Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Usage Reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Final ACT configuration evaluation

The Final ACT Configuration Evaluation Task of the Integrated Application of Active Controls (IAAC) technology project within the energy efficient transport program is summarized. The Final ACT Configuration, through application of Active Controls Technology (ACT) in combination with increased wing span, exhibits significant performance improvements over the conventional baseline configuration. At the design range for these configurations, 3590 km, the block fuel used is 10% less for the Final ACT Configuration, with significant reductions in fuel usage at all operational ranges. Results of this improved fuel usage and additional system and airframe costs and the complexity required to achieve it were analyzed to determine its economic effects. For a 926 km mission, the incremental return on investment is nearly 25% at 1980 fuel prices. For longer range missions or increased fuel prices, the return is greater. The technical risks encountered in the Final ACT Configuration design and the research and development effort required to reduce these risks to levels acceptable for commercial airplane design are identified.

Source record↗

In-Use Fleet Evaluation of Fast-Charge Battery Electric Transit Buses

With support from the U.S. Department of Energy's Vehicle Technologies Office, the National Renewable Energy Laboratory (NREL) conducts real-world performance evaluations of advanced medium- and heavy-duty fleet vehicles. Evaluation results can help vehicle manufacturers fine-tune their designs and assist fleet managers in selecting fuel-efficient, low-emission vehicles that meet their economic and operational goals. In 2015, NREL launched an in-service evaluation of 12 battery electric buses (BEBs) compared to conventional compressed natural gas (CNG) buses operated by Foothill Transit in West Covina, California. The study aims to improve understanding of the overall usage and effectiveness of fast-charge BEBs and associated charging infrastructure in transit operation. To date, NREL researchers have analyzed more than 148,000 km of in-use operational data, including driving and charging events. Foothill Transit purchased the BEBs with grant funding from the Federal Transit Administration's Transit Investments for Greenhouse Gas and Energy Reduction Program.

33 ADVANCED PROPULSION SYSTEMS↗

Decentralised optimisation of cogeneration in virtual power plants

Within several projects we investigated grid structures and management strategies for active grids with high penetration of renewable energy resources and distributed generation (RES and DG). Those ''smart grids'' should be designed and managed by model based methods, which are elaborated within these projects. Cogeneration plants (CHP) can reduce the greenhouse gas emissions by locally producing heat and electricity. The integration of thermal storage devices is suitable to get more flexibility for the cogeneration operation. If several power plants are bound to centrally managed clusters, it is called ''virtual power plant''. To operate smart grids optimally, new optimisation and model reduction techniques are necessary to get rid with the complexity. There is a great potential for the optimised management of CHPs, which is not yet used. Due to the fact that electrical and thermal demands do not occur simultaneously, a thermally driven CHP cannot supply electrical peak loads when needed. With the usage of thermal storage systems it is possible to decouple electric and thermal production. We developed an optimisation method based on mixed integer linear programming (MILP) for the management of local heat supply systems with CHPs, heating boilers and thermal storages. The algorithm allows the production of thermal and electric energy with a maximal benefit. In addition to fuel and maintenance costs it is assumed that the produced electricity of the CHP is sold at dynamic prices. This developed optimisation algorithm was used for an existing local heat system with 5 CHP units of the same type. An analysis of the potential showed that about 10% increase in benefit is possible compared to a typical thermally driven CHP system under current German boundary conditions. The quality of the optimisation result depends on an accurate prognosis of the thermal load which is realised with an empiric formula fitted with measured data by a multiple regression method. The key functionality of a virtual power plant is to increase the value of the produced power by clustering different plants. The first step of the optimisation concerns the local operation of the individual power generator, the second step is to calculate the contribution to the virtual power plant. With small extensions the suggested MILP algorithm can be used for an overall EEX (European Energy Exchange) optimised management of clustered CHP systems in form of the virtual power plant. This algorithm has been used to control cogeneration plants within a distribution grid. (author)

