Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas sample analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Experimental studies of glass refining

The basic components of the experimental apparatus were selected and acquired. Techniques were developed for the fabrication of the special crucibles necessary for the experiments. Arrangements were made for the analysis of glass and gas bubble samples for composition information. Donations of major equipment were received for this project from Owens, Illinois where a similar study had been conducted a few year ago. Decisions were made regarding the actual glass composition to be used, the gas to be used in the first experiments, and the temperatures at which the experiments should be conducted. A microcomputer was acquired, and work was begun on interfacing the video analyzer to it.

Subramanian, R. S.↗

Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

Wei, Jianjun↗

The Mineralogical and Chemical Case for Habitability at Yellowknife Bay, Gale Crater, Mars

Sediments of the Yellowknife Bay formation (Gale crater) include the Sheepbed member, a mudstone cut by light-toned veins. Two drill samples, John Klein and Cumberland, were collected and analyzed by the CheMin XRD/XRF instrument and the Sample Analysis at Mars (SAM) evolved gas and isotopic analysis suite of instruments. Drill cuttings were also analyzed by the Alpha Particle X-ray Spectrometer (APXS) for bulk composition. The CheMin XRD analysis shows that the mudstone contains basaltic minerals (Fe-forsterite, augite, pigeonite, plagioclase), as well as Fe-oxide/hydroxides, Fe-sulfides, amorphous materials, and trioctahedral phyllosilicates. SAM evolved gas analysis of higher-temperature OH matches the CheMin XRD estimate of ~20% clay minerals in the mudstone. The light-toned veins contain Ca-sulfates; anhydrite and bassanite are detected by XRD but gypsum is also indicated from Mastcam spectral mapping. These sulfates appear to be almost entirely restricted to late-diagenetic veins. The sulfate content of the mudstone matrix itself is lower than other sediments analyzed on Mars. The presence of phyllosilicates indicates that the activity of water was high during their formation and/or transport and deposition (should they have been detrital). Lack of chlorite places limits on the maximum temperature of alteration (likely <100 C). The presence of Ca-sulfates rather than Mg- or Fe-sulfates suggests that the pore water pH was near-neutral and of relatively low ionic strength (although x-ray amorphous Mg-and Fe- sulfates could be present and undetectable by CheMin). The presence of Fe and S in both reduced and oxidized states represents chemical disequilibria that could have been utilized by chemolithoautotrophic biota, if present. When compared to the nearby Rocknest sand shadow mineralogy or the normative mineralogy of Martian soil, both John Klein and Cumberland exhibit a near-absence of olivine and a surplus of magnetite (7-9% of the crystalline component). The magnetite is interpreted as an authigenic product formed when olivine was altered to phyllosilicate. Saponitization of olivine (a process analogous to serpentinization) could have produced H2 in situ. Indeed, early diagenetic hollow nodules ("minibowls") present in the Cumberland mudstone are interpreted by some as forming when gas bubbles accumulated in the unconsolidated mudstone. Lastly, all of these early diagenetic features appear to have been preserved with minimal alteration since their formation, as indicated by the ease of drilling (weak lithification, lack of cementing phases), the presence of 20-30% amorphous material, and the late-stage fracturing with emplacement of calcium sulfate veins and minibowl infills, where they were intersected by veins. A rough estimate of the minimum duration of the lacustrine environment is provided by the minimum thickness of the Sheepbed member. Given 1.5 meters, and applying a mean sediment accumulation rate for lacustrine strata of 1 m/1000 yrs yields a duration of 1,500 years. If the aqueous environments represented by overlying strata are considered, such as Gillespie Lake and Shaler, then this duration increases. The Sheepbed mudstone meets all the requirements of a habitable environment: Aqueous deposition at clement conditions of P, T, pH, Eh and ionic strength, plus the availability of sources of chemical energy.

Blake, David Frederick↗

Characterizing the Phyllosilicate Component of the Sheepbed Mudstone in Gale Crater, Mars Using Laboratory XRD and EGA

