Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Disordered Berezinskii-Kosterlitz-Thouless transition and superinsulation

Here, we investigate the critical Berezinskii-Kosterlitz-Thouless (BKT) behavior of disordered two-dimensional Josephson-junction arrays (JJA) on the insulating side of the superconductor-insulator transition (SIT) taking into account the effect of hitherto ignored residual random dipole moments of the superconducting grains. We show that for weak Josephson coupling the model is equivalent to a Coulomb gas subjected to a disorder potential with logarithmic correlations. We demonstrate that strong enough disorder transforms the BKT divergence of the correlation length, ξ BKT ∝ exp (const / √T-T BKT ), characterizing the average distance between the unbound topological excitations of the opposite signs, into a more singular Vogel-Fulcher-Tamman (VFT) behavior, ξ VFT ∝ exp [const / (T-T VFT )] , which is viewed as a hallmark of glass transitions in glass-forming materials. We further show that the VFT criticality is a precursor of the transition into a nonergodic superinsulating state, while the BKT critical behavior implies freezing into an ergodic confined BKT state. Finally, our finding sheds light on the yet unresolved problem of the origin of the VFT criticality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First-forbidden continuum- and bound-state {beta}{sup -}-decay rates of bare {sup 205}Hg{sup 80+} and {sup 207}Tl{sup 81+} ions

We analyze the decay rates {lambda}{sub {beta}{sub c}{sup -}} and {lambda}{sub {beta}{sub b}{sup -}} of the continuum- and bound-state {beta}{sup -}-decays for bare {sup 205}Hg{sup 80+} and {sup 207}Tl{sup 81+} ions. For the ratio of the decay rates R{sub b/c}={lambda}{sub {beta}{sub b}{sup -}}/{lambda}{sub {beta}{sub c}{sup -}} we obtain the values R{sub b/c}=0.161 and R{sub b/c}=0.190 for bare {sup 205}Hg{sup 80+} and {sup 207}Tl{sup 81+} ions, respectively. The theoretical value of the ratio R{sub b/c}=0.190 for the decays of {sup 207}Tl{sup 81+} agrees well with the experimental data R{sub b/c}{sup exp}=0.188(18), obtained at GSI. The theoretical ratio R{sub b/c}=0.161 for {sup 205}Hg{sup 80+} is about 20% smaller than the experimental value R{sub b/c}{sup exp}=0.20(2), measured recently at GSI. We give arguments that the nuclear structure of the nuclei in the {sup 205}Hg{sup 80+}{yields} {sup 205}Tl{sup 81+} transition cannot provide such an enhancement of the ratio. We estimate the values of the continuum- and bound-state {beta}{sup -}-decay rates of the bare {sup 205}Hg{sup 80+} ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Competition between fusion-fission and quasifission processes in the {sup 32}S+{sup 184}W reaction

The angular distributions of fission fragments for the {sup 32}S+{sup 184}W reaction at center-of-mass energies of 118.8, 123.1, 127.3, 131.5, 135.8, 141.1, and 144.4 MeV are measured. The experimental fission excitation function is obtained. The anisotropy (A{sub exp}) is found by extrapolating each fission fragment angular distribution. The measured fission cross sections of the {sup 32}S+{sup 182,184}W reaction are decomposed into fusion-fission, quasifission, and fast-fission contributions by the dinuclear system model (DNS). The angular momentum distributions of the dinuclear system and compound nucleus calculated by the DNS model are used to reproduce the experimental capture and fusion excitation functions for both reactions and quantities K{sub 0}{sup 2}, <l{sup 2}>, and A{sub exp}, which characterize angular distributions of the fission products at the considered range of beam energy. The total evaporation residue excitation function for the {sup 32}S+{sup 184}W reaction calculated in the framework of the advanced statistical model is close to the available experimental data only up to about E{sub c.m.}approx =160 MeV. The underestimation of the experimental data at high excitation energies E{sub c.m.}>160 MeV is explained by the fact that the statistical model cannot reproduce the cross section of evaporation residues formed by the nonequilibrium mechanism, that is, without formation of the compound nucleus in the statistical equilibrium state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

