At least 145 records · Page 8

Mitigating urban climate-energy feedback with citywide building-integrated photovoltaics implementation

Urban heat islands (UHIs) intensify cooling demands, whose waste heat further exacerbates UHI, creating a self-reinforcing feedback loop. Building-integrated photovoltaics (BIPV) can break this cycle by generating electricity and altering urban climate-energy interactions, yet its net impact remains unresolved. Using a cross-scale modeling framework for 118,521 buildings in Hong Kong, we demonstrate that BIPV glazing reduces cooling demand through improved insulation and lower solar heat gain, while inducing diurnal thermal asymmetry of daytime warming (up to +1.9°C) and nighttime cooling (up to −2.5°C). This microclimate regulation indirectly contributes to a 0.6% reduction in citywide building energy use. Cumulative savings from electricity generation and reduced energy use reach 4.7% (2,060.2 GWh) and 10.1% (4,401.3 GWh) under low- and high-coverage deployment, respectively, with building-level savings of −20.1% ± 11.7% (mean ± SD) at high coverage. We establish BIPV as a configurable climate-energy regulator that enables net-zero, heat-resilient planning and quantifies deployment trade-offs in cooling-dominated cities worldwide.

Building-integrated photovoltaics (BIPV)↗

Nationwide cost and capacity estimates for sedimentary basin geothermal power and implications for geologic CO 2 storage

Sedimentary basins are naturally porous and permeable subsurface formations that underlie approximately half of the United States. In addition to being targets for geologic CO 2 storage, these resources could supply geothermal power: sedimentary basin geothermal heat can be extracted with water or CO 2 and used to generate electricity. The geothermal power potential of these basins and the accompanying implication for geologic CO 2 storage are, however, understudied. Here, we use the Sequestration of CO 2 Tool (SCO2T PRO ) and the generalizable GEOthermal techno-economic simulator (genGEO) to address this gap by a) estimating the cost and capacity of sedimentary basin geothermal power plants across the United States and b) comparing those results to nationwide CO 2 sequestration cost and storage potential estimates. We find that across the United States, using CO 2 as a geothermal heat extraction fluid reduces the cost of sedimentary basin power compared to using water, and some of the lowest cost capacity occurs in locations not typically considered for their geothermal resources (e.g., Louisiana, South Dakota). Additionally, using CO 2 effectively doubles the sedimentary basin geothermal resource base, equating to hundreds of gigawatts of new capacity, by enabling electricity generation in geologies that are otherwise (with water) too impermeable, too thin, too cold, or not deep enough. We find there is competition for the best sedimentary basin resources between water- and CO 2 -based power, but no overlap between the lowest-cost resources for CO 2 storage and CO 2 -based power. In this way, our results suggest that deploying CO 2 -based power may increase the cost of water based systems (by using the best resources) and the cost of CO 2 storage (by storing CO 2 in locations that otherwise may not be targeted). As such, our findings demonstrate that determining the best role for sedimentary basins within the energy transition may require balancing tradeoffs between competing priorities.

CPG↗

The Importance of Engine External's Health

Engine external components include all the fluid carrying, electron carrying, and support devices that are needed to operate the propulsion system. These components are varied and include: pumps, valves, actuators, solenoids, sensors, switches, heat exchangers, electrical generators, electrical harnesses, tubes, ducts, clamps and brackets. The failure of any component to perform its intended function will result in a maintenance action, a dispatch delay, or an engine in flight shutdown. The life of each component, in addition to its basic functional design, is closely tied to its thermal and dynamic environment .Therefore, to reach a mature design life, the component's thermal and dynamic environment must be understood and controlled, which can only be accomplished by attention to design analysis and testing. The purpose of this paper is to review analysis and test techniques toward achieving good component health.

Stoner, Barry L.↗

Visions of the Future: Hybrid Electric Aircraft Propulsion

The National Aeronautics and Space Administration (NASA) is investing continually in improving civil aviation. Hybridization of aircraft propulsion is one aspect of a technology suite which will transform future aircraft. In this context, hybrid propulsion is considered a combination of traditional gas turbine propulsion and electric drive enabled propulsion. This technology suite includes elements of propulsion and airframe integration, parallel hybrid shaft power, turbo-electric generation, electric drive systems, component development, materials development and system integration at multiple levels.

electric motor vehicles↗

Methods and systems for syngas production and for efficient, flexible energy generation

Methods for producing syngas (e.g., H2 and CO) include introducing a stream comprising H2O and CO2 to a high-temperature co-electrolysis (HTCE) unit. A CO2 sweep gas is also introduced to the HTCE unit. Both H2O and CO2 are reduced in the HTCE unit to form the syngas and to form O2 that is swept away from the HTCE unit by the CO2 sweep gas, and the O2 and CO2 are then introduced to a combustion device (e.g., a gasifier), which may be configured to generate electrical power, as a result of combusting a carbonaceous fuel in the presence of the O2 and CO2. The HTCE unit is powered at least in part by power from an electricity-generating sub-system (e.g., at least one nuclear power plant). Related systems are also disclosed.

