Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flux Wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Turbulent Parameters by airborne measurements over BNF in March 2025

The original data were collected during the AAF Engineering Flights (AEF2025) in the vicinity of the ARM Bankhead National Forest (BNF) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/bnf ) in northwestern Alabama in March 2025. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at the public-use airport of Posey Field, Alabama (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from March 10 through March 24, 2025. The ArcticShark UAS performed nine flights, including eight research flights over the AMF3 (BNF Main Site) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, and aerosol number concentration and size distribution. The current data set presents a collection of turbulent parameters in the atmospheric boundary layer or lower free troposphere based on airborne measurement throughout the field campaign. The primary instruments used to create the current data set were the Aircraft Integrated Meteorological Measurement System (AIMMS-30) and the fine-wire thermocouple probe.

Atmosphere↗

Breakdown Limit Studies in High-Rate Gaseous Detectors

We report results from a systematic study of breakdown limits for novel high-rate gaseous detectors: MICROMEGAS, CAT and GEM, together with more conventional devices such as thin-gap parallel-mesh chambers and high-rate wire chambers. It was found that for all these detectors, the maximum achievable pin, before breakdown appears, drops dramatically with incident flux, and is sometimes inversely proportional to it. Further, in the presence of alpha particles, typical of the breakgrounds in high-energy experiments, additional gain drops of 1-2 orders of magnitude were observed for many detectors. It was found that breakdowns at high rates occur through what we have termed an "accumulative" mechanism, which does not seem to have been previously reported in the literature. Results of these studies may help in choosing the optimum detector for given experimental conditions.

Ivaniouchenkov, Yu↗

Methodology of the Extraction of Multi-Differential Cross Sections of Charged-Current $\nu_\mu$-Argon Interactions in MicroBooNE Using Wire-Cell $\nu_\mu$CC Selection

Neutrino physics experiments rely on accurate nuclear-interaction models that are in part guided by experimental observations. Multi-differential cross section measurements are particularly valuable for exploring the underlying physics described in these models, making them a significant step forward in the field. This note presents methodology in preparation to unfold neutrino flux-averaged double and triple-differential cross sections of the inclusive muon neutrino charged-current interaction on Argon. This work builds upon the existing framework and methodology presented in recent energy dependent cross section measurements at MicroBooNE using the Wire-Cell tomographic event reconstruction. The signal definition, choice of binning, and handling of estimated detector uncertainties are discussed, and the MicroBooNE simulation model is validated over the multi-dimensional phase space of muon momentum, muon polar angle, and visible hadronic energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Design and Fabrication of Hydrated-Salt Pills

A high-performance design, and fabrication and growth processes to implement the design, have been devised for encapsulating a hydrated salt in a container that both protects the salt and provides thermal conductance between the salt and the environment surrounding the container. The unitary salt/container structure is known in the art as a salt pill. In the original application of the present design and processes, the salt is, more specifically, a hydrated paramagnetic salt, for use as a refrigerant in a very-low-temperature adiabatic demagnetization refrigerator (ADR). The design and process can also be applied, with modifications, to other hydrated salts. Hydrated paramagnetic salts have long been used in ADRs because they have the desired magnetic properties at low temperatures. They also have some properties, disadvantageous for ADRs, that dictate the kind of enclosures in which they must be housed: Being hydrated, they lose water if exposed to less than 100-percent relative humidity. Because any dehydration compromises their magnetic properties, salts used in ADRs must be sealed in hermetic containers. Because they have relatively poor thermal conductivities in the temperature range of interest (<0.1 K), integral thermal buses are needed as means of efficiently transferring heat to and from the salts during refrigeration cycles. A thermal bus is typically made from a high-thermal-conductivity met al (such as copper or gold), and the salt is configured to make intimate thermal contact with the metal. Commonly in current practice (and in the present design), the thermal bus includes a matrix of wires or rods, and the salt is grown onto this matrix. The density and spacing of the conductors depend on the heat fluxes that must be accommodated during operation.

Shirron, Peter J.↗

Thin Film Sensors for Minimally-Intrusive Measurements in Harsh High Temperature Environment

Advanced thin film sensors are being developed to provide accurate surface temperature, heat flux and strain measurements for components used in hostile propulsion environments. These sensors are sputter deposited and microfabricated directly onto the test articles with no additional bonding agent. The thickness of the sensors is only a few micrometers which creates minimal disturbance of the gas flow over the test surface. Thus thin film sensors have the advantage over conventional wire- based sensors by providing minimally intrusive measurement and having a faster response. These thin film sensors are being developed for characterization of advanced materials and structures in hostile, high-temperature environments, and for validation of design codes. This paper presents the advances of three high temperature thin film sensor technologies developed at NASA Lewis Research Center: thermocouples, heat-flux gages and strain gages. The fabrication techniques of these thin film sensors which include physical vapor deposition, photolithography patterning and lead Wire attachment are described. Sensors demonstrations on a variety of engine materials, including superalloys, ceramics and advanced ceramic matrix composites, in several hostile, high-temperature test environments are presented. The advantages and limitations of thin film sensor technology are also discussed.

