vintage low-rise multi-family apartment community (120 units in three buildings).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting a 1960s Split-Level, Cold-Climate Home

National programs such as Home Performance with ENERGY STAR® and numerous other utility air-sealing programs have made homeowners aware of the benefits of energy-efficiency retrofits. Yet these programs tend to focus only on the low-hanging fruit: they recommend air sealing the thermal envelope and ductwork where accessible, switching to efficient lighting and low-flow fixtures, and improving the efficiency of mechanical systems (though insufficient funds or lack of knowledge to implement these improvements commonly prevent the implementation of these higher cost upgrades). At the other end of the spectrum, various utilities across the country are encouraging deep energy retrofit programs. Although deep energy retrofits typically seek 50% energy savings, they are often quite costly and are most applicable to gut-rehab projects. A significant potential for lowering energy use in existing homes lies between the lowhanging fruit and deep energy retrofit approaches—retrofits that save approximately 30% in energy compared to the pre-retrofit conditions. The energy-efficiency measures need to be nonintrusive so the retrofit projects can be accomplished in occupied homes.