Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exhaust”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Engine Valve Materials for Next Generation Higher Efficiency Engines

The growing demand to increase the performance and efficiency of light-, medium-, and heavy-duty engines continues to drive increases in combustion intensities and cylinder pressures, which result in higher exhaust gas temperatures. Thus, there is a critical need for new materials that can meet the performance and cost targets for components such as exhaust valves which are exposed to these higher exhaust gas temperatures. Oak Ridge National Laboratory (ORNL) has developed several lower-cost, high-strength alloys that have the potential to be adopted into intake and/or exhaust valves in the next generation, high-efficiency engines and other high temperature applications. These alloys are covered by two issued patents: 1. G. Muralidharan, U. S. Patent No. 9,605,565 B2, “Low-cost Fe--Ni--Cr alloys for high temperature valve applications,” March 28, 2017. 2. G. Muralidharan, U. S. Patent 9,752, 468 B2, “Low-Cost, High-Strength Fe-Ni-Cr Alloys for High Temperature Exhaust Valve Applications, Issued Sep. 5, 2017. The overall scope of this CRADA project was for Oak Ridge National Laboratory to collaborate with Tenneco Powertrain to: 1) better define the properties required for intake and/or exhaust valves for next generation vehicles, 2) fabricate industrial scale heats of alloys down-selected from existing patents, 3) generate critical high temperature property data that will help evaluate the suitability of these new alloys for high temperature intake and/or exhaust valves, and finally to 4) fabricate and evaluate the performance of prototype intake/and or exhaust valves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sampling probe

A system for sampling a surface includes a sampling probe including a housing with a probe end having a sampling fluid opening, a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling fluid opening. The sampling fluid exhaust conduit includes a wall, a sampling fluid exhaust conduit inlet opening for removing sampling fluid from the sampling fluid opening, and a sampling fluid exhaust conduit outlet opening for removing fluid from the sampling fluid exhaust conduit. A sampling fluid analytic conduit is also provided in the sampling probe and has a sampling fluid analytic conduit inlet opening spaced upstream from the sampling fluid exhaust conduit outlet opening, downstream from the sampling fluid exhaust conduit inlet opening, and from the wall of the sampling fluid exhaust conduit. A wash conduit can also be provided. Methods for sampling are also disclosed.

Van Berkel, Gary↗

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator↗

Gaseous contaminant transfer in membrane-based air-to-air energy exchangers

Membrane-based air-to-air energy exchangers (M–AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and air-conditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (ε-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.

42 ENGINEERING↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Control of hybrid boosting in highly diluted internal combustion engines

A novel hybrid system enabling both flexible supercharging and limited torque assist is studied to mitigate transient response challenges of a turbocharged spark ignition engine equipped with low pressure exhaust gas recirculation. The hybrid system, called a power split supercharger (SC), is configured with a planetary gear set that splits the supercharging power between a small low-voltage electric motor and the engine crankshaft. The air path controller relies on the coordination of four actuators on the engine side and three low-level actuators on the hybrid boosting device. A decentralized control scheme is used in this work, in which the master–slave structure of the boost pressure controller decreases the turbo-lag associated with exhaust gas recirculation, while minimizing the SC operation for fuel economy. A vector reference governor is used to prevent compressor surge during engine tip-outs. In addition, the desired intake manifold pressure is modified to provide time for evacuating the exhaust gas recirculation and avoiding misfires when transitioning to low load, while the hybrid capability of the power split SC is used to recuperate the unwanted generated power. All controllers are validated on both a mean value engine model and a high-fidelity engine model. Practical challenges of implementing the vector reference governor to the highly nonlinear engine air path with pressure pulsations originating from the engine reciprocation are discussed and some solutions are proposed.

