Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Experimental demonstration of high-temperature (>1000 °C) heat extraction from a moving-bed oxidation reactor for thermochemical energy storage

Previously developed reduction-oxidation (redox) thermochemical energy storage technologies must store their products at high temperatures, complicating handling and transportation. This work describes a countercurrent, tubular, moving bed oxidation reactor at laboratory scale that produces high grade heat and allows solids to enter and exit the system at ambient temperatures. The particles implemented in the system consist of a novel magnesium manganese-oxide material well-suited for thermochemical energy storage. Output heat is obtained via a separate extraction gas flow, which exits from the middle portion of the main reactor tube. With this design, reactor temperatures in excess of 1000°C and extraction temperatures above 950°C were achieved. Deviation between the two measurements is a result of extraction thermocouple placement and losses in the reactor extraction arm; improvements to these parameters would bring the extraction temperature closer to the bed temperature. The reactor produces enough energy via oxidation to sustain both heat extraction and continued chemical reaction. During one representative steady state experiment at a particle flow rate of 1.5 g/s, an average of 447 W was extracted from the reactor out of an estimated 1083 W of released chemical energy for a duration of 70 minutes. Among the four experiments, the maximum bench-scale oxidation reactor energy efficiency of 36.2% and corresponding round-trip efficiency of 13.7% considering both redox reactors were demonstrated. Characteristics of an ideal system are considered and future improvements are proposed.

25 ENERGY STORAGE↗

Challenges in Kinetic modeling of ammonia pyrolysis

Ammonia pyrolysis reactions have implications for its ignition and oxidation in engines and gas turbines. In the present work, the chemistry of ammonia pyrolysis is investigated by kinetic modeling and theory. Rate constants for key reactions are carefully evaluated based on available experimental and theoretical results. The high pressure limit k1,∞ for NH 2 + H (+M) ⇄ NH 3 (+M) (R1) is calculated to be essentially the collision frequency, indicating that dissociation of ammonia in combustion processes will be at or close to the low pressure limit even at engine and gas turbine conditions. The chemical kinetic model is validated against reported shock tube measurements of NH 3 , NH 2 , and NH in ammonia pyrolysis. Predictions are in good agreement with observations for dilute conditions (≤ 0.5% NH 3 ), but the model appears to underpredict the NH 3 consumption rate at longer times in less dilute mixtures. At short reaction times, thermal dissociation of NH3, together with the NH 3 + H reaction, controls conversion. At longer times, secondary reactions involving NH 2 and NH become important due to their impact on the radical pool. Predictions become sensitive to formation and consumption of diazene (tHNNH and cHNNH). Several of the key steps in the ammonia pyrolysis mechanism are radical-radical reactions that are difficult to measure accurately and challenging to calculate theoretically, and a more comprehensive experimental characterization is desirable to support further model development.

10 SYNTHETIC FUELS↗

Design, Flow Field, and Heat Transfer Characterization of the Conjugate Aero-Thermal Test Facility at NETL

A new aerothermal test facility was constructed for the purpose of studying film cooling performance in an environment that accurately simulates conjugate heat transfer characteristics that exist in engine operation. Here, this paper details the design of the facility and the plan for conducting steady state film cooling experiments to improve the understanding of conjugate heat transfer scaling from laboratory to engine conditions. The test facility consists of two separate low channels (hot gas/coolant) and each gas path has a flow conditioning section, a convergent nozzle and a test section/channel with viewports. Numerical simulations were conducted to predict flow field characteristics supporting the design of the flow loop facility. Preliminary experiments were conducted to characterize the flow field using velocity and temperature profile measurements. In addition, infrared (IR) thermography methods were developed to measure surface temperatures on the hot side of the test plate. The IR measurement methods including calibration of the IR camera is explained in detail. It was concluded that appropriate hot gas path flow conditioning could be achieved using a strainer-like tube, a perforated plate, and a honeycomb-mesh screen system upstream of the test section. Flow field measurements from preliminary experiments showed that the boundary layer profile follows the law of the wall.

47 OTHER INSTRUMENTATION↗

Environmental Validation of Materials and Design Concepts to Enable Operational Flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility will need to be evaluated for resilience to frequent start-ups, meeting major and rapid load changes, and providing frequency control duties. Our research objective was to evaluate and improve flexibility of existing power plants by improving and redesigning components and defining new operational strategies, with acceptable impacts on component life, efficiency and emissions.