20 FOSSIL-FUELED POWER PLANTS↗

Modeling the Impacts of Solar Distributed Generation on U.S. Water Resources

Distributed electric power generation technologies typically use little or no water per unit of electrical energy produced; in particular, renewable energy sources such as solar PV systems do not require cooling systems and present an opportunity to reduce water usage for power generation. Within the US, the fuel mix used for power generation varies regionally, and certain areas use more water for power generation than others. The need to reduce water usage for power generation is even more urgent in view of climate change uncertainties. In this paper, we present an example case within the state of Tennessee, one of the top four states in water consumption for power generation and one of the states with little or no potential for developing centralized renewable energy generations. The potential for developing PV generation within Knox County, Tennessee, is studied, along with the potential for reducing water withdrawal and consumption within the Tennessee Valley stream region. Electric power generation plants in the region are quantified for their electricity production and expected water withdrawal and consumption over one year, where electrical generation data is provided over one year and water usage is modeled based on the cooling system(s) in use. Potential solar PV electrical production is modeled based on LiDAR data and weather data for the same year. Our proposed methodology can be summarized as follows: First, the potential solar generation is compared against the local grid demand. Next, electrical generation reductions are specified that would result in a given reduction in water withdrawal and a given reduction in water consumption, and compared with the current water withdrawal and consumption rates for the existing fuel mix. The increase in solar PV development that would produce an equivalent amount of power, is determined. In this way, we consider how targeted local actions may affect the larger stream region through thoughtful energy development. This model can be applied to other regions, other types of distributed generation, and used as a framework for modeling alternative growth scenarios in power production capacity in addition to modeling adjustments to existing capacity.

distributed energy generation↗

Distributed Cross-Channel Hierarchical Aggregation for Foundation Models

Vision-based scientific foundation models hold significant promise for advancing scientific discovery and innovation. This potential stems from their ability to aggregate images from diverse sources—such as varying physical groundings or data acquisition systems—and to learn spatio-temporal correlations using transformer architectures. However, tokenizing and aggregating images can be compute-intensive, a challenge not fully addressed by current distributed methods. In this work, we introduce the Distributed Cross-Channel Hierarchical Aggregation (D-CHAG) approach designed for datasets with a large number of channels across image modalities. Our method is compatible with any model-parallel strategy and any type of vision transformer architecture, significantly improving computational efficiency. We evaluated D-CHAG on hyperspectral imaging and weather forecasting tasks. When integrated with tensor parallelism and model sharding, our approach achieved up to a 75% reduction in memory usage and more than doubled sustained throughput on up to 1,024 AMD GPUs on the Frontier Supercomputer.

Tsaris, Aristeidis (aris) [ORNL] (ORCID:0000000277↗

Conceptual Feasibility Study of the Hyperloop Vehicle for Next-Generation Transport

The Hyperloop concept is proposed as a faster, cheaper alternative to high-speed rail and traditional short-haul aircraft. It consists of a passenger pod traveling through a tube under light vacuum while being propelled and levitated by a combination of permanent and electro-magnets. The concept addresses NASA's research thrusts for growth in demand, sustainability, and technology convergence for high-speed transport. Hyperloop is a radical departure from other advanced aviation concepts, however it remains an aeronautics concept that tackles the same strategic goals of low-carbon propulsion and ultra-effcient vehicles. System feasibility was investigated by building a multidisciplinary vehicle sizing model that takes into account aerodynamic, thermodynamic, structures, electromagnetic, weight, and mission analyses. The sizing process emphasized the strong coupling between the two largest systems: the tube and the passenger pod. The model was then exercised to examine Hyperloop from a technical and cost perspective. The structural sizing analysis of the travel tube demonstrates potential for signi cant capital cost reductions by considering an underwater route. Examination of varying passenger capacity indicates that the system can be operated with a wide range of passenger loads without significant change in operating expenses. Lastly, a high-level sizing study simulated variations in tube area, pressure, pod speed, and passenger capacity showing that there is a tube pressure that minimizes operating energy usage. The value of this optimal tube pressure is highly sensitive to numerous design details. These combined estimates of energy consumption, passenger throughput, and mission analyses all support Hyperloop as a faster and cheaper alternative to short-haul flights. The tools and expertise used to quantify these results also demonstrate how traditional aerospace design methods can be leveraged to handle the complex and coupled design process. Much of the technology development required for the Hyperloop is shared with next-generation aircraft. Furthermore, the substantial public interest and active commercial development make it an ideal candidate as an aircraft technology driver and test bed.

