Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fringe fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

On the length of the drift region in the Ramsey cavity

The interaction of atoms in a beam with the microwave field in a separated field geometry such as a Ramsey cavity is generally described in terms of the three regions traversed successively by the atoms, namely two interaction regions of length (l) separated by a drift, or free precession, region of length L. For a monokinetic beam of velocity v, the linewidth of the central fringe in the Ramsey resonance pattern is usually expressed as delta omega equals pi v/L. A more detailed calculation shows, however, that the linewidth is equal to pi v/L asterisk, where the equivalent drift L asterisk is larger than L by an amount of the order of l/L. The correction depends on the field distribution in the interaction regions. Its origin lies in the fact that atomic precession is not limited to the field-free regions but also occurs in the interaction regions, where atomic coherence builds up or decreases continuously. Although the correction to the equivalent length of the drift region is small, it may be relevant to the evaluation of the second-order Doppler effect bias in primary cesium-beam standards to the extent that the atomic velocity is deduced from the lineshape and from the geometrical parameters of the cavity. It is shown that in current and projected standards with atoms of average thermal velocity, use of corrected dimensions may lead to a change of the calculated bias of the order of 10(exp -14), which is significant at the levels of accuracy considered nowadays.

Thomann, Pierre↗

Doppler Global Velocimetry Measurements for Supersonic Flow Fields

The application of Doppler Global Velocimetry (DGV) to high-speed flows has its origins in the original development of the technology by Komine et al (1991). Komine used a small shop-air driven nozzle to generate a 200 m/s flow. This flow velocity was chosen since it produced a fairly large Doppler shift in the scattered light, resulting in a significant transmission loss as the light passed through the Iodine vapor. This proof-of-concept investigation showed that the technology was capable of measuring flow velocity within a measurement plane defined by a single-frequency laser light sheet. The effort also proved that velocity measurements could be made without resolving individual seed particles as required by other techniques such as Fringe- Type Laser Velocimetry and Particle Image Velocimetry. The promise of making planar velocity measurements with the possibility of using 0.1-micron condensation particles for seeding, Dibble et al (1989), resulted in the investigation of supersonic jet flow fields, Elliott et al (1993) and Smith and Northam (1995) - Mach 2.0 and 1.9 respectively. Meyers (1993) conducted a wind tunnel investigation above an inclined flat plate at Mach 2.5 and above a delta wing at Mach 2.8 and 4.6. Although these measurements were crude from an accuracy viewpoint, they did prove that the technology could be used to study supersonic flows using condensation as the scattering medium. Since then several research groups have studied the technology and developed solutions and methodologies to overcome most of the measurement accuracy limitations:

Meyers, James F.↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Caustics and Caustic-Diffraction in Laser Shadowgraphy of a Sessile Drop and Identification of Profile Near Contact Line

This paper presents an optical method based on the caustics and caustic-difraction in laser shadowgaphy of a sessile drop to identify and estimate the drop profile near the contact line. A parallel laser beam passes through a liquid sessile drop placed on a transparent substrate to produce a shadowgraphic image of the drop on the screen far from the substrate. Along the inflection line of the drop the Gaussian curvature of the wavefront deformed by the drop vanishes, and therefore the inflection line gives caustics in the far field of the wave, which can be seen on the screen. The neighboring light rays at both sides of the inflection line interfere with each other to form interference fringes at the inner side of the caustics. According to the pattern of the caustics, the drop-profile shape can be identified and estimated.

Zhang, Neng-Li↗

Non-Isothermal Experimental Study of the Constrained Vapor Bubble Thermosyphon

Experimental and theoretical techniques to study non-isothermal transport processes in the constrained vapor bubble thermosyphon (CVBT) were developed using a pentane/quartz system. The transport processes can be evaluated by measuring the liquid film profile, which gives the pressure field, and the temperature field. The axial variation in the capillary pressure was measured using an image-analyzing interferometer that is based on computer-enhanced video microscopy of the naturally occurring interference fringes. Thermoelectric coolers were used to control the temperature level in the condensation region and, therefore, the length of the approximately 'adiabatic' surface region which is a function of the temperature difference between the CVBT surface and the surroundings. High values for the axial thermal conductance in the 'adiabatic' surface region were demonstrated under certain conditions.

