Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Computed And Measured Flow In A Turnaround Duct

Report presents theoretical and experimental study of subsonic flow of air in 180 degree-turnaround duct of rectangular cross section. Purpose of study to conduct partial simulation of conditions similar to those in axisymmetric duct of Space Shuttle main engine. Part of continuing effort to develop capability to simulate complicated turbulent internal flows with large curvatures like those in rocket engines and turbomachinery.

Monson, Daryl J.↗

A system to measure flow moisture content in hypersonic wind tunnels

The technique and equipment is described which is used for obtaining data on the moisture content in two NASA Langley Hypersonic Wind Tunnels. A detailed description of the sampling system and its operation is presented along with the moisture analyzer used. The procedure used for converting dew point to parts of water per million by volume (ppmv) is included with graphs that show tunnel moisture content at various pressures.

West, James W.↗

On the determination of local instantaneous averages in particulate flow measurements

Determination of instantaneous local average particle density of a gas-particle suspension requires satisfying both the time scale relation and the volume scale relation or its continuum counter part of time averaging. This procedure was validated by comparing simultaneous velocity and mass flux measurements and the laser phase Doppler measurements.

Vandewall, R. E.↗

Comparison Between Predicted and Experimentally Measured Flow Fields at the Exit of the SSME HPFTP Impeller

Validation of CFD codes is a critical first step in the process of developing CFD design capability. The MSFC Pump Technology Team has recognized the importance of validation and has thus funded several experimental programs designed to obtain CFD quality validation data. The first data set to become available is for the SSME High Pressure Fuel Turbopump Impeller. LDV Data was taken at the impeller inlet (to obtain a reliable inlet boundary condition) and three radial positions at the impeller discharge. Our CFD code, TASCflow, is used within the Propulsion and Commercial Pump industry as a tool for pump design. The objective of this work, therefore, is to further validate TASCflow for application in pump design. TASCflow was used to predict flow at the impeller discharge for flowrates of 80, 100 and 115 percent of design flow. Comparison to data has been made with encouraging results.

Bache, George↗

Setting up a Rayleigh Scattering Based Flow Measuring System in a Large Nozzle Testing Facility

A molecular Rayleigh scattering based air density measurement system has been built in a large nozzle testing facility at NASA Glenn Research Center. The technique depends on the light scattering by gas molecules present in air; no artificial seeding is required. Light from a single mode, continuous wave laser was transmitted to the nozzle facility by optical fiber, and light scattered by gas molecules, at various points along the laser beam, is collected and measured by photon-counting electronics. By placing the laser beam and collection optics on synchronized traversing units, the point measurement technique is made effective for surveying density variation over a cross-section of the nozzle plume. Various difficulties associated with dust particles, stray light, high noise level and vibration are discussed. Finally, a limited amount of data from an underexpanded jet are presented and compared with expected variations to validate the technique.

Panda, Jayanta↗

Laser velocimetry and holographic interferometry measurements in transonic flows

Measurements of the transonic flow about a two-dimensional airfoil have been made with holographic interferometry and laser velocimetry. Quantitative data obtained with the interferometer are compared to the laser velocimeter and surface pressure measurements to evaluate the accuracy of the technique. Good agreement in the results confirmed the two-dimensionality of the flow and the potential of the interferometer in making unsteady transonic flow measurements in the future.

Bachalo, W. D.↗

Improved visualization of flow field measurements

A capability was developed that makes it possible to apply to measured flow field data the visualization tools developed to display numerical solutions for computational fluid dynamic problems. The measurement monitor surface (MMS) procedure was applied to the analysis of flow field measurements within a low aspect ratio transonic axial flow fan rotor obtained with 2-D laser anemometry. The procedure generates input for the visualization tools developed to display numerical solutions for computational fluid dynamics problems. The relative Mach number contour plots obtained by this method resemble the conventional contour plots obtained by more traditional methods. The results show that the MMS procedure can be used to generate input for the multidimensional processing and analysis tools developed for data from numerical flow field simulations. They show that an experimenter can apply the MMS procedure to his data and then use an interactive graphics program to display scalar quantities like the Mach number by profiles, carpet plots, contour lines, and surfaces using various colors. Also, flow directionality can be shown by display of vector fields and particle traces.

Miles, Jeffrey Hilton↗

Improved visualization of flow field measurements

A capability is proposed that makes it feasible to apply to measured flow field data the visualization tools developed to display numerical solutions for computational fluid dynamic problems. The measurement monitor surface (MMS) methodology was used for the analysis of flow field measurements within a low-aspect-ratio transonic axial-flow fan rotor acquired with two-dimensional laser anemometry. It is shown that the MMS method may be utilized to generate input for the multidimensional processing and analytical tools developed for numerical flow field simulation data. Thus an experimenter utilizing an interactive graphics program could illustrate scalar quantities such as Mach number by profiles, contour lines, carpet plots, and surfaces employing various color intensities. Also, flow directionality can be shown by the display of vector fields and particle traces.

