Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault Behavior”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State-of-the-art on research and applications of machine learning in the building life cycle

Fueled by big data, powerful and affordable computing resources, and advanced algorithms, machine learning has been explored and applied to buildings research for the past decades and has demonstrated its potential to enhance building performance. This study systematically surveyed how machine learning has been applied at different stages of building life cycle. By conducting a literature search on the Web of Knowledge platform, we found 9579 papers in this field and selected 153 papers for an in-depth review. The number of published papers is increasing year by year, with a focus on building design, operation, and control. However, no study was found using machine learning in building commissioning. There are successful pilot studies on fault detection and diagnosis of HVAC equipment and systems, load prediction, energy baseline estimate, load shape clustering, occupancy prediction, and learning occupant behaviors and energy use patterns. None of the existing studies were adopted broadly by the building industry, due to common challenges including (1) lack of large scale labeled data to train and validate the model, (2) lack of model transferability, which limits a model trained with one data-rich building to be used in another building with limited data, (3) lack of strong justification of costs and benefits of deploying machine learning, and (4) the performance might not be reliable and robust for the stated goals, as the method might work for some buildings but could not be generalized to others. Finally, findings from the study can inform future machine learning research to improve occupant comfort, energy efficiency, demand flexibility, and resilience of buildings, as well as to inspire young researchers in the field to explore multidisciplinary approaches that integrate building science, computing science, data science, and social science.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Explaining System-Level Prognostics with Established Machine Learning Methods

System-level prognostics is crucial for ensuring reliability and enabling predictive maintenance in complex systems with interconnected components. This study presents a framework that integrates data-driven methods to predict the remaining useful life (RUL) of a subsystem under multiple and concurrent faults within a nuclear power plant system with explainable artificial intelligence (XAI). A nuclear power plant (NPP) operation was simulated to model the degradation behavior of NPP components, and four machine learning models—Gradient Boosting Regressor (GBR), Support Vector Regressor (SVR), Fully Connected Neural Network (FCNN), and Long Short-Term Memory (LSTM)—were evaluated for prognostics with a novel system RUL parameter. The LSTM model demonstrated potential superior repeatability, while SHAP (SHapley Additive exPlanations) for explainability provided consistent and trustworthy global explanations. In contrast, LIME (Local Interpretable Model-agnostic Explanations) offered localized interpretability but showed reduced stability for sequential data. Key findings include the interplay between component-level degradation and system-wide performance, with LSTM effectively capturing these dynamics through sequence-level predictions. The XAI techniques enhanced transparency by identifying critical features influencing model predictions and aligning with domain knowledge. Furthermore, this framework has significant implications for improving trust and understanding in predictive maintenance, particularly in safety-critical industries like nuclear energy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Process prediction and detection of faults using probabilistic bidirectional recurrent neural networks on real plant data

Attaining Industry 4.0 for manufacturing operations requires advanced monitoring systems and real-time data analytics of plant data, among other topics. We propose a Probabilistic Bidirectional Recurrent Network (PBRN) for industrial process monitoring for the early detection of faults. The model is based on a Gated Recurrent Unit (GRU) neural network that allows the model to retain long-term dependencies between sensor data along a time horizon, hence learning the dynamic behavior of the process. To reduce the false-positive detection rate of the model, we compel the model to learn from a highly noisy sensor reading while outputting noise-free sensor outputs. The performance of the proposed model is compared to other data-driven statistical process monitoring schemes using real plant data from an industrial Air Separations Unit (ASU) containing noisy sensor readings. We show that the model can learn from noisy data without reducing its performance. Using two different fault cases, we demonstrate the model’s ability to carry out early fault detection with average false-positive rates of 2.9% and 4.9% for both fault cases. The missed detection rates are 0.1% and 0.2%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dislocation nano-hydrides in nickel: Nucleation, evolution and effects on dislocation behaviors

