Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

Update on Radiochemical Assessment of High Burnup Commercially Irradiated Fuel

This work documents an effort to collect burnup measurements on a high burnup rod, designated 6XV, and first cycle accident tolerant fuel (ATF) rod, designated 47I, to enable benchmarking of fuel performance codes and neutronics codes. In addition to measurements, Virtual Environment for Reactor Applications (VERA) full-core-depletion analysis was also performed for the rods that were experimentally analyzed to provide an opportunity for code validation. This effort focuses on collecting data from rods irradiated at Byron Generating Station and shipped to the Oak Ridge National Laboratory (ORNL) hot-cells. This data will also anchor non-destructive examination evaluations of burnup of the various fuel rods undergoing postirradiation examination (PIE) at ORNL. Previous PIE of these fuel rods provides some guidance on the burnup trend across the fuel. Axial gamma spectroscopy scans provide a measure of relative changes in burnup across a fuel pin. Mass spectrometry based burnup measurements performed for this work at specific axial locations in the fuel are fully quantitative. By combining the mass spectrometry data with the gamma scans it is possible to more quantitatively evaluate axial variations in burnup across the entire fuel pin [1]. The combined set of burnup evaluations will be made available to other organizations that have an interest in high burnup radiochemistry data for validation of neutronic simulations and source term evaluation such as the Nuclear Regulatory Commission (NRC).

Harp, Jason [Oak Ridge National Laboratory (ORNL),↗

International database of reference gamma spectra for nuclear safeguards applications

Nuclear safeguards missions use gamma spectroscopy as a non-destructive measurement technique for examining nuclear materials. Despite advances in the development of detection equipment as well as software codes, one of the concerns is the lack of well-documented spectra needed to test and validate isotopic analysis codes for their applicability. To address this need, this work introduces IDB, an international database of the reference gamma spectra of uranium, plutonium and mixed oxide nuclear material samples. IDB provides access to well-characterized sets of gamma spectra described by rich metadata, including information on the sample, measurement configuration and detector specifications. These spectra are accessible in different formats, also compatible with analysis code standards, thus promoting their sustainability and maintenance.

None, Dipti [International Atomic Energy Agency (I↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thorium chelators for targeted alpha therapy: Rapid chelation of thorium-226

We report one of the main challenges in targeted alpha therapy is assuring delivery of the α-particle dose to the targeted cells. Thus, it is critical to identify ligands for α-emitting radiometals that will form complexes that are very stable, both in vitro and in vivo. In this investigation, thorium-227 (t 1/2 = 18.70 days) chelation of ligands containing hydroxypyridinonate (HOPO) or picolinic acid (pa) moieties and the stability of the resultant complexes were studied. Chelation reactions were followed by reversed-phased HPLC and gamma spectroscopy. Studies revealed that high 227 Th chelation yields could be obtained within 2.5 h or less with ligands containing four Me-3,2-HOPO moieties, 1 (83%) and 2 (65%), and also with ligands containing pa moieties, H 4 octapa 3 (65%) and H 4 py4pa 6 (87%). No reaction occurred with H 4 neunpa-p-Bn-NO 2 4, and the chelation reaction with another pa ligand H 4 pypa 5 gave inconsistent yields with a very broad radio-HPLC peak. The ligands spermine-(Me-3,2-HOPO) 4 1, H 4 octapa 3, and H 4 py4pa 6 had high stability (i.e., 87% of 227 Th still bound to the ligand) in phosphate-buffered saline at room temperature over a 6-day period. Preliminary studies with ligand 6 demonstrated efficient chelation of thorium-226 (t 1/2 = 30.57 min) when heated to 80°C for 5 min.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a separation method for rare earth elements using LN resin

The lanthanide elements and isotopes are analytes of significant interest for several nuclear-related fields. Chemical separation among these elements is uniquely challenging due to their nearly identical chemical properties. This difficulty in interelement separation can create obstacles for quantitative radiometric analysis, specifically for isotopes without distinct energy emissions easily measured by gamma spectroscopy, for example Tb-161. Presented in this work is an optimized method for the isolation of individual rare earth elements using Eichrom’s LN resin.

