Search NASA⌕ Search

SEARCH · Search NASA

Results for “GLOVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station, the Crew and Thermal Systems Division at NASA JSC was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms in a simulated space environment versus testing with a full suit. The Dual Glove Box (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 10^-5 Torr with roughing and cryogenic pumps, and a wide range of shroud temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater plates. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through the development of 2 temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA) suits↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA)↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA)↗

A case history in glovebox glove selection

Here, glovebox glove selection for a unique experiment is discussed, including gloves that deteriorated so that they required replacement over the course of experimentation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermogravimetric Characterization of Glovebox Gloves

An experimental project was initiated to characterize mass loss when heating different polymer glovebox glove material samples to three elevated temperatures, 90, 120, and 150 C. Samples from ten different polymeric gloves that are being considered for use in the tritium gloveboxes were tested. The intent of the study was to determine the amount of material lost. These data will be used in a subsequent study to characterize the composition of the material lost.

08 HYDROGEN↗

Glovebox Glove Characterization Summary

A task was undertaken to determine primarily the permeation behavior of various glove compounds from four manufacturers. As part of the basic characterization task, the opportunity to obtain additional mechanical and thermal properties presented itself. Consequently, a total of fifteen gloves were characterized for permeation, Thermogravimetric Analysis, Puncture Resistance, Tensile Properties and Dynamic Mechanical Analysis. Detailed reports were written for each characterization technique used. This report contains the summary of the results.

36 MATERIALS SCIENCE↗

Dismantling of the PETRA glove box: tritium contamination and inventory assessment

The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followed by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas purged dry box glove Patent

Gas purged dry box glove reducing permeation of air or moisture into dry box or isolator by diffusion through glove

Herbell, T. P.↗

High pressure space suit glove

The High Pressure Space Suit Glove Program yielded one prototype glove assembly with an operating pressure of 8.0 psi. The following developments are reported: (1) A new layup technique for incorporation of the mini-convolute systems; (2) modification in the mini-convolute construction to assure cycle life at 8.0 psi in excess of 100,000 cycles; (3) the development of a unique non-orthogonal low torque wrist joint; (4) the development of a low torque single axis joint for use in the thumb and finger first metacarpal joints; and (5) a number of approaches to 1st metacarpal joints were fabricated and tested to establish the joint technqiues.

Elkins, W.↗

Prediction of in-depth gap heating ratios from wing glove model test data

In-depth gap heating ratios were predicted down RSI tile sidewalls based on temperature measurements obtained from the JSC arc-jet Wing Glove model tests in order to develop gap heating ratios which resulted in the best possible fit of test data and to produce a set of engineering verification heating ratios similar in shape to one another which could be used at various body points on the Orbiter during reentry. The Rockwell TPS Multidimensional heat conduction program was used to perform 3-D thermal analyses using a 3.0 in. thick section of a curved RSI tile with 283 nodal points. Correlation with test data shows that the predicted heating ratios were significantly higher down in the gap than the zero pressure values for T/C stacks 39 and 38 on the Wing Glove model. For stack 37 (in a low pressure region), the baseline heating ratio overpredicted the temperature data. This analysis, which showed that the heating ratios were a strong function of the product of pressure and pressure gradient, will be used to compare with recent Gap/Step and Ames Double Wedge test/analysis results in the effort to identify the Orbiter gap response to high delta P flight environment.

Source record↗

Thermally Insulated Glove With Good Tactility

Thermally insulated glove contains short, closely-spaced elastomeric pins that insulate without impairing flexibility. By confining pins to the inter-joint areas of palm, fingers and back of the hand, joint mobility is retained. Glove thermal-insulation requirements dictate the relationships among pin length, pin diameter, and number of pins per unit surface length.

