Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flight Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Note: Optical and electronic design of an amplitude-modulated continuous-wave laser scanner for high-accuracy distance measurement

To utilize a time-of-flight-based laser scanner as a distance measurement sensor, the measurable distance and accuracy are the most important performance parameters to consider. For these purposes, the optical system and electronic signal processing of the laser scanner should be optimally designed in order to reduce a distance error caused by the optical crosstalk and wide dynamic range input. Optical system design for removing optical crosstalk problem is proposed in this work. Intensity control is also considered to solve the problem of a phase-shift variation in the signal processing circuit caused by object reflectivity. The experimental results for optical system and signal processing design are performed using 3D measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proteomic profiling of brain cortex tissues in a Tau transgenic mouse model of Alzheimer's disease

Highlights: Black-Right-Pointing-Pointer A transgenic mouse model expressing NSE-htau23 was used. Black-Right-Pointing-Pointer 2D-gel electrophoresis to analyze the cortex proteins of transgenic mice was used. Black-Right-Pointing-Pointer Differentially expressed spots in different stages of AD were identified. Black-Right-Pointing-Pointer GSTP1 and CAII were downregulated with the progression of AD. Black-Right-Pointing-Pointer SCRN1 and ATP6VE1 were up regulated and down regulated differentially. -- Abstract: Alzheimer's disease (AD) involves regionalized neuronal death, synaptic loss, and an accumulation of intracellular neurofibrillary tangles and extracellular senile plaques. Although there have been numerous studies on tau proteins and AD in various stages of neurodegenerative disease pathology, the relationship between tau and AD is not yet fully understood. A transgenic mouse model expressing neuron-specific enolase (NSE)-controlled human wild-type tau (NSE-htau23), which displays some of the typical Alzheimer-associated pathological features, was used to analyze the brain proteome associated with tau tangle deposition. Two-dimensional electrophoresis was performed to compare the cortex proteins of transgenic mice (6- and 12-month-old) with those of control mice. Differentially expressed spots in different stages of AD were identified with ESI-Q-TOF (electrospray ionization quadruple time-of-flight) mass spectrometry and liquid chromatography/tandem mass spectrometry. Among the identified proteins, glutathione S-transferase P 1 (GSTP1) and carbonic anhydrase II (CAII) were down-regulated with the progression of AD, and secerin-1 (SCRN1) and V-type proton ATPase subunit E 1 (ATP6VE1) were up-regulated only in the early stages, and down-regulated in the later stages of AD. The proteins, which were further confirmed by RT-PCR at the mRNA level and with western blotting at the protein level, are expected to be good candidates as drug targets for AD. The study of up- and down-regulation of proteins during the progression of AD helps to explain the mechanisms associated with neuronal degeneration in AD.

60 APPLIED LIFE SCIENCES↗

Identification of serum biomarkers for occupational medicamentosa-like dermatitis induced by trichloroethylene using mass spectrometry

Occupational medicamentosa-like dermatitis induced by trichloroethylene (OMLDT) is an autoimmune disease and it has become a serious occupational health hazard. In the present study, we collected fasting blood samples from patients with OMLDT (n = 18) and healthy volunteers (n = 33) to explore serum peptidome patterns. Peptides in sera were purified using weak cation exchange magnetic beads (MB-WCX), and analyzed by matrix-assisted laser desorption ionization time-of-flight-mass spectrometry (MALDI-TOF-MS) and ClinProTools bioinformatics software. The intensities of thirty protein/peptide peaks were significantly different between the healthy control and OMLDT patients. A pattern of three peaks (m/z 2106.3, 2134.5, and 3263.67) was selected for supervised neural network (SNN) model building to separate the OMLDT patients from the healthy controls with a sensitivity of 95.5% and a specificity of 73.8%. Furthermore, two peptide peaks of m/z 4091.61 and 4281.69 were identified as fragments of ATP-binding cassette transporter family A member 12 (ABCA12), and cationic trypsinogen (PRRS1), respectively. Our findings not only show that specific proteomic fingerprints in the sera of OMLDT patients can be served as a differentiated tool of OMLDT patients with high sensitivity and high specificity, but also reveal the novel correlation between OMLDT with ABC transports and PRRS1, which will be of potential value for clinical and mechanistic studies of OMLDT. - Highlights: • Identify 30 differential protein/peptide peaks between OMLDT and healthy control • The test sensitivity and test specificity were 95.5% and 73.8%, respectively. • ABCA12 and PRSS1 were identified as potential biomarkers in OMLDT patients.