Hyperloop Vehicle↗

Pathway to Decarbonization Through Industrial Energy Efficiency: Micro and Macro Perspectives from Compressed Air Usage

Abstract Energy audits directly provided the industrial sector with reduced energy costs and avoided emissions. Still, they also lead to far-reaching indirect and induced local, regional, and national benefits. This paper aims to present the techno-economic-environmental analysis to achieve decarbonization through implementing industrial energy efficiency at micro and macro levels. An integrated techno-economic-environmental methodology is developed. Case studies of micro-level carbon reduction efforts through industrial energy efficiency technologies are presented. The broader macroeconomic and environmental effects of technology on society are analyzed using data from 206 energy audits of industrial compressed air systems conducted over 13 years. The impacts show that energy-efficient improvements lead to direct cost savings for manufacturers, boost economic activity across sectors, and affect carbon dioxide emissions both short-term and long-term in the region. Given their extensive benefits, energy audits significantly influence policymaking. We devised a methodology to link micro-level energy audit data with macroeconomic and environmental analyses to quantify these cascading benefits. The economic scenario analysis shows that $228 M has been saved from direct industrial energy savings from implementing all compressed air recommendations in the studied periods and the region. In addition, the investment made through manufacturers would create 2,025 jobs and $383 M annually, cascading regional economic impacts. The environmental analysis shows that the regional manufacturers have directly avoided about 2.8 M metric tons of carbon dioxide emissions.

Engineering↗

Plug Load Management System Field Study

In 2018, NREL performed a demonstration of the IBIS InteliNetwork(TM) plug load management system, which includes: intelligent socket devices, which plug into existing electrical outlets and collect energy usage information; a gateway, which manages communication between the intelligent sockets and the PLM cloud service; and a PLM network, which is a cloud-based measurement and control network for the entire system. Two retail stores served as the field study sites. The PLM system was found to be effective at reducing plug load energy use, with a projected annual plug load reduction of 11% and 18% at the test locations. Retail staff reported that the hardware was easy to use, but no one used the online data management system, intended to analyze and control the hardware. This PLM solution shows promise as an effective means to monitor, control, and reduce plug load energy use, but the economics of the system need to be improved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending cost–benefit analysis for the sustainability impact of inter-urban Intelligent Transport Systems

The paper reports research involving three cost–benefit analyses performed on different ITS schemes (Active Traffic Management, Intelligent Speed Adaptation and the Automated Highway System) on one of the UK's busiest highways — the M42. The environmental scope of the assets involved is widened to take into account the possibility of new technology linked by ICT and located within multiple spatial regions. The areas focused on in the study were data centre energy emissions, the embedded emissions of the road-side infrastructure, vehicle tailpipe emissions, additional hardware required by the vehicles (if applicable) and safety, and all aspects of sustainability. Dual discounting is applied which aims to provide a separate discount rate for environmental elements. For ATM, despite the energy costs of the data centre, the initial implementation costs and mitigation costs of its embedded emissions, a high cost–benefit ratio of 5.89 is achieved, although the scheme becomes less effective later on its lifecycle due to rising costs of energy. ISA and AHS generate a negative result, mainly due to the cost of getting the vehicle on the road. In order to negate these costs, the pricing of the vehicle should be scaled depending upon the technology that is outfitted. Retrofitting on vehicles without the technology should be paid for by the driver. ATM will offset greenhouse gas emissions by 99 kt of CO{sub 2} equivalency over a 25 year lifespan. This reduction has taken into account the expected improvement in vehicle technology. AHS is anticipated to save 280 kt of CO{sub 2} equivalency over 15 years of operational usage. However, this offset is largely dependent on assumptions such as the level of market penetration. - Highlights: • Three cost–benefit analyses are applied to inter-urban intelligent transport. • For ATM, a high cost–benefit ratio of 5.89 is achieved. • ATM offsets greenhouse gas emissions by 99 kt of CO{sub 2} equivalency over 25 years. • ISA and AHS generate a negative result due to vehicle implementation costs. • AHS is anticipated to save 280 kt of CO{sub 2} equivalency over 15 years.

