Search NASA⌕ Search

SEARCH · Search NASA

Results for “GRIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Attenuation of arsenic neurotoxicity by curcumin in rats

In view of continued exposure to arsenic and associated human health risk including neurotoxicity, neuroprotective efficacy of curcumin, a polyphenolic antioxidant, has been investigated in rats. A significant decrease in locomotor activity, grip strength (26%) and rota-rod performance (82%) was observed in rats treated with arsenic (sodium arsenite, 20 mg/kg body weight, p.o., 28 days) as compared to controls. The arsenic treated rats also exhibited a decrease in the binding of striatal dopamine receptors (32%) and tyrosine hydroxylase (TH) immunoreactivity (19%) in striatum. Increased arsenic levels in corpus striatum (6.5 fold), frontal cortex (6.3 fold) and hippocampus (7.0 fold) associated with enhanced oxidative stress in these brain regions, as evident by an increase in lipid perioxidation, protein carbonyl and a decrease in the levels of glutathione and activity of superoxide dismutase, catalase and glutathione peroxidase with differential effects were observed in arsenic treated rats compared to controls. Simultaneous treatment with arsenic (sodium arsenite, 20 mg/kg body weight, p.o., 28 days) and curcumin (100 mg/kg body weight, p.o., 28 days) caused an increase in locomotor activity and grip strength and improved the rota-rod performance in comparison to arsenic treated rats. Binding of striatal dopamine receptors and TH expression increased while arsenic levels and oxidative stress decreased in these brain regions in co-treated rats as compared to those treated with arsenic alone. No significant effect on any of these parameters was observed in rats treated with curcumin (100 mg/kg body weight, p.o., 28 days) alone compared to controls. A significant protection in behavioral, neurochemical and immunohistochemical parameters in rats simultaneously treated with arsenic and curcumin suggest the neuroprotective efficacy of curcumin.

60 APPLIED LIFE SCIENCES↗

Grand canonically optimized grain boundary phases in hexagonal close-packed titanium

Grain boundaries (GBs) profoundly influence the properties and performance of materials, emphasizing the importance of understanding the GB structure and phase behavior. As recent computational studies have demonstrated the existence of multiple GB phases associated with varying the atomic density at the interface, we introduce a validated, open-source GRand canonical Interface Predictor (GRIP) tool that automates high-throughput, grand canonical optimization of GB structures. While previous studies of GB phases have almost exclusively focused on cubic systems, we demonstrate the utility of GRIP in an application to hexagonal close-packed titanium. We perform a systematic high-throughput exploration of tilt GBs in titanium and discover previously unreported structures and phase transitions. In low-angle boundaries, we demonstrate a coupling between point defect absorption and the change in the GB dislocation network topology due to GB phase transformations, which has important implications for the accommodation of radiation-induced defects.

36 MATERIALS SCIENCE↗

Efficacy of Low Level Laser Therapy After Hand Flexor Tendon Repair

Flexor tendon injury is a common problem requiring suturing repair followed by early postoperative mobilization. Muscle atrophy, joint stiffness, osteoarthritis, infection, skin necrosis, ulceration of joint cartilage and tendocutaneous adhesion are familiar complications produced by prolonged immobilization of surgically repaired tendon ruptures. The purpose of this study was to clarify the importance of low level laser therapy after hand flexor tendon repair in zone II. Thirty patients aging between 20 and 40 years were divided into two groups. Patients in group A (n = 15) received a conventional therapeutic exercise program while patients in group B (n = 15) received low level laser therapy combined with the same therapeutic exercise program. The results showed a statistically significant increase in total active motion of the proximal and distal interphalangeal joints as well as maximum hand grip strength at three weeks and three months postoperative, but improvement was more significant in group B. It was concluded that the combination of low level laser therapy and early therapeutic exercises was more effective than therapeutic exercises alone in improving total active motion of proximal and distal interphalangeal joints and hand grip strength after hand flexor tendon repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monitoring ground anchor using non-destructive ground anchor integrity test (NDT-GRANIT)

Monitoring at ground anchor commonly uses a pull out test method, therefor we developing a non-destructive ground anchor integrity testing (NDT-GRANIT). NDT-GRANIT using the principle of seismic waves that have been modified into form of sweep signal, the signal will be demodulated, filtered, and Fourier transformation (inverse discrete Fourier transform) so the data can be interpreted reflected wave from the ground anchor. The method was applied to determine whether the ground anchor still gripped in the subsurface by looking the attenuation of the wave generated sources. From the result we can see that ground anchor does not grip. To validate the results of the comparison method of measurement used pile integrity test.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of the loading system on mode I delamination results in Carbon-Epoxy composites

In this paper, a modified mechanical grip fitting is used to perform double cantilever beam (DCB) tests. The advantage of using mechanical grips instead of piano hinges or end blocks lies in the fact that the use of adhesive bonding is not required to fix the sample. Adhesive bonding can be an important source of uncertainty and unexpected debondings in fatigue tests. Mechanical fittings are also well suited for high temperature applications where adhesive bonds usually undergo premature failure. An experimental programme has been developed in order to compare the performance of the modified mechanical hinges with classical hinges and end blocks. The highest G{sub Ic} values and scattering were found for the end block system, while hinges and mechanical hinges furnished similar results. The material used to perform the experimental study was a Hexcel AS4/3501-6 unidirectional laminate.