60 APPLIED LIFE SCIENCES↗

Apolipoprotein C-II Is a Potential Serum Biomarker as a Prognostic Factor of Locally Advanced Cervical Cancer After Chemoradiation Therapy

Purpose: To determine pretreatment serum protein levels for generally applicable measurement to predict chemoradiation treatment outcomes in patients with locally advanced squamous cell cervical carcinoma (CC). Methods and Materials: In a screening study, measurements were conducted twice. At first, 6 serum samples from CC patients (3 with no evidence of disease [NED] and 3 with cancer-caused death [CD]) and 2 from healthy controls were tested. Next, 12 serum samples from different CC patients (8 NED, 4 CD) and 4 from healthy controls were examined. Subsequently, 28 different CC patients (18 NED, 10 CD) and 9 controls were analyzed in the validation study. Protein chips were treated with the sample sera, and the serum protein pattern was detected by surface-enhanced laser desorption and ionization–time-of-flight mass spectrometry (SELDI-TOF MS). Then, single MS-based peptide mass fingerprinting (PMF) and tandem MS (MS/MS)-based peptide/protein identification methods, were used to identify protein corresponding to the detected peak. And then, turbidimetric assay was used to measure the levels of a protein that indicated the best match with this peptide peak. Results: The same peak 8918 m/z was identified in both screening studies. Neither the screening study nor the validation study had significant differences in the appearance of this peak in the controls and NED. However, the intensity of the peak in CD was significantly lower than that of controls and NED in both pilot studies (P=.02, P=.04) and validation study (P=.01, P=.001). The protein indicated the best match with this peptide peak at 8918 m/z was identified as apolipoprotein C-II (ApoC-II) using PMF and MS/MS methods. Turbidimetric assay showed that the mean serum levels of ApoC-II tended to decrease in CD group when compared with NED group (P=.078). Conclusion: ApoC-II could be used as a biomarker for detection in predicting and estimating the radiation treatment outcome of patients with CC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental determination of precision, resolution, accuracy and trueness of time-of-flight neutron diffraction strain measurements

