Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Systems special investigation group overview

The Systems Special Investigation Group (SIG) has undertaken investigations in the four major engineering disciplines represented in the Long Duration Exposure Facility (LDEF) hardware: electrical, mechanical, thermal, and optical systems. Testing was planned for the highest possible level of assembly, and top level system tests for nearly all systems were performed at this time. To date, testing was performed on a mix of LDEF and individual experimenter systems. No electrical or mechanical system level failures attributed to the spaceflight environment have yet been detected. Some low cost electrical components were used successfully, although relays were a continuing problem. Mechanical galling was observed unexpectedly, but no evidence of cold welding was identified yet. A working index of observed systems anomalies was created and will be used to support the tracking and resolution of these effects. The LDEF hardware currently available to the Systems SIG includes most of the LDEF systems hardware, and some significant experimenter hardware as well. A series of work packages was developed for each of several subsystem types where further testing is of critical interest. The System SIG is distributing a regular newsletter to the greater LDEF community in order to maintain coherence in an investigation which is widely scattered both in subject matter and in geography. Circulation of this informal document has quadrupled in its first year.

Mason, James B.↗

Maser cavity servo-tuning system

Two collocated, weakly coupled probes, one loop and one dipole, detect the magnetic and electric fields inside a maser cavity. Signals from the probes are compared in phase, and the signal output from the phase detector is applied to a varactor, the reactance of which is coupled into the cavity by a microwave coupler. Alternatively, the varactor may be placed inside the cavity. Any deviation of phase from 90 deg as detected by the phase detector will then produce an error signal that will change the reactance coupled into the resonant cavity to change its reactance, and thus correct its resonance frequency. An alternative to using two probes is to use a single disk probe oriented to detect both the magnetic and electric fields, and thus provide the error signal directly.

Sydnor, R. L.↗

NASA thunderstorm overflight program: Atmospheric electricity research. An overview report on the optical lightning detection experiment for spring and summer 1983

This report presents an overview of the NASA Thunderstorm Overflight Program (TOP)/Optical Lightning Experiment (OLDE) being conducted by the Marshall Space Flight Center and university researchers in atmospheric electricity. Discussed in this report are the various instruments flown on the NASA U-2 aircraft, as well as the ground instrumentation used in 1983 to collect optical and electronic signatures from the lightning events. Samples of some of the photographic and electronic signatures are presented. Approximately 4132 electronic data samples of optical pulses were collected and are being analyzed by the NASA and university researchers. A number of research reports are being prepared for future publication. These reports will provide more detailed data analysis and results from the 1983 spring and summer program.

Vaughan, O. H., Jr.↗

Application of the Nimbus 5 ESMR to rainfall detection over land surfaces

The ability of the Nimbus 5 Electrically Scanning Microwave Radiometer (ESMR) to detect rainfall over land surfaces was evaluated. The ESMR brightness temperatures (Tb sub B) were compared with rainfall reports from climatological stations for a limited number of rain events over portions of the U.S. The greatly varying emissivity of land surfaces precludes detection of actively raining areas. Theoretical calculations using a ten-layer atmospheric model showed this to be an expected result. Detection of rain which had fallen was deemed feasible over certain types of land surfaces by comparing the Tb sub B fields before and after the rain fell. This procedure is reliable only over relatively smooth terrain having a substantial fraction of bare soil, such as exists in major agricultural regions during the dormant or early growing seasons. Soil moisture budgets were computed at selected sites to show how the observed emissivity responded to changes in the moisture content of the upper soil zone.

Meneely, J. M.↗

Synergistic Use of Nighttime Satellite Data, Electric Utility Infrastructure, and Ambient Population to Improve Power Outage Detections in Urban Areas