The Curiosity rover investigated the mineralogy of the Sheepbed mudstone member of the Yellowknife Bay formation in Gale crater. Data from the Chemistry and Mineralogy (CheMin) X-ray diffractometer (XRD) helped identify phyllosilicates in the two drilled samples, John Klein and Cumberland. These patterns showed peaks at low angles, consistent with (001) peaks in 2:1 swelling phyllosilicates [1]. Evolved gas analyses (EGA) by the Sample Analysis at Mars (SAM) instrument of these samples confirmed the presence of phyllosilicates through the release of H2O at high temperatures, consistent with dehydroxylation of octahedral OH in phyllosilicates [2]. CheMin data for the phyllosilicates at John Klein and Cumberland show that they are structurally similar in that their (02l) peaks are near 22.5 deg 2theta, suggesting both samples contain trioctahedral 2:1 phyllosilicates [1]. However, the positions of the (001) peaks differ: the phyllosilicate at John Klein has its (001) peak at 10 Angstroms, whereas the phyllosilicate at Cumberland has an (001) peak at 14 Angstroms. Such differences in (001) dspacings can be ascribed to the type of cation in the interlayer site [3]. For example, large monovalent cations (e.g., K(+)) have low hydration energies and readily lose their H2O of hydration, whereas small divalent cations (e.g., Mg(2+)) have high energies of hydration and retain H2O in the phyllosilicate interlayers [3,4]. The goal of this study is to determine whether differences in the interlayer cation composition can explain the CheMin data from John Klein and Cumberland and to use this knowledge to better understand phyllosilicate formation mechanisms.

Rampe, E. B.↗

Amorphous Phase Characterization Through X-Ray Diffraction Profile Modeling: Implications for Amorphous Phases in Gale Crater Rocks and Soils

The CheMin X-ray diffraction instrument on the Mars Science Laboratory rover has analyzed 18 rock and soil samples in Gale crater. Diffraction data allow for the identification of major crystalline phases based on the positions and intensities of well-defined peaks and also provides information regarding amorphous and poorly-ordered materials based on the shape and positions of broad scattering humps. The combination of diffraction data, elemental chemistry from APXS (Alpha Particle X-ray Spectrometer) and evolved gas analyses (EGA) from SAM (Sample Analysis at Mars) help constrain possible amorphous materials present in each sample (e.g., glass, opal, iron oxides, sulfates) but are model dependent. We present a novel method to characterize amorphous material in diffraction data and, through this approach, aim to characterize the phases collectively producing the amorphous profiles in CheMin diffraction data. This method may be applied to any diffraction data from samples containing X-ray amorphous materials, not just CheMin datasets, but we re-strict our discussion to Martian-relevant amorphous phases and diffraction data measured by CheMin or CheMin-like instruments.

Achilles, C. N.↗

Partially Chloritized Smectites: Analogues of Smectites at Gale Crater, Mars

Characterizing the structure and composition of phyllosilicates is important for interpreting the aqueous history of Mars and identifying potential habitable environments. Smectites and chlorites are the most dominant clay types on Mars, and there is evidence of the presence of smectite/chlorite intergrades. Smectite has been detected at Gale Crater, Mars, via orbital observations and in-situ measurements, in abundances up to approximately 25 weight percentage of bulk rock. John Klein (JK) and Cumberland (CB) were analyzed by the Chemistry and Mineralogy (CheMin) and Samples Analysis at Mars (SAM) evolved gas analysis experiment (EGA) instruments, onboard Mars Science Laboratory (MSL), Curiosity, to distinguish clay mineralogy. John Klein has a collapsed 2:1 smectite with a d-spacing of 10 Angstroms, whereas Cumberland smectite did not fully collapse and has a d-spacing of approximately 13.2 Angstroms. It has been suggested that partial chloritization or ‘pillaring’ could be responsible for the expanded Cumberland smectite because pillaring inhibits the collapse of smectites down to 10 Angstrom, even under the desiccating conditions on the martian surface. Clay minerals have been detected in ancient fluvio-lacustrine rocks throughout Curiosity’s traverse and catalog the changes of the lake water chemistry and diagenetic conditions at Gale Crater, Mars. Investigating clay minerals is important for identifying them on the Martian surface, in particular as Curiosity proceeds into the upcoming Clay-bearing Unit.

Tu, V. M.↗

High-temperature Hydrogen Chloride Releases from Mixtures of Sodium Chloride with Sulfates: Implications for the Chlorine-Mineralogy as Determined by the Sample Analysis at Mars Instrument on the Curiosity Rover in Gale Crater, Mars

Hydrogen chloride releases above 500 °C occurred in several samples analyzed by the Sample Analysis at Mars (SAM) evolved gas analyzer on the Curiosity rover in Gale crater. These have been attributed to reactions between chlorides (original or from oxychlorine decomposition) and water. Some of these HCl releases that peaked below the melting temperature of common chlorides did not co-evolve with oxygen or water, and were not explained by laboratory analog work (Figure 1). Therefore, these HCl releases were not caused by MgCl2 or soley due to reactions between water and melting chlorides. The goal of this work was to explain the HCl releases that did not co-evolve with oxygen or water and occurred below the melting point of common chlorides, which have not been explained by previous laboratory analog work. This work specifically evaluates the role of evolved SO2 in the production of HCl.