Lei, Jih-Fen↗

Design, Construction, and Qualification of a Microscale Heater Array for Use in Boiling Heat Transfer

Boiling heat transfer is an efficient means of heat transfer because a large amount of heat can be removed from a surface using a relatively small temperature difference between the surface and the bulk liquid. However, the mechanisms that govern boiling heat transfer are not well understood. Measurements of wall temperature and heat flux near the wall would add to the database of knowledge which is necessary to understand the mechanisms of nucleate boiling. A heater array has been developed which contains 96 heater elements within a 2.5 mm square area. The temperature of each heater element is held constant by an electronic control system similar to a hot-wire anemometer. The voltage that is being applied to each heater element can be measured and digitized using a high-speed A/D converter, and this digital information can be compiled into a series of heat-flux maps. Information for up to 10,000 heat flux maps can be obtained each second. The heater control system, the A/D system and the heater array construction are described in detail. Results are presented which show that this is an effective method of measuring the local heat flux during nucleate and transition boiling. Heat flux maps are obtained for pool boiling in FC-72 on a horizontal surface. Local heat flux variations are shown to be three to six times larger than variations in the spatially averaged heat flux.

Rule, T. D.↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

The structure of 3-D collisional magnetized bow shocks in pulsed-power-driven plasma flows

Here we investigate three-dimensional (3-D) bow shocks in a highly collisional magnetized aluminium plasma, generated during the ablation phase of an exploding wire array on the MAGPIE facility (1.4 MA, 240 ns). Ablation of plasma from the wire array generates radially diverging, supersonic ($M_S$ $\sim 7$), super-Alfvénic ($M_A>1$) magnetized flows with frozen-in magnetic flux $(R_M\gg1)$. These flows collide with an inductive probe placed in the flow, which serves both as the obstacle that generates the magnetized bow shock, and as a diagnostic of the advected magnetic field. Laser interferometry along two orthogonal lines of sight is used to measure the line-integrated electron density. A detached bow shock forms ahead of the probe, with a larger opening angle in the plane parallel to the magnetic field than in the plane normal to it. Since the resistive diffusion length of the plasma is comparable to the probe size, the magnetic field decouples from the ion fluid at the shock front and generates a hydrodynamic shock, whose structure is determined by the sonic Mach number, rather than the magnetosonic Mach number of the flow. The 3-D simulations performed using the resistive magnetohydrodynamic (MHD) code Gorgon confirm this picture, but under-predict the anisotropy observed in the shape of the experimental bow shock, suggesting that non-MHD mechanisms may be important for modifying the shock structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Design of Micro Flux Monitors for Neutron Fluence Measurements

Measuring neutron flux is critical to understanding the characteristics of nuclear reactors and can provide information on the energy spectrum, total neutron fluence, and operational history of a facility. Such measurements are typically performed by irradiating high-purity materials in an operating reactor for a known length of time. By measuring and identifying activation products in the irradiated materials and referencing the energy-dependent cross section of each isotope, the neutron energy spectrum and total fluence can be determined. Historical techniques use a variety of small, individually pressed foils or wires for dosimeter devices, which can result in excessively high levels of radioactivity and complications in handling after irradiation. The present work describes a new neutron dosimetry concept, named the micro flux monitor, that uses semiconductor device fabrication processes to deposit thin films of flux monitoring materials in precise geometries onto a SiC wafer. This approach allows multiple dosimetry materials to be located on a single device, simplifying irradiation and subsequent analysis. The geometry, and therefore mass, of each material can be custom-tailored for a specific application—considering the expected neutron flux, duration of irradiation, and device retrieval time of a facility. Additionally, hundreds of identical dosimetry monitors can be produced simultaneously, reducing fabrication costs. Finally, the extremely thin metal dimensions of these devices could improve the fidelity of neutron fluence measurements by reducing neutron self-shielding and gamma self-attenuation effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Bismuth and Platinum Bi-Metallic Nanoparticles to Enhance Melt Wire Temperature Resolution

