Search NASA⌕ Search

SEARCH · Search NASA

Results for “Engineering - Other instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Comparisons of Rig and Engine Dynamic Events in the Compressor of an Axi-Centrifugal Turboshaft Engine

Steady state and dynamic data were acquired in a T55-L-712 compressor rig. In addition, a T55-L-12 engine was instrumented and similar data were acquired. Rig and engine stall/surge data were analyzed using modal techniques. This paper compares rig and engine preliminary results for the ground idle (approximately 60% of design speed) point. The results of these analyses indicate both rig and engine dynamic event are preceded by indications of traveling wave energy in front of the compressor face. For both rig and engine, the traveling wave energy contains broad band energy with some prominent narrow peaks and, while the events are similar in many ways, some noticeable differences exist between the results of the analyses of rig data and engine data.

Owen, A. Karl↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Cyber-Informed Engineering for Nuclear Reactor Digital Instrumentation and Control

As nuclear reactors transition from analog to digital technology, the benefits of enhanced operational capabilities and improved efficiencies are potentially offset by cyber risks. Cyber-Informed Engineering (CIE) is an approach that can be used by engineers and staff to characterize and reduce new cyber risks in digital instrumentation and control systems. CIE provides guidance that can be applied throughout the entire systems engineering lifecycle, from conceptual design to decommissioning. In addition to outlining the use of CIE in nuclear reactor applications, this chapter provides a brief primer on nuclear reactor instrumentation and control and the associated cyber risks in existing light water reactors as well as the digital technology that will likely be used in future reactor designs and applications.

42 ENGINEERING↗

Limerick Safety-Related Instrumentation and Control Upgrade Human Factors Engineering Preliminary Validation Report

This document is a results summary report for the human factors engineering (HFE) preliminary validation (PV) performed for the Limerick Generating Station (LGS) Safety-Related (SR) Instrumentation and Control (I&C) Upgrade Project at the Idaho National Laboratory (INL) Human Systems Simulation Laboratory (HSSL). This occurred during the week of February 20, 2023.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Research pressure instrumentation for NASA Space Shuttle main engine, modification no. 5

Research concerning the development of pressure instrumentation for the space shuttle main engine is reported. The following specific topics were addressed: (1) transducer design and materials, (2) silicon piezoresistor characterization at cryogenic temperatures, (3) chip mounting characterization, and (4) frequency response optimization.

Anderson, P. J.↗

Rapid Development of Instrument Thermal Models: Perspectives and Guidelines from NASA Goddard’s Instrument Design Laboratory

- The design and development of robotic spaceflight instruments is a critical part of NASA’s vision to discover and expand knowledge for the benefit of humanity - For typical flight instrument projects, thermal engineers will develop initial instrument thermal models over weeks or months, then iterate them over a project’s lifespan – In each iteration, the engineer will: - Refine their thermal models and thermal designs in accordance with updates from other subsystems - Perform trade studies - Solve very detailed and complex analysis problems, including worst-cases and contingencies - Pick hardware and plan for testing and integration - However, prior to a project being established, or for proposal development at an early conceptual stage, the luxury of multiple instrument design iterations may be limited or nonexistent – Within a short timeline, how do you complete a thermal model or explore multiple possible instrument configurations? – What are the critical parameters for your model? Which details do you include or leave out?

Kan Yang↗

Multiphysics modeling of printed surface acoustic wave thermometers

Surface acoustic wave (SAW) transducers are a class of sensors and actuators that operate on the fundamental principle of piezoelectricity. Aerosol jet printing and other additive manufacturing techniques have resulted in the low-cost fabrication of low-power and small-footprint SAW devices that are suitable for sensing in high-temperature and radioactive environments. In this work, we developed a series of temperature-dependent finite element models for a SAW transducer consisting of printed silver interdigitated transducers (IDTs) deposited onto piezoelectric lithium niobate. Modeling accuracy was evaluated experimentally from room temperature to 200 °C using an aerosol-jet-printed SAW thermometer. A time-domain study enabled visualization of the wave propagation and successfully guided the denoising of the scattering parameter measurement. Additionally, frequency-domain models using traditional modal analysis or the unique port boundary condition feature in COMSOL Multiphysics accurately predicted the temperature-driven natural frequency drift in the SAW thermometer. The finite element models developed in this study serve to facilitate the computer-aided design of future SAW transducers for applications in harsh environments.

