Search NASA⌕ Search

SEARCH · Search NASA

Results for “GLOW DISCHARGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Pulsed-discharge carbon dioxide lasers

The purpose is to attempt a general introduction to pulsed carbon dioxide lasers of the kind used or proposed for laser radar applications. Laser physics is an excellent example of a cross-disciplinary topic, and the molecular spectroscopy, energy transfer, and plasma kinetics of the devices are explored. The concept of stimulated emission and population inversions is introduced, leading on to the molecular spectroscopy of the CO2 molecule. This is followed by a consideration of electron-impact pumping, and the pertinent energy transfer and relaxation processes which go on. Since the devices are plasma pumped, it is necessary to introduce a complex subject, but this is restricted to appropriate physics of glow discharges. Examples of representative devices are shown. The implications of the foregoing to plasma chemistry and gas life are discussed.

Willetts, David V.↗

Measurement of temperature of a dusty plasma from its configuration

A new concept called “configurational temperature” is introduced in the context of dusty plasma, where the temperature of the dust particles submerged in the plasma can be measured directly from the positional information of the individual dust particles and the interaction potential between the dust grains. This method does not require the velocity information of individual particles, which is a key parameter to measure the dust temperature in the conventional method. The technique is initially tested using two-dimensional (2D) OpenMP parallel molecular dynamics and Monte Carlo simulation and then compared with the temperature evaluated from experimental data. The experiment have been carried out in the Dusty Plasma Experimental (DPEx) device, where a 2D stationary plasma crystal of melamine formaldehyde particles is formed in the cathode sheath of a DC glow discharge argon plasma. The kinetic temperature of the dust is calculated using the standard particle image velocimetry technique at different pressures. An extended simulation result for the three-dimensional case is also presented, which can be employed for the temperature measurement of a three-dimensional dust crystal in laboratory devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non‐OH‐driven liquid‐phase chemistry in water microdroplets

Abstract Water microdroplets containing organic and fluorinated compounds, such as formate, perfluorooctanoic acid (PFOA) and triflic acid, were exposed to a radiofrequency glow discharge plasma with a droplet residence time on the order of milliseconds. Triflic acid remained unaffected by any plasma condition while >75% decomposition of formate and PFOA could be achieved. In situ hydroxyl (OH)‐laser‐induced fluorescence measurements near the droplets confirmed that the conversion was independent of the OH flux to the droplet. A series of control experiments suggest that the contribution of vacuum UV photons in such decomposition of aqueous compounds can be significant for He and He + 17% Ar plasmas and can also explain unexpected decomposition trends as a function of droplet residence time in the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nitrogen fixation as NO x using air plasma coupled with heterogeneous catalysis at atmospheric pressure

Here, this study presents insights into the use of activated Al 2 O 3 catalysts to improve the energy efficiency of NO x production in atmospheric pressure air plasma. The introduction of catalysts in the direct current glow discharge system reduces the energy cost of NO x production by up to 45% at low gas flow rates. Notably, even when positioned away from the plasma zone, the catalyst enhanced NO x production, suggesting a significant role for the catalytic activation of downstream neutral species. The study also introduced a novel approach involving an air plasma jet infused with floating catalyst powder. This method significantly increased energy efficiency at higher discharge currents, with an associated energy cost of 2.9 MJ/mol for NO x production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding Reproducibility of Sputter‐Deposited Metastable Ferroelectric Wurtzite Al 0.6 Sc 0.4 N Films Using In Situ Optical Emission Spectrometry

