Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gauge function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Design for Inspection: A Formalized Approach to Evaluating the Inspectability of Aerospace Structures Early in the Design Process

NDE engineers are often confronted with structural design choices that present challenges to meeting inspection requirements. These challenges at best increase the resources needed to design an inspection solution and, at worst, require resource intensive redesign of the structure. If the inspectability of structure can be determined early in the design cycle, these challenging inspection scenarios can be avoided. Therefore, there exists a need for a resource friendly formalized approach to gauge the inspectability of a structure. This paper proposes the use of a novel inspectability metric to meet this need. The inspectability metric is a standardized, automation friendly procedure that uses simulations to determine inspectability. It provides a suite of simulation tests to interrogate the ability to find defects and the sensitivity to variability. The testing rubric is designed to maximize the coverage of the parameter space while minimizing the number of simulations needed. In this preliminary study, we will demonstrate how the inspectability metric is able to determine the inspectability of a structure as a function of changes in the structure’s design.

Peter Juarez↗

A practical ultrasonic plethysmograph

An ultrasonic plethysmograph, which gives improved performance over the standard Whitney Strain Gauge, is described. This instrument monitors dimension changes in human limbs by measuring the transit times of acoustic pulses across two chords of the limb. In the case of a small uniform expansion, the percentage change in limb volume is shown to be proportional to twice the percentage change in either of the measured chords. Measurement of two chords allows correction for possible non-uniform expansion. In addition, measurement of two chords allows an estimate of the absolute cross-sectional area of the limb. The developed instrument incorporates a microprocessor, which performs necessary calculation and control functions. Use of the microprocessor allows the instrument to be self-calibrating. In addition, the device can be easily reprogrammed to incorporate improvements in operating features or computational schemes.

Wu, V. C.↗

SansEC: A New Dimension to Sensing Electrical Sensors with No Electrical Connections

This DVD contains an introduction to SansEC, a new electrical sensor technology without electrical connections. This new class of sensors represents a stand-alone 2-dimensional geometric pattern of electrically open circuits without electrical connections. The sensor is powered with an external, harmonic magnetic field and as the property being sensed changes, responds to frequency, amplitude or bandwidth changes. This response is interrogated using an external antenna, a single electrical component having no electrical connections. The sensor can be encased in any nonconductive material to provide protection from its environment. If the container is nonconductive, the sensor can be placed external to the container without contacting it, making installation very simple. An encased sensor can also be placed inside a container for measuring the level of any fluid or material, including acids. Any readout device can be used with the sensor, including standard or digital gauges. SansEC sensors can be used to measure real-time fluid slosh to determine if a fuel tank's internal structural isogrid can be used to replace some of the baffles surface, thus reducing the overall baffle weight and giving a better understanding of the effect that isogrids have on fluid motion. Any SansEC sensor can also be used for damage or tamper detection. When damaged, torn or tampered with, the measured response shift in frequency is commensurate to the detected damage, with the response frequency increasing with rising damage. The unique sensor design allows it to function even if damaged, because unlike other circuits, there is no single point on the sensor that, if damaged, renders it non-functional. The broad metallic coverage of the array allows the array to be one of many thermal insulation layers. Two such arrays were tested to understand the effects of high velocity damage. Each test article was targeted with metal projectiles emulating micrometeorite or orbital debris impact. Even with the damage that the sensors received every sensor was still functional with the new response baseline, and remained capable of detecting even more damage.

Source record↗

The Effects of Partial Mechanical Loading and Ibandronate on Skeletal Tissues in the Adult Rat Hindquarter Suspension Model for Microgravity

We report initial data from a suspended rat model that quantitatively relates chronic partial weightbearing to bone loss. Chronic partial weightbearing is our simulation of the effect of limited artificial gravity aboard spacecraft or reduced planetary gravity. Preliminary analysis of bone by PQCT, histomorphometry, mechanical testing and biochemistry suggest that chronic exposure to half of Earth gravity is insufficient to prevent severe bone loss. The effect of episodic full weightbearing activity (Earth Gravity) on rats otherwise at 50% weightbearing was also explored. This has similarity to treatment by an Earth G-rated centrifuge on a spacecraft that normally maintained artificial gravity at half of Earth G. Our preliminary evidence, using the above techniques to analyze bone, indicate that 2 hours daily of full weightbearing was insufficient to prevent the bone loss observed in 50% weightbearing animals. The effectiveness of partial weightbearing and episodic full weightbearing as potential countermeasures to bone loss in spaceflight was compared with treatment by ibandronate. Ibandronate, a long-acting potent bisphosphonate proved more effective in preventing bone loss and associated functionality based upon structure than our first efforts at mechanical countermeasures. The effectiveness of ibandronate was notable by each of the testing methods we used to study bone from gross structure and strength to tissue and biochemistry. These results appear to be independent of generalized systemic stress imposed by the suspension paradigm. Preliminary evidence does not suggest that blood levels of vitamin D were affected by our countermeasures. Despite the modest theraputic benefit of mechanical countermeasures of partial weightbearing and episodic full weightbearing, we know that some appropriate mechanical signal maintains bone mass in Earth gravity. Moreover, the only mechanism that correctly assigns bone mass and strength to oppose regionally specific force applied to bone is mechanical, a process based upon bone strain. Substantial evidence indicates that the specifics of dynamic loading i.e. time-varying forces are critical. Bone strain history is a predictor of the effect that mechanical conditions have on bone structure mass and strength. Using servo-controlled force plates on suspended rats with implanted strain gauges we manipulated impact forces of ambulation in the frequency (Fourier) domain. Our results indicate that high frequency components of impact forces are particularly potent in producing bone strain independent of the magnitude of the peak force or peak energy applied to the leg. Because a servo-system responds to forces produced by the rat's own muscle activity during ambulation, the direction of ground-reaction loads act on bone through the rat's own musculature. This is in distinction to passive vibration of the floor where forces reach bone through the natural filters of soft tissue and joints. Passive vibration may also be effective, but it may or may not increase bone in the appropriate architectural pattern to oppose the forces of normal ambulatory activity. Effectiveness of high frequency mechanical stimulation in producing regional (muscle directed) bone response will be limited by 1. the sensitivity of bone to a particular range of frequencies and 2. the inertia of the muscles, limiting their response to external forces by increasing tension along insertions. We have begun mathematical modeling of normal ambulatory activity. Effectiveness of high frequency mechanical stimulation in producing regional (muscle directed) bone response will be limited by 1. the sensitivity of bone to a particular range of frequencies and 2. the inertia of the muscles, limiting their response to external forces by increasing tension along insertions. We have begun mathematical modeling of the rat forelimb as a transfer function between impact force and bone strain to predict optimal dynamic loading conditions for this system. We plan additional studies of mechanical counter-measures that incorporate improved dynamic loading, features relevant to anticipated evaluation of artificial gravity, exercise regimens and exposure to Martian gravity, The combination of mechanical countermeasures with ibandronate will also be investigated for signs of synergy.