47 OTHER INSTRUMENTATION↗

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

Locating Partial Discharges in Power Transformers with Convolutional Iterative Filtering

The most common source of transformer failure is in the insulation, and the most prevalent warning signal for insulation weakness is partial discharge (PD). Locating the positions of these partial discharges would help repair the transformer to prevent failures. This work investigates algorithms that could be deployed to locate the position of a PD event using data from ultra-high frequency (UHF) sensors inside the transformer. These algorithms typically proceed in two steps: first determining the signal arrival time, and then locating the position based on time differences. This paper reviews available methods for each task and then propose new algorithms: a convolutional iterative filter with thresholding (CIFT) to determine the signal arrival time and a reference table of travel times to resolve the source location. The effectiveness of these algorithms are tested with a set of laboratory-triggered PD events and two sets of simulated PD events inside transformers in production use. Tests show the new approach provides more accurate locations than the best-known data analysis algorithms, and the difference is particularly large, 3.7X, when the signal sources are far from sensors.

47 OTHER INSTRUMENTATION↗

Low frequency noise in a quiet, clean, general aviation turbofan engine

A quiet, clean, general aviation, turbofan engine was instrumented to measure the fluctuating pressures in the combustor, turbine exit duct, engine nozzle and the far field. Both a separate flow nozzle and an internal mixer nozzle were tested. The fluctuating pressure data are presented in overall pressure and power levels and in spectral plots. The combustor data are compared to recent theory and found to be in excellent agreement. The results indicate that microphone correction procedures for elevated mean pressures are questionable. Ordinary coherence function analysis suggests the presence of an additional low frequency noise source downstream of the turbine that is due to the turbine itself. Low frequency narrowband data and coherence function analysis are presented.

Huff, R. G.↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Threshold Helium Leakage Detection Switch with Ultra Low Power Operation

Detecting helium leakage is important in many applications, such as in dry cask nuclear waste storage systems. This work develops a helium detection system based on the relative permittivity (dielectric constant) difference between air and helium. This difference changes the status of an electrostatic microelectromechanical system (MEMS) switch. The switch is a capacitive-based device and requires a very negligible amount of power. Exciting the switch’s electrical resonance enhances the MEMS switch sensitivity to detect low helium concentration. This work simulates two different MEMS switch configurations: a cantilever-based MEMS modeled as a single-degree-freedom model and a clamped-clamped beam MEMS molded using the COMSOL Multiphysics finite-element software. While both configurations demonstrate the switch’s simple operation concept, the clamped-clamped beam was selected for detailed parametric characterization due to its comprehensive modeling approach. The beam detects at least 5% helium concentration levels when excited at 3.8 MHz, near electrical resonance. The switch performance decreases at lower excitation frequencies or increases the circuit resistance. The MEMS sensor detection level was relatively immune to beam thickness and parasitic capacitance changes. However, higher parasitic capacitance increases the switch’s susceptibility to errors, fluctuations, and uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent Progress in Modulated Photothermal Radiometry

In this review, the emerging work using a technique known as modulated photothermal radiometry (MPTR) is evaluated. As MPTR has matured, the previous discussions on theory and modeling have become increasingly limited in their applicability to the current state of the art. After a brief history of the technique, the currently used thermodynamic theory is explained, highlighting the commonly applied simplifications. The validity of the simplifications is explored via modeling. Various experimental designs are compared, and the differences are explored. New applications, as well as emerging analysis techniques, are presented to emphasize the trajectory of MPTR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-Efficient Neuromorphic Architectures for Nuclear Radiation Detection Applications

A comprehensive analysis and simulation of two memristor-based neuromorphic architectures for nuclear radiation detection is presented. Both scalable architectures retrofit a locally competitive algorithm to solve overcomplete sparse approximation problems by harnessing memristor crossbar execution of vector–matrix multiplications. The proposed systems demonstrate excellent accuracy and throughput while consuming minimal energy for radionuclide detection. To ensure that the simulation results of our proposed hardware are realistic, the memristor parameters are chosen from our own fabricated memristor devices. Based on these results, we conclude that memristor-based computing is the preeminent technology for a radiation detection platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