Engineering↗

Supercritical Reforming of Wet Ethanol for High Efficiency Direct-injection Heavy-duty Compression-ignition Engines

The purpose of the research was to investigate the potential of using a mature bio-fuel in heavy-duty compression ignition engines. By co-optimizing both the fuel characteristics and engine system the potential for a superior outcome was demonstrated. The use of wet bio-ethanol eliminates the majority of the energy intensive distilling and dehydrating fuel production processes, which moves the fuel towards carbon neutral and also lowers the fuel costs. The relatively high water content of the resulting fuel is leveraged in the proposed novel combustion system by incorporating an integrated high efficiency exhaust waste heat recovery system. This results in significantly higher thermal efficiency. In addition the combustion system features low criteria pollutant emissions and the potential to reduce the initial cost of the engine system hardware. Substantial societal benefits are demonstrated through the co-optimization of the fuel and engine system. A computational proof-of-concept study has been performed to demonstrate the potential benefits of a novel wet ethanol heavy-duty compression ignition combustion system featuring integrated exhaust waste heat recovery. A combined in-cylinder closed cycle 3D computational fluid dynamics (CFD) - 1D engine system simulation approach was used. The models were validated to baseline engine data using diesel fuel and then applied to the wet ethanol study. The original concept was to maximize exhaust waste heat recovery through supercritical reforming of the wet ethanol fuel. Phase I simulation results indicated that the optimal solution for maximum engine efficiency gains were realized through maximizing thermo-mechanical recuperation with negligible fuel reformation. The results show the potential to achieve impressive gains in brake thermal efficiency (BTE) over the base diesel engine. The potential to increase BTE up to 20.9% over the base diesel engine was demonstrated, with even larger gains possible through reduced in-cylinder heat transfer losses. The majority of the efficiency gains were realized through integrated high efficiency exhaust waste heat recovery. The concept also has the potential to achieve future ultra-low NO x emissions standards and negligible engine-out soot emissions. The mixing controlled combustion of high temperature wet ethanol features relatively low engine-out NO x emissions without the need for exhaust gas recirculation (EGR). The soot free combustion enabled by the relatively high oxygen content of ethanol also allows for the use of stoichiometric mixing controlled combustion, which is not practical with diesel fuel. When stoichiometric combustion is used a simple passive 3-way catalyst can be used for exhaust emissions after-treatment and near zero tailpipe emissions. The Phase I simulations results have defined the system layout and requirements in preparation for the Phase II experimental proof-of-concept study. The potential applications of the research include most current applications of diesel engines. The Phase I study focused on heavy-duty on-highway class 8 trucks. However, virtually any application that requires highly efficient clean power generation would benefit from the novel engine system proposed. The results indicate substantial fuel cost savings and reduced greenhouse gas emissions with similar or reduced initial system hardware costs compared to modern diesel engine systems.