High‐Sc Al 1– x Sc x N thin films are of tremendous interest because of their attractive piezoelectric and ferroelectric properties, but overall film quality and reproducibility are widely reported to suffer as x increases. In this study, structural and electrical properties of metastable Al 0.6 Sc 0.4 N films are connected with plasma changes during film growth, identified via glow discharge optical emission spectroscopy (GD‐OES), and linked to the target mode changes. This in situ GD‐OES technique uses changes in the N 2 (I) intensity, correlated with DC bias hysteresis behavior of a Al 0.6 Sc 0.4 target in metallic and poisoned modes, to identify films that subsequently exhibit unacceptable structural and electrical performance. Two representative samples deposited under identical conditions but possessing distinct properties related to phases present in the films are focused on. Films sputtered under a poisoned target mode produce pure wurtzite ferroelectric Al 0.6 Sc 0.4 N with a reversible 80 μC cm −1 polarization and 3.1 MV cm −1 coercive field. When identical chamber settings are used but the process starts in metallic mode, a mixed wurtzite/rocksalt film is deposited which exhibits nanometer‐scale changes to the film microstructure and a nonferroelectric response. These results illustrate the utility of optical emission spectroscopy for tracking target mode fluctuations when fabricating metastable materials such as high‐Sc Al 1– x Sc x N films.

36 MATERIALS SCIENCE↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Impurity Levels in Cerium Oxide Microspheres Prepared by Internal Gelation Sol-Gel Methods

Impurity levels were measured in cerium oxide microspheres fabricated by modified internal gelation sol-gel methods. A combination of glow discharge mass spectrometry, electron impact mass spectrometry, combustion gas analysis and instrumental gas analysis were used to assess a wide range of potential elemental impurities. Low concentrations of carbon, nitrogen, and hydrogen impurities in microspheres showed a dependence on how microspheres were washed. Silicon impurities are believed to derive from silicone oil used during sol-gel processing. Spheres washed by the preferred approach had impurity levels below 100 ppm for all elements tested. For applications such as nuclear fuels, sol-gel methods could meet purity specifications as long as metal nitrate feed solutions of sufficient purity are used and microspheres are washed appropriately. In this study, cerium was used as a surrogate for plutonium-238, which is used in radioisotope power systems as a heat source, to determine whether carbon or other impurities were concentrated during internal gelation processing and remained after heat treatments. Analyses indicated low concentrations of impurities in cerium oxide microspheres after sintering steps that were well below documented limits for plutonium-238 oxide fuels. Modified washing methods, combined with a pressurized water treatment, resulted in sintered cerium oxide sol-gel microspheres with low impurity levels.

cerium oxide, sol-gel, internal gelation, microsph↗

Investigation of potential polyatomic interferences on uranium isotope ratio measurements for the LS-APGD-Orbitrap MS system

The determination of actinide (e.g., U and Pu) content and isotopics is of importance to the nuclear forensics and safeguards communities. However, in the analysis of environmental samples, such as those collected by the International Atomic Energy Agency, uranium measurements can be complicated by isobaric interferences from polyatomic variants of heavy elements (e.g., Pb). This leads to complex, time-consuming sample manipulations (i.e., separations) before determining isotope ratios. An alternative strategy to sample pretreatment is to use high-resolution mass spectrometric platforms during the analysis to fully resolve the uranium isotopes from potential polyatomic interferences, negating the need for prior chemical separation. The liquid sampling - atmospheric pressure glow discharge (LS-APGD) coupled with an Orbitrap mass spectrometer provides a high-resolution (>70,000 m/Δm at m/z 200) inorganic mass spectrometry platform. Further, as a demonstration of the power of this instrumental platform, and indeed, the high-resolution approach in general, uranium isotope ratios were determined in the presence of elemental impurities (e.g., Pb, Pt, Ta, W) commonly encountered with environmental sample swipe analysis, without any prior treatment. Even at elemental impurity concentrations of 1000–5000× relative to uranium, no interference was observed with the 235 U or 238 U signal. In addition, the 235 U/ 238 U isotope ratio for the samples with the concomitants present are within 2 standard deviations of the values obtained without their addition, indicating that these impurities do not impact the determined uranium isotope ratio. These findings represent a significant first step in leveraging the high resolution of the LS-APGD-Orbitrap-MS to overcome isobaric and molecular interferences instead of relying on chemical separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Initial design concepts for solid boron injection in ITER

