Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

PV Field Performance Including Fleet and Bifacial Field Data

This presentation provides a review of two recent presentations - the 2021 PV Fleet Performance Data Initiative covered by the PVRW presentation, and bifacial system performance presented to a February DuraMAT working group. Details include degradation rate distributions from >6000 inverter channels, monthly performance vs expected, bifacial field studies of energy gain and field degradation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Time-Lapse Integration at FWU: Fluids, Rock Physics, Numerical Model Integration, and Field Data Comparison

We present the current status of time-lapse seismic integration at the Farnsworth (FWU) CO2 WAG (water-alternating-gas) EOR (Enhanced Oil Recovery) project at Ochiltree County, northwest Texas. As a potential carbon sequestration mechanism, CO2 WAG projects will be subject to some degree of monitoring and verification, either as a regulatory requirement or to qualify for economic incentives. In order to evaluate the viability of time-lapse seismic as a monitoring method the Southwest Partnership (SWP) has conducted time-lapse seismic monitoring at FWU using the 3D Vertical Seismic Profiling (VSP) method. The efficacy of seismic time-lapse depends on a number of key factors, which vary widely from one application to another. Most important among these are the thermophysical properties of the original fluid in place and the displacing fluid, followed by the petrophysical properties of the rock matrix, which together determine the effective elastic properties of the rock fluid system. We present systematic analysis of fluid thermodynamics and resulting thermophysical properties, petrophysics and rock frame elastic properties, and elastic property modeling through fluid substitution using data collected at FWU. These analyses will be framed in realistic scenarios presented by the FWU CO2 WAG development. The resulting fluid/rock physics models will be applied to output from the calibrated FWU compositional reservoir simulation model to forward model the time-lapse seismic response. Modeled results are compared with field time-lapse seismic measurements and strategies for numerical model feedback/update are discussed. While mechanical effects are neglected in the work presented here, complementary parallel studies are underway in which laboratory measurements are introduced to introduce stress dependence of matrix elastic moduli.

4D↗

Spot-based measurement of the brighter-fatter effect on a Roman Space Telescope H4RG detector and comparison with flat-field data

Here, we present the measurement and characterization of the brighter-fatter effect (BFE) on a NASA Roman Space Telescope development Teledyne H4RG-10 near-infrared detector using laboratory measurements with projected point sources. After correcting for other interpixel non-linearity effects such as classical non-linearity and inter-pixel capacitance, we quantify the magnitude of the BFE by calculating the fractional area change per electron of charge contrast. We also introduce a mathematical framework to compare our results with the BFE measured on similar devices using autocorrelations from flat-field images. We find an agreement of 18 ± 5% between the two methods. We identify potential sources of discrepancy and discuss future investigations to characterize and address them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simple and Accurate Energy-Detector-Based Transient Waveform Detection for Smart Grids: Real-World Field Data Performance

Integration of distributed energy sources, advanced meshed operation, sensors, automation, and communication networks all contribute to autonomous operations and decision-making processes utilized in the grid. Therefore, smart grid systems require sophisticated supporting structures. Furthermore, rapid detection and identification of disturbances and transients are a necessary first step towards situationally aware smart grid systems. This way, high-level monitoring is achieved and the entire system kept operational. Even though smart grid systems are unavoidably sophisticated, low-complexity algorithms need to be developed for real-time sensing on the edge and online applications to alert stakeholders in the event of an anomaly. In this study, the simplest form of anomaly detection mechanism in the absence of any a priori knowledge, namely, the energy detector (also known as radiometer in the field of wireless communications and signal processing), is investigated as a triggering mechanism, which may include automated alerts and notifications for grid anomalies. In contrast to the mainstream literature, it does not rely on transform domain tools; therefore, utmost design and implementation simplicity are attained. Performance results of the proposed energy detector algorithm are validated by real power system data obtained from the DOE/EPRI National Database of power system events and the Grid Signature Library.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Correlated Birkeland current signatures from the TRIAD and Magsat magnetic field data

Transverse magnetic disturbances associated with Birkeland currents have been measured by the Magsat and TRIAD spacecraft, whose orbits were nearly coplanar from November to mid-December, 1979. A comparison of data received when the satellites were over the TRIAD/Chatanika receiving station shows that 75% of magnetic disturbance measurements are similar in shape and magnitude, with TRIAD peak disturbances being on average 7% larger than those of Magsat. This discrepancy is lower than measurement uncertainties due to baselines and calibration. During periods of higher Kp, despite time separations of as much as 45 min, better agreement is found in the large-scale and well-defined field-aligned current signatures.

