Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Recovery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Potential performance and challenges of an energy recovery linac upgrade to the Advanced Photon Source.

The Advanced Photon Source (APS) is a third-generation synchrotron radiation source operating at 7 GeV that has been in operation for over 10 years. In that time, the emittance has been improved from 8 to 3.1 nm, which is close to the practical minimum. Recently, APS undertook an intensive exploration of potential upgrades, including options for a replacement storage ring or Energy Recovery Linac (ERL) injector. Our conclusion was that only the ERL would provide a dramatically new capability. This paper discusses the potential performance available from an ERL upgrade to the APS and reviews the challenges of delivering this performance.

43 PARTICLE ACCELERATORS↗

Design of a Microbunched Electron Cooler Energy Recovery Linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics↗

Design of a microbunched electron cooler energy recovery linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics↗

Design of a Microbunched Electron Cooler Energy Recovery Linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55\,MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1\,nC, an average current of 100\,mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Deitrick, K. [Thomas Jefferson National Accelerato↗

Energy Recovery Linac: Controls System

This paper examines the equipment and software from which the controls system interface for the Energy Recovery Linac (ERL) will be implemented at the Brookhaven National Laboratory.

43 PARTICLE ACCELERATORS↗

Utah FORGE 4-2492: Design and Implementation of Innovative Stimulation Treatments to Maximize Energy Recovery - 2024 Annual Workshop Presentation

This is a presentation on the Design and Implementation of Innovative Stimulation Treatments to Maximize Energy Recovery Efficiency by The University of Texas at Austin, presented by Mukul M. Sharma. This video slide presentation discusses the following objectives: (1) to place fractures uniformly in a horizontal well to ensure a uniform distribution of flow into the fractures; (2) to maximize the area of the created fracture; (3) to ensure connectivity of the created fracture network; and (4) to ensure fracture size is optimized. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 14, 2024.

15 GEOTHERMAL ENERGY↗

Material and energy recovery in integrated waste management systems: An innovative approach for the characterization of the gaseous emissions from residual MSW bio-drying

In the sector of residual municipal solid waste management an increasing attention is put towards the role of biological treatments like bio-drying and bio-stabilization in order to decrease the need of landfilling volumes. The literature shows a lack of information concerning the emission factor of pollutants released from these processes. The available data are generally spot characterizations of concentration and air flow-rate that are used together in order to assess the emission factors. This approach caused significant differences among the available data as the release of pollutants is not steady. This paper belongs to a group of six papers concerning a research on material and energy recovery in integrated waste management systems, developed by a network of five universities. The contribution of the University of Trento, focuses on the bio-drying process with the following targets: (a) developing an innovative low cost method of sampling/measurement able to take into account the dynamics of release of pollutants; (b) checking the efficiency of a bio-filter; (c) verifying the variability of generation of some pollutants; (d) generating emission factors. The research was developed using a bio-drying pilot plant. As a treatment of the process air, the bio-reactor was coupled with a bio-filter. The emissions were characterized using an original approach based on the adoption of two measurement chambers suitable for hosting passive samplers. The passive samplers allowed the characterization of VOCs, N{sub 2}O, NH{sub 3} and H{sub 2}S. A bio-chemical model, useful for energy and mass balances, supported the interpretation of the presented bio-drying run.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimising energy recovery and use of chemicals, resources and materials in modern waste-to-energy plants

Highlights: • WtE plants are to be optimized beyond current acceptance levels. • Emission and consumption data before and after 5 technical improvements are discussed. • Plant performance can be increased without introduction of new techniques or re-design. • Diagnostic skills and a thorough understanding of processes and operation are essential. - Abstract: Due to ongoing developments in the EU waste policy, Waste-to-Energy (WtE) plants are to be optimized beyond current acceptance levels. In this paper, a non-exhaustive overview of advanced technical improvements is presented and illustrated with facts and figures from state-of-the-art combustion plants for municipal solid waste (MSW). Some of the data included originate from regular WtE plant operation – before and after optimisation – as well as from defined plant-scale research. Aspects of energy efficiency and (re-)use of chemicals, resources and materials are discussed and support, in light of best available techniques (BAT), the idea that WtE plant performance still can be improved significantly, without direct need for expensive techniques, tools or re-design. In first instance, diagnostic skills and a thorough understanding of processes and operations allow for reclaiming the silent optimisation potential.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Evaluation of Energy Recovery Ventilators

