Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Conservation Measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A multi-product landscape life-cycle assessment approach for evaluating local climate mitigation potential

Increasing demand for land-based climate mitigation requires more efficient management of agricultural landscapes for competing objectives. Here we develop methods for assessing trade-offs and synergies between intensification and carbon-sequestering conservation measures in annual crop production landscapes using the DayCent ecosystem model and the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) life-cycle assessment (LCA) model. We compiled county-scaled crop yields, fertilizer application rates, and tillage intensity for a corn–soybean farming case study landscape in the US state of Iowa. Using DayCent, we estimated a baseline soil organic carbon (SOC) accrual rate of 0.29 Mg C ha -1 y -1 driven by historical increases in crop productivity and reductions in tillage intensity. We then simulated the effects of management interventions targeted toward intensification (stover removal) and SOC sequestration (tillage intensity reduction and winter cover crop addition) individually and in combination. We propose a new multi-product landscape–LCA approach that analyzes marginal changes in corn grain, corn stover, and soybean production from the landscape in terms of their value for biofuel production (corn ethanol, soy biodiesel, and cellulosic ethanol from stover) and associated net displacement of conventional fossil-derived fuel use. This enables us to evaluate both intensification and sequestration effects in common CO 2 -equivalent mitigation units. We also used DayCent-simulated yields under the different land management scenarios to estimate farm-level costs and revenues. Our results show that intensification via collecting 30% of corn stover for biofuel production would increase the total greenhouse gas (GHG) mitigation potential of this landscape by 0.93 Mg CO 2 e ha -1 y -1 and provide $49 ha -1 y -1 of additional net revenue from biomass sales, but would reduce the baseline SOC accumulation rate by approximately 40%. In contrast, integrated approaches that include co-adoption of winter cover cropping and/or tillage intensity reduction would result in increased rates of SOC accumulation above the baseline, achieving simultaneous improvements in both farm profits and the overall GHG mitigation potential of the landscape.

54 ENVIRONMENTAL SCIENCES↗

Empirical Model of Puncture Energy for Metals

The purpose of this work is to fit a previously developed empirical equation for puncture energy to simulation data. The conservative puncture energy equation could be used to expedite the process of performing calculations in the development of safety measures, avoiding the need to create complex finite element models for specific puncture scenarios. A total of 108 simulations are developed by varying coupon thickness, coupon material, probe shape, and probe diameter. The simulations are comprised of a low-velocity probe puncturing the coupons, from which the probe kinetic energy change is calculated. The empirical equation is fit to the dimensions, material properties, and energy results using a non-linear least-squares regression method within Python, which determines the two constant parameters for each fit. More statistically significant fit results are achieved by separating the data by probe shape and coupon material.

42 ENGINEERING↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

University of Miami Industrial Assessment Center (Final Scientific/Technical Report)

The University of Miami Industrial Assessment Center (MIIAC) is located at the Department of Industrial & Systems Engineering in the College of Engineering at University of Miami. The Center has conducted 402 energy assessments with estimated Total Energy Savings over $\$57.3$ million, Total Non- Energy Cost Savings of $\$23.7$ million, and Total Energy Saving as a 26% of Energy Costs of $\$311$ million. A total of 6.01 TBtu of energy savings were recommended as a result of energy efficiency measures resulting in $\$81$ million in cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing Residential Energy Usage Baselines and Energy Efficiency Options

FCPC has been a leader in energy conservation not only in the State of Wisconsin, but nationally, as well. In 2016, the Environmental Protection Agency (EPA) ranked FCPC 11th in its Top 30 Local Government List as a result of the extensive measures the Tribe has taken toward its goal of achieving 100% carbon-neutral energy independence. Some of these efforts include the reduction of the Tribal government workweek to four days instead of five, the purchase of renewable energy certificates to more than offset the Tribe’s annual energy consumption, the installation of solar photovoltaic systems, and the completion of energy audits of Tribal government facilities. Until now, FCPC has focused on energy efficiency options for government and enterprise buildings, but it is now time to broaden the scope of energy efficiency to include the Tribe’s residential community. The Tribe’s Energy Working Group has identified the completion of home energy audits as one of its more imminent goals, as formal energy evaluations have yet to be completed on residential dwellings on the FCPC reservation. Tribal leadership is already looking ahead to the anticipated outcome of these energy audits and has taken steps to develop a cost sharing program that will assist Tribal homeowners to implement identified efficiency options as a result of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase-matching measurements for 10-microns upconversion in AgGaS2

Laboratory data from the upconversion of CO2 laser radiation using an AgGaS2 crystal pumped with a tunable dye laser are reported. Data were taken on the pump wavelength and bandwidth and the crystal acceptance angle for phase-matching. The results were compared with predictions made in terms of the upconversion conservation of energy and momentum and a model of the AgGaS2 refractive index. The trials were run with an annealed crystal apparently free of cracks, twins and optical scattering centers. The measurements indicated that more accurate refractrive-index data are required to be able to predict accurately the laser pump wavelength for phase-matching.