QCD coupling below 1 GeV from the quarkonium spectrum

In this paper we extend the work synthetically presented by M. Baldicchi, A. V. Nesterenko, G. M. Prosperi, D. V. Shirkov, and C. Simolo [Phys. Rev. Lett. 99, 242001 (2007)] and give theoretical details and a complete set of numerical results. We exploit calculations within a Bethe-Salpeter (BS) formalism adjusted for QCD, in order to extract an experimental strong coupling {alpha}{sub s}{sup exp}(Q{sup 2}) below 1 GeV by comparison with the meson spectrum. The BS potential follows from a proper ansatz on the Wilson loop to encode confinement and is the sum of a one-gluon-exchange term and a confinement term. Besides, the common perturbative strong running coupling is replaced by the ghost-free expression {alpha}{sub E}(Q{sup 2}) according to the prescription of analytic perturbation theory (APT). The agreement of {alpha}{sub s}{sup exp}(Q{sup 2}) with the APT coupling {alpha}{sub E}(Q{sup 2}) turns out to be reasonably good from 1 GeV down to 200 MeV, thus confirming quantitatively the validity of the APT prescription in this range. Below this scale, the experimental points could give a hint on the vanishing of {alpha}{sub s}(Q{sup 2}) as Q{sup 2} approaches zero. This infrared behavior would be consistent with some lattice results as well as with the massive modification of the APT approach. As a main result, we claim that the combined BS-APT theoretical scheme provides quite satisfactory correlated understanding of very high and rather low energy phenomena from a few hundred MeV to a few hundred GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bottomonium spectrum at order v{sup 6} from domain-wall lattice QCD: Precise results for hyperfine splittings

The bottomonium spectrum is computed in dynamical 2+1 flavor lattice QCD, using nonrelativistic QCD for the b quarks. The main calculations in this work are based on gauge field ensembles generated by the RBC and UKQCD Collaborations with the Iwasaki action for the gluons and a domain-wall action for the sea quarks. Lattice spacing values of approximately 0.08 fm and 0.11 fm are used, and simultaneous chiral extrapolations to the physical pion mass are performed. As a test for gluon-discretization errors, the calculations are repeated on two ensembles generated by the MILC Collaboration with the Luescher-Weisz gauge action. Gluon-discretization errors are also studied in a lattice potential model using perturbation theory for four different gauge actions. The nonperturbative lattice QCD results for the radial and orbital bottomonium energy splittings obtained from the RBC/UKQCD ensembles are found to be in excellent agreement with experiment. To get accurate results for spin splittings, the spin-dependent order-v{sup 6} terms are included in the nonrelativistic QCD action, and suitable ratios are calculated such that most of the unknown radiative corrections cancel. The cancellation of radiative corrections is verified explicitly by repeating the calculations with different values of the couplings in the nonrelativistic QCD action. Using the lattice ratios of the S-wave hyperfine and the 1P tensor splitting, and the experimental result for the 1P tensor splitting, the 1S hyperfine splitting is found to be 60.3{+-}5.5{sub stat{+-}}5.0{sub syst{+-}}2.1{sub exp} MeV, and the 2S hyperfine splitting is predicted to be 23.5{+-}4.1{sub stat{+-}}2.1{sub syst{+-}}0.8{sub exp} MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

QCD result for the hyperfine splitting M{sub {Upsilon}(1S)}-M{sub {eta}{sub b}} and the value of {alpha}{sub s}

The measurement of the {eta}{sub b} mass, together with a QCD result for the hyperfine splitting E{sub HFS}=M{sub {Upsilon}(1S)}-M{sub {eta}}, allows us to determine the strong coupling constant {alpha}{sub s} at a low energy scale. The result {alpha}{sub s}(M{sub {Upsilon}(1S)}=0.197{+-}0.002|{sub {Delta}E{sub HFS}{sup exp}}{+-}0.002|{sub scheme}{+-}0.002|{sub {delta}<G{sup 2}>}{+-}0.006|{sub {delta}m{sub b}}{+-}0.005|{sub ho}, {alpha}{sub s}(M{sub Z{sup 0}})=0.124{+-}0.001|{sub {Delta}E{sub HFS}{sup exp}}{+-}0.001|{sub scheme}{+-}0.001|{sub {delta}<G{sup 2}>}{+-}0.003|{sub {delta}m{sub b}}{+-}0.002|{sub ho} is compatible with the current world average of {alpha}{sub s} reported by the Particle Data Group, and shows that the experimental lowest-lying {bar b}b hyperfine splitting can be reproduced in terms of a perturbative and nonperturbative QCD contribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modification of Coulomb law and energy levels of the hydrogen atom in a superstrong magnetic field