Miles, Jeffrey Hilton↗

Turbulent Flow Field Measurements of Separate Flow Round and Chevron Nozzles with Pylon Interaction Using Particle Image Velocimetry

Particle Image Velocimetry (PIV) measurements for six separate flow bypass ratio five nozzle configurations have recently been obtained in the NASA Langley Jet Noise Laboratory. The six configurations include a baseline configuration with round core and fan nozzles, an eight-chevron core nozzle at two different clocking positions, and repeats of these configurations with a pylon included. One run condition representative of takeoff was investigated for all cases with the core nozzle pressure ratio set to 1.56 and the total temperature to 828 K. The fan nozzle pressure ratio was set to 1.75 with a total temperature of 350 K, and the freestream Mach number was M = 0.28. The unsteady flow field measurements provided by PIV complement recent computational, acoustic, and mean flow field studies performed at NASA Langley for the same nozzle configurations and run condition. The PIV baseline configuration measurements show good agreement with mean flow field data as well as existing PIV data acquired at NASA Glenn. Nonetheless, the baseline configuration turbulence profile indicates an asymmetric flow field, despite careful attention to concentricity. The presence of the pylon increases the upper shear layer turbulence levels while simultaneously decreasing the turbulence levels in the lower shear layer. In addition, a slightly shorter potential core length is observed with the addition of the pylon. Finally, comparisons of computational results with PIV measurements are favorable for mean flow, slightly over-predicted for Reynolds shear stress, and underpredicted for Reynolds normal stress components.

Doty, Michael J.↗

The application of laser Rayleigh scattering to gas density measurements in hypersonic helium flows

Measurements of the mean static free-stream gas density have been made in two Langley Research Center helium facilities, the 3-inch leg of the high-Reynolds-number helium complex and the 22-inch hypersonic helium tunnel. Rayleigh scattering of a CW argon ion laser beam at 514.5 nm provided the basic physical mechanism. The behavior of the scattered signal was linear, confirmed by a preliminary laboratory study. That study also revealed the need to introduce baffles to reduce stray light. A relatively simple optical system and associated photon-counting electronics were utilized to obtain data for densities from 10 to the 23rd to 10 to the 25th per cu m. The major purpose, to confirm the applicability of this technique in the hypersonic helium flow, was accomplished.

Hoppe, J. C.↗

Fluid flow volume measurements using a capacitance/conductance probe system

A probe system has been developed to measure the flow volume of a single fluid passing through an orifice or flow line. The system employs both capacitance and a conductance probe at the orifice, together with phase detection and data acquisition circuitry to measure flow volume and salinity under low or zero gravity conditions. A wide variety of frequencies can be used for the radio frequency (RF) signal source which is chosen primarily by the capacitance of the orifice probe and the fluid passing through the orifice. Rapid measurements are made using the reflected signal from the orifice probe to determine the 'instantaneous' permittivity of the fluid/gas mixture passing through. The 'instantaneous' measurements are integrated over time to determine flow volume. Analysis reveals that a narrow orifice helps to reduce non-linearities caused by differing flow rates. The geometry of 'deflectors' and 'directors' for the flowing fluid are important in obtaining linearity. Measured data shows that a volume measurement accuracy of approximately four percent can be consistently achieved. The prototype hardware system and associated software have been optimized and are available for further applications. The system has immediate application in low or zero gravity environments for measurements of urine or other liquid volumes.

Nguyen, T. X.↗

NASA Tech Briefs, June 2004

Topics covered include: COTS MEMS Flow-Measurement Probes; Measurement of an Evaporating Drop on a Reflective Substrate; Airplane Ice Detector Based on a Microwave Transmission Line; Microwave/Sonic Apparatus Measures Flow and Density in Pipe; Reducing Errors by Use of Redundancy in Gravity Measurements; Membrane-Based Water Evaporator for a Space Suit; Compact Microscope Imaging System with Intelligent Controls; Chirped-Superlattice, Blocked-Intersubband QWIP; Charge-Dissipative Electrical Cables; Deep-Sea Video Cameras Without Pressure Housings; RFID and Memory Devices Fabricated Integrally on Substrates; Analyzing Dynamics of Cooperating Spacecraft; Spacecraft Attitude Maneuver Planning Using Genetic Algorithms; Forensic Analysis of Compromised Computers; Document Concurrence System; Managing an Archive of Images; MPT Prediction of Aircraft-Engine Fan Noise; Improving Control of Two Motor Controllers; Electro-deionization Using Micro-separated Bipolar Membranes; Safer Electrolytes for Lithium-Ion Cells; Rotating Reverse-Osmosis for Water Purification; Making Precise Resonators for Mesoscale Vibratory Gyroscopes; Robotic End Effectors for Hard-Rock Climbing; Improved Nutation Damper for a Spin-Stabilized Spacecraft; Exhaust Nozzle for a Multitube Detonative Combustion Engine; Arc-Second Pointer for Balloon-Borne Astronomical Instrument; Compact, Automated Centrifugal Slide-Staining System; Two-Armed, Mobile, Sensate Research Robot; Compensating for Effects of Humidity on Electronic Noses; Brush/Fin Thermal Interfaces; Multispectral Scanner for Monitoring Plants; Coding for Communication Channels with Dead-Time Constraints; System for Better Spacing of Airplanes En Route; Algorithm for Training a Recurrent Multilayer Perceptron; Orbiter Interface Unit and Early Communication System; White-Light Nulling Interferometers for Detecting Planets; and Development of Methodology for Programming Autonomous Agents.

Source record↗