09 BIOMASS FUELS↗

Plasma Wall Interaction with 3-D Plasma Boundaries

The interaction of the edge plasma and the material surfaces is one of the most critical challenges on the path to harness fusion power as new, fundamental energy source. This challenge typically combines the thrust to reach high density, low temperature (detached) plasmas in front of the divertor target plates as well as understanding the plasma material interaction (PMI) in particular in this regime. The combination of both research thrusts represents an extraordinarily challenging subject encompassing spatial scales spanning nanometers to meters in all states of matter and across a broad energy range. Modeling capabilities, which help to interpret data from nowadays experiments and enable extrapolation to future devices are urgently required. This is in particular true for toroidal magnetic confinement devices with three-dimensional (3D) plasma boundaries. Such plasma boundary geometries occur in tokamaks, when small amplitude magnetic perturbations are used to stabilize the unruly edge plasma or in stellarators, that are inherently 3D plasma confinement devices. In this project, the impact of 3D plasma boundaries on the plasma material interaction (PMI) was assessed. This work focused on plasma boundary conditions, in which high-density conditions at the material surfaces yield mitigation of the otherwise immense heat and particle loads that these materials would see. These so-called high recycling and eventually detached plasma regimes are of great interest for future reactor operation. In the project, key features that are unique to 3D boundaries were explored in comparison to canonically assumed axisymmetric plasma edge situations in tokamaks. In particular, the relevance of the 3D boundary situation in the extrapolation to the plasma boundary solution at ITER, the next step fusion energy experiment under construction as a multi-national, world-wide large-science experiment in southern France, has been explored. The EMC3-EIRENE plasma edge fluid and kinetic neutral transport code has been advanced to cope with the challenging and unprecedented conditions in the ITER boundary plasma including 3D fields that are planned to be used to suppress harmful edge instabilities, the so-called edge localized modes. This is a vital integration challenge for ITER and the results from this grant have provide a leading capability for this assessment. It was shown that the detachment process in a 3D edge solution for ITER follows the recycling regimes that are known from axisymmetric solutions, but that multiple plasma exhaust channels connected to the material surfaces are established which feature individual recycling characteristics. Because these channels touch the material surfaces in the divertor in a 3D geometry, the compatibility with the plasma material interaction (PMI), including erosion and impurity generation has been found to be an important part of the integration challenge. To address this, the fully 3D plasma material interaction code ERO2 has been adapted to these ITER specific geometries and a homogeneous mixing model was implemented, that allows to consider the mixing of Be and Was used at ITER in the PMI modeling. This model enhancement has been used to study non-local migration of Be in the JET ITER like wall configuration and it has been shown that with this model such complex migration processes in ITER relevant plasma shapes and with ITER relevant plasma boundary conditions can be addressed. The combined modeling approach using EMC3-EIRENE as a plasma boundary transport code and the ERO2 specialized PMI model will be an asset for the continued preparations of ITER operation as well as for Fusion Pilot Plant efforts that have emerged in the U.S. during the evolution of this grant. The predictive capability of this numerical tool has been validated at the DIII-D US national fusion facility. Here, dedicated plasma edge diagnostics were implemented to measure the impurity household around a 3D edge plasma during ELM suppression by 3D fields. Dedicated experiments with local material probes using these diagnostics and the state-of-the-art suite of boundary measurements at DIII-D have shown that the 3D perturbation of the plasma edge that is excreted by such 3D control fields yield a perturbation of the plasma boundary flux structure and hence also of the resulting PMI. The 3D boundary plasma is composed out of helical magnetic flux channels that intersect the divertor targets at an angle relative to the main guiding field, i.e., the toroidal magnetic field component of the tokamak. A similar effect has been measured as well on limiter surfaces during the startup campaign at the new stellarator experiment Wendelstein 7-X. These experiments ad initial analysis with the ERO plasma material interaction model, suggested that the place of erosion for a given particle from the surface and its re-deposition can be different in such 3D field geometries yielding potentially a significant level of net-erosion. This is not the case for axisymmetric solutions, where it was shown in the past that the eroded particles are effectively re-deposited into gaps produced by erosion at the same position and hence the net-erosion levels are small. For ITER, the quest to suppress the ELMs and at the same time maintain the integrity of the divertor is an issue, which these fundamental findings will help to resolve. The coupling of this work to the extrapolation in the ITER program has been addressed by both the PI and the lead numerical scientist being ITER Science Fellows in the duration of the contract and forward. A second focus in the exploration of 3D boundary effects on tokamaks and stellarators has been set on the measurement of helium exhaust features with such 3D fields. This is important because He represents the ash of the fusion process and needs to be exhausted. It was shown that 3D field application compatible with suppression of ELMs yields an increase of the helium exhaust performance. The ratio of the effective helium confinement time over the energy confinement time was reduced by almost 50% which demonstrated that the impact of helium accumulation in the plasma core with respect to the confinement of energy to sustain the fusion reaction is significantly improved with such 3D control fields. It was shown that this is the case for tokamaks as well as stellarators. At the Large helical Device in Japan, a similar enhancement of the helium exhaust features when small amplitude additional 3D fields were applied was measured. This is an important additional function of 3D field application and its impact on ITER is presently being studied in combination with investigations of helium exhaust in 3D field geometries of stellarator devices.