We obtain the following analytical formula which describes the dependence of the electric potential of a pointlike charge on the distance away from it in the direction of an external magnetic field B: {Phi}(z)=e/|z|[1-exp(-{radical}(6m{sub e}{sup 2})|z|)+exp(-{radical}((2/{pi})e{sup 3}B+6m{sub e}{sup 2})|z|)]. The deviation from Coulomb's law becomes essential for B>3{pi}B{sub cr}/{alpha}=3{pi}m{sub e}{sup 2}/e{sup 3{approx_equal}}6x10{sup 16} G. In such superstrong fields, electrons are ultrarelativistic except those which occupy the lowest Landau level (LLL) and which have the energy {epsilon}{sub 0}{sup 2}=m{sub e}{sup 2}+p{sub z}{sup 2}. The energy spectrum on which LLL splits in the presence of the atomic nucleus is found analytically. For B>3{pi}B{sub cr}/{alpha} it differs substantially from the one obtained without accounting for the modification of the atomic potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Inclusive $t\bar{t}$ Production Cross Section in $p\bar{p}$ Collisions at $\sqrt{s}=1.96$ TeV and Determination of the Top Quark Pole Mass

The inclusive cross section of top quark-antiquark pairs produced in pp¯ collisions at s=1.96 TeV is measured in the lepton+jets and dilepton decay channels. The data sample corresponds to 9.7 fb-1 of integrated luminosity recorded with the D0 detector during Run II of the Fermilab Tevatron Collider. Employing multivariate analysis techniques we measure the cross section in the two decay channels and we perform a combined cross section measurement. For a top quark mass of 172.5 GeV, we measure a combined inclusive top quark-antiquark pair production cross section of σtt¯=7.26±0.13(stat)-0.50+0.57(syst) pb which is consistent with standard model predictions. We also perform a likelihood fit to the measured and predicted top quark mass dependence of the inclusive cross section, which yields a measurement of the pole mass of the top quark. The extracted value is mt=172.8±1.1(theo)-3.1+3.3(exp) GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep inelastic scattering as a probe of entanglement

Using nonlinear evolution equations of QCD, we compute the von Neumann entropy of the system of partons resolved by deep inelastic scattering at a given Bjorken x and momentum transfer q 2 = - Q 2 . We interpret the result as the entropy of entanglement between the spatial region probed by deep inelastic scattering and the rest of the proton. At small x the relation between the entanglement entropy S ( x ) and the parton distribution x G ( x ) becomes very simple: S ( x ) = ln [ x G ( x ) ] . In this small x , large rapidity Y regime, all partonic microstates have equal probabilities—the proton is composed by an exponentially large number exp ( Δ Y ) of microstates that occur with equal and exponentially small probabilities exp ( - Δ Y ) , where Δ is defined by x G ( x ) ~ 1 / x Δ . For this equipartitioned state, the entanglement entropy is maximal—so at small x , deep inelastic scattering probes a maximally entangled state. Here, we propose the entanglement entropy as an observable that can be studied in deep inelastic scattering. This will then require event-by-event measurements of hadronic final states, and would allow to study the transformation of entanglement entropy into the Boltzmann one. We estimate that the proton is represented by the maximally entangled state at x ≤ 10 -3 ; this kinematic region will be amenable to studies at the Electron Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bose-Fermi cancellations without supersymmetry

We show that adjoint QCD features very strong Bose-Fermi cancellations in the large- N limit, despite the fact that it is manifestly nonsupersymmetric. The difference between the bosonic and fermionic densities of states in large- N adjoint QCD turns out to have a “two-dimensional” scaling ~ exp ( ℓ E ) for large energies E in finite spatial volume, where ℓ is a length scale associated with the curvature of the spatial manifold. In particular, all Hagedorn growth cancels, and so does the growth exp ( V 1 / 4 E 3 / 4 ) expected in a standard local four-dimensional theory in spatial volume V . In these ways, large- N adjoint QCD, a manifestly nonsupersymmetric theory, acts similarly to supersymmetric theories. We also show that at large- N the vacuum energy of multiflavor adjoint QCD is non-negative and exponentially small compared to the UV cutoff with several natural regulators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate Determination of the Neutron Skin Thickness of Pb 208 through Parity-Violation in Electron Scattering

