Search NASA⌕ Search

SEARCH · Search NASA

Results for “Efficient Envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of building energy asset rating using stock modelling in the USA

The US Building Energy Asset Score helps building stakeholders quickly gain insight into the efficiency of building systems (envelope, electrical and mechanical systems). A robust, easy-to-understand 10-point scoring system was developed to facilitate an unbiased comparison of similar building types across the country. The Asset Score does not rely on a database or specific building baselines to establish a rating. Rather, distributions of energy use intensity (EUI) for various building use types were constructed using Latin hypercube sampling and converted to a series of stepped linear scales to score buildings. A score is calculated based on the modelled source EUI after adjusting for climate. A web-based scoring tool, which incorporates an analytical engine and a simulation engine, was developed to standardize energy modelling and reduce implementation cost. This paper discusses the methodology used to perform several hundred thousand building simulation runs and develop the scoring scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Campbell Creek Research Homes (FY 2012 Annual Performance Report)

The Campbell Creek project is funded and managed by the Tennessee Valley Authority (TVA) Technology Innovation, Energy Efficiency, Power Delivery and Utilization Office. Technical support is provided under contract by the Oak Ridge National Laboratory (ORNL) and the Electric Power Research Institute (EPRI). The project was designed to determine the relative energy efficiency of typical new home construction, energy efficiency retrofitting of existing homes, and high-performance new homes built from the ground up for energy efficiency. This project will compare three houses that represented the current construction practices: a base case (Builder House—CC1); a modified house that could represent a major energy-efficient retrofit (Retrofit House—CC2); and a house constructed from the ground up to be a high-performance home (High Performance House—CC3). To enable a valid comparison, it was necessary to simulate occupancy in all three houses and heavily monitor the structural components and the energy usage by component. All three houses are two story, slab on grade, framed construction. CC1 and CC2 are approximately 2,400 ft 2 . CC3 has a pantry option, primarily used as a mechanical equipment room, that adds approximately 100 ft 2 . All three houses are all-electric (with the exception of a gas log fireplace that is not used during the testing) and use air-source heat pumps for heating and cooling. The three homes are located in Knoxville in the Campbell Creek Subdivision. CC1 and CC2 are next door to each other and CC3 is across the street and a couple of houses down. The energy data collected will be used to determine the benefits of retrofit packages and high-performance new home packages. There are over 300 channels of continuous energy performance and thermal comfort data collection in the houses (100 for each house). The data will also be used to evaluate the impact of energy-efficient upgrades on the envelope, mechanical equipment, and demand-response options. Each retrofit will be evaluated incrementally, by both short-term measurements and computer modeling, using a calibrated model. This report is intended to document the comprehensive testing, data analysis, research, and findings within the January 2011 through October 2012 timeframe at the Campbell Creek research houses. The following sections will provide an in-depth assessment of the technology progression in each of the three research houses. A detailed assessment and evaluation of the energy performance of technologies tested will also be provided. Finally, lessons learned and concluding remarks will be highlighted.

Annual Report↗

Greenbelt Homes Pilot Energy Efficiency Program Phase 1 Summary: Existing Conditions and Baseline Energy Use

A multi-year pilot energy efficiency retrofit project has been undertaken by Greenbelt Homes, Inc, (GHI) a 1,566 co-operative of circa 1930 and '40 homes. The three predominate construction methods of the townhomes in the community are materials common to the area and climate zone including 8” CMU block, wood frame with brick veneer and wood frame with vinyl siding. GHI has established a pilot project that will serve as a basis for decision making for the roll out of a decade-long community upgrade program that will incorporate energy efficiency to the building envelope and equipment with the modernization of other systems like plumbing, mechanical equipment, and cladding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transition prediction using three dimensional stability analysis

Several methods of transition prediction by linear stability analysis are compared. The spectral stability analysis code SALLY is used to analyze flows over laminar flow control wings. It is shown that transition by the envelope method and a new modified wave packet method are comparable in reliability but that the envelope method is more efficient computationally.

Malik, M. R.↗

Influence of computational fluid dynamics on experimental aerospace facilities: A fifteen year projection

An assessment was made of the impact of developments in computational fluid dynamics (CFD) on the traditional role of aerospace ground test facilities over the next fifteen years. With improvements in CFD and more powerful scientific computers projected over this period it is expected to have the capability to compute the flow over a complete aircraft at a unit cost three orders of magnitude lower than presently possible. Over the same period improvements in ground test facilities will progress by application of computational techniques including CFD to data acquisition, facility operational efficiency, and simulation of the light envelope; however, no dramatic change in unit cost is expected as greater efficiency will be countered by higher energy and labor costs.

Source record↗

Performance of an optimized rotor blade at off-design flight conditions

An investigation is made of the dynamic and aerodynamic performance of a helicopter rotor previously optimized for minimum 4/rev vertical shear and blade weight subject to certain dynamic and structural constraints. The program CAMRAD which was used in designing the optimized blade is used for both dynamic and aerodynamic analaysis. The behavior of the optimized rotor is analyzed over a wide range of operating conditions and for a larger number of rotor characteristics than those considered in designing the blade. To assess the dynamic behavior, the blade root vibratory shears and moments that are transmitted to the rotor hub are calculated. The aerodynamic performance assessments are made based on the power required by the rotor for a given rotor task, the rotor lifting efficiencies, maximum rotor thrust envelopes and the control margins. Results are presented for the optimized blade and the control margins. Results are presented for the optimized blade and the reference blade, which was used as the baseline for the optimized blade, for two rotor tasks.