54 ENVIRONMENTAL SCIENCES↗

Port of New York and New Jersey Drayage Electrification Analysis

The National Renewable Energy Laboratory (NREL) evaluated the potential for drayage electrification in the Port of New York and New Jersey (PoNYNJ), with a focus on operators: Harbor Freight Transport (HF), Safeway Trucking (SWT), and International Motor Freight Inc (IMF). This report summarizes the data collection and electrification evaluation of all three drayage operators, includes detailed operational data, and identifies the performance requirements for battery electric tractors (BETs) and corresponding infrastructure operated within the context of PoNYNJ drayage operation. This report also details a methodology to evaluate opportunities, strategies, and challenges associated with future expansions of BETs in meeting PANYNJ emissions goals. The Port Authority has established a goal of achieving Net Zero carbon emissions by 2050 across all facilities, including from tenant and stakeholder sources such as drayage trucks. NREL used real-world performance data collected on the three PoNYNJ drayage operations, along with modeling and analysis tools to compare BET to diesel trucks. From March to July 2021, NREL collected 1Hz vehicle and engine data from 46 drayage trucks at the three operators totaling nearly 121,000 miles of operation, providing enough information to assess vehicle operations for electrification potential. A Future Automotive Systems Technology Simulator (FASTSim) electric truck powertrain model was validated using PoNYNJ data and scenarios were run to evaluate drayage truck electrification requirements over the real-world cycles. The first scenario examined BET viability with minimal changes to existing operations. This assumes the trucks charge when stopped for two hours or longer, have a functional battery size of 375 kWh, and can charge at 270 kilowatts (kW) average which are the specification of the commercially available Freightliner eCascadia. The second scenario looked at what operational, charging infrastructure, and BET technology changes would be needed to fully electrify. Finally, detailed analysis was run on charging rate structure to understand operational costs to the fleets. The studied drayage trucks averaged 5.1 MPG, spent roughly 9% of their energy at idle, and drove an average of 140 miles per day with a maximum daily distance of 573 miles. The FASTSim model results indicate a comparable BET would use 417 kWh of energy per day on average accounting for cargo weight, which is close to the full usable capacity of the eCascadia currently available on the market. Based on the daily average operating data, partial fleet electrification is possible with current technology. However, some specific days of operation would require over 1,600 kWh of energy due to longer distances traveled by the trucks and more intense operation. Trucks used for long distance and intense operation cannot be readily electrified with current technology without operational changes. Full adoption of BETs could reduce CO 2 emissions from these fleets by roughly 75% today, eliminating 76 metric tons of CO 2 (MTCO 2 ) per vehicle each year, which equates to 24,100 MTCO 2 per year for all three operators. Commercially available direct current fast chargers (DCFC) have charge rates up to 350 kW. Based on the average daily modeled energy use for each operator, current industrial rate structures, and the assumption of 350 kW peak charging, full drayage electrification would increase electricity consumption. In addition, peak demand usage would increase with unmanaged charging along with cost of electricity having a direct impact on cost per mile for electric vehicles. The resulting cost per mile for BETs along with comparable cost per mile for conventional diesel trucks are also examined at $\$$4.00 per gallon of diesel. It will be important for PANYNJ and the drayage operators within the PoNYNJ to consider these load impacts to their existing electrical infrastructure and devise operational strategies that avoid coincident charging of vehicles to mitigate demand charges. Despite these electricity cost increases, savings from reductions in diesel consumption will help offset the costs of this increased electricity consumption. However, prices of both electricity and diesel are subject to change based on various factors meaning the realized savings will vary over time. This shows BETs could be cost-competitive on an energy cost per mile basis for all scenarios while diesel is above $\$$3.00/gal. Further, if diesel prices dropped to the 15-year low of $2.33/gal, it would still be cost competitive to operate the EVs with electricity costs of 16.3 ¢/kWh or less.

33 ADVANCED PROPULSION SYSTEMS↗

Dynamic pricing for residential electric customers: a ratepayer advocate's perspective

New Jersey's Rate Counsel urges that the consideration of alternative pricing mechanisms aimed at encouraging a reduction or shift in residential electricity usage include recognition of the needs and wishes of consumers. Without consumer buy-in, any such pricing mechanisms will fail. To achieve the desired goals, customers must be able to understand and react to the pricing signals. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

The long term energy problem and aeronautics

The projected increase in energy consumption by transportation in general and civil aviation in particular is directly opposed to the dwindling supplies of natural petroleum crude oil currently used to produce aircraft fuels. This fact dictates the need to develop even more energy conservative aircraft and propulsion systems than are currently available and to explore the potential of alternative fuels to replace the current petroleum derived hydrocarbons. Advances in technology are described in the areas of improved component efficiency, aircraft and engine integration, control systems, and advanced lightweight materials that are needed to maximize performance and minimize fuel usage. Also, improved turbofan and unconventional engine cycles which can provide significant fuel usage reductions are described. These advancements must be accomplished within expected environmental constraints such as noise and pollution limits. Alternative fuels derived from oil shale and coal are described, and the possible technological advancements needed to use these fuels in aircraft engines are discussed and evaluated with relation to potential differences in fuel characteristics.