We report a precision measurement of the parity-violating asymmetry A PV in the elastic scattering of longitudinally polarized electrons from 208 Pb. We measure A PV = 550 ± 16 (stat) ±8 (syst) parts per billion, leading to an extraction of the neutral weak form factor F W (Q 2 = 0.00616 GeV 2 ) = 0.368 ± 0.013. Combined with our previous measurement, the extracted neutron skin thickness is R n -R p = 0.283 ± 0.071 fm. The result also yields the first significant direct measurement of the interior weak density of 208 Pb: ρ$^0_W$ = -0.0796 ± 0.0036(exp) ± 0.0013(theo) fm -3 leading to the interior baryon density ρ$^0_b$ = 0.1480 ± 0.0036(exp) ± 0.0013(theo) fm -3 . Finally, the measurement accurately constrains the density dependence of the symmetry energy of nuclear matter near saturation density, with implications for the size and composition of neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bound-State Approach to the QCD Coupling Constant at Low-Energy Scales

We exploit theoretical results on the meson spectrum within the framework of a Bethe-Salpeter (BS) formalism adjusted for QCD, in order to extract an experimental coupling {alpha}{sub s}{sup exp}(Q{sup 2}) below 1 GeV by comparison with the data. Our results for {alpha}{sub s}{sup exp}(Q{sup 2}) exhibit a good agreement with the infrared safe analytic perturbation theory (APT) coupling from 1 GeV down to 200 MeV. As a main result, we claim that the combined BS-APT theoretical scheme provides us with a rather satisfactory correlated understanding of very high- and low-energy phenomena.0.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantification of arterial plaque and lumen density with MDCT

Purpose: This study aimed to derive a mathematical correction function in order to normalize the CT number measurements for small volume arterial plaque and small vessel mimicking objects, imaged with multidetector CT (MDCT). Methods: A commercially available calcium plaque phantom (QRM GmbH, Moehrendorf, Germany) and a custom built cardiovascular phantom were scanned with 320 and 64 MDCT scanners. The calcium hydroxyapatite plaque phantom contained objects 0.5-5.0 mm in diameter with known CT attenuation nominal values ranging 50-800 HU. The cardiovascular phantom contained vessel mimicking objects 1.0-5.0 mm in diameter with different contrast media. Both phantoms were scanned using clinical protocols for CT angiography and images were reconstructed with different filter kernels. The measured CT number (HU) and diameter of each object were analyzed on three clinical postprocessing workstations. From the resultant data, a mathematical formula was derived based on absorption function exp(-{mu}{sup *}d) to demonstrate the relation between measured CT numbers and object diameters. Results: The percentage reduction in measured CT number (HU) for the group of selected filter kernels, apparent during CT angiography, is dependent only on the object size (plaque or vessel diameter). The derived formula of the form 1-c{sup *}exp(-a{sup *}d{sup b}) showed reduction in CT number for objects between 0.5 and 5 mm in diameter, with asymptote reaching background noise for small objects with diameters nearing the CT in-plane resolution (0.35 mm). No reduction was observed for the objects with diameters equal or larger than 5 mm. Conclusions: A clear mathematical relationship exists between object diameter and reduction in measured CT number in HU. This function is independent of exposure parameters and inherent attenuation properties of the objects studied. Future developments include the incorporation of this mathematical model function into quantification software in order to automatically generate a true assessment of measured CT number (HU) corresponding to plaque physical density {rho} (g/cm{sup 3}). This is a significant development for the accurate, noninvasive classification of noncalcified arterial plaque.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according to the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.