We discuss a simple statistical analysis which yields the precision, resolution, accuracy and trueness of diffraction-based lattice strain measurements. The procedure consists of measuring the thermal expansion induced in each component of an ideal, non-reacting, two-component, crystalline powder sample in situ. One component, with a high coefficient of thermal expansion (CTE), serves as an internal thermometer. The quantities of interest are obtained by determining the smallest, statistically significant, thermal lattice strain which can be detected through diffraction analysis in the second, low CTE, component in response to controlled temperature changes. This procedure also provides a robust check of the alignment of the diffraction system and is able to reveal the presence of systematic errors. The application of this technique to a time-of-flight engineering diffractometer/strain scanner is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Videos, photos, and AI-derived grain size data associated with “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the manuscript “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization” under review. This data package includes five data types: 1) raw photos and videos from drone survey and walking smartphone surveys; 2) images derived from raw videos; 3) manual labeling of reference scales; 4) metadata for all images and photo resolution derived from artificial intelligence (AI) models or manual labels, 5) grain size data obtained from AI models for all photos, 6) metadata and grain size data after quality control, 7) summaries of sample efficiency for all data, and 8) computational fluid dynamics (CFD) data used to support hydro-biogeochemical (HBGC) parameter estimation. Such data is used to 1) demonstrate significant improvements in accuracy, efficiency, and quality control for grain size data collection with the help of AI models, 2) study the spatial heterogeneity of grain size and observation reproducibility based on tens of thousands of data points generated by the AI models, and 3) evaluate the impacts of grain size heterogeneity on key HBGC parameters across sediment-to-reach and hourly-to-yearly scales. In particular, the data package contains 116 folders and 179696 files. The files include 41 videos in .mov format, 64047 photos in .jpg format, 13541 video-derived photos in .png format, 12747 segmentation mask data in .tif format, 12747 segmentation data in .json format, 24771 .csv files that with metadata and grain size for each individual photo as well as water depth and velocity data from CFD and observation, 51791 .txt files of raw AI predicted labels, and 11 flight record data in .srt format. The summary for all metadata and grain size statistics information is included in “Scales_V3_NG.csv” and “Statistics_V3_NG.csv”. The summary for data that pass data quality control (QC) level 0-2 is included in “QCStatistics_V3_NG.csv”. The QC level 0 represents photos whose photo resolution is positive, excluding photos that miss reference scale. The QC level 1 means reference scale circularity uncertainty is less than 5% for smartphone images while representing photo resolution is larger than 0.44 mm/pixel for drone images. The QC level 2 means excluding photos whose grain number is less than 100, a minimum number of grains recommended by classic literature. The summary for each video’s name, length, frame rates, survey area, grain number, survey efficiency, etc. can be found in “QCSummary_V3_NG.csv”. The summary for site name, GPS coordinates, and number of images at each site can be found in “SitesSummary_V3_*.csv” files. Overall computational efficiency summary is reported in Table 4 of accompanying manuscript. Additionally, the nitrate concentration data used in this work was downloaded from an existing dataset published on ESS-DIVE (Boat-Dragged Sensor Hanford Reach.csv; Conner A. et al., 2020). We thank the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, Cowiche Canyon Conservatory, Port of Benton, and the Confederated Tribes and Bands of the Yakama Nation for access to field locations where the data were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate data collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Synthesis and Purification of Homogeneous Lipid-Based Peptide Nanocarriers by Overcoming Phospholipid Ester Hydrolysis

Despite the therapeutic promise of phospholipid-based nanocarriers, a major obstacle to their widespread clinical translation is a susceptibility to fatty acid ester hydrolysis, leading to lack of quality control and inconsistencies in self-assembly formulations. Using electrospray ionization mass spectrometry fragmentation in combination with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, we have demonstrated a method to detect hydrolysis of one or both of the fatty acid esters in a PEGylated phospholipid, DSPE-PEG, in conditions commonly applied during nanocarrier production. Because such carriers are increasingly being used to deliver peptide-based therapeutics, we further investigated the hydrolysis of phospholipid esters in conditions used for solid-phase peptide synthesis and high-performance liquid chromatography of peptides. We ultimately detail a synthetic strategy to reliably produce pure phospholipid–peptide bioconjugates (peptide amphiphiles), while avoiding unintended or unnoticed hydrolyzed byproducts that could lead to polymorphic nanotherapeutics with dampened therapeutic efficacy. We believe that such an approach could help standardize phospholipid–peptide-based therapeutic development, testing, and clinical translation.

60 APPLIED LIFE SCIENCES↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

THE COSMIC INFRARED BACKGROUND EXPERIMENT (CIBER): THE LOW RESOLUTION SPECTROMETER

Absolute spectrophotometric measurements of diffuse radiation at 1 {mu}m to 2 {mu}m are crucial to our understanding of the radiative content of the universe from nucleosynthesis since the epoch of reionization, the composition and structure of the zodiacal dust cloud in our solar system, and the diffuse galactic light arising from starlight scattered by interstellar dust. The Low Resolution Spectrometer (LRS) on the rocket-borne Cosmic Infrared Background Experiment is a {lambda}/{Delta}{lambda} {approx} 15-30 absolute spectrophotometer designed to make precision measurements of the absolute near-infrared sky brightness between 0.75 {mu}m <{lambda} < 2.1 {mu}m. This paper presents the optical, mechanical, and electronic design of the LRS, as well as the ground testing, characterization, and calibration measurements undertaken before flight to verify its performance. The LRS is shown to work to specifications, achieving the necessary optical and sensitivity performance. We describe our understanding and control of sources of systematic error for absolute photometry of the near-infrared extragalactic background light.