Karthikeyan, Muthu↗

Laser Light Scattering by Shock Waves

Scattering of coherent light as it propagates parallel to a shock wave, formed in front of a bluff cylindrical body placed in a supersonic stream, is studied experimentally and numerically. Two incident optical fields are considered. First, a large diameter collimated beam is allowed to pass through the shock containing flow. The light intensity distribution in the resultant shadowgraph image, measured by a low light CCD camera, shows well-defined fringes upstream and downstream of the shadow cast by the shock. In the second situation, a narrow laser beam is brought to a grazing incidence on the shock and the scattered light, which appears as a diverging sheet from the point of interaction, is visualized and measured on a screen placed normal to the laser path. Experiments are conducted on shocks formed at various free-stream Mach numbers, M, and total pressures, P(sub 0). It is found that the widths of the shock shadows in a shadowgraph image become independent of M and P(sub 0) when plotted against the jump in the refractive index, (Delta)n, created across the shock. The total scattered light measured from the narrow laser beam and shock interaction also follows the same trend. In the numerical part of the study, the shock is assumed to be a 'phase object', which introduces phase difference between the upstream and downstream propagating parts of the light disturbances. For a given shape and (Delta)n of the bow shock the phase and amplitude modulations are first calculated by ray tracing. The wave front is then propagated to the screen using the Fresnet diffraction equation. The calculated intensity distribution, for both of the incident optical fields, shows good agreement with the experimental data.

Panda, J.↗

Advanced Modeling of Micromirror Devices

The flexure-beam micromirror device (FBMD) is a phase only piston style spatial light modulator demonstrating properties which can be used for phase adaptive corrective optics. This paper presents a complete study of a square FBMD, from advanced model development through final device testing and model verification. The model relates the electrical and mechanical properties of the device by equating the electrostatic force of a parallel-plate capacitor with the counter-acting spring force of the device's support flexures. The capacitor solution is derived via the Schwartz-Christoffel transformation such that the final solution accounts for non-ideal electric fields. The complete model describes the behavior of any piston-style device, given its design geometry and material properties. It includes operational parameters such as drive frequency and temperature, as well as fringing effects, mirror surface deformations, and cross-talk from neighboring devices. The steps taken to develop this model can be applied to other micromirrors, such as the cantilever and torsion-beam designs, to produce an advanced model for any given device. The micromirror devices studied in this paper were commercially fabricated in a surface micromachining process. A microscope-based laser interferometer is used to test the device in which a beam reflected from the device modulates a fixed reference beam. The mirror displacement is determined from the relative phase which generates a continuous set of data for each selected position on the mirror surface. Plots of this data describe the localized deflection as a function of drive voltage.

Michalicek, M. Adrian↗

Holographic flow visualization at the Langley CF4 tunnel

A holographic flow visualization system was used to obtain shadowgraph, schlieren, and interferograms of the flow field at Langley's hypersonic (Mach 6) CF4 tunnel. The dual hologram technique which was used makes it possible to vary focusing, knife-edge position, and the orientation and spacing of the interference fringes after a tunnel run. The experimental arrangement necessary to produce high quality interferograms is discussed. Typical shadowgraphs, schlieren pictures, and interferograms are presented.

Burner, A. W.↗

Stabilization of interferometer fringe patterns

Fringe pattern motion is compensated by closed-loop servo system that adjusts a mirror mounted on piezoelectric crystal, so that path difference in interferometer is maintained at constant values at one point in the field. System is applicable to holography with continuous wave laser sources.

Brown, R. M.↗

Measurement of flow fields in a large transonic wind tunnel using a laser velocimeter

An investigation to determine the feasibility of using a laser velocimeter for measuring the mean flow velocities about airplane models in the Langley 16-foot transonic tunnel has recently been completed. The laser velocimeter was a two-component fringe-type used in the back scatter mode. The tunnel airflow was seeded with oil droplets to provide scattering sources for the laser velocimeter. Measurements of the tunnel free-stream velocity were in good agreement with the tunnel calibration, and measurements of the velocity along the stagnating streamline of a hemisphere model, when adjusted for particle lag, were in good agreement with theoretical predictions. The study showed that the laser, optics, and electronics system operated satisfactorily, but that further development is required to reduce scattering particle size and substance accumulation in the tunnel.

Putnam, L. E.↗

Fourier-Transform Infrared Spectrometer

Fourier-transform spectrometer provides approximately hundredfold increase in luminosity at detector plane over that achievable with older instruments of this type. Used to analyze such weak sources as pollutants and other low-concentration substances in atmosphere. Interferometer creates fringe patterns on two distinct arrays of light detectors, which observe different wavelength bands. Objective lens focuses scene on image plane, which contains optical chopper. To make instrument less susceptible to variations in scene under observation, field and detector lenses focus entrance aperture, rather that image, onto detector array.