Advanced manufacturing (AM) based on direct-write (DW) technologies has emerged as the predominant enabler for the fabrication of active and passive sensors to be deployed in harsh operating environments seen in a nuclear reactor. Recently, Idaho National Laboratory and Boise State University have recently established capabilities to incorporate advanced manufacturing (AM) methods to accelerate, modernize and enhance functionality of nuclear sensors and instrumentation to achieve the goal of enhancing the safety and efficiency of nuclear reactors. A significant thrust of this work includes the development of nuclear relevant feedstock materials compatible with a variety of direct-write processes for the development, fabrication and testing of AM sensors for peak temperature detection and neutron flux monitoring. For this report, bismuth and bismuth/platinum (BiPt) bi-metallic nanoparticles were synthesized using wet chemical approaches to develop bi-metallic feedstock materials to enhance the sensitivity of melt wires for peak temperature detection. Nanoparticle characterization was performed with Transmission Electron Microscopy (TEM) for nanoparticle composition and size, Transmission X-Ray Diffraction Fluorescence (TXRF) for nanoparticle composition, and Differential Scanning Calorimetry to elucidate the melting point of BiPt bi-metallic nanoparticles. Preliminary results indicate bi-metallic BiPt nanoparticles as a viable pathway for fabricating high resolution AM melt wires.

36 MATERIALS SCIENCE↗

Tandem concentrator photovoltaic array applied to Space Station Freedom evolutionary power requirements

Additional power is required to support Space Station Freedom (SSF) evolution. Boeing Defense and Space Group, LeRC, and Entech Corporation have participated in the development of efficiency gallium arsenide and gallium antimonide solar cells make up the solar array tandem cell stacks. Entech's Mini-Dome Fresnel Lens Concentrators focus solar energy onto the active area of the solar cells at 50 times one solar energy flux. Development testing for a flight array, to be launched in Nov. 1992 is under way with support from LeRC. The tandem cells, interconnect wiring, concentrator lenses, and structure were integrated into arrays subjected to environmental testing. A tandem concentrator array can provide high mass and area specific power and can provide equal power with significantly less array area and weight than the baseline array design. Alternatively, for SSF growth, an array of twice the baseline power can be designed which still has a smaller drag area than the baseline.

Fisher, Edward M., Jr.↗

Analysis of WIRE-21 SPND and Optical Fiber Sensor Measurements

The Wireless Instrumented RB Experiment 2021 (WIRE-21) was a highly instrumented experiment designed to test prototype wireless temperature and pressure sensors developed by Westinghouse Electric Corporation (WEC) in the High Flux Isotope Reactor (HFIR). In addition to these sensors, a suite of other sensors was also integrated into the experiment capsule, including various types of distributed optical fiber sensors and self-powered neutron detectors (SPNDs). This report presents an analysis of the data generated by the SPNDs and optical fiber sensors that were tested under the highest reported neutron flux. The distributed optical fiber sensor results demonstrate that F-doped optical fibers, particularly those inscribed with fs fiber Bragg gratings (FBGs), are capable of surviving fast neutron fluences on the order of 1021 n fast /cm 2 at temperatures relevant to light-water reactors (between 200 and 400°C). However, a significant blue-shift in the optical spectra of these sensors was observed over the course of irradiation which cannot be explained based on the current understanding of radiation-induced compaction in fused silica glass. A mechanistic understanding of this drift has not yet been developed and is proposed as future scope under the Advanced Sensors and Instrumentation program. Of the four SPNDs, only one appeared to operate normally during three cycles of irradiation. A radiation transport model of the experiment in HFIR was used to determine time-dependent neutron flux in this SPND and to calculate the neutron sensitivity of the device. Results showed a cycle averaged sensitivity of 1.5 ×10 -22 and 1.4 ×10 -22 A/nν for the first and third cycles of irradiation, respectively. Additional details pertaining to the optical fibers and SPNDs are included herein.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combination probe for hi-frequency unsteady aerodynamic measurements

A combination probe for time-resolved measurements of unsteady compressible flows in transonic wind tunnels is described. The probe measures stagnation (total) temperature and pressure, static pressure, and flow angles in two planes. From these, the fluctuating mass flux, Mach number, and velocity as well as their components in three directions can be deduced. The combination probe consists of a dual hot-wire aspirating temperature and pressure probe mounted piggyback with a high-frequency angle probe. The angle probe has four surface-mounted silicon pressure sensors. A scheme is described for retrieving from the four pressure signals the stagnation and static pressures, Mach number, and flow angles in two planes. The calibrations forming the base for this procedure, obtained from steady-state tests, are given. Typical data obtained in the Karman vortex street shed from a cylinder and at the exit of a Mach 0.4 air jet are presented.

Ng, W. F.↗

A combination probe for high-frequency unsteady aerodynamic measurements in transonic wind tunnels

A combination probe for time-resolved measurements for unsteady compressible flows is described. The probe measures stagnation (total) temperature and pressure, static pressure, and flow angles in two planes. From these, the fluctuating mass flux, Mach number, and velocity as well as their components in three directions can be deduced. The combination probe consists of a dual hot-wire aspirating temperature and pressure probe mounted piggyback with a high-frequency angle probe. The angle probe has four surface-mounted silicon pressure sensors. A scheme is described for retrieving from the four pressure signals the stagnation and static pressures, Mach number, and flow angles in two planes. The calibrations forming the basis for this procedure, obtained from steady-state tests, are given. Typical data obtained in the Karman vortex street shed from a cylinder and at the exit of a Mach-0.4 air jet are presented.