Rudey, R. A.↗

Modeling of GE Appliances: Final Presentation

The Energy Information Administration (EIA) estimates that electricity use will increase by more than 30 percent by 2035, and that residential electricity usage will increase by 23 percent. During this time, peak electricity demand is expected grow at an even greater rate, requiring significant investment in system capacity. In addition, increased penetration of intermittent renewable resources will increase system variability, requiring additional resources to mitigate the variability associated with generator output. Widespread adoption of demand response (DR) enabled appliances, thermostats, and other demand-side resources can result in significant reduction to peak electrical demand and provide potential grid stabilization benefits. The key to adoption is to provide this resource at a cost commensurate with traditional grid capabilities, and to appropriately share both the costs and the benefits between the consumer and the service provider (i.e., the utility). However, the business model for investing in demand-side resources cannot be determined without an estimation of the possible technical benefits and how those benefits translate to monetary value in current electrical market structures. GE Appliances has developed a line of appliances that will have the capability of offering several levels of demand reduction actions based on information received from the utility grid, often in the form of price or grid status. However due to a number of factors, including the number of DR-enabled appliances available at any given time, the reduction of diversity factor due to the synchronizing control signal, and the percentage of consumers who may override the utility signal, it can be difficult to predict the aggregate response of a large number of residences. The effects of these behaviors have been modeled and simulated in the Pacific Northwest National Laboratory (PNNL) developed open-source software, GridLAB-D™, including evaluation of appliance controls, improvement to current algorithms, and development of aggregate control methodologies. The results of these simulations provide an estimation of the possible technical benefits (e.g., peak load reduction) attributable to smart appliances, but do not describe the monetary value of these services. This report is the final in a series of three reports funded by U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) in collaboration with GE Appliances’ through a Cooperative Research and Development Agreement (CRADA) to describe the potential of GE Appliances’ DR-enabled appliances to provide benefits to the utility grid.

Demand Response↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock: Preprint

20% of the U.S. commercial building sector's energy usage is from on-site combustion of fossil fuels for heating. Decarbonization will require electrification of these systems to meet climate goals, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for decarbonization solutions. However, there is limited understanding of the impact on emissions that considers regional electricity generation methods, as well as the impact of other heat pump intricacies such as the effects of temperature on capacity/efficiency, defrost operation, realistic sizing methodologies, and supplementary heating. This study explores the effects of transitioning all conventional RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock, DOE's calibrated model of the U.S. commercial building stock developed by NREL. Results show 9% and 17% reductions in stock aggregate energy consumption and GHG emissions, respectively. Furthermore, average heat pump operational details are presented by state. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building electrification↗

TH-CD-202-02: A Preliminary Study Evaluating Beam-Hardening Artifact Reduction On CT Direct Electron-Density Images

Purpose: A prototype reconstruction algorithm that can provide direct electron density (ED) images from single energy CT scans is being currently developed by Siemens Healthcare GmbH. This feature can eliminate the need for kV specific calibration curve for radiation treatemnt planning. An added benefit is that beam-hardening artifacts are also reduced on direct-ED images due to the underlying material decomposition. This study is to quantitatively analyze the reduction of beam-hardening artifacts on direct-ED images and suggest additional clinical usages. Methods: HU and direct-ED images were reconstructed on a head phantom scanned on a Siemens Definition AS CT scanner at five tube potentials of 70kV, 80kV, 100kV, 120kV and 140kV respectively. From these images, mean, standard deviation (SD), and local NPS were calculated for regions of interest (ROI) of same locations and sizes. A complete analysis of beam-hardening artifact reduction and image quality improvement was conducted. Results: Along with the increase of tube potentials, ROI means and SDs decrease on both HU and direct-ED images. The mean value differences between HU and direct-ED images are up to 8% with absolute value of 2.9. Compared to that on HU images, the SDs are lower on direct-ED images, and the differences are up to 26%. Interestingly, the local NPS calculated from direct-ED images shows consistent values in the low spatial frequency domain for images acquired from all tube potential settings, while varied dramatically on HU images. This also confirms the beam -hardening artifact reduction on ED images. Conclusions: The low SDs on direct-ED images and relative consistent NPS values in the low spatial frequency domain indicate a reduction of beam-hardening artifacts. The direct-ED image has the potential to assist in more accurate organ contouring, and is a better fit for the desired purpose of CT simulations for radiotherapy.