As part of ITER’s consideration to change its first wall material from beryllium to tungsten, the ITER Organization has proposed studying the feasibility of real-time solid boron injection (SBI) into the plasma to coat the walls and divertor to supplement glow discharge boronization (GDB). Boron deposits getter oxygen and reduce sputtering of tungsten from plasma facing components (PFCs). Particularly in areas with significant plasma wall interactions, boron coatings are expected to be short-lived under high performance plasma conditions. The proposed SBI system aims to maintain boron layers in these areas to avoid excessive radiation from tungsten in the plasma as a risk mitigation to ensure ITER will be able to reach and sustain Q = 10 conditions. The system will be used sparingly, as redeposition of boron can lead to significant tritium retention, which must be minimized in ITER to comply with nuclear safety concerns. SBI is proposed to limit and precisely control the amount of boron injected in real-time during plasma operation. Here, some of the design requirements and initial concepts for an SBI system in ITER are presented based on previous results carried out with SBI systems on a number of tokamaks and stellarators around the world. Previous results using SBI systems installed by PPPL have injected boron particles from 5 µm–2 mm diameter at calibrated rates of 2–200 mg/s in real-time during plasma operation on AUG, DIII-D, EAST, KSTAR, LHD, TFTR, WEST, and W7-X, leading to improved wall conditions with reduced plasma impurity concentrations and radiated power and improved plasma performance. The boron is ionized in the plasma edge and then deposited on plasma-wetted surfaces. On AUG, EAST and WEST reduced tungsten sputtering sources were observed following several discharges with SBI. Extrapolation of these SBI results are presented to estimate the amount of boron needed for wall conditioning in ITER. Real-time SBI control requirements and plasma operation scenarios for ITER are also described.

36 MATERIALS SCIENCE↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Measurement of the properties of the dust acoustic wave in a magnetic field

We present the first experimental observations of the dust acoustic wave where the wave was observed to propagate in the directions of gravity and magnetic field when these directions were not aligned. The experiments were conducted in the Magnetized Dusty Plasma eXperiment facility using a novel electrode system that allows for the angle between gravity and the magnetic field to be varied in a controlled way. This letter reports on measurements in an rf glow discharge argon plasma environment where the angle between direction of gravity and the magnetic field is 45 $^{\circ }$ . When there was no applied magnetic field, the wave was observed to propagate in the direction of gravity. However, as the magnetic field increased and the ions transitioned from flowing in the direction of gravity to the direction of the magnetic field, a second wave emerged and two distinct waves were observed to simultaneously propagate, one in the direction of gravity and one in the direction of the magnetic field. As the magnetic field was further increased, the wave that propagated in the direction of gravity was suppressed and the wave was only observed to propagate in the direction of the applied magnetic field. We also observe that the speed and the kinetic temperature of the dust for the mode that propagated in the direction of gravity decreased with increasing magnetic field while the speed and the kinetic temperature of the dust for the mode that propagated in the direction of the magnetic field increased with increasing magnetic field. These measurements suggest that an ion-dust streaming instability is at least partially responsible for the high temperatures that have previously been observed in dusty plasmas when the dust acoustic wave is present.

Williams, J. D. (ORCID:000000025199707X)↗

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Combining Mass Spectrometry of Picoliter Samples with a Multicompartment Electrodynamic Trap for Probing the Chemistry of Droplet Arrays