Chattopadhyay, Aditi↗

Performance of an optimized rotor blade at off-design flight conditions

An investigation is made of the dynamic and aerodynamic performance of a helicopter rotor previously optimized for minimum 4/rev vertical shear and blade weight subject to certain dynamic and structural constraints. The program CAMRAD which was used in designing the optimized blade is used for both dynamic and aerodynamic analysis. The behavior of the optimized rotor is analyzed over a wide range of operating conditions and for a larger number rotor characteristics than those considered in designing the blade. To assess the dynamic behavior, the blade root vibratory shears and moments that are transmitted to the rotor hub are calculated. The aerodynamic performance assessments are made based on the power required by the rotor for a given rotor task, the rotor lifting efficiencies, maximum rotor thrust envelopes and the control margins. Results are presented for the optimized blade and the reference blade which was used as the baseline for the optimized blade, for two rotor tasks.

Chattopadhyay, Aditi↗

Krypton Ion Thruster Performance

Preliminary data were obtained from a 30 cm ion thruster operating on krypton propellant over the input power range of 0.4 to 5.5 kW. The data presented are compared and contrasted to the data obtained with xenon propellant over the same input power envelope. Typical krypton thruster efficiency was 70 percent at a specific impulse of approximately 5000 s, with a maximum demonstrated thrust to power ratio of approximately 42 mN/kW at 2090 s specific impulse and 1580 watts input power. Critical thruster performance and component lifetime issues were evaluated. Order of magnitude power throttling was demonstrated using a simplified power-throttling strategy.

Patterson, Michael J.↗

Krypton ion thruster performance

Preliminary data were obtained from a 30 cm ion thruster operating on krypton propellant over the input power range of 0.4-5.5 kW. The data are presented, and compared and contrasted to those obtained with xenon propellant over the same input power envelope. Typical krypton thruster efficiency was 70 percent at a specific impulse of approximately 5000 s, with a maximum demonstrated thrust-to-power ratio of approximately 42 mN/kW at 2090 s specific impulse and 1580 watts input power. Critical thruster performance and component lifetime issues were evaluated. Order-of-magnitude power throttling was demonstrated using a simplified power-throttling strategy.

Patterson, Michael J.↗

Loss Mechanisms and Unsteady Flows in Turbomachines

The Conference Proceedings contains 42 papers presented at the Propulsion and Energetics Panel 85th Symposium on Loss Mechanisms and Unsteady Flows in Turbomachines which was held from 8-12 May 1995, in Derby, UK. Sessions: Cascade Steady Flow Mechanisms and Losses (9 papers); Steady Flow Clearance and Injection Flow Mechanisms and Losses (6); Steady Secondary Flows and Shock Boundary Layer Interaction (3); Blade Section-Wake Boundary layer Interaction (6); Management of Unsteady Flows (10); Blade Interactions (8). The Symposium contributes to improving the efficiency and operation of turbomachinery also in off-design conditions by application of experimental and computational fluid dynamics methods. Multi-stage methods and positive loss management in the design stage have been identified as next steps. This will yield optimized engines of high efficiency for expanded flight envelopes including active control of the plane movement at high reliability levels.

Advisory Group for Aerospace Research and Developm↗

Technology Solutions Case Study: Cold Climate Foundation Wall Hygrothermal Research Facility, Cloquet, Minnesota

This case study describes the University of Minnesota’s Cloquet Residential Research Facility (CRRF) in northern Minnesota, which features more than 2,500 ft2 of below-grade space for building systems foundation hygrothermal research. Here, the NorthernSTAR Building America Partnership team researches ways to improve the energy efficiency of the building envelope, including wall assemblies, basements, roofs, insulation, and air leakage.

basement foundation insulation↗

BETO 2021 Peer Review - Continuous Enzymatic Hydrolysis Development (CEHD) WBS 2.4.1.101

The Continuous Enzymatic Hydrolysis Development (CEHD) project aims to reduce the cost and commercialization scale-up risks of biorefinery sugar-lignin production through development of a deployable continuous enzymatic hydrolysis (CEH) process. Through the use of external cross flow membrane filtration loops coupled to enzymatic hydrolysis (EH) reactors, pretreated biomass solids and enzymes are retained for reaction while solubilized product sugars are removed in situ, with high extents of conversion achieved through a series of reactor-membrane unit stages. The CEHD project is focused on advancing CEH as a transformational, process-intensified, lower-cost method for producing soluble clarified biomass sugars and insoluble lignin-rich streams than traditional batch enzymatic hydrolysis (BEH). The project's primary objective is to reduce the cost of CEH to be compellingly lower than conventional BEH, 10% lower in year 1 and 20% lower in year 3 (end of project). A related objective is to expand CEH's operating envelope to increase process efficiency. Through more thorough de-risking and demonstration of CEH, in conjunction with building a suite of modeling and optimization tools that allow for more facile rigorous in silico evaluation of novel CEH designs and modalities, this project intends to elevate industry interest in adopting CEH as an improvement over conventional batch processing. This project was merit reviewed in FY20. It's now in its first year of a new 3-year plan spanning FY21-FY23.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption

Improving the performance of windows has the potential to reduce U.S. annual energy use by 1.7% and CO2 emissions by 1.9% in 2050. Beyond static windows, dynamic technologies could reduce U.S. annual energy use by 1.6 quads and CO2 emissions by 68 million metric tons. In addition, the widespread adoption of static and dynamic technologies would substantially reduce peak electricity demand from buildings. Beyond energy use and CO2 emissions reductions, improving window performance will increase occupant comfort and well-being. In a new report, Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption, the U.S. Department of Energy (DOE) outlines multiple avenues for technology development, deployment, and adoption to increase the impact that windows can have on decarbonizing America's buildings.

building energy efficiency↗

Today's Leaders for a Sustainable Tomorrow

Today's Leaders for a Sustainable Tomorrow is a collaboration of five residential environmental learning centers (Audubon Center of the North Woods, Deep Portage Learning Center, Laurentian Environmental Center, Long Lake Conservation Center and Wolf Ridge Environmental Learning Center) that together increased energy efficiency, energy conservation and renewable energy technologies through a number of different means appropriate for each unique center. For energy efficiency upgrades the centers installed envelope improvements to seal air barriers through better insulation in walls, ceilings, windows, doors as well as the installation of more energy efficient windows, doors, lighting and air ventilation systems. Through energy sub-meter monitoring the centers are able to accurately chart the usage of energy at each of their campuses and eliminate unnecessary energy usage. Facilities reduced their dependence on fossil fuel energy sources through the installation of renewable energy technologies including wood gasification, solar domestic hot water, solar photovoltaic, solar air heat, geothermal heating and wind power. Centers also installed energy education displays on the specific renewable energy technologies used at the center.

30 DIRECT ENERGY CONVERSION↗

Combined experimental and numerical evaluation of a prototype nano-PCM enhanced wallboard

In the United States, forty-eight (48) percent of the residential end-use energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase change material (PCM)-enhanced building envelopes can facilitate maximizing the energy efficiency of buildings. Combined experimental testing and numerical modeling of PCM-enhanced envelope components are two important aspects of the evaluation of their energy benefits. An innovative phase change material (nano-PCM) was developed with PCM encapsulated with expanded graphite (interconnected) nanosheets, which is highly conductive for enhanced thermal storage and energy distribution, and is shape-stable for convenient incorporation into lightweight building components. A wall with cellulose cavity insulation and prototype PCM-enhanced interior wallboards was built and tested in a natural exposure test (NET) facility in a hot-humid climate location. The test wall contained PCM wallboards and regular gypsum wallboard, for a side-by-side annual comparison study. Further, numerical modeling of the walls containing the nano-PCM wallboard was performed to determine its actual impact on wall-generated heating and cooling loads. The model was first validated using experimental data, and then used for annual simulations using Typical Meteorological Year (TMY3) weather data. This article presents the measured performance and numerical analysis evaluating the energy-saving potential of the nano-PCM-enhanced wallboard.

finite element analysis↗

Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings

In fall 2010, Greenbelt Homes, Inc. (GHI) a 1,566-home cooperative of circa 1930-1940 homes in Greenbelt, Maryland, undertook a multiyear pilot energy efficiency retrofit project. GHI established this pilot project as a basis for decision making for the rollout of a decade-long community-wide upgrade program that will incorporate energy-efficiency improvements to the building envelopes and mechanical equipment. The community upgrade is fully funded by the cooperative through its membership with no outside subsidies. This project thus presents a unique opportunity to evaluate and prioritize the wide range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, tradeoffs, construction methods, project management implications, realistic upfront costs, financing, and other considerations provides a case study for energy retrofit projects to include high-performance technologies based on the long-term value to the homeowner.

Array↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design analysis of levitation facility for space processing applications

Containerless processing facilities for the space laboratory and space shuttle are defined. Materials process examples representative of the most severe requirements for the facility in terms of electrical power, radio frequency equipment, and the use of an auxiliary electron beam heater were used to discuss matters having the greatest effect upon the space shuttle pallet payload interfaces and envelopes. Improved weight, volume, and efficiency estimates for the RF generating equipment were derived. Results are particularly significant because of the reduced requirements for heat rejection from electrical equipment, one of the principal envelope problems for shuttle pallet payloads. It is shown that although experiments on containerless melting of high temperature refractory materials make it desirable to consider the highest peak powers which can be made available on the pallet, total energy requirements are kept relatively low by the very fast processing times typical of containerless experiments and allows consideration of heat rejection capabilities lower than peak power demand if energy storage in system heat capacitances is considered. Batteries are considered to avoid a requirement for fuel cells capable of furnishing this brief peak power demand.

Frost, R. T.↗