Natural and anthropogenic hazards are frequently responsible for disaster events, leading to damaged physical infrastructure, which can result in loss of electrical power for affected locations. Remotely-sensed, nighttime satellite imagery from the Suomi National Polar-orbiting Partnership (Suomi-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) can monitor power outages in disaster-affected areas through the identification of missing city lights. When combined with locally-relevant geospatial information, these observations can be used to estimate power outages, defined as geographic locations requiring manual intervention to restore power. In this study, we produced a power outage product based on Suomi-NPP VIIRS DNB observations to estimate power outages following Hurricane Sandy in 2012. This product, combined with known power outage data and ambient population estimates, was then used to predict power outages in a layered, feedforward neural network model. We believe this is the first attempt to synergistically combine such data sources to quantitatively estimate power outages. The VIIRS DNB power outage product was able to identify initial loss of light following Hurricane Sandy, as well as the gradual restoration of electrical power. The neural network model predicted power outages with reasonable spatial accuracy, achieving Pearson coefficients (r) between 0.48 and 0.58 across all folds. Our results show promise for producing a continental United States (CONUS)- or global-scale power outage monitoring network using satellite imagery and locally-relevant geospatial data.

da/night band↗

Magnetospheric electron density measurements from upper hybrid resonance noise observed by IMP-6

A band of natural radio noise between the local electron plasma frequency and the upper hybrid resonance frequency is observed by the IMP-6 satellite. The band exists over a large range of geocentric radial distances extending from inside the plasmapause boundary to greater than 10 earth radii in the outer magnetosphere. The center frequency of the noise band decreases with increasing radial distance, and changes abruptly at the plasmapause boundary. The broadband electric field strength of this noise is very small, seldom exceeding 10 microvolts/meter, and probably could not be detected without using long electric antennas of IMP-6. It is believed that this noise is produced by incoherent Cerenkov emission from super-thermal electrons. In some cases a second very narrow noise band was observed at a frequency slightly above the second harmonic of the electron gyrofrequency.

Shaw, R. R.↗

High-resolution spectrograms of ion acoustic waves in the solar wind

High-resolution, frequency-time spectrograms of ion acoustic waves in the solar wind obtained by the Voyager spacecraft at distances of up to 1.7 AU are examined. The plasma wave instrument on board the Voyager spacecraft used to acquire the spectra employs an electric dipole antenna with a 16-channel step frequency receiver and a high-bit-rate waveform receiver to detect and measure the electric field of plasma waves. Voyager spectrograms show that the ion acoustic waves consist of narrowband, rapidly varying bursts, lasting a few seconds or less, usually in the range between the plasma ion and electron frequencies. Spectrograms taken at 1.7 AU are shown to be essentially identical to similar measurements taken upstream of the earth's magnetosphere, which are produced by suprathermal protons streaming into the solar wind from the bow shock, and to those taken upstream of interplanetary shocks.

Kurth, W. S.↗

Dynamic variations observed in thermal and superthermal ion distributions in the dayside ionosphere of Venus

In-situ measurements of the ion composition and concentration of the ionosphere of Venus are obtained with the Bennett RF ion mass spectrometer (OIMS) on the Pioneer Venus Orbiter (PVO). Dayside ion profiles exhibit considerable variability in the height of the ionopause as well as the scale heights of the ion constituents, which reflect the compression and expansion of the ionosphere in response to solar wind variations. Near the dayside upper boundary of the thermal O+ distribution, super-thermal ions are detected by the OIMS, presenting a complication for identifying the ion signature of the ionopause. Correlated with the presence of the superthermal ions, the ac electric field detector (OEFD) detects regions of intensified signals, with peak response in the 100 Hz frequency channel. It is expected that further analysis of the superthermal ion-electric field signatures will contribute to a clearer understanding of the physical processes underlying the formation of the ionopause.

Taylor, H. A., Jr.↗

Damage Characterization in SiC/SiC Composites using Electrical Resistance

SiC/SiC ceramic matrix composites (CMCs) under creep-rupture loading accumulate damage by means of local matrix cracks that typically form near a stress concentration, such as a 90o fiber tow or large matrix pore, and grow over time. Such damage is difficult to detect through conventional techniques. Electrical resistance changes can be correlated with matrix cracking to provide a means of damage detection. Sylramic-iBN fiber-reinforced SiC composites with both melt infiltrated (MI) and chemical vapor infiltrated (CVI) matrix types are compared here. Results for both systems exhibit an increase in resistance prior to fracture, which can be detected either in situ or post-damage.

Smith, Craig E.↗

Simple Method For Detection Of Intergranular Attack

Evidence of intergranular attack occurring on chemically milled and wire-electrical-discharge-machined metal parts detected with replicating tape which makes it unnecessary to manufacture and stock test coupons and inspect them microscopically. Tape pressed on part to be inspected. When removed, it presents visual evidence of intergranular attack.