Zanetti, L. J.↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Towards a CAN IDS Based on a Neural Network Data Field Predictor

Modern vehicles contain a few controller area networks (CANs), which allow scores of on-board electronic control units (ECUs) to communicate messages critical to vehicle functions and driver safety. CAN provides a lightweight and reliable broadcast protocol but is bereft of security features. As evidenced by many recent research works, CAN exploits are possible both remotely and with direct access, fueling a growing CAN intrusion detection system (IDS) body of research. A challenge for pioneering vehicle-agnostic IDSs is that passenger vehicles' CAN message encodings are proprietary, defined and held secret by original equipment manufacturers (OEMs). Targeting detection of next-generation attacks, in which messages are sent from the expected ECU at the expected time but with malicious content, researchers are now seeking to leverage "CAN data models'', which predict future CAN messages and use prediction error to identify anomalous, hopefully malicious CAN messages. Yet, current works model CAN signals post-translation, i.e., after applying OEM-donated or reverse-engineered translations from raw data. We present initial IDS results testing deep neural networks used to predict CAN data at the bit level, targeting IDS capabilities that avoiding reverse engineering proprietary encodings. Our results suggest the method is promising for data with signals exhibiting dependence on previous or concurrent inputs.

Pawelec, Krzysztof↗

Geologic influence on induced seismicity: Constraints from potential field data in Oklahoma

Abstract Recent Oklahoma seismicity shows a regional correlation with increased wastewater injection activity, but local variations suggest that some areas are more likely to exhibit induced seismicity than others. We combine geophysical and drill hole data to map subsurface geologic features in the crystalline basement, where most earthquakes are occurring, and examine probable contributing factors. We find that most earthquakes are located where the crystalline basement is likely composed of fractured intrusive or metamorphic rock. Areas with extrusive rock or thick (>4 km) sedimentary cover exhibit little seismicity, even in high injection rate areas, similar to deep sedimentary basins in Michigan and western North Dakota. These differences in seismicity may be due to variations in permeability structure: within intrusive rocks, fluids can become narrowly focused in fractures and faults, causing an increase in local pore fluid pressure, whereas more distributed pore space in sedimentary and extrusive rocks may relax pore fluid pressure.

Shah, Anjana K.↗

Luminaire dirt depreciation (LDD): Field data from several exterior lighting projects

Luminaire dirt depreciation (LDD) data were evaluated for seven luminaires from three different project sites in Philadelphia PA, Minneapolis MN, and Yuma AZ. In each case, the luminaires were removed from the installation, carefully packaged and transported to a photometric testing laboratory, and then tested in the “as-is” or dirty condition, cleaned, and re-tested. In terms of light output, the results showed that the IES RP-36-15 method for estimating LDD was applicable to the LED luminaires evaluated. General claims of lower levels of dirt deprecation (or higher LDD values) for LED luminaires than for luminaires using conventional light sources were not supported by the test data for the LED luminaires in these three projects. While the overall measured lumen depreciation due to accumulated dirt closely matched IES estimates for LDD, the data indicated that the accumulated dirt on the luminaires dramatically altered the luminous intensity distribution of the luminaires, with reductions in intensity of more than 25% at peak angles. These effects on luminous intensity distribution are not accounted for in IES LDD estimates.

Davis, Robert G.↗

Discrete-Direct Model Calibration and Uncertainty Propagation Method Confirmed on Multi-Parameter Plasticity Model Calibrated to Sparse Random Field Data

A discrete direct (DD) model calibration and uncertainty propagation approach is explained and demonstrated on a 4-parameter Johnson-Cook (J-C) strain-rate dependent material strength model for an aluminum alloy. The methodology's performance is characterized in many trials involving four random realizations of strain-rate dependent material-test data curves per trial, drawn from a large synthetic population. The J-C model is calibrated to particular combinations of the data curves to obtain calibration parameter sets which are then propagated to “Can Crush” structural model predictions to produce samples of predicted response variability. These are processed with appropriate sparse-sample uncertainty quantification (UQ) methods to estimate various statistics of response with an appropriate level of conservatism. This is tested on 16 output quantities (von Mises stresses and equivalent plastic strains) and it is shown that important statistics of the true variabilities of the 16 quantities are bounded with a high success rate that is reasonably predictable and controllable. The DD approach has several advantages over other calibration-UQ approaches like Bayesian inference for capturing and utilizing the information obtained from typically small numbers of replicate experiments in model calibration situations—especially when sparse replicate functional data are involved like force–displacement curves from material tests. The DD methodology is straightforward and efficient for calibration and propagation problems involving aleatory and epistemic uncertainties in calibration experiments, models, and procedures.

42 ENGINEERING↗

Loss Factors for Small Distributed Wind Turbines Based on Field Data in the United States

While wind energy production loss due to unavailability, environmental impacts, curtailment, and other causes has been studied and characterized at the utility-scale wind farm level, observation-based characterization of project loss is lacking for distributed wind energy, particularly for projects involving small wind turbines. Contemporary tools and research that support pre-construction distributed wind energy characterization present a wide range of default loss factors to convert gross energy estimates to net: 7-18%. We hypothesize that we can use generation observations from operational distributed wind projects to develop more accurate representations of loss. Using a density-based filtering technique on distributed wind power generation timeseries, we determine periods of typical performance and use them with regression algorithms in a measure-correlate-predict fashion to simulate what the generation would have been during periods of atypical or unreported performance. From there, the actual versus predicted generation leads to the establishment of observation-informed loss factors (median = 17%) for small, single turbine installation distributed wind projects.

17 WIND ENERGY↗