Clark, J.V.↗

Evolved Gas Analyses of Mudstones from the Vera Rubin Ridge

The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) rover has been essential in understanding volatile-bearing phases in Gale Crater materials. SAM’s evolved gas analysis mass spectrometry (EGA-MS) has detected H2O, CO2, O2, H2, SO2, H2S, HCl, NO, and other trace gases, including organic fragments, in many samples. The identity and evolution temperature of evolved gases can support CheMin instrument mineral detection and place constraints on trace volatile-bearing phases or phases difficult to characterize with X-ray diffraction (e.g., amorphous phases). For the past ~500 sols, MSL has been exploring the Vera Rubin Ridge (VRR), which exhibits a striking hematite signature in orbital remote sensing data, in order to understand the depositional and diagenetic history recorded in the rocks and how it relates to the underlying Murray Formation. Four rock samples were drilled, one from the Blunts Point Member (Duluth, DU), one from the Pettegrrove Point Member (Stoer, ST), and two from the Jura Member. The Jura Member displays differences in color, summarized as grey and red, and a key goal was to constrain the cause of this color difference and the associated implications for depositional or post-depositional conditions. To investigate, a grey (Highfield, HF) and a red (Rock Hall, RH) Jura sample were drilled. Here we will give an overview of results from SAM EGA-MS analyses of VRR materials, with some comparisons to analyses of samples of the underlying Murray.

McAdam, A. C.↗

Use Of The Operational Air Quality Monitor (AQM) For In-Flight Water Testing Project

A primary requirement for manned spaceflight is Environmental Health which ensures air and water contaminants, acoustic profiles, microbial flora, and radiation exposures within the cabin are maintained to levels needed for crew health and for vehicle system functionality. The reliance on ground analyses of returned samples is a limitation in the current environmental monitoring strategy that will prevent future Exploration missions beyond low-Earth orbit. This proposal attempts to address this shortcoming by advancing in-flight analyses of water and air. Ground analysis of in-flight, air and water samples typically employ vapor-phase analysis by gas chromatography-mass spectrometry (GC-MS) to identify and quantify organic compounds present in the samples. We envision the use of newly-developed direct ionization approaches as the most viable avenue leading towards an integrated analytical platform for the monitoring of water, air, and, potentially bio-samples in the cabin environment. Development of an in-flight instrument capable of analyzing air and water samples would be the logical next step to meeting the environmental monitoring needs of Exploration missions. Currently, the Air Quality Monitor (AQM) on-board ISS provides this specific information for a number of target compounds in the air. However, there is a significant subset of common target compounds between air and water. Naturally, the following question arises, "Can the AQM be used for both air and water quality monitoring?" Previous directorate-level IR&D funding led to the development of a water sample introduction method for mass spectrometry using electrothermal vaporization (ETV). This project will focus on the integration of the ETV with a ground-based AQM. The capabilities of this integrated platform will be evaluated using a subset of toxicologically important compounds.

Macatangay, Ariel↗

Application of Long-Path Gas Cell Assisted Infrared Spectroscopy for Detection of Lunar Volatiles and Advanced Curation Efforts

The motivation behind analyzing gaseous samples from the Permanently Shadowed Regions (PSRs) on the lunar surface is built upon the volatiles observed during the LCROSS mission. Advanced curation techniques under cold conditions are essential to the critical scientific analysis of these returned samples. The detection of various volatiles in returned samples by gas-phase infrared (IR) spectroscopy is known to be a powerful tool to understand the resources present in planetary bodies and Astro-materials. The identification and quantification of volatile compounds in returned planetary samples and regolith simulants by advanced and custom-built analytical devices are areas of primary research interest in our group and the Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility. In this context, we discuss recent advancements and experimental results for quick analysis of the major volatiles detected by the LCROSS (water, CO 2 , CH 3 OH, and NH 3 ) by a long-path gas cell/FTIR (Fourier Transform Infrared) spectrometer system. The applicability of this system is demonstrated by qualitative analysis of a series of volatiles measured individually. In addition, the linear dependence of absorption intensity on headspace sample volumes was checked by measuring gas-phase IR absorption spectra of increasing volumes of pure CO 2 gas aliquots. Finally, the instrument performance was evaluated by measuring the relative concentration of NH 3 (g) in methanol solution.