3D plasma edge transport↗

Iodine Removal in the DFLAW Flow-Sheet

In support of the WTP project, off-gas system and regulatory testing has been conducted previously on the DM1200 pilot melter equipped with a prototypical off-gas system installed at The Catholic University of America’s Vitreous State Laboratory (VSL). During the regulatory tests, an AC-S test bed filled with Kombisorb BAT 37 was included in the prototypical off-gas system and evaluated for response to HLW and LAW exhaust streams. Offline testing and small-scale testing of that media were also conducted. Testing demonstrated that a temperature rise occurred in the activated carbon media when water vapor was first introduced to virgin Kombisorb BAT 37, in response to high nitrogen oxide concentrations, and in response to the presence of organic compounds. Conditioning of the test bed by gradually increasing the NOx concentration prior to the introduction of organics was found to be an important operational strategy for preventing larger temperature excursions. However, no mercury was present in the exhaust stream during DM1200 testing and therefore comparable test data for mercury removal efficiency or temperature response of the carbon media in the presence of mercury were not collected in the DM1200 tests. In view of the need for data on mercury removal performance, BNI contracted with Atkins and the VSL to install and operate a suitable test system at VSL to collect the required data. That testing was designed to assess the performance of Kombisorb BAT-37 and the guard bed material, Sofnolime RG, for simulated melter exhaust streams that contain the highest concentrations of mercury, nitrogen oxides, acid gases, and organic compounds expected in WTP LAW melter exhaust. During shakedown testing with the new system, however, it became evident that a number of issues with Sofnolime RG as the guard bed material would render it unsuitable for this application. BNI subsequently determined that the guard bed was redundant for removal of acid gases since they could be adequately removed by the SBS and WESP. However, since the guard bed material was also credited with significant iodine removal , there was a need for a replacement material that would adequately perform that role. BNI identified several candidate media but performance data in gas compositions that are representative of the WTP LAW off-gas were not available. Accordingly, there was a need to test and evaluate the performance of these candidate media prior to performing the originally-planned tests. To that end, small scale tests were conducted to assess the performance of various adsorbents in simulated melter exhaust streams that contain mercury, iodine, nitrogen oxides, acid gases, and acetonitrile, which are expected to be present in WTP LAW melter exhaust.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Airborne infectious disease isolation units and method of making using prefabricated containers

In one embodiment, a prefabricated container is modified as a medical isolation room by replacing an original door with a clear front door. An intake louver and an adjustable damper are disposed at a lower part of the front end. An exhaust vent is disposed at an upper part of the back wall. An exhaust fan and a HEPA filter are coupled to the exhaust vent. Washable coverings cover interior sides of the container to provide washable, nonslip interior surfaces. The exhaust fan and the adjustable damper at the intake louver are controlled to produce in the medical isolation room a negative air pressure of at least about minus 0.01 inch of water gage (approximately 2.5 pascals) and a displacement ventilation exhaust flow rate through the exhaust vent of at least about 100 cubic feet per minute (cfm) greater than an intake flow rate through the intake louver.

Channell, Michael G.↗

Low soot stoichiometric compression-ignition combustion

A combustion system including a combustion mechanism that injects oxygenated fuel into a combustion chamber. The oxygenated fuel mixes with the intake air in the combustion chamber where the air-fuel ratio in a portion of the combustion chamber is stoichiometric. The combustion mechanism includes an ignition mechanism that ignites the air-fuel mixture that generates a threshold number of particulates during combustion of the air-fuel mixture. The combustion system further includes an exhaust gas recirculation (EGR) device that recirculates a portion of the exhaust gases back into the combustion chamber. The EGR device recirculates the portion of the exhaust to lower combustion temperature resulting in reduced amount of nitrogen oxide in the exhaust. The combustion system further includes a three-way catalytic converter in line with the exhaust channel to convert a second portion of the exhaust gases, leading to lower pollutant emissions than conventional combustion systems.