Jackson, Amy A.↗

An autonomous fault detection, isolation, and recovery system for a 20-kHz electric power distribution test bed

Future space explorations will require long term human presence in space. Space environments that provide working and living quarters for manned missions are becoming increasingly larger and more sophisticated. Monitor and control of the space environment subsystems by expert system software, which emulate human reasoning processes, could maintain the health of the subsystems and help reduce the human workload. The autonomous power expert (APEX) system was developed to emulate a human expert's reasoning processes used to diagnose fault conditions in the domain of space power distribution. APEX is a fault detection, isolation, and recovery (FDIR) system, capable of autonomous monitoring and control of the power distribution system. APEX consists of a knowledge base, a data base, an inference engine, and various support and interface software. APEX provides the user with an easy-to-use interactive interface. When a fault is detected, APEX will inform the user of the detection. The user can direct APEX to isolate the probable cause of the fault. Once a fault has been isolated, the user can ask APEX to justify its fault isolation and to recommend actions to correct the fault. APEX implementation and capabilities are discussed.

Quinn, Todd M.↗

Detecting Conductive Liquid Leaking from Nonconductive Pipe

A method that can be implemented with relatively simple electronic circuitry provides a capability for detecting leakage of an electrically conductive liquid from an electrically nonconductive underground pipe. Alternatively or in addition, the method can be applied to locate the pipe, whether or not there is a leak. Although the method is subject to limitations (some of which are described below), it is still attractive as an additional option for detecting leaks and locating pipes without need for extensive digging. The method is based on capacitive coupling of an alternating electrical signal from the liquid to a portable electronic unit that resembles a metal detector. A signal voltage is applied to the liquid at some convenient point along the pipe: for example, the signal could be coupled into the liquid via an aboveground metal pipe fitting, the interior surface of which is in contact with the liquid. The signal is conducted through the liquid in the pipe; in the case of diffusive leak of liquid into the surrounding ground, the signal is conducted through the leak, into the portion of the adjacent ground that has become soaked with the liquid. (A drip leak cannot be detected by this method because there is no conductive path between the liquid inside and the liquid outside the pipe.) The portable unit includes an electrically conductive plate connected to the input terminal of an amplifier. When the plate is brought near the pipe or the leaked liquid, a small portion of the signal power is coupled capacitively from the liquid to the plate. The user scans the plate near the ground surface to find the locus of maximum signal strength. The leak can be identified as a relatively wide area, contiguous with the location of the pipe, over which the signal is detectable.

Youngquist, Robert C.↗

Electrical Resistance of SiC/SiC Ceramic Matrix Composites for Damage Detection and Life-Prediction

Ceramic matrix composites (CMC) are suitable for high temperature structural applications such as turbine airfoils and hypersonic thermal protection systems due to their low density high thermal conductivity. The employment of these materials in such applications is limited by the ability to accurately monitor and predict damage evolution. Current nondestructive methods such as ultrasound, x-ray, and thermal imaging are limited in their ability to quantify small scale, transverse, in-plane, matrix cracks developed over long-time creep and fatigue conditions. CMC is a multifunctional material in which the damage is coupled with the material s electrical resistance, providing the possibility of real-time information about the damage state through monitoring of resistance. Here, resistance measurement of SiC/SiC composites under mechanical load at both room temperature monotonic and high temperature creep conditions, coupled with a modal acoustic emission technique, can relate the effects of temperature, strain, matrix cracks, fiber breaks, and oxidation to the change in electrical resistance. A multiscale model can in turn be developed for life prediction of in-service composites, based on electrical resistance methods. Results of tensile mechanical testing of SiC/SiC composites at room and high temperatures will be discussed. Data relating electrical resistivity to composite constituent content, fiber architecture, temperature, matrix crack formation, and oxidation will be explained, along with progress in modeling such properties.

Smith, Craig↗

Electrical-ground monitor

Instrument for detecting short circuits monitors ground connections and sounds alarm if out-of-limits condition occurs. Circuit includes electronics that prevent false triggering by high-resistance or capacitive paths and other noise.