Itabe, T.↗

Specifying Calibration of Energy-Measuring Equipment

A report on calibrating energy-measuring equipment to maximize energy efficiency of lighting and other systems. The report describes best practices for accrediting calibration laboratories and for calibrating measuring equipment, compares and contrasts service providers accredited for energy-measuring equipment calibration, presents a tailorable specification template for requesting such calibration, and offers recommendations to a range of stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation of a Water Flow Control System into the ISS'S Planned Fluids & Combustion Facility

The Fluids and Combustion Facility (FCF) will become an ISS facility capable of performing basic combustion and fluids research. The facility consists of two independent payload racks specifically configured to support multiple experiments over the life of the ISS. Both racks will depend upon the ISS's Moderate Temperature Loop (MTL) for removing waste heat generated by the avionics and experiments operating within the racks. By using the MTL, constraints are imposed by the ISS vehicle on how the coolant resource is used. On the other hand, the FCF depends upon effective thermal control for maximizing life of the hardware and for supplying proper boundary conditions for the experiments. In the implementation of a design solution, significant factors in the selection of the hardware included ability to measure and control relatively low flow rates, ability to throttle flow within the time constraints of the ISS MTL, conserve energy usage, observe low mass and small volume requirements. An additional factor in the final design solution selection was considering how the system would respond to a loss of power event. This paper describes the method selected to satisfy the FCF design requirements while maintaining the constraints applied by the ISS vehicle.

Edwards, Daryl A.↗

Numerical Analysis of Mixed-Phase Icing Cloud Simulations in the NASA Propulsion Systems Laboratory

This presentation describes the development of a numerical model that couples the thermal interaction between ice particles, water droplets, and the flowing gas of an icing wind tunnel for simulation of NASA Glenn Research Centers Propulsion Systems Laboratory (PSL). The ultimate goal of the model is to better understand the complex interactions between the test parameters and have greater confidence in the conditions at the test section of the PSL tunnel. The model attempts to explain the observed changes in test conditions by coupling the conservation of mass and energy equations for both the cloud particles and flowing gas mass. Model predictions were compared to measurements taken during May 2015 testing at PSL, where test conditions varied gas temperature, pressure, velocity and humidity levels, as well as the cloud total water content, particle initial temperature, and particle size distribution.

NASA PSL↗

Numerical Analysis of Mixed-Phase Icing Cloud Simulations in the NASA Propulsion Systems Laboratory

This paper describes the development of a numerical model that couples the thermal interaction between ice particles, water droplets, and the flowing gas of an icing wind tunnel for simulation of NASA Glenn Research Centers Propulsion Systems Laboratory (PSL). The ultimate goal of the model is to better understand the complex interactions between the test parameters and have greater confidence in the conditions at the test section of the PSL tunnel. The model attempts to explain the observed changes in test conditions by coupling the conservation of mass and energy equations for both the cloud particles and flowing gas mass. Model predictions were compared to measurements taken during May 2015 testing at PSL, where test conditions varied gas temperature, pressure, velocity and humidity levels, as well as the cloud total water content, particle initial temperature, and particle size distribution.

NASA PSL↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Beginner's Guide to Power and Energy Measurement and Estimation for Computing and Machine Learning

Concerns about the environmental footprint of machine learning are increasing. While studies of energy use and emissions of ML models are a growing subfield, most ML researchers and developers still do not incorporate energy measurement as part of their work practices. While measuring energy is a crucial step towards reducing carbon footprint, it is also not straightforward. This paper introduces the main considerations necessary for making sound use of energy measurement tools and interpreting energy estimates, including the use of at-the-wall versus on-device measurements, sampling strategies and best practices, common sources of error, and proxy measures. It also contains practical tips and real-world scenarios that illustrate how these considerations come into play. It concludes with a call to action for improving the state of the art of measurement methods and standards for facilitating robust comparisons between diverse hardware and software environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy demand science for a decarbonized society in the context of the residential sector