Nano-hydrides have been predicted to precipitate at the core of edge dislocations in the Ni-H system, a mechanism that may promote hydrogen embrittlement. However, nano-hydride nucleation, growth, and effects on dislocation behavior have seldom been explored. This work combines molecular dynamics grand canonical Monte Carlo (MD-GCMC) simulations and continuum modeling to uncover a wide range of phenomena linked to dislocation nano-hydrides. Simulations reveal that nano-hydrides can be stabilized at dislocation cores with all character angles, including screw segments, due to the hydrostatic stresses around the cores of the Shockley partials. Nano-hydride nucleation takes place in these regions, and growth is dictated by the character angle θ of the perfect dislocation. The equilibrium stacking fault width d eq varies dynamically to increase the local hydrostatic stress field and facilitate the formation of the nano-hydride, forming a constriction-like feature and leading to three distinct behaviors: d eq decreases for θ > 30°, d eq remains unchanged for θ = 30°, and d eq increases for θ < 30°. Remote hydrostatic and Escaig stresses are also shown to influence the nucleation stage, implying stress concentrations such as those ahead of crack tips may facilitate nano-hydride precipitation. Moreover, we identify a new hydrogen-induced 60° dislocation reaction that emits a Shockley partial on a conjugate plane, with potential implications for twin nucleation. Testable predictions from this study are then used to reinterpret previous results from the literature. In conclusion, these findings provide a comprehensive framework to assess nano-hydride formation and evolution at dislocations in nickel and other face-centered cubic metals, with important implications to hydrogen embrittlement.

Dislocations↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Behavior of Tidally Triggered Earthquakes Depends on Fluid Conditions

Seismicity at The Geysers geothermal field and in Oklahoma is heavily influenced by industrial activities related to energy production, though the mechanism in which earthquakes are induced or triggered is different. At The Geysers, much of the seismicity is linked to thermoelastic stresses caused by injecting cold water into hot rocks, whereas in Oklahoma, the seismicity is linked to a reduction of confining stress on faults due to increasing pore pressure resulting from wastewater injections. Here, in this study, we show that these contrasting conditions are also evident in tidally triggered earthquakes. At The Geysers, earthquakes preferentially occur during maximum extensional stress, which does not occur at the same time as maximum shear stress on optimally oriented faults in the regional stress field. In Oklahoma, earthquakes preferentially occur during maximum shear stress on optimally oriented faults rather than maximum extensional stress. The magnitude of tidal extensional stress is naturally much greater than tidal shear stress. However, in a fluid-saturated environment, pore pressure responds to changes in volume, which can counteract or reduce the effect of the applied stress. The difference in behavior at these two sites is indicative of the level of coupling between applied stress and pore pressure, corresponding to unsaturated conditions at The Geysers and high pore pressure in Oklahoma.

58 GEOSCIENCES↗

A review of crosstalk polymorphic circuits and their scalability

Using a control variable, the functionality of Polymorphic circuits can be modified, making them adaptable and useful for reconfiguring circuit behavior — all the way from gate level to system level. State-of-the art polymorphic circuits are based on custom non-linear circuit design or emerging devices such as ambipolar FET, configurable magnetic devices etc. While some of these approaches are inefficient in performance, others involve exotic devices. The Crosstalk computing based polymorphic circuits offer a fresh perspective. In Crosstalk, the interconnect interference between nanoscale metal lines is intentionally engineered to exhibit the programmable Boolean logic behavior. This approach relies on the coupling between metal lines and not on the transistors for computing, resulting in better scalability, security by obscurity, and fault tolerance by reconfiguration. Our novel approach is backed by the mathematical formulation that conveys the rationale to generalize and achieve a wide variety of polymorphic circuits. Our experiments, including design, simulation, and Power Performance Area (PPA) characterization results indicate that crosstalk circuits provide significant improvement in transistor count (about 3x), switching energy (2x), and speed (1.5x) for polymorphic logic circuits. In the best-case scenario, the transistor count reduction is 5x. This paper presents Crosstalk computing’s fundamentals, polymorphism and the scalability aspects to compete/co-exist with CMOS for digital logic implementations below 10 nm. Our scalability study uses Open Source 7 nm PDK, considers all process variation aspects and accommodates worst-case scenarios. The study results for various benchmark circuits show that the Crosstalk technology is a viable alternative to CMOS for digital logic implementations below 10 nm, having 48% density, 57% power, and 10% performance gains over equivalent CMOS counterparts. Finally, we compare Crosstalk Polymorphic Circuit design technique with similar approaches described in related works and discuss its features and constraints.

