Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distributed Wind Hybrid Energy Systems for Rural Applications

Distributed-wind-based hybrid energy systems can smooth the power output from renewable energy resources. The number of these systems is growing because of their ability to contribute to local energy and resilience needs. Distributed wind hybrid systems offer major benefits for industrial loads, including enhanced energy reliability, cost efficiency, and sustainability. This fact sheet describes those benefits and considerations in detail.

14 SOLAR ENERGY↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Effect of bond thickness on fracture and fatigue strength of adhesively bonded composite joints

An experimental investigation of composite to composite bonded joints was undertaken to study the effect of bond thickness on debond growth rate under cyclic loading and critical strain energy release rate under static loading. Double cantilever beam specimens of graphite/epoxy adherends bonded with EC 3445 were tested under mode I loading. A different behavior of fracture and fatigue strength was observed with variation of bondline thickness.

Mall, S.↗

System for energy harvesting and/or generation, storage, and delivery

A device and method for harvesting, generating, storing, and delivering energy to a load, particularly for remote or inaccessible applications. The device preferably comprises one or more energy sources, at least one supercapacitor, at least one rechargeable battery, and a controller. The charging of the energy storage devices and the delivery of power to the load is preferably dynamically varied to maximize efficiency. A low power consumption charge pump circuit is preferably employed to collect power from low power energy sources while also enabling the delivery of higher voltage power to the load. The charging voltage is preferably programmable, enabling one device to be used for a wide range of specific applications.

Trainor, John T.↗

System for energy harvesting and/or generation, storage, and delivery

A device and method for harvesting, generating, storing, and delivering energy to a load, particularly for remote or inaccessible applications. The device preferably comprises one or more energy sources, at least one supercapacitor, at least one rechargeable battery, and a controller. The charging of the energy storage devices and the delivery of power to the load is preferably dynamically varied to maximize efficiency. A low power consumption charge pump circuit is preferably employed to collect power from low power energy sources while also enabling the delivery of higher voltage power to the load. The charging voltage is preferably programmable, enabling one device to be used for a wide range of specific applications.

Trainor, John T.↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

Electrochemical Nutrient Recovery for the Food–Energy–Water Nexus at Municipal Wastewater Facilities: Multivariate Analyses of Seasonal Sampling and Reactor Performance

Digester-equipped municipal wastewater facilities generate recycle streams with high nutrient loads that increase energy consumption and can cause environmental pollution. The reduction of these loads through electrochemical nutrient recovery (ENR) could enhance the food–energy–water nexus by producing fertilizer (struvite). This study investigated the recovery process through a 1 year sampling of recycle streams and the implementation of nutrient recovery. Time series analyses showed that P (as orthophosphate) concentration was time-variant in digester effluent streams, while N (as ammonia) concentration was time-variant in only the aerobic system. Furthermore, these two nutrient concentrations did not correlate in any of the recycle streams. Subsequent multivariate screening analyses identified anode type, NH 4 + concentration, cathodic potential, P concentration, and temperature as most significant for ENR. Finally, the optimum conditions of cathodic potential, anode area-to-volume ratio, and temperature applied to a real recycle stream resulted in 95% P recovery with 0.03 kWh/kg P. This energy consumption is significantly lower than process energy for conventional P fertilizers (1.1 kWh/kg P) and chemical recovery processes at scale (1.7–12.9 kWh/kg P). Overall, this study recommended specific process controls for nutrient recovery, expanded the variables evaluated for ENR, and demonstrated the ability to significantly impact energy demand associated with P-based fertilizers.

36 MATERIALS SCIENCE↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Test and Finite Element Analysis for Two Full-Scale Helicopter Crash Tests

Finite element analyses have been performed for two full-scale crash tests of an MD-500 helicopter. The first crash test was conducted to evaluate the performance of a composite deployable energy absorber under combined flight loads. In the second crash test, the energy absorber was removed to establish the baseline loads. The use of an energy absorbing device reduced the impact acceleration levels by a factor of three. Accelerations and kinematic data collected from the crash tests were compared to analytical results. Details of the full-scale crash tests and development of the system-integrated finite element model are briefly described along with direct comparisons of acceleration magnitudes and durations for the first full-scale crash test. Because load levels were significantly different between tests, models developed for the purposes of predicting the overall system response with external energy absorbers were not adequate under more severe conditions seen in the second crash test. Relative error comparisons were inadequate to guide model calibration. A newly developed model calibration approach that includes uncertainty estimation, parameter sensitivity, impact shape orthogonality, and numerical optimization was used for the second full-scale crash test. The calibrated parameter set reduced 2-norm prediction error by 51% but did not improve impact shape orthogonality.

Annett, Martin S.↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Development of 2 underseat energy absorbers for application to crashworthy passenger seats for general aviation aircraft

This report presents the methodology and results of a program conducted to develop two underseat energy absorber (E/A) concepts for application to nonadjustable crashworthy passenger seats for general aviation aircraft. One concept utilizes an inflated air bag, and the other, a convoluted sheet metal bellows. Prototypes of both were designed, built, and tested. Both concepts demonstrated the necessary features of an energy absorber (load-limiter); however, the air bag concept is particularly encouraging because of its light weight. Several seat frame concepts also were investigated as a means of resisting longitudinal and lateral loads and of guiding the primary vertical stroke of the underseat energy absorber. Further development of a seat system design using the underseat energy absorbers is recommended because they provide greatly enhanced crash survivability as compared with existing general aviation aircraft seats.

Warrick, J. C.↗

Structural load control during construction

The topics are presented in viewgraph form and include the following: examples of high transient loadings on large space structures; energy absorbing/load limiting strut research objectives; scope of research on energy absorbing struts to date; energy characteristics of cantilevered trusses with a tip load; ten bay long resilient truss example; stored energy characteristics of one meter deep truss; energy absorbing potential for 10-bay 5-meter deep truss; schematic of energy absorbing strut; linear load and motion control actuator; rigid body response of a solar array to the shuttle thruster pressure impingement; solar array piecewise linear response; solar array characteristics; solar array tip deflection and required actuator stroke; solar array response from finite element analysis; 12 bay energy absorbing test bed dynamics; and new AERO-Lab with 12-bay test beam.

Mikulas, Martin↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