Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Two-Phase Flow Simulations In a Natural Rock Fracture using the VOF Method

Standard models of two-phase flow in porous media have been shown to exhibit several shortcomings that might be partially overcome with a recently developed model based on thermodynamic principles (Hassanizadeh and Gray, 1990). This alternative two-phase flow model contains a set of new and non-standard parameters, including specific interfacial area. By incorporating interfacial area production, destruction, and propagation into functional relationships that describe the capillary pressure and saturation, a more physical model has been developed. Niessner and Hassanizadeh (2008) have examined this model numerically and have shown that the model captures saturation hysteresis with drainage/imbibition cycles. Several static experimental studies have been performed to examine the validity of this new thermodynamically based approach; these allow the determination of static parameters of the model. To date, no experimental studies have obtained information about the dynamic parameters required for the model. A new experimental porous flow cell has been constructed using stereolithography to study two-phase flow phenomena (Crandall et al. 2008). A novel image analysis tool was developed for an examination of the evolution of flow patterns during displacement experiments (Crandall et al. 2009). This analysis tool enables the direct quantification of interfacial area between fluids by matching known geometrical properties of the constructed flow cell with locations identified as interfaces from images of flowing fluids. Numerous images were obtained from two-phase experiments within the flow cell. The dynamic evolution of the fluid distribution and the fluid-fluid interface locations were determined by analyzing these images. In this paper, we give a brief introduction to the thermodynamically based two-phase flow model, review the properties of the stereolithography flow cell, and show how the image analysis procedure has been used to obtain dynamic parameters for the numerical model. These parameters include production/destruction of interfacial area as a function of saturation and capillary pressure. Our preliminary results for primary drainage in porous media show that the specific interfacial area increased linearly with increasing gas saturation until breakthrough of the displacing gas into the exit manifold occurred.

54 ENVIRONMENTAL SCIENCES↗

Direct, Dynamic Measurement of Interfacial Area within Porous Media

Standard models of two-phase flow in porous media have been shown to exhibit several shortcomings that might be partially overcome with a recently developed model based on thermodynamic principles (Hassanizadeh and Gray, 1990). This alternative two-phase flow model contains a set of new and non-standard parameters, including specific interfacial area. By incorporating interfacial area production, destruction, and propagation into functional relationships that describe the capillary pressure and saturation, a more physical model has been developed. Niessner and Hassanizadeh (2008) have examined this model numerically and have shown that the model captures saturation hysteresis with drainage/imbibition cycles. Several static experimental studies have been performed to examine the validity of this new thermodynamically based approach; these allow the determination of static parameters of the model. To date, no experimental studies have obtained information about the dynamic parameters required for the model. A new experimental porous flow cell has been constructed using stereolithography to study two-phase flow phenomena (Crandall et al. 2008). A novel image analysis tool was developed for an examination of the evolution of flow patterns during displacement experiments (Crandall et al. 2009). This analysis tool enables the direct quantification of interfacial area between fluids by matching known geometrical properties of the constructed flow cell with locations identified as interfaces from images of flowing fluids. Numerous images were obtained from two-phase experiments within the flow cell. The dynamic evolution of the fluid distribution and the fluid-fluid interface locations were determined by analyzing these images. In this paper, we give a brief introduction to the thermodynamically based two-phase flow model, review the properties of the stereolithography flow cell, and show how the image analysis procedure has been used to obtain dynamic parameters for the numerical model. These parameters include production/destruction of interfacial area as a function of saturation and capillary pressure. Our preliminary results for primary drainage in porous media show that the specific interfacial area increased linearly with increasing gas saturation until breakthrough of the displacing gas into the exit manifold occurred.

54 ENVIRONMENTAL SCIENCES↗

Experimentally Measured Interfacial Area during Gas Injection into Saturated Porous Media: An Air Sparging Analogy

The amount of interfacial area (awn) between air and subsurface liquids during air-sparging can limit the rate of site remediation. Lateral movement within porous media could be encountered during air-sparging operations when air moves along the bottom of a low-permeability lens. This study was conducted to directly measure the amount of awn between air and water flowing within a bench-scale porous flow cell during the lateral movement of air along the upper edge of the cell during air injections into an initially water-saturated flow cell. Four different cell orientations were used to evaluate the effect of air injection rates and porous media geometries on the amount of awn between fluids. Air was injected at flow rates that varied by three orders of magnitude, and for each flow cellover this range of injection rates little change in awn was noted. A wider variation in awn was observed when air moved through different regions for the different flow cell orientations. These results are in good agreement with the experimental findings of Waduge et al. (2007), who performed experiments in a larger sand-pack flow cell, and determined that air-sparging efficiency is nearly independent of flow rate but highly dependent on the porous structure. By directly measuring the awn, and showing that awn does not vary greatly with changes in injection rate, we show that the lack of improvement to remediation rates is because there is a weak dependence of the awn on the air injection rate.