36 MATERIALS SCIENCE↗

NASA COR

This report fulfills the NASA statement of work, (request number NNL10AA061) as amended by Lorie R. Grimes-Ledesma via a post-visit e-mail dated July 13, 2012. The statement of work and subsequent e-mail are included in this report, which includes: • Parts list spreadsheet for load frames by account code. • Available information regarding procurement of elevated temperature ovens. • Grip and strand information. • Copy of the presentation made at Cobham, (December 2010). • Review comments to strand and grip installation procedure as provided by NASA. The shipping plan and shipment determinations were developed and shared with Lorie R. Grimes-Ledesma shortly after receiving her e-mail, July 13, 2012.

36 MATERIALS SCIENCE↗

Report on the FY20 Characterization of Age Hardened Alloy 709 Materials

This report provides the results on microstructural characterization of the first commercial heat of Alloy 709 plate material undergone additional age hardening treatment. In FY19, through thermodynamic-kinetic modeling and microstructural characterization, it is determined that the 775°C/10 h age-hardening treatment can promote desired precipitation on dislocations and has the potential to further improve the mechanical performance of the material. In FY20, the treatment protocol was applied to the ESR-1150°C condition, and the microstructure was then compared with the ESR-1100°C condition. It was found that the 1150°C solution annealing (SA) dramatically reduced the dislocation density compared to the 1100°C SA, resulting a smaller number density of Nb-rich fine precipitates which grow on dislocations during the age hardening treatment. Other features are very similar between the two. The effect of age hardening on creep performance is discussed. In addition, TEM characterization of a creep-ruptured sample (600°C/330 MPa) was performed. Specimens from the grip region and the gauge region was studied. The grip region specimen was effectively aged at 600°C for extended period, while the gauge region specimen was mechanically deformed at 600°C. The microstructures are very different, implying the importance of a dynamical effect on precipitation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PMK 1000 cone-socket ventilator fittings force testing to ISO 5356-1:2015 Standard

This memo summarizes the results of verification tests on a cone-socket fitting to the ISO 5356-1:2015 standard, annexes B and F. The components were found to meet requirements holding 50N tensile force and more than 35 N-cm of torque for 10 seconds without separating at 35°C with a fresh socket. Humidity control was unavailable; consequently, humidity was significantly lower than the values in the ISO standard. Several repeat tests of the fitting with force, torque, and time excursions give us confidence that the fittings perform suitably to the ISO standard. Force overload tests suggest that the samples will disengage under tension at around 69 N, while torque overload tests under a force of 50 N will fail at 79 N-cm of torque. If repeated tests are performed on the same component, the socket can deform and lead to the connection failing the standard requirements. However, such failures only occur with repeated testing, and the gripping of such units can be modified so that they pass the standard. This observation demonstrates that socket gripping is responsible for those failures and would not be a problem in application.

42 ENGINEERING↗

Assessment of Potential Ergonomic Injury Risk in the Nuclear Material Processing Glovebox Environment [Capstone Project]

Gloveboxes are isolation barriers that are used within many different industries such as pharmaceuticals, electronic parts fabrication, nuclear, and biological. The research on glovebox ergonomics is currently limited with few ergonomic professionals that focusing exclusively on glovebox working environments. There is existing documentation on occupational injuries, such as musculoskeletal disorders (MSD), sustained as a direct result of working in gloveboxes. The main elements that pose ergonomic risks to glovebox workers are operational repetition, duration, force, vibration, lifting heavy (more than 15lbs with two hands) objects, and awkward postures. This paper examines a small sample of the potential causal or risk factors that lead to the ergonomic injuries. A meta-analysis utilizing a random effect model is used to examine data from several studies which focus on, dexterity and strength changes as result of glove thickness, and robotic assistive technology as a means to improve postural mechanics. With the meta-analysis technique, similar data sets from different research studies can be coalesced into a single weighted, statistically significant result for subsequent consideration. The results from the analysis show that increased glove thickness results in decreased dexterity for operators thus increasing ergonomic risk factors such as task duration. It is also shown that glove thickness decreases grip strength but a similar decrease in pinch strength is not definitively demonstrated. With decreased grip strength, operators will need to exert more force (a known ergonomic risk factor) on processing tools, etc. during operations thus increasing the risk of ergonomic injury. The use of robotic assistive technology as a means to improve operator posture (risk factor) was also examined. Although it may be intuitively assumed that human-robotic collaboration would be beneficial in reducing risk factors, the result from this study’s analysis was not statistically significant. It is inferred that with additional directed research on this topic another study/analysis could be statistically significant demonstrating the benefits of the technology.