Lyons, T. D.↗

The Surface Interface Characteristics of Vertically Aligned Carbon Nanotube and Graphitic Carbon Fiber Arrays Grown by Thermal and Plasma Enhanced Chemical Vapor Deposition

The development of nano-arrays for sensors and devices requires the growth of arrays with the proper characteristics. One such application is the growth of vertically aligned carbon nanotubes (CNTs) and graphitic carbon fibers (GCFs) for the chemical attachment of probe molecules. The effectiveness of such an array is dependent not only upon the effectiveness of the probe and the interface between that probe and the array, but also the array and the underlaying substrate. If that array is a growth of vertically aligned CNTs or GCFs then the attachment of that array to the surface is of the utmost importance. This attachment provides the mechanical stability and durability of the array, as well as, the electrical properties of that array. If the detection is to be acquired through an electrical measurement, then the appropriate resistance between the array and the surface need to be fabricated into the device. I will present data on CNTs and GCFs grown from both thermal and plasma enhanced chemical vapor deposition. The focus will be on the characteristics of the metal film from which the CNTs and GCFs are grown and the changes that occur due to changes within the growth process.

Delzeit, Lance↗

Evidence of drift waves at the plasmapause

As the Hawkeye 1 spacecraft crosses the plasmapause at high altitudes, (R greater than 3 R/E/), a band of electric field noise is often detected in the frequency channels from 1.7 to 178 Hz. No corresponding magnetic field noise is detected, indicating that the noise is electrostatic (or at least quasi-electrostatic), and the electric field is polarized perpendicular to the plasma density gradient. The noise is only detected when the scale length of the plasmapause is 0.1 R(E) or less, indicating that a large density gradient is required to produce the noise. These characteristics are all consistent with the interpretation that this noise consists of electrostatic waves excited by the drift mode instability. By using reasonable assumptions concerning the wavelengths of these waves the observed frequency spectrum can be explained as being due to Doppler shifts caused by spacecraft motion through the plasma.

Kintner, P. M.↗

The temporal evolution of 3-m striations in the modified ionosphere

Experiments were performed at Arecibo, Puerto Rico, to investigate the evolution times of 3-m field-aligned striations produced in the ionosphere by powerful high-frequency (HF) radio waves. The results of this investigation are now summarized. First, the striations' rise times are dependent on the HF electric field. The E region data suggest that this dependence is nonlinear. Second, the threshold value of the HF electric field required to produce detectable striations was experimentally determined. At threshold the component of the HF electric field perpendicular to the geomagnetic field is calculated to be 0.09 V/m in the F region and 0.37 V/m in the E region. Third, both the E and the F region data verify theoretical predictions that the striations' decay times are directly proportional to the electron diffusion across B. Finally, a one-to-one correspondence between the growth of the 3-m striations and the decline of the HF-enhanced plasma line during overshoot is sometimes observed.

Coster, A. J.↗

Development of Solid-State Nanopore Technology for Life Detection

Biomarkers for life on Earth are an important starting point to guide the search for life elsewhere. However, the search for life beyond Earth should incorporate technologies capable of recognizing an array of potential biomarkers beyond what we see on Earth, in order to minimize the risk of false negatives from life detection missions. With this in mind, charged linear polymers may be a universal signature for life, due to their ability to store information while also inherently reducing the tendency of complex tertiary structure formation that significantly inhibit replication. Thus, these molecules are attractive targets for biosignature detection as potential "self-sustaining chemical signatures." Examples of charged linear polymers, or polyelectrolytes, include deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) as well as synthetic polyelectrolytes that could potentially support life, including threose nucleic acid (TNA) and other xenonucleic acids (XNAs). Nanopore analysis is a novel technology that has been developed for singlemolecule sequencing with exquisite single nucleotide resolution which is also well-suited for analysis of polyelectrolyte molecules. Nanopore analysis has the ability to detect repeating sequences of electrical charges in organic linear polymers, and it is not molecule- specific (i.e. it is not restricted to only DNA or RNA). In this sense, it is a better life detection technique than approaches that are based on specific molecules, such as the polymerase chain reaction (PCR), which requires that the molecule being detected be composed of DNA.

Bywaters, K. B.↗