Arrigo, Leah M.↗

Age determination of a 75 Se gamma radiography source for nuclear forensics

Here, two methods were used to evaluate the age of 75 Se sealed source material. Both methods utilized gamma spectroscopy to determine the quantity of parent 75 Se present, but they differed in the technique used to determine the quantity of daughter 75 As. In one method, 75 As was quantified using inductively coupled plasma-mass spectrometry (ICP-MS) after using chromatographic techniques to separate the parent and daughter isotopes. In the other method, total As was measured using optical emission spectroscopy (OES), which did not require separation prior to measurement. The OES method was faster and gave slightly lower uncertainties, but required more daughter material to be present because of higher concentration requirements, making it unsuitable for young material. Both methods are hampered by the monoisotopic nature of As, but still gave reasonable model ages that were in agreement with each other.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Synthesis of americium trichloride via chlorination of americium oxide using zirconium tetrachloride in LiCl-KCl molten salt

To better inform electrorefining operations of used nuclear fuel, a fundamental understanding of the electrochemical properties of each actinide in the molten salt electrolyte is needed. Access to actinide chlorides is thus required to support measurement of these properties. In this work, we synthesized americium trichloride through a novel pathway comprising chlorination of Am2O3 with ZrCl4 in a LiCl-KCl molten salt at 500 degrees C. The formation of AmCl3 was confirmed by cyclic voltammetry and gamma spectroscopy. This chlorination method does not produce mixed hazardous-radioactive waste and the byproduct, ZrO2, is not electrochemically active and does not affect the actinide electrodeposition reaction.

actinide chloride synthesis↗

Radiochemical transport analysis of gamma spectroscopic data to support estimation of molten salt reactor off-gas inventories

This work introduces a novel application of radiochronometry to estimate nuclide inventories in molten salt reactor off-gas systems based on gamma spectroscopic data from the Molten Salt Reactor Experiment. By analyzing isotopic, isobaric, and isomeric activity ratios, key depletion model parameters related to species transport within the reactor system could be inferred. The findings demonstrate the potential of leveraging a limited subset of gamma spectroscopy measurements to accurately estimate nuclide inventories throughout the off-gas system. The approach can be useful in reactor design activities and support analyses relevant to operations, safety, security, and safeguards.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A heavy-ion production channel of 149 Tb via 63 Cu bombardment of 89 Y

We report the radionuclide 149 Tb (t 1/2 = 4.1 h) is a potential theranostic isotope which can simultaneously be used for targeted-alpha-particle therapy and positron-emission tomography. Feasibility experiments were performed to test a near-symmetric heavy-ion reaction of 63 Cu bombardment on monoisotopic 89 Y. The indirect reaction was studied to avoid isomer production. Offline gamma spectroscopy was used to quantify thick-target physical yields and experimental results show modest agreement to the fusion-evaporation code PACE4. A near-symmetric fission yield was also observed.

149Tb↗

Sim-to-real supervised domain adaptation for radioisotope identification

Machine learning has the potential to improve the speed and reliability of radioisotope identification using gamma spectroscopy. However, meticulously labeling an experimental dataset for training is often prohibitively expensive, while training models purely on synthetic data is risky due to the domain gap between simulated and experimental measurements. In this research, we demonstrate that supervised domain adaptation can substantially improve the performance of radioisotope identification models by transferring knowledge between synthetic and experimental data domains. We consider two domain adaptation scenarios: (1) a simulation-to-simulation adaptation, where we perform multi-label proportion estimation using simulated high-purity germanium detectors, and (2) a simulation-to-experimental adaptation, where we perform multi-class, single-label classification using measured spectra from handheld lanthanum bromide (LaBr) and sodium iodide (NaI) detectors. We begin by pretraining a spectral classifier on synthetic data using a custom transformer-based neural network. After subsequent fine-tuning on just 64 labeled experimental spectra, we achieve a test accuracy of 96% in the sim-to-real scenario with a LaBr detector, far surpassing a synthetic-only baseline model (75%) and a model trained from scratch (80%) on the same 64 spectra. Furthermore, we demonstrate that domain-adapted models learn more human-interpretable features than experiment-only baseline models. Overall, our results highlight the potential for supervised domain adaptation techniques to bridge the sim-to-real gap in radioisotope identification, enabling the development of accurate and explainable classifiers even in real-world scenarios where access to experimental data is limited.