Balinskas, R.↗

Boundary layer stability analysis of a natural laminar flow glove on the F-111 TACT airplane

A natural laminar flow airfoil has been developed as a part of the aircraft energy efficiency program. A NASA flight program incorporating this airfoil into partial wing gloves on the F-111 TACT airplane was scheduled to start in May, 1980. In support of this research effort, an extensive boundary layer stability analysis of the partial glove has been conducted. The results of that analysis show the expected effects of wing leading-edge sweep angle, Reynolds number, and compressibility on boundary layer stability and transition. These results indicate that it should be possible to attain on the order of 60% laminar flow on the upper surface and 50% laminar flow on the lower surface for sweep angles of at least 20 deg, chord Reynolds numbers of 25 x 10 to the 6th and Mach numbers from 0.81 to 0.85.

Runyan, L. J.↗

F-111 natural laminar flow glove flight test data analysis and boundary layer stability analysis

An analysis of 34 selected flight test data cases from a NASA flight program incorporating a natural laminar flow airfoil into partial wing gloves on the F-111 TACT airplane is given. This analysis determined the measured location of transition from laminar to turbulent flow. The report also contains the results of a boundary layer stability analysis of 25 of the selected cases in which the crossflow (C-F) and Tollmien-Schlichting (T-S) disturbance amplification factors are correlated with the measured transition location. The chord Reynolds numbers for these cases ranges from about 23 million to 29 million, the Mach numbers ranged from 0.80 to 0.85, and the glove leading-edge sweep angles ranged from 9 deg to 25 deg. Results indicate that the maximum extent of laminar flow varies from 56% chord to 9-deg sweep on the upper surface, and from 51% chord at 16-deg sweep to 6% chord at 25-deg sweep on the lower. The results of the boundary layer stability analysis indicate that when both C-F and T-S disturbances are amplified, an interaction takes place which reduces the maximum amplification factor of either type of disturbance that can be tolerated without causing transition.

Runyan, L. J.↗

Development of a Pre-Prototype Power Assisted Glove End Effector for Extravehicular Activity

The purpose of this program was to develop an EVA power tool which is capable of performing a variety of functions while at the same time increasing the EVA crewmember's effectiveness by reducing hand fatigue associated with gripping tools through a pressurized EMU glove. The Power Assisted Glove End Effector (PAGE) preprototype hardware met or exceeded all of its technical requirements and has incorporated acoustic feedback to allow the EVA crewmember to monitor motor loading and speed. If this tool is to be developed for flight use, several issues need to be addressed. These issues are listed.

Source record↗

Sensory substitution for space gloves and for space robots

Sensory substitution systems for space applications are described. Physical sensors replace missing human receptors and feed information to the interpretive centers of a different sense. The brain is plastic enough so that, with training, the subject localizes the input as if it were received through the missing receptors. Astronauts have difficulty feeling objects through space suit gloves because of their thickness and because of the 4.3 psi pressure difference. Miniature force sensors on the glove palm drive an electrotactile belt around the waist, thus augmenting the missing tactile sensation. A proposed teleoperator system with telepresence for a space robot would incorporate teleproprioception and a force sensor/electrotactile belt sensory substitution system for teletouch.

Bach-Y-rita, P.↗

The 757 NLF glove flight test results

A major concern in the application of a laminar flow wing design to commercial transports is whether laminar flow can be sustained in the presence of the noise environment due to wing mounted turbofan engines. To investigate this issue, a flight test program was conducted using the Boeing 757 flight research airplane with a portion of the wing modified to obtain natural laminar flow. The flight test had two primary objectives. The first was to measure the noise levels on the upper and lower surface of the wing for a range of flight conditions. The second was to investigate the effect of engine noise on laminar boundary layer transition. The noise field on the wing and transition location on the glove were then measured as a function of the engine power setting at a given flight condition. The transition and noise measurement on the glove show that there is no apparent effect of engine noise on the upper surface transition location. On the lower surface, the transition location moved forward 2 to 3 percent chord. A boundary layer stability analysis to the flight data showed that cross flow disturbances were the dominant cause of transition at most flight conditions.

Runyan, L. Jim↗

Handling and analysis of ices in cryostats and glove boxes in view of cometary samples

Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.

Roessler, K.↗