20 FOSSIL-FUELED POWER PLANTS↗

Tritium Transport Phenomena in Molten-Salt Reactors

In this work, we review phenomena relevant to tritium transport in molten-salt reactors, which produce tritium from lithium and beryllium salts at significantly higher levels than other reactor types. Modeling of such phenomena began following MSRE operations, and these early models attempted to predict measured tritium distributions in the MSRE, accounting for turbulent mass-transport processes (using established heat transfer correlations), permeation through a variety of metal structures such as heat exchanger tubes, and transport to and from bubbles introduced into the salt by gas sparging. The models reasonably reproduced the MSRE data, but did so best when the permeability of structures was reduced by about a factor of 1,000. This issue does not appear to have been conclusively resolved, and all of the more recent attempts to model tritium transport in molten salts appear to make use of the same methodology. MSRE remains, however, essentially our only source of integral tritium transport data relevant to MSRs. Here, we generalize the MSRE approach to permeation in order to include potential rate-limiting effects at interfaces, as well the effects of added hydrogen. Appropriately non-dimensionalized, this system of equations identifies two dimensionless numbers whose relative values clearly delineate the conditions under which mass transport, surface effects, permeation, and hydrogen swamping are expected to become rate-limiting. We also describe the preliminary conceptual design of a forced convection FLiBe loop, into which tritium would be introduced for the purpose of providing validation data for such a model. The primary purpose of this is to investigate the coupled transport phenomena described above and identify those that are rate-limiting in MSRs. Additional test section configurations are described that would address other transport phenomena relevant to MSRs, including bubbly flows and graphite interactions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Formation of Composite SiC/SiC Joints by Embedded Wire Chemical Vapor Deposition

The joining of ceramic monoliths or composites to date has primarily been limited to the formation of brittle monolithic joints using heterogeneous (dissimilar) materials, similar to brazing in metals. The development of a damage-tolerant joint layer by SiC fiber reinforcements is demonstrated here. Tube workpieces made of SiC fiber-SiC matrix composite are joined using a nonwoven SiC fiber mat densified by embedded wire chemical vapor deposition (EWCVD), creating a fiber-reinforced weld-like joint by homogeneous joining. EWCVD uses a localized heating method to target deposition and growth to the joint region specifically, while minimizing thermal damage to the surrounding composite tube material. X-ray computed tomography (XCT) is used to nondestructively characterize as-made joints for relative density, adhesion, and composition. In situ XCT analysis during mechanical testing revealed crack deflections in the bonding layer, which indicates a toughening mechanism typical of ceramic matrix composite phase. Gas permeation testing of these proof-of-concept composite joints identified relatively high leak rates in comparison to fully coated SiC/SiC composite tube workpieces. In conclusion, the novelty of the composite joining method and current technology challenges, including gas permeability, are discussed in comparison with traditional ceramic joints and materials.

SiC↗

Cylinder Test

In 1941 G.I. Taylor proposed the cylinder test as an experiment to determine the properties of explosive products. The test consists of a hollow metal cylinder containing an unreacted cylindrical charge of explosives. The charge is detonated at one end of the cylinder and, as the detonation wave propagates, the product gas expands behind it. As the product gas is produced, the pressure acting on the metal increases and begins to push the walls outward. Consider the time at which the detonation wave has reached the halfway point between the two ends of the cylinder. In front of the wave nothing has changed and the metal tube has the same initial radius. Behind the wave, the radius of the tube has expanded. The farther behind the wave a section of tube is, the larger its radius has become. The longer the wall is exposed to the pressurized gas, the more it expands, so that the radius is largest where the detonation was initiated. The metal most commonly used for this experiment is soft copper. Its material properties are well known and soft copper is also easy to shape with precision machining. During the cylinder test the radial expansion of the cylinder is measured over time and this data is used to determine the amount of work applied to the cylinder wall by the product gas as a function of time. Since volume increases in this problem, the time dependence can be seen as a volume dependence. The volume dependent work yields a path in thermodynamic space. The cylinder test experiment can be modeled using simulation. The simulation gives you the answer, but it cannot tell you why. The goal of the proposed work is to use analytic analysis methods to give insight into the simulation solution.

36 MATERIALS SCIENCE↗

TRACER-Tethersonde VOC data

One objective of TRACER-Tethersonde campaign was to deploy a volatile organic compound (VOC) sampler on the Tethered Balloon System (TBS) to create vertical profiles and characterize VOC composition. Volatile organic compounds (VOCs) are highly reactive precursor species that undergo atmospheric processing to form secondary products, including aerosol. VOC emissions are influenced by many factors that include but are not limited to temperature, time of day, local anthropogenic activities, and local vegetation, which result in large spatiotemporal variability. The vertical distribution of volatile species is crucial for understanding gas-phase processing for particle production but challenging to accomplish using currently available sampling devices. The standalone sampler built during the campaign enabled the execution of robust experimental designs, including sample collection using resin tubes at multiple altitudes on subsequent flights. Following field sampling, resin tubes were transported back to Baylor University for chemical analysis using a Markes International thermal desorption unit coupled with a gas chromatograph-tandem mass spectrometer (Thermo Scientific). The target analyte list includes biogenic and anthropogenic VOCs.