Over the years, building scientists have characterized the relationship between building airtightness, exhaust-only appliances airflows, and building depressurization. Now, as the use of deep retrofit measures and new construction practices is growing to realize lower infiltration levels in increasingly tighter envelopes, performance issues can arise with the operation of exhaust-only appliances in a depressurized home. As the depressurization levels climb in tighter homes, many of these exhaust-only appliances see their rated airflows reduced and other related performance issues arise as a result. If sufficiently depressurized, atmospherically vented combustion appliances that may be present in the home can backdraft as well. Furthermore, when exhaust-only appliances operate and the tight home becomes depressurized, water vapor intrusion from outdoors can raise additional issues of mold in the building envelope in more humid climates. The use of energy recovery ventilators (ERVs) in tight homes in mixed-humid and hot-humid climates is already practiced. Unbalancing the ERV by reducing exhaust airflows can provide a means to supply makeup air and reduce the level of home depressurization to mitigate these issues, helping to realize the rated performance of the exhaust-only appliances, achieve safe operation of atmospherically vented combustion, provide the necessary level of fresh ventilation air, and/or improve envelope durability. The unbalanced operation of the ERV to address depressurization can obviously result in unintended consequences in other areas, such as further loss of humidity control in homes in more humid climates. In such tight home scenarios, it is expected that ERVs will operate a substantial amount of time in unbalanced mode with much higher supply than exhaust airflows. Although ERV design performance under balanced flow conditions is well documented, there is no information in the public domain that empirically establishes the effect of unbalanced flow on sensible and latent exchange, especially in the now dominant membrane-type ERV used in residential applications. Therefore, in this task, Gas Technology Institute (GTI) focused on a laboratory evaluation of the unbalanced flow (lowered exhaust airflow) performance of the RenewAire model EV 200, membrane-type ERV delivering 200 standard cubic feet per minute (SCFM) of supply air. The conducted tests show significant variation in ERV effectiveness at different levels of unbalanced air flows. Keeping supply airflow constant and lowering exhaust airflow increases effectiveness of both latent and sensible heat exchange. However, the increased effectiveness is accompanied by reduced capacity for load removal from the supply air, resulting in increased load to the conditioned space. Under decreasing exhaust airflow conditions, sensible load effectiveness exceeded a value of 1 at two sets of testing conditions. This was a result of the temperature rise of the supply air passing through the ERV augmented by the effect of motor heat gain, cross leakage heat gain, and casing heat gain. Consequently, measured sensible effectiveness must be qualified as the so-called Apparent Sensible Effectiveness of the ERV unit (the term used in the Canadian Standards Association C439 standard for testing ERVs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Greenhouse gas emissions from MSW incineration in China: Impacts of waste characteristics and energy recovery

Determination of the amount of greenhouse gas (GHG) emitted during municipal solid waste incineration (MSWI) is complex because both contributions and savings of GHGs exist in the process. To identify the critical factors influencing GHG emissions from MSWI in China, a GHG accounting model was established and applied to six Chinese cities located in different regions. The results showed that MSWI in most of the cities was the source of GHGs, with emissions of 25-207 kg CO{sub 2}-eq t{sup -1} rw. Within all process stages, the emission of fossil CO{sub 2} from the combustion of MSW was the main contributor (111-254 kg CO{sub 2}-eq t{sup -1} rw), while the substitution of electricity reduced the GHG emissions by 150-247 kg CO{sub 2}-eq t{sup -1} rw. By affecting the fossil carbon content and the lower heating value of the waste, the contents of plastic and food waste in the MSW were the critical factors influencing GHG emissions of MSWI. Decreasing food waste content in MSW by half will significantly reduce the GHG emissions from MSWI, and such a reduction will convert MSWI in Urumqi and Tianjin from GHG sources to GHG sinks. Comparison of the GHG emissions in the six Chinese cities with those in European countries revealed that higher energy recovery efficiency in Europe induced much greater reductions in GHG emissions. Recovering the excess heat after generation of electricity would be a good measure to convert MSWI in all the six cities evaluated herein into sinks of GHGs.

54 ENVIRONMENTAL SCIENCES↗

Study of Optical Frequency Chirping and Pulse Compression in a High-Gain Energy-Recovery-Linac-Based Free-Electron Laser

In this paper we report a direct experimental investigation of optical frequency chirping effects induced by ultrashort electron bunches in a high-gain energy-recovery-linac (ERL) free-electron laser (FEL) cavity. Our measurement and analysis shows clear evolution of the optical pulse chirp verses the electron bunch energy chirp. Further study also provides important evidence that under certain conditions much shorter FEL pulses can be obtained through properly chirping electron bunches and optical pulse compression. Although studies about the chirp measurement on Self-amplified-spontaneous-emission (SASE) FEL were reported recently, we believe this paper for the first time provides a comprehensive and close observation into the very unique temporal and spectral characteristics of ultrashort optical pulses from a high-gain ERL FEL. This is made possible by the stable operation and unique capability of the Jefferson Lab machine to change the electron bunch energy chirp with no curvature. Preliminary simulations will also be presented.