79 ASTRONOMY AND ASTROPHYSICS↗

Addressing the Amorphous Content Issue in Quantitative Phase Analysis: The Certification of NIST Standard Reference Material 676a

A non-diffracting surface layer exists at any boundary of a crystal and can comprise a mass fraction of several percent in a finely divided solid. This has led to the long-standing issue of amorphous content in standards for quantitative phase analysis (QPA). NIST standard reference material (SRM) 676a is a corundum ({alpha}-Al{sub 2}O{sub 3}) powder, certified with respect to phase purity for use as an internal standard in powder diffraction QPA. The amorphous content of SRM 676a is determined by comparing diffraction data from mixtures with samples of silicon powders that were engineered to vary their specific surface area. Under the (supported) assumption that the thickness of an amorphous surface layer on Si was invariant, this provided a method to control the crystalline/amorphous ratio of the silicon components of 50/50 weight mixtures of SRM 676a with silicon. Powder diffraction experiments utilizing neutron time-of-flight and 25 keV and 67 keV X-ray energies quantified the crystalline phase fractions from a series of specimens. Results from Rietveld analyses, which included a model for extinction effects in the silicon, of these data were extrapolated to the limit of zero amorphous content of the Si powder. The certified phase purity of SRM 676a is 99.02% {+-} 1.11% (95% confidence interval). This novel certification method permits quantification of amorphous content for any sample of interest, by spiking with SRM 676a.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Ce 4 + in the scintillation mechanism of codoped Gd 3 Ga 3 Al 2 O 12 : Ce

To control the time-response performance of widely used cerium-activated scintillators in cutting-edge medical-imaging devices, such as time-of-flight positron-emission tomography, a comprehensive understanding of the role of Ce valence states, especially stable Ce 4+ , in the scintillation mechanism is essential. However, despite some progress made recently, an understanding of the physical processes involving Ce 4+ is still lacking. The aim of this work is to clarify the role of Ce 4+ in scintillators by studying Ca 2+ codoped Gd 3 Ga 3 Al 2 O1 2 ∶Ce (GGAG∶Ce). By using a combination of optical absorption spectra and x-ray absorption near-edge spectroscopies, the correlation between Ca 2+ codoping content and the Ce 4+ fraction is seen. The energy-level diagrams of Ce 3+ and Ce 4+ in the Gd 3 Ga 3 Al 2 O 12 host are established by using theoretical and experimental methods, which indicate a higher position of the 5d 1 state of Ce 4+ in the forbidden gap in comparison to that of Ce 3+ . Underlying reasons for the decay-time acceleration resulting from Ca 2+ codoping are revealed, and the physical processes of the Ce 4+ -emission model are proposed and further demonstrated by temperature-dependent radioluminescence spectra under x-ray excitation.

Wu, Yuntao↗

Measurement of Beam Energy in the Fermilab&#x27;s Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

Measurement of Beam Energy in the Fermilab&#x27;s Linac taken at the transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where 𝐻− particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped. of the extra electrons to become protons. The Booster requires stable beam energy at injection. The Linac extraction energy tuning has been performed using two Beam Velocity Monitors (a.k.a Griffin detectors) to maintain stable relative energy between the Booster and the Linac. Our goal is to control the Linac energy parameters using Machine Learning techniques to increase reliability and quality of beam delivered from Linac. The first step is to understand the data from the Linac extraction diagnostics; and develop reliable, accurate methods for energy measurement and control before implementing machine learning. There were two methods of energy measurement implemented, and the results of these are compared. The first method was time of flight measurements using the Phase probes inside B eam Position Monitors (BPM) that provide the beam’s phase of arrival data. The second method used the relation between beam position data from the BPMs and dispersion values from the 400MeV MAD-X model to calculate momentum variation. The results of these two energy measurement methods compare well as the Linac energy is varied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-resolution time-of-flight mass spectrometry fingerprinting of metabolites from cecum and distal colon contents of rats fed resistant starch