54 ENVIRONMENTAL SCIENCES↗

Formation and characterization of hydride rim structures in Zircaloy-4 nuclear fuel cladding tubes

Zirconium alloy tubes used as nuclear fuel cladding are subject to oxidation and subsequent hydrogen pickup during their long service in commercial light water reactors. The hydrogen picked up in the cladding can precipitate as a brittle hydride rim feature on the cladding outer surface. Here, to better understand the effect of hydride rims on the fracture behavior of stress-relieved zirconium alloy cladding tubes, a procedure to produce these rim-like structures has been developed and is described herein. Extensive characterization of the ‘as hydrided’ tubes is performed. The hydrogen charging apparatus consists of a tube furnace with a quartz chamber that is connected to a vacuum pump as well as a bottle of pure hydrogen gas. The charging station uses a static charge of hydrogen as opposed to a flowing gas. The chief advantage of this approach is the ability to monitor the pressure drop in the hydriding chamber and correlate this pressure drop to a known rate of hydrogen pickup in the cladding tube. It was found that the hydrogen partial pressure, metal temperature, and surface treatment all clearly played a role in whether a hydride rim was formed. Extensive characterization of the hydride rims shows they consist of needle like platelets of δ phase hydrides (ZrH1.66) oriented in the circumferential direction with a radial spacing of several microns in a sandwich-like structure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hypersonic Wake Velocity Measurements Using Acetone Molecular Tagging Velocimetry

A non-intrusive laser diagnostic known as molecular tagging velocimetry was used to find quantitative off-body velocity measurements in the wake of a sphere in the Mach 7 Ludwieg Tube Wind Tunnel located at The University of Texas at San Antonio. Acetone gas seeded in the flow was excited using the 4th harmonic of a pulse-burst Nd:YAG laser. The experimental results were used to validate and compare to simulations using a continuous Galerkin flow solver. Both the experimental and simulated results agreed on negative velocities in the viscous shear layer. Near the centerline of the sphere, average velocities of -200 m/s were observed due to reverse flow in the recirculation region. Outside of the shear layer, velocities of 800 m/s were observed in both the experimental and simulated results. The overall average uncertainty for the strut-mounted and free-flight case was estimated to be ±27 m/s. The flow features of the wake were visualized using schlieren imaging, and the experimental results agreed well with the simulated results.

Shoemake, Lawton↗

An Assessment of the Conversion of Biomass and Industrial Waste Products to Activated Carbon

The production of biochar from biomass and industrial wastes provides both environmental and economic sustainability. An effective way to ensure the sustainability of biochar is to produce high value-added activated carbon. The desirable characteristic of activated carbon is its high surface area for efficient adsorption of contaminants. Feedstocks can include a number of locally available materials with little or negative value, such as orchard slash and crop residue. In this context, it is necessary to determine and know the conversion effects of the feedstocks to be used in the production of activated carbon. In the study conducted for this purpose; several samples (piñon wood, pecan wood, hardwood, dried grass, Wyoming coal dust, Illinois coal dust, Missouri coal dust, and tire residue) of biomass and industrial waste products were investigated for their conversion into activated carbon. Small samples (approximately 0.02 g) of the feedstocks were pyrolyzed under inert or mildly oxidizing conditions in a thermal analyzer to determine their mass loss as a function of temperature and atmosphere. Once suitable conditions were established, larger quantities (up to 0.6 g) were pyrolyzed in a tube furnace and harvested for characterization of their surface area and porosity via gas sorption analysis. Among the samples used, piñon wood gave the best results, and pyrolysis temperatures between 600 and 650 °C gave the highest yield. Slow pyrolysis or hydrothermal carbonization have come to the fore as recommended production methods for the conversion of biochar, which can be produced from biomass and industrial wastes, into activated carbon.