58 GEOSCIENCES↗

Alkaline manganese redox flow battery with inhibitor

A redox flow battery includes a redox flow cell and a supply and storage system external of the redox flow cell. The supply and storage system includes first and second electrolytes for circulation through the redox flow cell. The first electrolyte is a liquid electrolyte having electrochemically active manganese species with multiple, reversible oxidation states in the redox flow cell. The electrochemically active manganese species may undergo reactions that cause precipitation of manganese oxide solids. The first electrolyte includes an inhibitor that limits the self-discharge reactions. The inhibitor includes an oxoanion compound.

Davenport, Timothy↗

Real-Time XANES Measurement of Se Reduction by Zerovalent Iron in a Flow-through Cell, and Accompanying Se Isotope Measurements

An anoxic flow-through cell experiment was conducted to examine mechanisms controlling the real-time reduction of selenate (Se(VI)) by zerovalent iron (ZVI), which is commonly used in permeable reactive barriers to treat dissolved contaminants including Se(VI). Changes in selenium (Se) isotope composition were examined by increasing the influent Se concentration over time, thus changing the proportion of Se removed from solution. At the conclusion of the experiment, an anoxic Se-free solution was pumped through the cell to assess the stability of the reaction products. At all stages, X-ray absorption data were obtained from the solid phase and Se isotope data from the aqueous phase. Reduced Se in the form of adsorbed Se(IV), Fe 2 SeO 4 , Se(0), and iron selenides accumulated on the ZVI over time. A linear regression function was fit to the $δ$ 82/76 Se values of the effluent, yielding an isotopic separation of 9.6‰. A Rayleigh curve was fit to the isotope data from the effluent samples collected during the rinse stage with an effective fractionation of 2.4‰. The results from this experiment can be used to elucidate the effect of multiple concurrent mechanisms on Se isotope behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling Carbon Oxidation and Surface Recession in Direct-Simulation Monte Carlo Code, SPARTA

Ablative thermal protection system (TPS) materials for spacecraft are composites that are often made out of carbon-based reinforcement and a polymeric matrix. They endure high-temperature oxidation and surface recession when re-entering Earth’s atmosphere. Ablation is the result of many coupled and competing thermal, mechanical, and chemical phenomena, and it is difficult to isolate the role of each on the overall degradation of the TPS. Here we develop an ablation model for material recession coupled explicitly to finite rate carbon oxidation in complex microstructures. In this work, Stochastic PArallel Rarified-gas Time-accurate Analyzer (SPARTA), a direct-simulation Monte Carlo (DSMC) code, is modified to allow oxidation-driven ablation of implicitly defined carbon surfaces. In SPARTA, implicit surfaces are generated from the grid corner point values via a marching cubes algorithm, therefore creating a new set of surface elements every time ablation is performed. The finite-rate oxidation model developed by Gopalan et. al, was adapted to tally surface reactions and other surface data on a per-grid cell basis. The ablation functionality was also adjusted so once the reactions have occurred, the number of reactions leading to CO formation can be converted to corner point reduction values; therefore, carbon removal is directly proportional to surface recession. We also develop robust algorithms which handle the evolution of the flow cells and solid material regions, including split cells (flow cell divided in two by a solid surface). Finally, we demonstrate our implicit chemistry model for 2D and 3D geometries by producing reaction statistics and detailed visualization of oxidation-induced material recession at the microscale.

V Arias↗

Oxygen-Mass-Flow Calibration Cell

Proposed calibration standard for mass flow rate of oxygen based on conduction of oxygen ions through solid electrolyte membrane made of zirconia and heated to temperature of 1,000 degrees C. Flow of oxygen ions proportional to applied electric current. Unaffected by variations in temperature and pressure, and requires no measurement of volume. Calibration cell based on concept used to calibrate variety of medical and scientific instruments required to operate with precise rates of flow of oxygen.

Martin, Robert E.↗

Amphiphilic mediated sample preparation for micro-flow cytometry

A flow cytometer includes a flow cell for detecting the sample, an oil phase in the flow cell, a water phase in the flow cell, an oil-water interface between the oil phase and the water phase, a detector for detecting the sample at the oil-water interface, and a hydrophobic unit operatively connected to the sample. The hydrophobic unit is attached to the sample. The sample and the hydrophobic unit are placed in an oil and water combination. The sample is detected at the interface between the oil phase and the water phase.