Time-of-flight mass spectrometry along with statistical analysis was utilized to study metabolic profiles among rats fed resistant starch (RS) diets. Fischer 344 rats were fed four starch diets consisting of 55 % (w/w, dbs) starch. A control starch diet consisting of corn starch was compared against three RS diets. The RS diets were high-amylose corn starch (HA7), HA7 chemically modified with octenyl succinic anhydride, and stearic-acid-complexed HA7 starch. A subgroup received antibiotic treatment to determine if perturbations in the gut microbiome were long lasting. A second subgroup was treated with azoxymethane (AOM), a carcinogen. At the end of the 8-week study, cecal and distal colon content samples were collected from the sacrificed rats. Metabolites were extracted from cecal and distal colon samples into acetonitrile. The extracts were then analyzed on an accurate-mass time-of-flight mass spectrometer to obtain their metabolic profile. The data were analyzed using partial least-squares discriminant analysis (PLS-DA). The PLS-DA analysis utilized a training set and verification set to classify samples within diet and treatment groups. PLS-DA could reliably differentiate the diet treatments for both cecal and distal colon samples. The PLS-DA analyses of the antibiotic and no antibiotic-treated subgroups were well classified for cecal samples and modestly separated for distal colon samples. PLS-DA analysis had limited success separating distal colon samples for rats given AOM from those not treated; the cecal samples from AOM had very poor classification. Mass spectrometry profiling coupled with PLS-DA can readily classify metabolite differences among rats given RS diets.

36 MATERIALS SCIENCE↗

Mass Spectrometry and Fourier Transform Infrared Spectroscopy for Analysis of Biological Materials

Time-of-flight mass spectrometry along with statistical analysis was utilized to study metabolic profiles among rats fed resistant starch (RS) diets. Fischer 344 rats were fed four starch diets consisting of 55% (w/w, dbs) starch. A control starch diet consisting of corn starch was compared against three RS diets. The RS diets were high-amylose corn starch (HA7), HA7 chemically modified with octenyl succinic anhydride, and stearic-acid-complexed HA7 starch. A subgroup received antibiotic treatment to determine if perturbations in the gut microbiome were long lasting. A second subgroup was treated with azoxymethane (AOM), a carcinogen. At the end of the eight week study, cecal and distal-colon contents samples were collected from the sacrificed rats. Metabolites were extracted from cecal and distal colon samples into acetonitrile. The extracts were then analyzed on an accurate-mass time-of-flight mass spectrometer to obtain their metabolic profile. The data were analyzed using partial least-squares discriminant analysis (PLS-DA). The PLS-DA analysis utilized a training set and verification set to classify samples within diet and treatment groups. PLS-DA could reliably differentiate the diet treatments for both cecal and distal colon samples. The PLS-DA analyses of the antibiotic and no antibiotic treated subgroups were well classified for cecal samples and modestly separated for distal-colon samples. PLS-DA analysis had limited success separating distal colon samples for rats given AOM from those not treated; the cecal samples from AOM had very poor classification. Mass spectrometry profiling coupled with PLS-DA can readily classify metabolite differences among rats given RS diets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensing and Sampling of Trace Contaminations by a Dexterous Hexrotor UAV at Nuclear Facilities - 18600