Curation↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

Controlled Pyrolysis: A Robust Scalable Composite Recycling Technology

The reinforced composites industry is facing significant challenges in handling the scrap composite material from automobile manufacturing, the wind turbine industry, and others. The fibers in the material, whether they be carbon, glass, or other materials have commercial value if they can be recovered successfully. Successfully means the fibers are clean with no sizing or other binders and have adequate strength and physical properties that would allow them to be economically reprocessed into valuable product. The composites recycling project was an industry-collaborative effort to develop a composite recycling technology using controlled pyrolysis. Through the recycling of scrap and end-of-life (EOL) cured composite materials, this pilot study was intended to create a business case by realizing a cost-effective means for recycling EOL and production scrap composite materials, ultimately reducing the volume of composite materials destined for landfill. The project was led by the Institute for Advanced Composites Manufacturing Innovation (IACMI), the American Composites Manufacturers Association (ACMA), Oak Ridge National Laboratory (ORNL), Continental Structural Plastics (CSP) a Teijin Group Company, CHZ Technologies, and A. Schulman with support from Owens Corning, John Deere, General Electric (GE), Ashland LLC, and Plastics Europe (CEFIC). The team studied and tested CHZ Technologies’ controlled pyrolysis system, known as the Thermolyzer TM , which operates on a scalable basis to convert organic polymer materials into a clean synthesis gas and char containing the recoverable carbon and glass fiber reinforcement. The recoverable energy contained in the input polymers creates the synthesis gas that can be used to provide heat to the Thermolyzer TM primary reactor in a sustainable manner. That is, once the Thermolyzer TM is started with a small amount of external natural gas, the synthesis gas that is created from the polymers will continue to operate the burners so long as feedstock is supplied. The reinforcing fiber materials remaining in the solid phase char were separated and cleaned for re-use in other polymer systems based on the retained properties of the fibers. The study created reports (attached in the appendix) on the Mass and Energy Balances, syngas analytics, VOC assessment, yield analysis and other analytics necessary for a Techno-Economic Analysis (TEA) to quantify the economic impact of the recovery and sustainable re-use of the carbon and glass fibers. The process consisted of 4 steps: Selection of 4 samples of cured composite waste materials from project partners interested in materials recycling and recovering the reinforcing fibers for best case re-use. The materials included glass fiber (GF) polyester/vinyl ester automotive SMC from CSP, GF epoxy balsa/PVC foam wind blades from GE, carbon fiber (CF) epoxy wind blade laminated spar caps from GE, and GF/CF epoxy hybrid assembly from John Deere. Processing the waste composite samples into 1-2” shreds. Packaging the shredded composites into bulk sacks on international shipping pallets for shipment to KUG in Forst (Lausitz), Germany. Pyrolysis of the shredded composites under controlled conditions designed for each polymer system. Collecting samples of the gas and char for analysis. Shipping the char containing the CF/GF back to the US for the next steps of testing the fibers and developing protocols for sustainable re-use of the fibers in composite applications.

36 MATERIALS SCIENCE↗

A Study of the Curation Protocol by Sample Analysis Working Team (SAWT) in Martian Moons eXploration (MMX) Project

Japan Aerospace Exploration Agency (JAXA) will launch a spacecraft in 2024 for a sample return mission from Phobos (Martian Moons eXploration: MMX). The major scientific goals of MMX are to constrain (1) the origin of Phobos and Deimos and (2) the evolution of the Mars-moon system [1]. The touchdown operations are planned to be performed twice at different landing sites on the Phobos surface to collect > 10 g of the surface materials [2]. After the return to the Earth, the Phobos samples will be collected from the individual sample canisters and introduced to the clean chamber installed at ISAS (Institute of Space and Astronautical Science). The Sample Analysis Working Team (SAWT) of MMX designed the procedure of Phobos sample analysis mainly conducted by the initial analysis teams [3]. For the next step, the SAWT will define the procedure of the curation process (mostly non-destructive analysis) of the Phobos samples, which will be presented here. The protocols of the Phobos sample curation is illustrated in figure 1. First, the headspace gas from the sample container will be collected during the Quick Analysis phase. The Quick Analysis will be operated by the sampler and curation teams in ISAS/JAXA. The terrestrial leak and contamination from the sampling systems will be tested using a quadrupole mass spectrometer equipped with a gas sampling system. Second, the bulk Phobos sample will be observed in the clean chamber under purified-N2 gas with an ambient condition (Pre-basic Characterization). This phase will be operated by the curation team in ISAS/JAXA and the instrument team of the MMX mission. The consistency between the data from the instruments in the clean chamber and the spacecraft will then be evaluated. Subsequently, the curation will distribute the small amount of Phobos samples to the Initial analysis team of MMX to conduct the "Preliminary Examination". The objectives of the preliminary examination are to provide (1) feedback on the subsequent sample allocation process, (2) preliminary scientific results that will address parts of MMX mission goals, and (3) evaluation of the sampling system and terrestrial alteration on Phobos samples. Because multiple models are proposed for the origin of Phobos [1] (e.g., giant impact, the capture of asteroids), the chemical and mineralogical characteristics of Phobos must be assessed before the allocation of the samples to the individual initial analysis teams. Simultaneously, the curation team in JAXA will observe the individual grains and aliquots of the samples in the clean chamber (Basic Characterization).