60 APPLIED LIFE SCIENCES↗

SU-C-BRE-02: BED Vs. Local Control: Radiobiological Effect of Tumor Volume in Monte Carlo (MC) Lung SBRT Planning

Purpose: SBRT with hypofractionated dose schemata has emerged a compelling treatment modality for medically inoperable early stage lung cancer patients. It requires more accurate dose calculation and treatment delivery technique. This report presents the relationship between tumor control probability(TCP) and size-adjusted biological effective dose(sBED) of tumor volume for MC lung SBRT patients. Methods: Fifteen patients who were treated with MC-based lung SBRT to 50Gy in 5 fractions to PTVV100%=95% were studied. ITVs were delineated on MIP images of 4DCT-scans. PTVs diameter(ITV+5mm margins) ranged from 2.7–4.9cm (mean 3.7cm). Plans were generated using non-coplanar conformal arcs/beams using iPlan XVMC algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX with HD-MLCs and 6MVSRS(1000MU/min) mode, following RTOG-0813 dosimetric guidelines. To understand the known uncertainties of conventional heterogeneities-corrected/uncorrected pencil beam (PBhete/ PB-homo) algorithms, dose distributions were re-calculated with PBhete/ PB-homo using same beam configurations, MLCs and monitor units. Biologically effective dose(BED10) was computed using LQ-model with α/β=10Gy for meanPTV and meanITV. BED10-c*L, gave size-adjusted BED(sBED), where c=10Gy/cm and L=PTV diameter in centimeter. The TCP model was adopted from Ohri et al.(IJROBP, 2012): TCP = exp[sBEDTCD50]/ k /(1.0 + exp[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy; and more realistic MC-based TCP was computed for PTV(V99%). Results: Mean PTV PB-hete TCP value was 6% higher, but, mean PTV PB-homo TCP value was 4% lower compared to mean PTV MC TCP. Mean ITV PB-hete/PB-homo TCP values were comparable (within ±3.0%) to mean ITV MC TCP. The mean PTV(V99%)had BED10=90.9±3.7%(median=92.2%),sBED=54.1±8.2%(median=53.5%) corresponding to mean MC TCP value of 84.8±3.3%(median=84.9%) at 2- year local control. Conclusion: The TCP model which incorporates BED10 and tumor diameter indicates that radiobiological effect of target volume and dose calculation algorithm significantly affects TCP for lung SBRT patients. Dose calculation using MC-based algorithm is more realistic with tissue heterogeneities and is routinely performed in our clinic. Patients will be followed up to determine whether TCP prediction correlate clinical outcomes.

60 APPLIED LIFE SCIENCES↗

SU-C-BRE-03: Dual Compartment Mathematical Modeling of Glioblastoma Multiforme (GBM)

Purpose: To explore the aggressive recurrence and radioresistence of GBM with a dual compartment tumor survival mathematical model based on intrinsic tumor heterogeneity, cancer stem cells (CSC) and differentiated cancer cells (DCC). Methods: The repopulation and differentiation responses to radiotherapy of a solid tumor were simulated using an Ordinary Differential Equation (ODE). To obtain the tumor radiobiological parameters, we assumed that a tumor consists of two subpopulations, each with its distinctive linear quadratic parameters. The dual compartment cell survival model was constructed as SF(D)=F × exp(-α{sub 1} D-β{sub 1}D{sup 2}) + (1-F) × exp(-α{sub 2}D-β{sub 2}D{sup 2}) for a single fraction of treatment, with F as the fraction of CSC, and α and β describing the radiological properties of each population. Robust least square fitting was performed on clonogenic survival data from one GBM (U373MG) and one NSCLC (H460) cell line. The fit parameters were then used in the ODE model to predict treatment outcome of various treatment schemes. Results: The fit parameters from GBM cell survival data were (F, α{sub 1}, β{sub 1}, α{sub 2}, β{sub 2})=(0.0396, 0.0801, 0.0006, 0.1363, 0.0279), exhibiting two populations with distinctive radiological properties, CSC more radioresistant than DCC. The GBM cell line exhibited significantly poorer tumor control than its single compartment model prediction and NSCLC, which responded well to hypofrationation. The increased radioresistance was due to rapid regrowth of the DCC compartment triggered by its depletion while maintaining a viable CSC population. The rapid regrowth can be reduced by treating dose fractions ≤ 2 Gy with a prolonged treatment period. Conclusion: The interaction between a radioresistant CSC compartment and DCC compartment can explain the poor clinical outcome of GBM after radiotherapy despite dose escalation and hypofractionation attempts. Lower dose fractions result in better treatment outcome but still eventually recurs. Dose escalation beyond 100 Gy and/or differentiation therapy will be vital in achieving GBM tumor control.