09 BIOMASS FUELS↗

Design of a Combined Proportional Integral Derivative Controller to Regulate the Temperature Inside a High-Temperature Tubular Solar Reactor

Solar fuels are proven to be promising candidates for thermochemical energy storage. However, the transient nature of solar radiation is an obstacle to maintaining a stable operational temperature inside a solar reactor. To overcome this challenge, the temperature of a solar reactor can be regulated by controlling the incoming solar radiation or the feedstock flowrate inside the reactor. In this work, a combined proportional integral derivative (PID) controller is implemented to regulate the temperature inside a high-temperature tubular solar reactor with counter-current flowing gas/particles. The control model incorporates two control systems to regulate incoming solar radiation and gas flow simultaneously. The design of the controller is based on a reduced-order numerical model of a high-temperature tubular solar reactor that is vertically oriented with an upward gas flow and downward particle flow. The reactor receives heat circumferentially through its wall over a finite segment of its length. Formulation of the heat transfer model is presented by applying the energy balance for the reactor tube and considering heat and mass transfer inside. A set of governing differential equations are solved numerically by using the finite volume method to obtain reactor wall, particles, and gas temperatures along the reactor length with various boundary conditions. Simulation results are used to tune the PID controller parameters by utilizing the Ziegler–Nichols tuning method. Both the simulation results and the controller performance are visualized on the LABVIEW platform. The controller is challenged to track different temperature setpoints with different scenarios of transient solar radiation. Here, the performance of the PID controller was compared to experimental results obtained from an industrial PID controller embedded in a 7 kW electric furnace. Results show that the combined PID controller is successful in maintaining a stable temperature inside the reactor by regulating the incoming solar radiation and the flowrate via small steady-state error and reasonable settling time and overshoot.

14 SOLAR ENERGY↗

SimELIT: A Novel GUI-Based Comprehensive Ion Trajectory Simulation Software for Mass Spectrometry

Ion trajectory simulation in mass spectrometry systems from injection to detection is technically challenging but very important for better understanding the ion dynamics in instrument development. Here, in this work, we present SimELIT (Simulator of Eulerian and Lagrangian Ion Trajectories), a novel ion trajectory simulation platform. SimELIT is built upon a suite of multiphysics solvers compiled into OpenFOAM (an open-source numerical solver library particularly used for computational mechanics), with a simple web-based graphical user interface (GUI) allowing users to define the details of OpenFOAM cases and run simulations. SimELIT is a modular program and can provide extensions of physics (e.g., gas flows, electrodynamic fields) and thus enable ion trajectory simulations from the ion source to detector. The current version (SimELIT) provides two numerical solvers for ion trajectory simulations–(1) a Lagrangian particle tracker in vacuum and (2) a Eulerian ion density solver in background gas in the presence of electric fields. Here, we describe the architecture of SimELIT, including its use of Docker and the React Framework, and demonstrate the computation of ion trajectories of multiple m/z values in a static/linear voltage drop in vacuum (across a 1 m long flight tube). Further, the drift motion of ions under 1 Torr pressure conditions in a static background (N 2 ) gas through a 20 V/cm static electric field is shown. The results produced from SimELIT were compared with SIMION and theoretical estimates. In addition, we report the computation of ion trajectories in electrodynamic fields within a planar FAIMS device operating at atmospheric pressure.

97 MATHEMATICS AND COMPUTING↗

Computational Fluid Dynamics Simulations to Predict Oxidation in Heat Recovery Steam Generator Tubes

Heat Recovery Steam Generators (HRSGs) are widely used across United States in combined cycle power plants to recover waste heat from the gas turbine (GT). HRSGs are used either to generate electricity or to produce process steam for industrial applications. The primary components of HRSG consists of a duct and a heat exchanger (HX). It is known across the power industry that the high temperature oxidation and ensuing exfoliation problem is a major cause for the damage of HX materials of HRSG. Alloys and/or coatings that can prevent or mitigate oxidation are very expensive, therefore they must be used or applied on the select regions of the HX tubes where the tendency of oxide formation is the highest. The main goal of this project is to identify such regions through Computational Fluid Dynamics (CFD) simulations. Therefore, in this work, we developed a CFD framework using commercial code StarCCM+ for the prediction of the fluid flow and heat transfer in a HRSG and associated oxidation inside the tubes of the HX. The developed CFD framework was verified and validated with experimental data before deployment. We also developed an innovative method to model the effect of the fins on the heat transfer and the pressure drop using a porous media model (PMM) approach to keep the mesh size within reasonable limits. After validation, we performed high-fidelity CFD simulations of a real-scale HRSG using the PMM, with High Performance Computing (HPC) resources of ORNL. From the simulation results, we acquired oxide thickness maps for all the tubes of the select HX sections of HRSG prone to oxidation. These oxide maps can inform regions of the HX tubes that requires oxide-resistant coatings, thereby guiding engineers for cost-efficient manufacturing of the HX that can combat oxidation in HRSGs.

36 MATERIALS SCIENCE↗