60 APPLIED LIFE SCIENCES↗

HiFiPDV2 v. 2

SAND2024-01061O The HiFiPDV-2 software is similar to other photonic Doppler velocimetry (PDV) analysis codes in that it converts signals from intensity-time space to frequency-time space using a short-time Fourier transform (STFT). It then analyzes peaks of the resulting power spectral density information to extract the velocity-time history. The unique aspects of HiFiPDV and HiFiPDV-2 are that this reduction process is repeated for an array of reasonable STFT input variables. The resulting population distribution of output velocity-time histories is evaluated to determine the most likely velocity history and its associated uncertainty. This uncertainty is defined as the systematic uncertainty of the PDV signal as it is a function of input values to the reduction process. The HiFiPDV-2 program brings new functionality and efficiency to these calculations—most notably significant reductions in memory usage and calculation times, the ability to evaluate frequency-shifted signals, and the ability to filter out baseline signals. Developers recommend that users have at least 2 GB of RAM per CPU core in their system. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Voorhees, Travis↗

Using Electric Vehicles to Meet Balancing Requirements Associated with Wind Power

Many states are deploying renewable generation sources at a significant rate to meet renewable portfolio standards. As part of this drive to meet renewable generation levels, significant additions of wind generation are planned. Due to the highly variable nature of wind generation, significant energy imbalances on the power system can be created and need to be handled. This report examines the impact on the Northwest Power Pool (NWPP) region for a 2019 expected wind scenario. One method for mitigating these imbalances is to utilize plug-in hybrid electric vehicles (PHEVs) or battery electric vehicles (BEVs) as assets to the grid. PHEVs and BEVs have the potential to meet this demand through both charging and discharging strategies. This report explores the usage of two different charging schemes: V2GHalf and V2GFull. In V2GHalf, PHEV/BEV charging is varied to absorb the additional imbalance from the wind generation, but never feeds power back into the grid. This scenario is highly desirable to automotive manufacturers, who harbor great concerns about battery warranty if vehicle-to-grid discharging is allowed. The second strategy, V2GFull, varies not only the charging of the vehicle battery, but also can vary the discharging of the battery back into the power grid. This scenario is currently less desirable to automotive manufacturers, but provides an additional resource benefit to PHEV/BEVs in meeting the additional imbalance imposed by wind. Key findings in the report relate to the PHEV/BEV population required to meet the additional imbalance when comparing V2GHalf to V2GFull populations, and when comparing home-only-charging and work-and-home-charging scenarios. Utilizing V2GFull strategies over V2GHalf resulted in a nearly 33% reduction in the number of vehicles required. This reduction indicates fewer vehicles are needed to meet the unhandled energy, but they would utilize discharging of the vehicle battery into the grid. This practice currently results in the voiding of automotive manufacturer's battery warranty, and is not feasible for many customers. The second key finding is the change in the required population when PHEV/BEV charging is available at both home and work. Allowing 10% of the vehicle population access to work charging resulted in nearly 80% of the grid benefit. Home-only charging requires, at best, 94% of the current NWPP light duty vehicle fleet to be a PHEV or BEV. With the introduction of full work charging availability, only 8% of the NWPP light duty vehicle fleet is required. Work charging has primarily been associated with mitigating range anxiety in new electric vehicle owners, but these studies indicate they have significant potential for improving grid reliability. The V2GHalf and V2GFull charging strategies of the report utilize grid frequency as an indication of the imbalance requirements. The introduction of public charging stations, as well as the potential for PHEV/BEVs to be used as a resource for renewable generation integration, creates conditions for additional products into the ancillary services market. In the United Kingdom, such a capability would be bid as a frequency product in the ancillary services market. Such a market could create the need for larger, third-party aggregators or services to manage the use of electric vehicles as a grid resource. Ultimately, customer adoption, usage patterns and habits, and feedback from the power and automotive industries will drive the need.

17 WIND ENERGY↗