Schindler, R. A.↗

Laser velocimeter systems analysis applied to a flow survey above a stalled wing

A laser velocimeter operating in the backscatter mode was used to survey the flow above a stalled wing. Polarization was used to separate the two orthogonal velocity components of the fringe-type laser velocimeter, and digital counters were used for data processing. The velocities of the kerosene seed particles were measured with less than 2 percent uncertainty. The particle velocity measurements were collected into histograms. The flow field survey was carried out above an aspect-ratio-8 stalled wing with an NACA 0012 section. The angle of attack was 19.5 deg, the Mach number was 0.49, and the Reynolds number was 1,400,000. The flow field was characterized by the periodic shedding of discrete vortices from near the crest of the airfoil.

Young, W. H., Jr.↗

Six Years of Parallel Computing at NAS (1987 - 1993): What Have we Learned?

In the fall of 1987 the age of parallelism at NAS began with the installation of a 32K processor CM-2 from Thinking Machines. In 1987 this was described as an "experiment" in parallel processing. In the six years since, NAS acquired a series of parallel machines, and conducted an active research and development effort focused on the use of highly parallel machines for applications in the computational aerosciences. In this time period parallel processing for scientific applications evolved from a fringe research topic into the one of main activities at NAS. In this presentation I will review the history of parallel computing at NAS in the context of the major progress, which has been made in the field in general. I will attempt to summarize the lessons we have learned so far, and the contributions NAS has made to the state of the art. Based on these insights I will comment on the current state of parallel computing (including the HPCC effort) and try to predict some trends for the next six years.

Simon, Horst D.↗

Advanced ballistic range technology

Experimental interferograms, schlieren, and shadowgraphs are used for quantitative and qualitative flow-field studies. These images are created by passing light through a flow field, and the recorded intensity patterns are functions of the phase shift and angular deflection of the light. As part of the grant NCC2-583, techniques and software have been developed for obtaining phase shifts from finite-fringe interferograms and for constructing optical images from Computational Fluid Dynamics (CFD) solutions. During the period from 1 Nov. 1992 - 30 Jun. 1993, research efforts have been concentrated in improving these techniques.

Yates, Leslie A.↗

The excitation of plasma waves by a current source moving in a magnetized plasma - The MHD approximation

Alfven waves are important in natural-space phenomena, and studies of these waves have been conducted by performing active experiments in space plasma. One method to study these waves involves the use of an electrodynamic tether. The electrodynamic tether consists of a subsatellite with a conducting outer surface connected to the Space Shuttle by an insulator-clad, conducting wire about 20 kilometers in length. The emf generated by the motion of the tether across the geomagnetic field will act to drive a current through the tethered system. It is pointed out that this current in the tether acts as a source for exciting the shear-Alfven wave. In the present investigation it is shown that fringing effects play a dominant role in determining the radiation pattern for currently envisioned deployments of the tether. The current paper is the first of three papers concerned with the excitation of low-frequency waves arising from a current source moving through a cold, magnetized plasma.

Rasmussen, C. E.↗

Flow visualization in a cryogenic wind tunnel using holography

Results of holographic flow visualization from tests made in the Langley 0.3 meter transonic cryogenic tunnel are presented. The tunnel was operated over a temperature range from 100 to 300 K and a pressure range from 1.1 to 4 atm. Interferometry at the facility may be of limited use at the low temperature high pressure conditions because of the jumbled nature of the reference fringes. The shadowgraph technique appears to be the best means of visualizing shocks at these high density conditions. The spot size at the focus of the reconstructed beams was measured and used as an indicator of density fluctuations in the flow field. These density fluctuations appear to be caused by temperature fluctuations of the test gas which are relatively independent of tunnel conditions.

Burner, A. W.↗

Flow visualization in a cryogenic wind tunnel using holography

Results of holographic flow visualization from tests made in the Langley 0.3 meter transonic cryogenic tunnel are presented. The tunnel was operated over a temperature range from 100 to 300 K and a pressure range from 1.1 to 4 atm. Interferometry at the facility may be of limited use at the low temperature high pressure conditions because of the jumbled nature of the reference fringes. The shadowgraph technique appears to be the best means of visualizing shocks at these high density conditions. The spot size at the focus of the reconstructed beams was measured and used as an indicator of density fluctuations in the flow field. These density fluctuations appear to be caused by temperature fluctuations of the test gas which are relatively independent of tunnel conditions.

Burner, A. W.↗

The megaparsec radio relic in supercluster, Rood No. 27

Observations of extended source of low surface brightness appear as a 'relic' of a currently inactive radio galaxy. The largest dimension is approximately 1.6 Mpc, the fractional polarization is high, and the magnetic field direction appears to be coherent over scales of at least several hundred kpc. Polarization and morphologies of relics are distinct from those of cluster halos, due to the different environment provided by cluster cores compared to that encountered in the outer fringes of the hot gas distribution which produces X-ray emission.

Harris, D. E.↗