R Fukai↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Analysis of Mars Analogue Soil Samples Using Solid-Phase Microextraction, Organic Solvent Extraction and Gas Chromatography/Mass Spectrometry

Polycyclic aromatic hydrocarbons (PAHs) are robust and abundant molecules in extraterrestrial environments. They are found ubiquitously in the interstellar medium and have been identified in extracts of meteorites collected on Earth. PAHs are important target molecules for planetary exploration missions that investigate the organic inventory of planets, moons and small bodies. This study is part of an interdisciplinary preparation phase to search for organic molecules and life on Mars. We have investigated PAH compounds in desert soils to determine their composition, distribution and stability. Soil samples (Mars analogue soils) were collected at desert areas of Utah in the vicinity of the Mars Desert Research Station (MDRS), in the Arequipa region in Peru and from the Jutland region of Denmark. The aim of this study was to optimize the solid-phase microextraction (SPME) method for fast screening and determination of PAHs in soil samples. This method minimizes sample handling and preserves the chemical integrity of the sample. Complementary liquid extraction was used to obtain information on five- and six-ring PAH compounds. The measured concentrations of PAHs are, in general, very low, ranging from 1 to 60 ng g(sup -1). The texture of soils is mostly sandy loam with few samples being 100% silt. Collected soils are moderately basic with pH values of 8-9 except for the Salten Skov soil, which is slightly acidic. Although the diverse and variable microbial populations of the samples at the sample sites might have affected the levels and variety of PAHs detected, SPME appears to be a rapid, viable field sampling technique with implications for use on planetary missions.

Orzechowska, G. E.↗

Research on miniature gas analysis systems

Technology for fabricating very small valves, whose function will be to introduce a small sample of the gas to be analyzed into the main carrier gas stream flowing through the chromatograph column is described. In addition, some analyses were made of the factors governing the resolution of gas chromatographs, particularly those with miniature columns. These analyses show how important the column lining thickness is in governing the ability of a miniature column to separate components of an unknown gas. A brief description of column lining factors is included. Preliminary work on a super small thermistor detector is included.

Angell, J. B.↗

Elemental mapping and geochemical characterization of gas producing shales by laser induced breakdown spectroscopy

Laser induced breakdown spectroscopy (LIBS) has been used for the analysis of hydrocarbon bearing shale samples. Shale samples taken from a Marcellus gas well at depths ranging from 7498 to 7551 ft (2285.4–2301.5 m) were analyzed by LIBS using an 81 × 81 grid pattern covering an 8 × 8 mm area. The data collected from these experiments were used to construct 2D elemental maps for each sample including the hydrocarbon forming elements C and H. Results show that the spatial elemental composition of the shale varies due to the matrix of the rock, and as a function of the sample depth. The accuracy of the analysis was confirmed by analyzing a shale sample of known elemental concentrations and obtaining a good agreement between analyzed and reference values. It has been shown that LIBS can be used to determine elemental composition variations in hydrocarbon bearing shales in a laboratory setting. In conclusion, extending this capability into wellbores will enable producers to rapidly target resources with greater accuracy.

04 OIL SHALES AND TAR SANDS↗

Batch Gas-Sampling System

Sampler collects air or other gases in consistent way and stabilizes them for later chemical analysis. Device used for concentrations ranging from few parts per million to 100 percent. Also separates and collects particles in gas for analysis. Gas flows into vacuum sphere when solenoid valve opened. As it passes through conversion tube, constituent of gas forms stable compound that remains in conversion tube for analysis at later time. Sampler parts made of glass, polytetrafluoroethylene, and stainless steel so they do not react with sample.

Diaz, Vernon, Jr.↗