Lalor, Peter W.↗

Crystal Growth and Characterization of Europium-Doped Rubidium Calcium Bromide Scintillators

National security strategies like gamma spectroscopy and high-energy X-ray radiography are limited, in part, by the scintillator used, prompting research into novel materials with improved properties. In this paper, Eu 2+ activated rubidium calcium bromide scintillators were grown via the vertical Bridgman method with a range of dopant concentrations. Light yield, energy resolution, and the afterglow of Rb 4 CaBr 6 :Eu and RbCaBr 3 :Eu improved with increasing Eu 2+ concentration, and scintillation decay time increased. The highest light yields of Rb 4 CaBr 6 :Eu and RbCaBr 3 :Eu were 71000 and 45000 ph/MeV, respectively.

36 MATERIALS SCIENCE↗

2025 Annual INMM Graph and Tables for High Purity Germanium Detector Normalization Presentation

The data set includes gamma spectroscopy peak data for measurements taken with two different high purity germanium detectors using a mixed nuclide source and a U-235 fuel rod. There are a total of 5 specific energy peaks that were analyzed for the mixed nuclide source stemming from Am-241, Cd-109, Cs-137, and Co-60. There are a total of 3 specific energy peaks that were analyzed for the U-235 fuel rod. The data set includes the calculations and results from using a linear correction factor, absolute efficiency curve, and relative efficiency curve to compare the net peaks counts from two different detectors.

Drumm, Natalie Daphne [Sandia National Laboratorie↗

Peak Map

Peak Map is a software tool that allows users to generate nuclide library files for gamma spectroscopy from a nuclear data reference. SAND2019-15220 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Leonard, Elliott↗

IDB Loader

SAND2024-08428O The IDB Loader is a database designed to hold gamma spectra. IDB is a web-accessible database of reference gamma spectra for measuring uranium (U) and plutonium (Pu) isotopic composition. The database, developed by the International Atomic Energy Agency (IAEA), provides access to well-characterized groups of gamma spectra curated by international experts in gamma spectroscopy. It was created to promote sustainability and maintenance of software used to determine the isotopic abundances of U and Pu. The IDB Loader works by uploading one set of spectral data into an existing IDB. The Data Loader package includes documentation describing the IDB's table, the format of the spectral data, and a description of the loader program. The IDB is currently hosted by the IAEA at: https://nds.iaea.org/idb Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Schwartz, Steven↗

Comparison and investigation of production of specific nuclides by different fission yield data

Generally, passive gamma spectroscopy (PGS) is known as a useful technique for nondestructive measurement of burnup and nuclide production in normal spent nuclear fuel. However, PGS can be used not only for normal spent fuel, but also for molten fuel generated in severe accidents involving core meltdowns. In such cases, it is estimated by the radioactivity ratios of specific nuclides. At the time of the decommissioning of the Three Mile Island's unit 2 reactor, fission products (FPs) such as Cs{sup 134}, Cs{sup 137}, Ce{sup 144}, Eu{sup 154}, Ru{sup 106}, and Sb{sup 125} were concerned. The radioactivity ratios are estimated by numerical simulations. However, there are various uncertainties in numerical simulations. In this study, we evaluated the effect of the difference in fission yield data. We compared the productions of concerned nuclides of Three Mile Island's unit 2 reactor by using Tokyo-tech and JENDL FP Fission Yields Data File 2011(FPY- 2011). Tokyo-tech is newly created by Tsubakihara et al. at Tokyo Institute of Technology. FPY-2011 is currently the latest fission yield data in Japan. In the concerned nuclides, the relative difference (Tokyo-tech/FPY-2011 -1) in the production of Sb{sup 125} is 4.5% and that of Eu{sup 154} is -5.6%. The relative difference in the production of Sb{sup 125} is found to be caused by the difference in the independent yields of Sn{sup 125}, In{sup 125}, Cd{sup 125}, Ag{sup 125}, and Pd{sup 125}. The relative difference in Eu{sup 154} is found to be caused by the relative difference in the production of Sm{sup 152} and the relative difference in the cumulative yield of Eu{sup 153}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