Single droplet levitation provides contactless access to the microphysical and chemical properties of micrometer-sized samples. Most applications of droplet levitation to chemical and biological systems use nondestructive optical techniques to probe droplet properties. To provide improved chemical specificity, we coupled a multicompartment quadrupole electrodynamic trap (QET) with single droplet mass spectrometry. Our QET continuously traps a monodisperse droplet population (tens to hundreds of droplets) and allows for the simultaneous sizing of a single droplet using its Mie scattering pattern. Single droplets are subsequently ejected into the ionization region of an ambient pressure inlet mass spectrometer. We optimized two complementary soft ionization techniques for picoliter aqueous droplets: (1) paper spray (PS) ionization and (2) thermal desorption glow discharge (TDGD) ionization. Both techniques detect oxygenated organic acids in single droplets, with signal-to-noise ratios >100 and detection limits on the order of 10 pg. Sensitivity and reproducibility across single droplets are driven by the droplet deposition location and spray stability in PS-MS and the ionization region humidity and analyte evaporation rate in TDGD-MS. Importantly, the analyte evaporation rate can control the TDGD-MS quantitative capability because high evaporation rates result in significant ion suppression. Additionally, this effect is mitigated by optimizing the vaporization temperature, droplet size range, and analyte volatility. We demonstrate quantitative and reproducible measurements with a droplet internal standard (<10% RSD) and compare the sensitivity of PS-MS and TDGD-MS. Finally, we demonstrate the application of QET-MS to the study of heterogeneous chemical kinetics with the reaction of gas phase O 3 and aqueous maleic acid droplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Growth of High-Purity CsPbBr 3 Crystals for Enhanced Gamma-Ray Detection

High-quality CsPbBr 3 crystals hold significant potential for gamma-ray detection due to their remarkable optoelectronic properties. This study details an optimized production process using the Bridgman method to achieve highly pure CsPbBr 3 crystals. By implementing rigorous synthesis and purification techniques, we successfully reduced the total impurity levels to 9 ppm, as confirmed by glow discharge mass spectroscopy (GDMS). The resulting CsPbBr 3 crystals demonstrate exceptional performance, including high transparency, intense photoemission, and prolonged photoluminescence decay times. These properties facilitate superior gamma-ray detection with an energy resolution of 1.4% for the 137 Cs 662 keV gamma-rays, comparable to commercial Cd 1-x Zn x Te (CZT) detectors. Our findings underscore the critical relationship between material purity and detector performance, highlighting the potential of CsPbBr 3 as a cost-effective alternative in radiation detection applications. Further studies on defect origins and electronic states are necessary to fully leverage the capabilities of CsPbBr 3 crystals in practical high-energy radiation detection systems.

Bridgman↗

P-Type Electrochemical Doping Can Occur by Cation Expulsion in a High Performing Polymer for Organic Electrochemical Transistors

We investigate the mechanism of ion-dependent charge compensation during electrochemical oxidation (doping) of the model mixed ionic/electronic transporting polythiophene derivative poly(3-{[2-(2-methoxyethoxy)ethoxy]methyl}thiophene-2,5-diyl) (P3MEEMT). Using a combination of electrochemical quartz microbalance gravimetry and glow discharge optical emission spectroscopy, we show that charge compensation during polymer redox processes proceeds via a cation-dependent mechanism. For p-type polymer oxidation in certain electrolytes, charge compensation is achieved by both eventual injection of anions into the film, as well as initial expulsion of cations from the film. We compare doping mechanisms for a variety of electrolyte salts including potassium chloride, tetrabutylammonium chloride, potassium hexafluorophosphate (KPF6), and tetrabutylammonium hexafluorophosphate. For the electrolyte KPF6, both the cations and anions coexist in the water-swelled polymer even prior to application of electrical bias. Our data indicate that electrochemical doping (hole injection into the polymer and ionic charge compensation) proceeds via the following mechanism: (1) hydration of the neutral film by electrolyte (water, cations, anions), (2) cation (K+) expulsion from the film upon initial application of an oxidative bias, and (3) anion injection into the film at higher oxidation/doping levels (>~2 × 1020/cm3). Understanding the mechanism of charge compensation during the doping process should allow for the design of improved mixed ionic/electronic conductors for use in applications ranging from organic supercapacitors and redox flow batteries to bioelectronic sensors, thermoelectrics, and devices for neuromorphic computing.

Flagg, Lucas Q.↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