Ng, Wing F.↗

Thermomechanical Reliability Aspects of Automotive Power Electronics: Current Status and Future Trends

Common failure locations (e.g., wire bonds, solder interface) and mechanisms within traditional automotive power electronics package designs and reliability concerns associated with packaging at higher temperatures and higher heat fluxes will be discussed. Examples of packaging solutions that increase mechanical reliability will be presented and state-of-health (SOH) estimation using offline and online (in situ) techniques will be described.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Solar radio spectrum extended to 10 km wavelength

Solar radio spectra for quiet times and radio bursts in the wavelength range from 1 mm to 10 km are presented. Solar nonthermal emission in the range of 100 m to 10 km was monitored by means of long wire antennas connected to multi-channel radiometers in the frequency range 25 kHz to 10 MHz on board the IMP-6 and RAE-1 satellites. Flux densities for very intense type III bursts with intensities ranging from 10 to the -18th to 10 to the -14th W/sq m per Hz with maxima at 330 to 1500 m are shown, and a power-law wavelength distribution function of maximum burst intensities is derived. Intensities of a large type III noise storm are shown to increase with increasing wavelength to a peak near 500 m. The flux densities of both types of burst emission are observed to greatly exceed quiet sun intensities at long wavelengths.

Weber, R. R.↗

Improved Sensing Coils for SQUIDs

An improvement in the design and fabrication of sensing coils of superconducting quantum interference device (SQUID) magnetometers has been proposed to increase sensitivity. It has been estimated that, in some cases, it would be possible to increase sensitivity by about half or to reduce measurement time correspondingly. The pertinent aspects of the problems of design and fabrication can be summarized as follows: In general, to increase the sensitivity of a SQUID magnetometer, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. It is often beneficial to fabricate the coil from a thicker wire to reduce its self-inductance. Moreover, to optimize the design of the coil with respect to sensitivity, it may be necessary to shape the wire to other than a commonly available circular or square cross-section. On the other hand, it is not practical to use thicker superconducting wire for the entire superconducting circuit, especially if the design of a specific device requires a persistent-current loop enclosing a remotely placed SQUID sensor. It may be possible to bond a thicker sensing-coil wire to thinner superconducting wires leading to a SQUID sensor, but it could be difficult to ensure reliable superconducting connections, especially if the bonded wires are made of different materials. The main idea is to mold the sensing coil in place, to more nearly optimum cross sectional shape, instead of making the coil by winding standard pre-fabricated wire. For this purpose, a thin superconducting wire loop that is an essential part of the SQUID magnetometer would be encapsulated in a form that would serve as a mold. A low-melting-temperature superconducting metal (e.g., indium, tin, or a lead/tin alloy) would be melted into the form, which would be sized and shaped to impart the required cross section to the coil thus formed.

Penanen, Konstantin↗

Understanding Materials Characteristics of Palladium Lanthanide Cermet Wires as a Mimic of Californium Wire Production

Californium-252 (Cf-252) has been synthesized on a large scale (mg) since the 1970s for use as a portable neutron source. With a half-life of 2.645 years and a spontaneous fission fraction of 3.09%, Cf-252 emits 2.31 × 10 12 neutrons/gram second. Today most of the Cf-252 produced in the world is made at Oak Ridge National Laboratory (ORNL) using the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC). Because of its highly radioactive nature, all manipulations of Cf-252 need to be performed in hot cell facilities by highly trained personnel. The Cf-252 produced at ORNL is done at the REDC, which is conveniently located next to the HFIR. Cf-252 is sold as bulk wire, which has been described as palladium (Pd) metal incasing californium oxide (Cf 2 O 3 ). The process was developed by Mosley et al. at Savannah River Laboratory (SRL) where it was modeled after the thorium work done by Fuschillo et al. This process has been used since the 1970s to synthesize this unique wire, but its fundamental chemistry and materials characteristics were never openly reported. Here we aim to better understand the chemistry and the materials characteristics of Cf-252 wire production for process improvements and to better our fundamental understanding of the mid-late actinides. Though there are many challenges in working with radioactive elements such as Cf, the isotope Cf-252 is even more complicated due to its neutron emission. One challenge with neutron emission is the ability of neutrons to penetrate much deeper through materials, causing radiation damage. This makes using instrumentation to characterize the chemistry and materials properties of this process difficult. For this reason, this study will first focus on terbium (Tb) as a surrogate for Cf. Currently Tb is used as a carrier or filler in Cf production when small amounts of Cf are being processed. This, along with their similar size and charge, makes Tb a reasonable surrogate for this study.

36 MATERIALS SCIENCE↗