Safe and efficient cleanups are a priority for decontamination and decommissioning of nuclear facilities. The contaminations of byproducts and wastes in such nuclear facilities pose a serious problems while decommissioning, to both the operators and public. Sensing these contaminations and cleaning them is an essential part of the safety procedures. The contaminations might range from low-energy to high-energy byproducts. Sensing these byproducts would require contact based or non-contact based sensing, based on its energy levels. Byproducts such as americium, are low-energy which makes it difficult to sense and sample without contact. Therefore, the workers need to physically swab the surfaces to collect the samples of these contaminations. These tasks pose a great danger for the safety of the human workers which includes the risk to reach greater heights, exposure to the radiation and sampling the entire building. A robotic solution is much more desirable in these cases, where the worker can safely handle the contaminations from a safe area. Use of robotic technologies inside these hazardous environments ensures the safety and enhances the performance. The more suitable robotic solution for reaching great heights and covering large areas of nuclear facilities, are aerial vehicles. Multi-rotor unmanned aerial vehicle (UAV) are chosen for their ability to hover at a position and also fly around in confined spaces. Quadrotors are a common choice of multi-rotor UAVs both research and industry because of its ease to fly and commercial availability. For the applications during the cleanups we need the UAV to not only hover and fly in confined spaces, but also interact with the physical world. Despite of quadrotor's advantages, they are not a best suit as they can't interact with the physical world. The tasks involving physical interactions would require the UAV to apply arbitrary forces and torques in all six degrees of freedom (DOF). As quadrotors are under-actuated and non-holonomic in motion, they cannot exert all the required forces. At Collaborative Robotics Lab, Purdue University, we developed a novel multi-rotor UAV solution, Dexterous Hexrotor, which can exert arbitrary forces and torques in all six DOF, independently and instantaneously. This enables the UAV platform to quickly respond to the external disturbances and precisely hold its position during the mission. The Dexterous Hexrotor serves as a robotic tool for the workers to perform sensing and sampling during the cleanups. Workers can operate Dexterous Hexrotor manually and/or semi-autonomously with human intervention. Manual control requires the worker to fly the Dexterous Hexrotor using a remote control. So the workers should possess knowledge on flying the UAV and to perform physical interaction. A semiautonomous Dexterous Hexrotor requires human input to some extent and requires very less knowledge of flying. The autonomy is designed to operate in flight mode and sampling mode. In flight mode, Dexterous Hexrotor takes off from a 'safe' area, reaches the desired altitude, and fly autonomously towards a sampling point. This sampling point is the target position specified on the 2D reference map. This mode also includes navigation towards the sampling point, avoiding the obstacles in the constrained environment. After reaching a stopping point, Dexterous Hexrotor waits for the human input for a target location to swab and collect samples. The Dexterous Hexrotor is now in sampling mode and waits for the human input. The human operator selects the swabbing location through the live streaming video from onboard camera. Through visual servoing, aided by the map, the UAV will move closer towards the target position. It then transitions to the impact control scheme to perform physical interaction with the wall and collects samples. Once the sample is collected, it autonomously returns back to the takeoff position in 'safe' area for the analysis by mass spectrometry. In this paper, we majorly focus on the physical interaction strategy and the required components which enables the autonomy. Decommissioning of nuclear facilities requires decontamination inside the entire buildings. Decontamination of nuclear facilities involves sensing and sampling the huge buildings, long shafts, etc. Sampling the entire facility is not possible due to the limitation in Dexterous Hexrotor's flight time. But this can be achieved by using a swarm of Dexterous Hexrotors to cover larger areas. The onboard robotic arm can be designed based on the applications such as cleaning, applying sealants, etc. The modularity of the design allows us to switch components as per the requirements of the task. These kind of robotic solutions functioning as tools for the workers, aims to make the work environment safer and playful. (authors)

42 ENGINEERING↗

Autonomous aerial flight path inspection using advanced manufacturing techniques

Robotic systems have shown capabilities to perform inspection tasks in dangerous and difficult-to-access environments, such as those found in different components of power plants. However, most of the current robotic inspection technology is designed for specific components. Aerial robots, commonly termed as Drones, have raised an option to inspect a wider range of structural components. Nevertheless, current aerial inspecting technology still relies on a human pilot with limited line of sight, field of view and a reduced perception as the drone flies away, which prevents performing close-quarter inspection in intricate, structurally complex and GPS-denied environments. This work introduces offline inspection path generation methods based on robotics-integrated to manufacturing techniques. One method uses computer-aided manufacturing (CAM) techniques and the other an additive manufacturing (AM) approach to generate the flight path. That is to say, the drone would fly along the path described by a 3D (Three Dimensional) printer’s extruder or a CNC (Computer Numerical Control) machining tool, enabling to fly very close the structure even in physical structures with a complex geometry. Once the trajectories are generated, they are introduced for its validation in the Gazebo robotics simulator. Simulation results demonstrate the proper performance of the method and confirm that this approach can be used for close inspection of structural components.

42 ENGINEERING↗