47 OTHER INSTRUMENTATION↗

Modeling the hydrodynamic and electrochemical efficiency of semi-solid flow batteries

A mathematical model of flow cell operation incorporating hydrodynamic and electrochemical effects in three dimensions is developed. The model and resulting simulations apply to recently demonstrated high energy-density semi-solid flow cells. In particular, state of charge gradients that develop during low flow rate operation and their effects on the spatial non-uniformity of current density within flow cells are quantified. A one-dimensional scaling model is also developed and compared to the full three-dimensional simulation. The models are used to demonstrate the impact of the choice of electrochemical couple on flow cell performance. For semi-solid flow electrodes, which can use solid active materials with a wide variety of voltage-capacity responses, we find that cell efficiency is maximized for electrochemical couples that have a relatively flat voltage vs. capacity curve, operated under slow flow conditions. For example, in flow electrodes limited by macroscopic charge transport, an LiFePO4-based system requires one-third the polarization to reach the same cycling rate as an LiCoO2-based system, all else being equal. Our conclusions are generally applicable to high energy density flow battery systems, in which flow rates can be comparatively low for a given required power. (C) 2012 Elsevier Ltd. All rights reserved.

Brunini, VE↗

In situ SEM and ToF-SIMS analysis of IgG conjugated gold nanoparticles at aqueous surfaces

In this study, we report new results of in situ study of 5 nm goat anti-mouse IgG gold nanoparticles in a novel portable vacuum compatible microfluidic device using scanning electron microscope (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The unique feature of the liquid flow cell is that the detection window is open to the vacuum allowing direct probing of the liquid surface. The flow cell is composed of a silicon nitride (SiN) membrane and polydimethylsiloxane (PDMS), and it is fully compatible with vacuum operations for surface analysis. The aperture can be drilled through the 100 nm SiN membrane using a focused ion beam. Characteristic signals of the conjugated gold nanoparticles were successfully observed through the aperture by both energy-dispersive X-ray spectroscopy (EDX) in SEM and ToF-SIMS. Comparison was also made among wet samples, dry samples, and liquid sample in the flow cell using SEM/EDX. Stronger gold signal can be observed in our novel portable device by SEM/EDX compared with the wet or dry samples, respectively. Our results indicate that analyses of the nanoparticle components are better made in their native liquid environment. This is made possible using our unique microfluidic flow cell.

aqueous surface↗

Feasibility study: Atmospheric general circulation experiment, volume 1

The atmospheric general circulation experiment (AGCE) uses a rotating fluid flow cell assembly. The key technical areas affecting the feasibility of the design and operation of the AGCE are investigated. The areas investigated include materials for the flow cell assembly, thermal design, high voltage power supply design, effective retrieval and handling of experiment data and apparatus configuration. Several materials, DMSO and m-tolunitrile, were selected as candidate fluids for the flow cell principally for their high dielectric constant which permits the high voltage power supply design to be held to 15 kV and still simulate terrestrial gravity. Achievement of a low dissipation factor in the fluid to minimize internal heating from the applied electrical field depends strongly on purification and handling procedures. The use of sapphire as the outer hemisphere for the flow cell provides excellent viewing conditions without a significant impact on attaining the desired thermal gradients. Birefringent effects from sapphire can be held to acceptably low limits. Visualization of flow fluid is achieved through the motion of a dot matrix formed by photochromic dyes. Two dyes found compatible with the candidate fluids are spiropyran and triarylmethane. The observation of the dot motion is accomplished using a flying spot scanner.

Homsey, R. J.↗

Observed Properties of Giant Cells

The existence of Giant Cells has been suggested by both theory and observation for over 45 years. We have tracked the motions of supergranules in SDO/HMI Doppler velocity data and find larger (Giant Cell) flows that persist for months. The flows in these cells are clockwise around centers of divergence in the north and counter-clockwise in the south. Equatorward flows are correlated with prograde flows - giving the transport of angular momentum toward the equator that is needed to maintain the Sun's rapid equatorial rotation. The cells are most pronounced at mid- and high-latitudes where they exhibit the rotation rates representative of those latitudes. These are clearly large, long-lived, cellular features, with the dynamical characteristics expected from the effects of the Sun's rotation, but the shapes of the cells are not well represented in numerical models. While the Giant Cell flow velocities are small (<10 m/s), their long lifetimes should nonetheless substantially impact the transport of magnetic flux in the Sun's near surface layers.