To develop a decarbonized society, two contradictory requirements must be met: (1) reducing energy demand and (2) creating flexibility in energy demand in order to respond to fluctuations in renewable electricity generation. To help meet these requirements, conventional energy efficiency studies should be extended to incorporate “energy demand science.” This paper presents a definition of “energy demand science” and then reviews the related history and research questions of energy demand science in the context of the residential sector. It then examines three key areas that must be integrated into the next-generation energy demand science: (1) energy demand measurement with detailed granularity and analysis using cutting-edge technology, (2) energy demand modeling that helps clarify the formation mechanism of energy demand, and (3) identification of the factors that influence people's decision making, which represents typical human-dimension research. Energy demand science consists of technical, human, natural environment, demographic, and land-use dimensions, and their integration is key for the establishment of a decarbonized society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Dispatch Schedule Generation for Demand Flexibility Measures

This supplemental document describes the methodology used for determining the dispatch timing of various EUSS demand flexibility measures. Demand flexibility measures are designed to reduce/dispatch electricity demand in buildings during especially beneficial/critical times. The method used in this work utilizes predictions of building loads to generate a schedule that reflects the periods when the building's daily peak load occurs to support decision making in demand flexibility measures. The dispatch schedule generation method described in this document creates an hourly schedule that includes a load dispatch (peak) window for each day for a whole year based on load prediction, with options using different prediction methods: perfect prediction, bin-sampling method, fixed schedule, and outdoor air temperature (OAT)-based prediction method. The perfect prediction method performs a simulation to obtain the annual load profile as predicted load, representing the scenario of perfect load prediction. The bin-sampling method (1) categorizes days into representative bins by temperature characteristics, (2) performs simulations on sample days from each of those bins to create representative (or predicted) load, and (3) assigns representative loads for all days in a year based on the bin categorization. The fixed schedule method defines uniform start and end time of peak window with assumed fixed daily peak time, for all days in a season or a year. The OAT-based prediction method uses the statistics of OAT (minimum and maximum) as the indicators of peak load, with specified delay response time from building loads to temperature. Given the load prediction, daily peak periods are determined as a time window with specified length in each day that include the predicted daily peak load and with a secondary rule such as maximizing energy saving potential. The dispatch schedule generation method is not a standalone measure and is intended to be combined with other demand flexibility measures that could leverage the peak schedule and apply demand controls on specific systems or devices for demand response, such as measures described in "Measure Documentation - Thermostat Control for Load Shedding" and "Measure Documentation - Thermostat Control for Load Shifting".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The ionospheres of Mars and Venus

Observations made by spacecraft in the Mariner and Venera series have provided considerable knowledge of the structure of the ionospheres and atmospheres of Mars and Venus. This paper begins with brief but complete discussions of these measurements and their interpretations. The principles for constructing models of ionospheres are presented from the standpoint of mass, momentum, and energy conservation. The relevant ion chemistry is presented, and the meaning and use of plasma scale heights are discussed. The models discussed are the model of Cloutier and co-workers; the models of Banks and Axford, of Whitten, and of Herman and co-workers; the model developed by McElroy and Strobel to account for the nighttime ionosphere of Venus; and the models developed by a number of investigators for the thermal structure of the Martian and Venusian ionospheres.

Whitten, R. C.↗

Measurement of the branching fraction of Ξ c 0 → Λ c + π - at Belle

Based on a data sample of 983 fb -1 collected with the Belle detector at the KEKB asymmetric-energy e + ⁢e - collider, we present the study of the heavy-flavor-conserving decay Ξ$^{0}_{c}$ → Λ$^{+}_{c}$⁢π - with Λ$^{+}_{c}$ reconstructed via its p⁢K - π + decay mode. The branching fraction ratio $\mathscr{B}$⁡(Ξ$^{0}_{c}$ → Λ$^{+}_{c}$⁢π - )/$\mathscr{B}$⁡(Ξ$^{0}_{c}$ → Ξ - π + ) is measured to be 0.38 ±0.04 ±0.04. Combining with the world average value of $\mathscr{B}$(Ξ$^{0}_{c}$ → Ξ - π + ), the branching fraction $\mathscr{B}$⁡(Ξ$^{0}_{c}$ → Λ$^{+}_{c}$⁢π - ) is deduced to be (0.54 ±0.05 ±0.05 ±0.12)%. Here, the uncertainties above are statistical, systematic, and from $\mathscr{B}$⁡(Ξ$^{0}_{c}$ → Ξ - π + ), respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrating Health and Energy Efficiency in Healthcare Facilities

This report presents a review of literature and current best practices along the intersection of energy efficiency and occupant health at U.S. healthcare facilities, including federally owned buildings. It also includes a review of minimum code requirements for healthcare indoor environmental quality (IEQ) and research on building measures that optimize occupant health and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