60 APPLIED LIFE SCIENCES↗

WE-H-BRA-02: Radiobiological Modeling of Tumor Control Probability (TCP) and Radiation-Induced Pneumonitis (RP) for Lung Cancer Patients Treated with Monte Carlo-Based Lung SBRT

Purpose: To present radiobiological modeling of TCP using tumor size-adjusted BED(s-BED)and PTV(D99) to lung SBRT patients treated with X-ray Voxel Monte Carlo(XVMC) algorithm, apply parameterized Lyman-NTCP model to predict grade-2 RP and subsequently, compare with clinical outcomes/observations. Methods: Dosimetric parameters and clinical follow-up for XVMC-based lung-SBRT patients were retrospectively evaluated. Patients were treated at Novalis-TX with hybrid(2 non-coplanar partial-arcs plus 3–6 static-beams)plan using HD-MLC/6MV-SRS-beam.For TCP,s-BED modelling was utilized: TCP=EXP[sBED-TCD50]/k/(1.0+EXP[sBED-TCD50]/k), where k=31Gy corresponding to TCD50=0Gy and s-BED was defined as BED10 minus 10 times the tumor diameter(in centimeters)by Ohri et al.(IJROBP,2012). For 2-yr local-control, we used more-realistic MC-computed PTVD99 as a predictive parameter, s-BED(D99).Due to relatively shorter median follow-up interval(12-months),Kaplan-Meier curves were generated to estimate 2-yr observed local-control and compared to predicted-rate by TCP modeling. For NTCP, we employed parameterized Lyman-NTCP model utilizing normal-lung DVH and α/β=3Gy fitted to predict grade-2 RP after lung-SBRT. Results: Total 108 patients (137 tumors) treated for 35–70Gy in 3–5 fractions, either primary-lung(n=74)or metastatic-lung(n=53)tumors were included.F or the given prescription dose with MC-computed MUs, 2-yr local-control rates with s-BED(D99) was 87±8%. Kaplan-Meier generated observed local-control rate at 2-yr was 87.5%,suggesting that PTV(D99) could be a potential predictor (p-value=0.38). Observed vs predicted TCP for primary-lung tumors and metastatic tumors were 97% vs 88±7% and 94% vs 86±9%.NTCP model predicted well for symptomatic-RP with predicted vs observed (3±5% vs 2%). Radiographic and clinically significant RP was observed in 13% and 2% of patients. Higher rates of radiographic change were observed in patients who received >50Gy compared to ≤50Gy(24% vs 10%). Conclusion: Utilizing MC-computed PTVD99, our TCP results were well correlated with clinical outcome. The predicted grade-2 RP rate was comparable to clinical observations. Clinical application of these radiobiological models may potentially allow for target dose escalation and/or lung-toxicity reduction. Further validation of these radiobiological models with longer follow up interval for large cohorts of lung-SBRT patients is anticipated.

60 APPLIED LIFE SCIENCES↗

Experimental investigation of performance differences between coherent Ising machines and a quantum annealer

Physical annealing systems provide heuristic approaches to solving combinatorial optimization problems. Here, we benchmark two types of annealing machines—a quantum annealer built by D-Wave Systems and measurement-feedback coherent Ising machines (CIMs) based on optical parametric oscillators—on two problem classes, the Sherrington-Kirkpatrick (SK) model and MAX-CUT. The D-Wave quantum annealer outperforms the CIMs on MAX-CUT on cubic graphs. On denser problems, however, we observe an exponential penalty for the quantum annealer [exp(–α DW N 2 )] relative to CIMs [exp(–α CIM N)] for fixed anneal times, both on the SK model and on 50% edge density MAX-CUT. This leads to a several orders of magnitude time-to-solution difference for instances with over 50 vertices. An optimal–annealing time analysis is also consistent with a substantial projected performance difference. The difference in performance between the sparsely connected D-Wave machine and the fully-connected CIMs provides strong experimental support for efforts to increase the connectivity of quantum annealers.

42 ENGINEERING↗