97 MATHEMATICS AND COMPUTING↗

Machine-Learning-Based Analysis of the Guy-Greenbrier, Arkansas Earthquakes: A Tale of Two Sequences

Here, we revisited the June 2010 to October 2011 Guy-Greenbrier earthquake sequence in central Arkansas using PhaseNet, a deep neural network trained to pick P and S arrival times. We applied PhaseNet to continuous waveform data and used phase association and hypocenter relocation to locate nearly 90,000 events. Our catalog suggests that the sequence consists of two adjacent earthquake sequences on the same fault and that the second sequence may be associated with the wastewater disposal well to the west of the Guy-Greenbrier Fault, rather than the wells to the north and the east that were previously implicated. We find that each sequence is composed of many small clusters that exhibit diffusion along the fault at shorter timescales. Our study demonstrates that machine-learning-based earthquake catalog development is now feasible and will yield new insights into earthquake behavior.

58 GEOSCIENCES↗

Stratigraphy‐Induced Localization of Microseismicity During CO 2 Injection in Illinois Basin

Abstract Subsurface fluid injection stimulates complex hydromechanical interaction, necessitating the integration of geomechanical data across spatial and temporal scales to consider the sophisticated behavior. Induced seismic response is usually associated with the complex reservoir architecture and pre‐existing features that are three‐dimensional, such as local stratigraphy, fractures, faults, and other discontinuities. This study encompasses laboratory characterization of the coupled hydromechanical response of cores extracted from rock formations in Illinois Basin: reservoir ‐ Mt. Simon sandstone, basal seal ‐ Argenta sandstone, and crystalline basement ‐ Precambrian rhyolite. High‐resolution numerical modeling allows considering the three‐dimensional complexity of the Illinois Basin Decatur Project with spatial resolution comparable to one of the active seismic surveys. A detailed reconstruction of the evolving state of stress in formations lacking direct stress measurements is achieved by numerical modeling that integrated laboratory‐derived hydromechanical properties, a porosity‐permeability relationship, active seismic data, and an inverted three‐dimensional porosity distribution. It appears that the microseismic clusters, mainly observed in the crystalline basement during the injection, are linked to zones experiencing more critically stressed conditions prior to injection. These zones have a potential for reactivation during the injection and are attributed to the specific local stratigraphy of the injection site, as well as transfer of triggering perturbations during the injection.

Bondarenko, N. [University of Illinois Urbana‐Cham↗

Guest Editorial: Special section on Resilient Control of Cyber-Physical Power and Energy Systems

Our power and energy systems are becoming more and more integrated and interconnected. The increasing integration of edge devices and dependence on cyber infrastructure provides both the potential for benefits and risks. The integration enables more dynamic and flexible control paradigms while at the same time increasing the cyberattack surface and uncertainty of behavior. Control methodology in this new world must be designed for resilience and must have the ability to withstand, react, and respond to both physical faults and cyber-induced threats. Finally, understanding system resilience under adverse conditions requires studying control performance and how cyber infrastructure can integrate with and support the overall resilience of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variability of near-fault seismic risk to reinforced concrete buildings based on high-resolution physics-based ground motion simulations

Broadband physics-based simulated earthquake ground motions are utilized to characterize the regional-scale seismic risk to modern reinforced concrete (RC) structures. A highly dense dataset of ground motions covering a 100-km urn:x-wiley:00988847:media:eqe3413:eqe3413-math-0001 40-km domain was generated using kinematic fault rupture models with varying rupture characteristics to represent shallow crustal earthquakes and resolved up to frequencies of 5 Hz. Over 40,000 nonlinear response history simulations of short- and mid-rise RC special moment frame buildings were conducted using simulation models that are capable of representing nonlinear behavior and component deterioration effects. The spatial variability of structural risk within a single earthquake scenario and between different rupture scenarios is examined, and the regions of strongest directivity effects and highest structural demands are identified. The structural demands may vary by factor of up to 8.0 at very short distances from the fault, and the large dispersion in the demands decreases significantly beyond a distance of 15 km. The interstory drift and member rotation demands are substantially impacted by important features of the geological structure and the characteristics of the rupture scenarios, particularly the presence of localized high-slip regions. The frequency characteristics of the structures are found to play an important role in determining the effects of near-fault ground motions on the structural response and expected damage. The results of this study suggest that the simulated ground motions, particularly those generated using the hybrid rupture approach, may offer reasonable structural risk estimates for low-frequency structures and conservative estimates for high-frequency structures.

