Pressure Distribution Induced on a Flat Plate at a Free-Stream Mach Number of 1.39 by Rockets Exhausting Upstream and Downstream

An experimental investigation was made of the pressures induced on a flat plate at a free-stream Mach number of 1.39 by a supersonic rocket jet exhausting upstream and downstream. Measurements of the pressure distribution on a flat plate were made at zero angle of attack for 11 different locations of the jet exhaust nozzle beneath the wing. Measurements were made at ratios of rocket-exit total pressure to freestream static pressure from 6 to 60 and at a Reynolds number per foot of approximately 10 x 10 6 . The rocket when exhausted upstream produced a strong shock that moved further upstream with increasing rocket-exit total-pressure ratio. Positive incremental normal-force coefficients were obtained at all test positions. Data at 11 test positions are tabulated for rocket-on and rocket-off pressure coefficients as well as for incremental pressure coefficients for the 48 orifices of the flat plate for the range of ratio of rocket-exit total pressure to free-stream static pressure of the investigation. Changing the location of the model with respect to the plate had a negligible effect when the rocket was varied in the chordwise direction, but the pressure coefficients were reduced as the rocket was lowered away from the flat-plate wing.

Supersonic jet↗

The Measurement of Fuel-air Ratio by Analysis of the Oxidized Exhaust Gas

An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy Fuel Specification, No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs or the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124

FUELS-TOLUENE↗

Testing Installed Propulsion for Shielded Exhaust Configurations

Jet-surface interaction (JSI) can be a significant factor in the exhaust noise of installed propulsion systems. Tests to further the understanding and prediction of the acoustic impacts of JSI have been described. While there were many objectives for the test, the overall objective was to prepare for a future test validating the design of a low-noise, lowboom supersonic commercial airliner. In this paper we explore design requirements for a partial aircraft model to be used in subscale acoustic testing, especially focusing on the amount of aircraft body that must be included to produce the acoustic environment between propulsion exhaust system and observer. We document the dual-stream jets, both nozzle and flow conditions, which were tested to extend JSI acoustic modeling from simple singlestream jets to realistic dual-stream exhaust nozzles. Sample observations are provided of changes to far-field sound as surface geometry and flow conditions were varied. Initial measurements are presented for integrating the propulsion on the airframe for a supersonic airliner with simulated airframe geometries and nozzles. Acoustic impacts of installation were modest, resulting in variations of less than 3 EPNdB in most configurations.

engine airframe integration↗

Testing Installed Propulsion For Shielded Exhaust Configurations

Jet-surface interaction (JSI) can be a significant factor in the exhaust noise of installed propulsion. Tests to further understanding and prediction of the acoustic impacts of JSI have been described. While there were many objectives for the NASA JSI1044 test, the overall objective was to prepare for a 2016 test validating the design of a low-noise, low-boom supersonic commercial airliner. In this paper we explore design requirements for a partial aircraft model to be used in subscale acoustic testing, especially focusing on the amount of shielding surface that must be provided to simulate the acoustic environment between propulsion exhaust system and observer. We document the dual-stream jets, both nozzle and flow conditions, which were tested to extend JSI acoustic modeling from simple single-stream jets to realistic dual-stream exhaust nozzles. Examples of observations found as surface geometry and flow conditions were varied were provided. And we have presented initial measurements of the installation impacts of integrating the propulsion on the airframe for a supersonic airliner with realistic airframe geometries and nozzles.

engine airframe integration↗

Demonstration of Super-X divertor exhaust control for transient heat load management in compact fusion reactors

Nuclear fusion could offer clean, abundant energy. However, managing the power exhausted from the core fusion plasma towards the reactor wall remains a major challenge. This is compounded in emerging compact reactor designs promising more cost-effective pathways towards commercial fusion energy. Alternative Divertor Configurations (ADCs) are a potential solution. In this work, we demonstrate exhaust control in ADCs, employing a novel method to diagnose the neutral gas buffer, which shields the target. Our work on the Mega Ampere Spherical Tokamak Upgrade shows that ADCs tackle key risks and uncertainties for fusion energy. Their highly reduced sensitivity to perturbations enables active exhaust control in otherwise unfeasible situations and facilitates an increased passive absorption of transients, which would otherwise damage the divertor. We observe a strong decoupling of each divertor from other reactor regions, enabling near-independent control of the divertors and core plasma. Our work showcases the real-world benefits of ADCs for effective heat load management in fusion power reactors.

Imaging techniques↗

First field test of a novel optical gas analyser in the exhaust of Wendelstein 7-X

A novel optical gas analyser, designed for isotope-resolved exhaust composition measurement, was field-tested at Wendelstein 7-X (W7-X) to validate its laboratory-proven concept under operational fusion experiment conditions. The system, Optix, comprises a cold cathode remote plasma generator and a high-resolution Fabry–Perot spectrometer and was deployed in the exhaust line of W7-X during the OP2.3 campaign. The injection of 3 He and 4 He for minority ion-cyclotron heating provided a test case for helium isotope discrimination. Despite limitations due to background gas and low partial pressures of the target species, isotope-resolved spectral signatures were successfully observed, demonstrating the fundamental viability of the Optix approach. Additionally, the spectrometer was evaluated for plasma emission measurements from both core and edge sightlines. While helium line emission was detectable, interpretation was hindered by complex background signals, highlighting the benefits of controlled remote plasma generators for spectroscopy. This first deployment provides critical insight into pressure requirements, spectral resolution, and operational constraints, informing future applications of optical exhaust diagnostics in fusion devices.

magnetic confinement fusion↗

Co-Optimization Scheme for Hybrid Electric Vehicles Powertrain and Exhaust Emission Control System Using Future Speed Prediction