O'Brien, James E.↗

System and operation for thermochemical renewable energy storage

Systems and methods for energy storage and energy recovery are provided. An electrical-to-electrical energy storage system includes a thermochemical energy storage device, a blower, a compressor, a turbine, and an electrical generator. The TCES device includes a vessel, a porous bed, and a heater. The porous bed is disposed within an interior volume of the vessel. The porous bed comprises a reactive material. The reactive material is configured to release oxygen upon being heated to a reduction temperature, and generate heat when exposed to oxygen. The heater is in thermal contact with the reactive material. The blower is configured to remove oxygen from the interior volume. The compressor is configured to flow oxygen into the interior volume. The turbine is configured to receive a heated, oxygen-depleted gas from the interior volume. The generator is configured to be powered by the turbine to generate electricity.

Klausner, James F.↗

Blue Hydrogen – Not A Bad Idea

In this article, we will look at a technology that can generate hydrogen and power from gasification of a blend of biomass and coal with a “net negative” CO 2 footprint. Let us, however, first take a look at an earlier attempt to gasify coal and generate electric power with pre-combustion CO 2 capture. While the attempt was not exactly a stellar success, at least based on what can be gleaned from superficial press articles, the reality is quite different. This is why it deserves a closer look because its demise was a significant factor (by no means the only one, though) in putting an end to the efforts to maintain coal as a viable option for electricity generation (see the 2007 GTW article on that subject.

01 COAL, LIGNITE, AND PEAT↗

Thermochemical renewable energy storage

Systems and methods for energy storage and energy recovery are provided. An electrical-to-electrical energy storage system includes a thermochemical energy storage device, a blower, a compressor, a turbine, and an electrical generator. The TCES device includes a vessel, a porous bed, and a heater. The porous bed is disposed within an interior volume of the vessel. The porous bed comprises a reactive material. The reactive material is configured to release oxygen upon being heated to a reduction temperature, and generate heat when exposed to oxygen. The heater is in thermal contact with the reactive material. The blower is configured to remove oxygen from the interior volume. The compressor is configured to flow oxygen into the interior volume. The turbine is configured to receive a heated, oxygen-depleted gas from the interior volume. The generator is configured to be powered by the turbine to generate electricity.

Klausner, James F.↗

Switching of electrochemical selectivity due to plasmonic field-induced dissociation

Electrochemical reactivity is known to be dictated by the structure and composition of the electrocatalyst–electrolyte interface. Here, we show that optically generated electric fields at this interface can influence electrochemical reactivity insofar as to completely switch reaction selectivity. We study an electrocatalyst composed of gold–copper alloy nanoparticles known to be active toward the reduction of CO 2 to CO. However, under the action of highly localized electric fields generated by plasmonic excitation of the gold–copper alloy nanoparticles, water splitting becomes favored at the expense of CO 2 reduction. Real-time time-dependent density functional tight binding calculations indicate that optically generated electric fields promote transient-hole-transfer-driven dissociation of the O─H bond of water preferentially over transient-electron-driven dissociation of the C─O bond of CO 2 . These results highlight the potential of optically generated electric fields for modulating pathways, switching reactivity on/off, and even directing outcomes.

Alcorn, Francis M.↗

Wind wheel electric power generator

Wind wheel electric power generator apparatus includes a housing rotatably mounted upon a vertical support column. Primary and auxiliary funnel-type, venturi ducts are fixed onto the housing for capturing wind currents and conducting to a bladed wheel adapted to be operatively connected with the generator apparatus. Additional air flows are also conducted onto the bladed wheel; all of the air flows positively effecting rotation of the wheel in a cumulative manner. The auxiliary ducts are disposed at an acute angle with respect to the longitudinal axis of the housing, and this feature, together with the rotatability of the housing and the ducts, permits capture of wind currents within a variable directional range.

Kaufman, J. W.↗

Portable generator having a configurable load bank

A portable generator includes a combustion engine. The portable generator includes an electric generator coupled to the combustion engine. The portable generator can include a load bank. When the electric generator operates at a first voltage and generates less than a threshold amount, the load bank is coupled to the electric generator in a first configuration. When the electric generator operates at a second voltage that is different than the first voltage, the load bank is coupled to the electric generator in a second configuration that is different than the first configuration.

42 ENGINEERING↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam G.↗

Optimizing the fuel efficiency of an opposed piston engine for electric power generation

This paper investigates the optimal crankshaft motion for an opposed piston (OP) engine in a novel hybrid architecture to maximize fuel efficiency. The OP engine was selected for this work due to its inherent thermodynamic benefits and the balanced nature of the engine which can achieve downsizing through reducing the number of cylinders rather than the individual cylinder volume. The typical geartrain required on an OP engine was exchanged for two electric motors, reducing friction loss and decoupling the crankshafts. Using the motors to control the crankshaft motion profiles, this architecture introduces capabilities to dynamically vary compression ratio, combustion volume, and scavenging dynamics. To leverage these opportunities, an optimization scheme was developed utilizing nonlinear optimization of a 0-D model to compute the crankshaft motion profile that maximizes the work generated by the system. This optimization was then iteratively coupled with a high fidelity model which supplies the cylinder flow boundary conditions. This iterative approach reduces the model complexity used in the optimal control problem (OCP) while capturing the gas exchange dynamics critical to the 2-stroke cycle of the OP engine. By using the rate of change of motor torque as the input to the OCP, the torque fluctuation in a single cycle can be limited to ensure tracking feasibility. The results show crankshaft velocity slows during the compression stroke and conversely accelerates during the expansion stroke, reducing the peak motor torque required for control and thus reducing the motor losses. The extended residence time at top dead center, however, leads to an increase in heat transfer, illustrating the trade-off between the work extraction efficiency and the indicated engine efficiency.

Engineering↗