58 GEOSCIENCES↗

Impact analysis of DERs on bulk power system stability through the parameterization of aggregated DER_a model for real feeders

With an ever increasing percentage of distributed energy resources (DERs) connected behind the meter in the distribution system, it is becoming increasingly important to equip transmission planners with the visibility of DER dynamic performance in distribution system. Not having visibility of the disconnection of DERs with the occurrence of transmission events, could result in an erroneous view of the stability of bulk power system. Here, in this paper, a parameterized aggregated model (DER_a) serves as a representation of the distribution-level dynamics of real residential feeders, which is used for analysis of bulk power system stability. The parameters are obtained by executing dynamic Monte Carlo simulations. Faults are then induced at the substation level causing the DERs to trip which subsequently enables the parameterization of the low and high voltage breakpoints (v l0 , v l1 , v h0 , and v h1 ) of the DER_a model’s partial voltage trip block. These parameters are then utilized to study the effectiveness of the DER_a model to represent the behavior of the aggregated DERs’ response and their impact on the bulk power system. The case study shows the ability of the positive-sequence DER_a model to provide an accurate estimation of DERs that are susceptible to trip due to 3-$\phi$ and 1-$\phi$ faults of transmission.

14 SOLAR ENERGY↗

Adoption of AI in the Utility T&D Sector: Use Cases, Consequence, Assessment and Benefits

Digital transformation and utilization of artificial intelligence (AI) in the electric grid are fundamentally changing the industry’s approach to common problems and enabling a broader paradigm shift in grid planning and operations. The change in approach is circularly both enabling and driving modernization, with load growth and reliable management of data center and AI infrastructure shifting away from planning approaches with relatively predictable behaviors and toward a mix of consumer and industrial choices that surpass human cognitive abilities to process. This movement has potential to condition humans to not understand the system on which the AI depends, while requiring it for development of the necessary infrastructure. Approaches which would address most likely grid conditions and events, such as faults, aging of equipment, and weather, now must also account for large loads which shift not based upon weather or time of day, but the computational load. Quantifying computational load is independent of the traditional grid forecasting variables, where a data center’s aggregate load is determined by user and AI system behavior and decoupled from normal grid planning and operations. AI is both the cause and solution for these challenges, with new grid planning tools integrating massive amounts of decisions into frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atomic faulting drives exceptional toughness in low thermal expansion chromium alloys

Endowing functional properties with mechanical responses in traditional metals has been a frontier topic, akin to transforming base metal into gold. Chromium and its alloys, with their functional deficiencies and limited ductility, serve as typical examples. Herein, we report a Cr96Fe4Ge1.3B1 alloy that unifies low thermal expansion (LTE, αl = 1.79 × 10-6 K-1, 200 − 315 K) with exceptional toughness (240.2 J·cm-3). The enhancement in mechanical responses is primarily attributed to layered Cr2B intermetallic precipitates, which ameliorate interfacial cohesion and simultaneously refine the grain structure. The weakened interlayer interactions within the Cr-B layers facilitate the nucleation and movement of numerous tiny stacking faults in precipitates, efficiently alleviating strain energy and resulting in marked work-hardening ability. Additionally, antiferromagnetic fluctuations in the BCC matrix contribute to the unique LTE behavior. This paves the way for the design of high-performance alloys featuring layered-symmetry precipitates.

Yu, Chengyi [University of Science and Technology ↗

Analyzing impact of $\mathrm{DER}$ on $\mathrm{FIDVR}$ - comparison of $\mathrm{EMT}$ simulation of a combined transmission and distribution grid with aggregated positive sequence models

The increase in percentage of distributed energy resources (DERs) brings in a degree of uncertainty in bulk power system planning and operations. Further, the presence of 1 - φ induction motors introduces the possibility of motor stalling and fault induced delayed voltage recovery (FIDVR). With newer versions of IEEE Std 1547™ there can be the opportunity to obtain dynamic voltage support from DERs. In this report, the impact of DERs providing dynamic voltage on the dynamic behavior of 1 - φ induction motors is examined in detail along with an exploration of the need for simulation platforms that go beyond positive sequence. The studies discussed here are carried out both in detailed electromagnetic time domain and in positive sequence domain for comparison.

24 POWER TRANSMISSION AND DISTRIBUTION↗