99 GENERAL AND MISCELLANEOUS↗

Tactile Identification of a Surface by Fuzzy Control

A hybrid control system has been developed for an anthropomorphic gripping device capable of grasping an object whose physicomechanical and geometric characteristics are unknown. The surface is identified on the basis of a multiply connected inverse pendulum, simulating the hand of a gripping device. A fuzzy control algorithm is synthesized for a two-level hybrid automatic control system.

42 ENGINEERING↗

Development of an Innovative Inspection Tool for Superheater Tubes in Fossil Fuel Power Plants

Fossil fuel power plants are complex systems containing multiple components that require periodic health monitoring. Failures in these systems can lead to increased downtime for the plant, reduction of power, and significant cost for repairs. Inspections of the plant’s superheater tubes are typically manual, laborious, and extremely time-consuming. This is due to their small diameter size (between 1.3 and 7.6 cm) and the coiled structure of the tubing. In addition, the tubes are often stacked close to each other, limiting access for external inspection. This paper presents the development and testing of an electrically powered pipe crawler that can navigate inside 5 cm diameter tubes and provide an assessment of their health. The crawler utilizes peristaltic motion within the tubes via interconnected modules for gripping and extending. The modular nature of the system allows it to traverse through straight sections and multiple 90° and 180° bends. Additional modules in the system include an ultrasonic sensor for tube thickness measurements, as well as environmental sensors, a light detecting and ranging (LiDAR) sensor, and camera. Furthermore, these modules utilize a gear system that allows for 360° rotation and provides a means to inspect the entire internal circumference of the tubes.

36 MATERIALS SCIENCE↗

Folding tools for flat conductor cable harnesses

Vise grip pliers have detachable metal gripping plates which are changed to accommodate cables from 1 to 3 in. wide and to form any desired fold angle. A second tool squeezes cable along crease to complete the fold.

Loggins, R.↗

High-temperature tensile tester for ceramics

Apparatus measures tensile strength of rigid, low-density ceramic materials at temperatures up to 1375 K. Tensile grips mate with tensile specimen and form top and bottom of lightweight furnace. Apparatus can only be used with rigid materials and grips must be stronger than material under test.

Smith, M.↗

Design and fabrication of an end effector

The construction is described of a prototype mechanical hand or 'end effector' for use on a remotely controlled robot, but with possible application as a prosthetic device. An analysis of hand motions is reported, from which it is concluded that the two most important manipulations (apart from grasps) are to be able to pick up a tool and draw it into a nested grip against the palm, and to be able to hold a pistol-grip tool such as an electric drill and pull the trigger. A model was tested and found capable of both these operations.

Crossley, F. R. E.↗

Design for a three-fingered hand

This paper describes the construction of a prototype mechanical hand or 'end effector' for use on a remotely controlled robot, but with possible application as a prosthetic device. An analysis of hand motions is reported, from which it is concluded that the two most important manipulations (apart from grasps) are to be able to pick up a tool and draw it into a nested grip against the palm, and to be able to hold a pistol-grip tool such as an electric drill and pull the trigger. One of our models was tested and found capable of both these operations.

Crossley, F. R. E.↗

Edgeless composite laminate specimen for static and fatigue testing

The influence of edge effects on the tensile properties of angle-ply laminate composites can be eliminated by using edgeless (round tubular) specimens. However, uniaxial tests with such specimens, static and fatigue, have been generally unsuccessful because of the differential Poisson effect between the test section and the grips. An edgeless cylindrical specimen, developed to circumvent these difficulties, is examined in the present paper. It is a flattened tube consisting of two flat sides connected by curved sections. It can be handled much like the standard flat coupon. The flat ends of the specimen are provided with crossplied fiberglass gripping tabs, the same as used for flat test coupons. As part of the tabbing, the hollow ends must be plugged with inserts to prevent crushing of the ends. A special insert design was developed to minimize detrimental Poisson effects ordinarily introduced by inserts.

Liber, T.↗

Fracture modes and acoustic emission of composite materials

Unidirectional fibrous composite material laminae are the construction material of a laminate. Four failure modes can occur in this material, and the identification of these modes is as important as the identification of onset of fracture. Acoustic emission (AE) pulses, generated by the change in the stress field resulting from cracking in a material, have a unique pattern of amplitude distribution that depends only on the mode of fracture and the type of material. By using a tapered double-cantilever beam as grips for the unidirectional lamina, a crack with a constant stress intensity factor was induced, thus eliminating the factor of the stress level. Placing the lamina in different directions relative to the grips imposed a different failure mode. By plotting the log of the relative number of AE pulses above some level versus the log of the relative level, a single constant coefficient can be measured for each material and mode of fracture. The AE energy is proportional to the energy released by the cracking; this proportionality depends on the medium where the AE waves have to travel, and not on the cracking mode.

Rotem, A.↗

Wrench for smooth or damaged fasteners

Smooth-surfaced or damaged fasteners that cannot be gripped by conventional wrench can be unscrewed by special wrench. It can be used in tight spaces and will not damage adjacent structures. Wrench consists of central handle and 2 independent jaws with serrated teeth. Teeth are placed on fastener to be removed, and handle is rotated until fastener is gripped with positive locking action. Rotation of wrench handle removes fastener.

Carrillo, R.↗