Hathaway, David H.↗

An Electrochemical Hydrogen-Looping System for Low-Cost CO 2 Capture from Seawater

Carbon dioxide (CO 2 ) capture from seawater is a viable, long-term solution for addressing legacy carbon pollution on the planet. However, significant challenges to widespread applicability exist in terms of efficiency, cost, and scalability. In this work, we have developed an electrochemical hydrogen-looping (EHL) system that capitalizes on the generation of proton and OH – from seawater. A CO 2 capture efficiency as high as 91% is achieved for our EHL flow cell. We have demonstrated that the electrochemical hydrogen-looping flow cell can remove CO 2 from simulated seawater at a record low electric energy consumption of 660 kWh ton –1 CO 2 , which is a significant reduction of 56% compared with the currently used bipolar membrane electrodialysis technology. In conclusion, the electrochemical hydrogen-looping flow cell with its much lower energy consumption provides an economical approach for direct removal of CO 2 from seawater at practical scale.

Electrical energy↗

Impact of mineral precipitation on flow and mixing in porous media determined by microcomputed tomography and MRI

Here, precipitation reactions in porous media influence transport properties of the environment and can control advective and dispersive transport. In subsurface environments, mixing of saline groundwater or injected solutions for remediation with fresh groundwater can induce supersaturation of constituents and drive precipitation reactions. Magnetic resonance imaging (MRI) and micro-computed tomography (µ-CT) were employed as complimentary techniques to evaluate advection, dispersion and formation of precipitate in a 3D porous media flow cell. Two parallel fluids were flowed concentrically through the porous media under two flow rate conditions with Na 2 CO 3 and CaCl 2 in the inner and outer fluids, respectively. Upon mixing, calcium carbonate became supersaturated and formed a precipitate at the interface of the two fluids. Spatial maps of changing local velocity fields and dispersion in the flow cell were generated from MRI, while high resolution imaging of the precipitate formed in the porous media was achieved via µ-CT imaging. Formation of a precipitate layer minimized dispersive and advective transport between the two fluids and the shape of the precipitation was influenced by the flow rate condition.

54 ENVIRONMENTAL SCIENCES↗

Quantifying concentration distributions in redox flow batteries with neutron radiography

Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

Science & Technology - Other Topics↗

Interface Shape and Convection During Solidification and Melting of Succinonitrile

An experimental study was conducted of the crystal growth of succinonitrile during solidification, melting, and no-growth conditions using a horizontal Bridgman furnace and square glass ampoule. For use as input boundary conditions to numerical codes, thermal profiles on the outside of the ampoule at five locations around its periphery were measured along the ampoule's length. Temperatures inside the ampoule were also measured. The shapes of the s/l interface in various two dimensional planes were quantitatively determined. Though interfaces were nondendritic and noncellular, they were not flat, but were highly curved and symmetric in only one unique longitudinal y-z plane (at x=O). The shapes of the interface were dominated by the primary longitudinal flow cell characteristic of shallow cavity flow in horizontal Bridgman; this flow cell was driven by the imposed furnace temperature gradient and caused a 'radical' thermal gradient such that the upper half of the ampoule was hotter than the bottom half. We believe that due to the strong convection, the release of latent heat does not significantly influence the thermal conditions near the interface. We hope that the interface shape and thermal data presented in this paper can be used to optimize crystal growth processes and validate numerical models.

Degroh, Henry C., III↗

Flow cytometer acquisition and detection system

A flow cytometer has a flow cell through which a sample flows and at least one laser emitting an excitation beam for illuminating a corresponding interrogation region in the flow cell. Scattered and fluorescence light from each interrogation region is collected by one or more input fibers for that region, and the input fiber(s) are fed to a dispersion module for that interrogation region that disperses the incoming light into different spectral regions. The dispersed light is conveyed, such as by a plurality of output fibers, to one or more photosensitive detectors. Thus, time multiplexed light signals may be delivered to a detector whereby several unique light signals can be measured by a single detector.

47 OTHER INSTRUMENTATION↗

Generation of Stable, Low-Divergence Electron Beams by Laser-Wakefield Acceleration in a Steady-State-Flow Gas Cell

Laser-driven, quasimonoenergetic electron beams of up to {approx}200 MeV in energy have been observed from steady-state-flow gas cells. These beams emitted within a low-divergence cone of 2.1{+-}0.5 mrad FWHM display unprecedented shot-to-shot stability in energy (2.5% rms), pointing (1.4 mrad rms), and charge (16% rms) owing to a highly reproducible gas-density profile within the interaction volume. Laser-wakefield acceleration in gas cells of this type provides a simple and reliable source of relativistic electrons suitable for applications such as the production of extreme-ultraviolet undulator radiation.

43 PARTICLE ACCELERATORS↗