Hybrid electric vehicles (HEVs) have been an effective solution for improved vehicle fuel efficiency and reduced emission pollution. In this paper, a co-optimization scheme is proposed to optimize fuel efficiency for HEVs. Here, the proposed optimization scheme uses obtainable future speed prediction as the basis to optimally tune control parameters for the existing powertrain control system. The ramp-up time of the catalyst temperature to reach its light-off level in the exhaust emission system is also considered as an additional optimization constraint to reduce emission. The Toyota Prius Hybrid Simulink model which is an integrated model for a powertrain and exhaust emission system is validated using real data from several real driving cycle scenarios. Then, to simplify the formulation of the proposed algorithm, the model for the optimization for powertrain and exhaust emission systems is represented by a set of equivalent neural network (NN) models learned using the data generated from the well-validated Toyota Prius Hybrid Simulink model. Using NN models, a co-optimization algorithm is established that provides an optimal tuning of some fuel-sensitive powertrain control parameters using future speed prediction, leading to a novel co-optimization algorithm, achieving on average a further 9.22% fuel savings for the Toyota Prius Hybrid Simulink model.

33 ADVANCED PROPULSION SYSTEMS↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multiscale Modeling of Corrosion and Oxidation Performance and Their Impact on High-temperature Fatigue of Automotive Exhaust Manifold Components

The persistent need to reducing automobile emissions has led to the wide adoption of turbocharger technology and engine downsizing, which results in a substantial raise in exhaust temperature, reaching as high as 950°C. Therefore, the material selection for exhaust manifolds and turbocharger housings becomes significantly challenging. The successful development of the multiscale models on oxidation and corrosion performance, and their impact on high-temperature fatigue will enable the acceleration of new, high-performance, heat-resistant alloy solutions and the reduction of time and cost in achieving a durable design. In this project, we developed and validated multiscale models that can accurately predict the corrosion and oxidation performance and their impact on high-temperature fatigue of high-temperature automotive exhaust manifold components. The capability of accurately predicting the corrosion/oxidation-fatigue damage can significantly reduce the time and cost of achieving a durable design. The models were used to guide the development of new high thermomechanical fatigue (TMF) performance alloys.

Li, Mei↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Bifunctional Pt/CeO 2 -Cu 1 /CeO 2 Catalyst System for Isooctane Oxidation under Fully Simulated Engine-Exhaust Condition: Eliminating the Inhibition by CO

Pt-based catalysts, because of their outstanding activity for hydrocarbon oxidation, are widely used in the engine-exhaust aftertreatment system to remove hydrocarbon emissions. However, the CO and NO x present in real engine exhausts compete with hydrocarbons for active Pt sites, and thus inhibit hydrocarbon oxidation. In this work, we evaluated the inhibition effects of CO and NO on isooctane oxidation over a Pt/CeO 2 catalyst under the simulated condition of the US DRIVE test protocol (S-GDI, stoichiometric gasoline direct injection). We also leveraged a low-cost single-atom Cu 1 /CeO 2 catalyst, which is highly active for low-temperature CO oxidation, to eliminate the inhibition effect of CO. Specifically, by physically mixing Cu 1 /CeO 2 and Pt/CeO 2 , all the CO is completely converted below 200 °C under simulated exhaust condition, which helps lower the isooctane oxidation temperature. However, the unconverted NO still strongly suppresses HC oxidation. Possible strategies to address the NO inhibitor were proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probe samples components of rocket engine exhaust

Water-cooled, cantilevered probe samples the exhaust plume of rocket engines to recover particles for examination. The probe withstands the stresses of a rocket exhaust plume environment for a sufficient period to obtain a useful sample of the exhaust components.

Schumacher, P. E.↗

Exhaust cloud rise and diffusion in the atmosphere

Analytical approach develops physical-mathematical model of rocket engine exhaust cloud rise, growth, and diffusion. Analytic derivations and resultant model apply to hot exhaust cloud study or industrial stack plumes, making work results applicable to air pollution. Model formulations apply to all exhaust cloud types and various atmospheric conditions.

Chandler, M. W.↗

Nozzle exhaust plume backscatter experiment using the JPL Molsink facility

Qualitative tests were made by injecting water through a rocket nozzle wall, and the droplet trajectories were observed photographically. These tests were conducted for nozzles in which boundary layer flow is significant. The tests indicated that both gases and particulate matter will be found in the region outside of the plume boundaries, and can be calculated using current analytical techniques. A test program is being conducted to measure the distribution of exhaust gases from small nozzles using an electron beam/photomultiplier system and a matrix of quartz crystal microbalances. Calibration tests, using simulated hydrazine exhaust product gas mixtures, were also conducted. The test program and results of the pumping calibration tests with hydrazine (simulated hydrazine exhaust products) are reported.

Simon, W.↗

The geometry and physical properties of exhaust clouds generated during the static firing of S-1C and S-2 rocket engines

An experimental program was conducted during the static firing of the S-1C stage 13, 14, and 15 rocket engines and the S-2 stage 13, 14, and 15 rocket engines. The data compiled during the experimental program consisted of photographic recordings of the time-dependent growth and diffusion of the exhaust clouds, the collection of meteorological data in the ambient atmosphere, and the acquisition of data on the physical structure of the exhaust clouds which were obtained by flying instrumented aircraft through the clouds. A new technique was developed to verify the previous measurements of evaporation and entrainment of blast deflector cooling water into the cloud. The results of the experimental program indicate that at the lower altitudes the rocket exhaust cloud or plume closely resembles a free-jet type of flow. At the upper altitudes, where the cloud is approaching an equilibrium condition, structure is very similar to a natural cumulus cloud.

Forbes, R. E.↗