Pickett, Lyle M.↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Mercury Speciation During Vitrification of LAW

n this work, laboratory and engineering-scale tests were conducted that mimic the reactive environment of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) low activity waste (LAW) melter and off-gas system in order to assess the speciation of mercury at select points in the processing system. The experimental protocols, test equipment, feed materials used, and rationale for testing are detailed in the Test Plan for this work. Particular attention was paid to the amount and speciation of mercury in submerged bed scrubber (SBS) solutions, which are intended to be recycled back to the melter feed at the WTP. Results are presented from detailed mercury analysis of these solutions using Environmental Protection Agency (EPA) Method 1630 and modifications to this method for dimethyl mercury and methyl mercury as well as EPA Method 1631 and modifications to this method for total, dissolved, elemental, suspended, and ionic mercury. Testing was conducted in two separate sets of experiments: (1) One set of tests (crucible-scale furnace tests) that involved heating small batches of mercury-spiked melter feed in crucibles to determine the amount of mercury retained in the glass and the species of mercury in the exhaust gases; (2) A second set of tests (DM10 melter tests) was planned that involved creating LAW melter plenum gas compositions using the DM10 melter system, injecting mercury into the off-gas stream, and passing that stream though a reactor that simulates various plenum gas conditions. Operational issues led to the need to use one of the VSL DM100 melters in place of the planned DM10 melter for these tests. The speciation of mercury after exposure to those conditions was monitored. In both sets of tests, the exhaust gases were run through a scrubber that was intended to mimic the LAW SBS in order to determine how much of the mercury exiting the melter would be retained in the primary off-gas system fluids and in what form. After passing through the SBS, the exhaust stream was analyzed to determine particulate, ionic, elemental, and total mercury passing downstream of the SBS. In tests employing gases derived from the DM100 melter that were spiked with elemental mercury, the processing system provided gas temperatures and residence times that are representative of the WTP LAW vitrification system in order to assess the effect of those conditions on mercury speciation. The Decontamination Factor (DF) across the system in the tests with mercury-spiked DM100 melter exhaust was determined using the analytical data from EPA Method 30B (Fluegas Adsorption Mercury Speciation (FAMS TM )) exhaust samples and the amount of mercury detected in the SBS solutions. Mercury species used in melter feed crucible scale tests were divalent (chloride and iodide), monovalent (chloride and fluoride), and elemental mercury. Individual tests included only a single form of mercury in the feed. The results for total mercury mass balances in the crucible tests are also presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance assessment of long-legged tightly-baffled divertor geometries in the ARC reactor concept

Extremely intense power exhaust channels are projected for tokamak-based fusion power reactors; a means to handle them remains to be demonstrated. Advanced divertor configurations have been proposed as potential solutions. Recent modelling of tightly baffled, long-legged divertor geometries for the divertor test tokamak concept, ADX, has shown that these concepts may access passively stable, fully detached regimes over a broad range of parameters. The question remains as to how such divertors may perform in a reactor setting. To explore this, numerical simulations are performed with UEDGE for the long-legged divertor geometry proposed for the ARC pilot plant conceptual design - a device with projected heat flux power width (λq||) of 0.4 mm and power exhaust of 93 MW - first for a simplified Super-X divertor configuration (SXD) and then for the actual X-point target divertor (XPTD) being proposed. It is found that the SXD, combined with 0.5% fixed-fraction neon impurity concentration, can produce passively stable, detached divertor regimes for power exhausts in the range of 80-108 MW - fully accommodating ARC's power exhaust. The XPTD configuration is found to reduce the strike-point temperature by a factor of ~10 compared to the SXD for small separations (~1.4λq||) between main and divertor X-point magnetic flux surfaces. Even greater potential reductions are identified for reducing separations to ~1λq|| or less. The power handling response is found to be insensitive to the level of cross-field convective or diffusive transport assumed in the divertor leg. By raising the separatrix density by a factor of 1.5, stable fully detached divertor solutions are obtained that fully accommodate the ARC exhaust power without impurity seeding. To our knowledge, this is the first time an impurity-free divertor power handling scenario has been obtained in edge modelling for a tokamak fusion power reactor with λq|| of 0.4 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