Zhang, Shukui↗

Study of Optical Frequency Chirping and Pulse Compression in a High-Gain Energy-Recovery-Linac-Based Free-Electron Laser

In this paper we report a direct experimental investigation of optical frequency chirping effects induced by ultrashort electron bunches in a high-gain energy-recovery-linac (ERL) free-electron laser (FEL) cavity. Our measurement and analysis shows clear evolution of the optical pulse chirp verses the electron bunch energy chirp. Further study also provides important evidence that under certain conditions much shorter FEL pulses can be obtained through properly chirping electron bunches and optical pulse compression. Although studies about the chirp measurement on Self-amplified-spontaneous-emission (SASE) FEL were reported recently, we believe this paper for the first time provides a comprehensive and close observation into the very unique temporal and spectral characteristics of ultrashort optical pulses from a high-gain ERL FEL. This is made possible by the stable operation and unique capability of the Jefferson Lab machine to change the electron bunch energy chirp with no curvature. Preliminary simulations will also be presented.

Zhang, Shukui↗

EUV FEL light source based on energy recovery linac with on-orbit laser plasma injection

We report on a week-long study of a conceptual design of EUV FEL light source based on an energy recovery linac with on-orbit laser plasma accelerator injection scheme. We carried out this study during USPAS Summer 2023 session of Unifying Physics of Accelerators, Lasers and Plasma applying the art of inventiveness TRIZ. An ultrashort Ti-sapphire laser accelerates electron beams from a gas target with mean energy of 20 MeV, which are then ramped up to 1 GeV in a five-turn scheme with a series of fixed field alternating magnets and two superconducting RF cavities (100 MeV per cavity per turn). The electron beam is then bypassed to an undulator line optimized to generate EUV light of 13.5 nm at kW level in a single pass.

43 PARTICLE ACCELERATORS↗

Transverse BBU Suppression with Feedback for Energy-Recovery Linacs

The Electron–Ion Collider (EIC) achieves its design luminosity by cooling the ion beam with a high-current electron beam generated in an energy-recovery linac (ERL). The baseline ERL lattice employs a BNL five-cell cavity that is frequency-scaled to 197 MHz, 591 MHz, and 1.773 GHz, raising concerns about multibunch beam-breakup (BBU) instabilities. Threshold currents for each frequency option are established with two independent BBU tracking codes, providing cross-validated operating margins that guide cavity selection. To further increase the current limit, we incorporate a digital transverse feedback (FB) system that targets the dominant higher-order modes (HOMs). Simulations show the FB raises the BBU threshold by roughly an order of magnitude: power-spectral-density analysis of the beam centroid at the linac exit confirms strong suppression of the aliased HOM peak, although some spectral growth appears at secondary frequencies. This combined study quantifies baseline BBU limits, demonstrates effective active mitigation, and charts a practical path toward robust, high-current operation of the EIC ERL.

Accelerator Physics↗

Design Concept of A γ-γ Collider-Based Higgs Factory Driven by a Thin Laser Target and Energy Recovery Linacs

A γ-γ collider has long been considered an option for a Higgs Factory. Such photon colliders usually rely on Compton back-scattering for generating high energy γ photons and further Higgs bosons through γ-γ collisions. The presently existing proposals or design concepts all have chosen a very thick laser target (i.e., high laser photon intensity) for Compton scatterings. In this paper, we present a new design concept of a γ-γ collider utilizing a thin laser target (i.e., relatively low photon density), thus leading to a low electron to γ photon conversion rate. This new concept eliminates most useless and harmful soft γ photons from multiple Compton scattering so the detector background is improved. It also greatly relaxes the requirement of the high peak power of the laser, a significant technical challenge. A high luminosity for such a γ-γ collider can be achieved through an increase of the bunch repetition rate and current of the driven electron beam. Further, a multi-pass recirculating linac could greatly reduce the linac cost and energy recovery is required to reduce the needed RF power.

43 PARTICLE ACCELERATORS↗

Design Concept of a Gamma-gamma Higgs Factory Driven by Thin Laser Targets and Energy Recovery Linacs

A gamma-gamma collider has long been considered an option for a Higgs Factory. Such photon colliders usually rely on Compton back-scattering for generating high energy gamma photons and further Higgs bosons through gamma-gamma collisions. The presently existing proposals or design concepts all have chosen a very thick laser target (i.e., high laser photon intensity) for Compton scatterings. In this paper, we present a new design concept of a gamma-gamma collider utilizing a thin laser target (i.e., relatively low photon density), thus leading to a low electron to gamma photon conversion rate. This new concept eliminates most useless and harmful low energy soft gamma photons from multiple Compton scattering so the detector background is improved. It also greatly relaxes the requirement of the high peak power of the laser, a significant technical challenge. A high luminosity for such a gamma-gamma collider can be achieved through an increase of the bunch repetition rate and current of the driven electron beam. Further, multi-pass recirculating linac could greatly reduce the linac cost and energy recovery is required to reduce the needed RF power.

43 PARTICLE ACCELERATORS↗