Schultheis, Lester W.↗

Airborne Differential Doppler Weather Radar

The Precipitation Radar aboard the Tropical Rain Measuring Mission (TRMM) Satellite has shown the potential for spaceborne sensing of snow and rain by means of an incoherent pulsed radar operating at 13.8 GHz. The primary advantage of radar relative to passive instruments arises from the fact that the radar can image the 3-dimensional structure of storms. As a consequence, the radar data can be used to determine the vertical rain structure, rain type (convective/stratiform) effective storm height, and location of the melting layer. The radar, moreover, can be used to detect snow and improve the estimation of rain rate over land. To move toward spaceborne weather radars that can be deployed routinely as part of an instrument set consisting of passive and active sensors will require the development of less expensive, lighter-weight radars that consume less power. At the same time, the addition of a second frequency and an upgrade to Doppler capability are features that are needed to retrieve information on the characteristics of the drop size distribution, vertical air motion and storm dynamics. One approach to the problem is to use a single broad-band transmitter-receiver and antenna where two narrow-band frequencies are spaced apart by 5% to 10% of the center frequency. Use of Ka-band frequencies (26.5 GHz - 40 GHz) affords two advantages: adequate spatial resolution can be attained with a relatively small antenna and the differential reflectivity and mean Doppler signals are directly related to the median mass diameter of the snow and raindrop size distributions. The differential mean Doppler signal has the additional property that this quantity depends only on that part of the radial speed of the hydrometeors that is drop-size dependent. In principle, the mean and differential mean Doppler from a near-nadir viewing radar can be used to retrieve vertical air motion as well as the total mean radial velocity. In the paper, we present theoretical calculations for the differential reflectivity and Doppler as functions of the center frequency, frequency difference, and median mass diameter. For a fixed pair of frequencies, the detectability of the differential signals can be expressed as the number of independent samples required to detect rain or snow with a particular median mass diameter. Because sampling numbers on the order of 1000 are needed to detect the differential signal over a range of size distributions, the instrument must be confined to a near-nadir, narrow swath. Radar measurements from a zenith directed radar operated at 9.1 GHz and 10 GHz are used to investigate the qualitative characteristics of the differential signals. Disdrometer and rain gauge data taken at the surface, just below the radar, are used to test whether the differential signals can be used to estimate characteristics of the raindrop size distribution.

Meneghini, R.↗

Development Towards a Space Qualified Laser Stabilization System in Support of Space-Based Optical Interferometers

We report on the development, functional performance and space-qualification status of a laser stabilization system supporting a space-based metrology source used to measure changes in optical path lengths in space-based stellar interferometers. The Space Interferometry Mission (SIM) and Deep Space 3 (DS-3) are two missions currently funded by the National Aeronautics and Space Administration (NASA) that are space-based optical interferometers. In order to properly recombine the starlight received at each telescope of the interferometer it is necessary to perform high resolution laser metrology to stabilize the interferometer. A potentially significant error source in performing high resolution metrology length measurements is the potential for fluctuations in the laser gauge itself. If the laser frequency or wavelength is changing over time it will be misinterpreted as a length change in one of the legs of the interferometer. An analysis of the frequency stability requirement for SIM resulted in a fractional frequency stability requirement of square root (S(sub y)(f)) = <2 x 10(exp -12)/square root(Hz) at Fourier frequencies between 10 Hz and 1000 Hz. The DS-3 mission stability requirement is further increased to square root (S(sub y)(f)) = <5 x 10(exp -14)/Square root(Hz) at Fourier frequencies between 0.2 Hz and 10 kHz with a goal of extending the low frequency range to 0.05 Hz. The free running performance of the Lightwave Electronics NPRO lasers, which are the baseline laser for both SIM and DS-3 vary in stability and we have measured them to perform as follows (9 x l0(exp -11)/ f(Hz))(Hz)/square root(Hz)) = <( square root (S(sub y)(f)) = <(1.3 x l0(exp -8)/ f(Hz))/Square root(Hz). In order to improve the frequency stability of the laser we stabilize the laser to a high finesse optical cavity by locking the optical frequency of the laser to one of the transmission modes of the cavity. At JPL we have built a prototype space-qualifiable system meeting the stability requirements of SIM, which has been delivered to one of the SIM testbeds. We have also started on the development of a system to meet the stability needs of DS-3.

Seidel, David J.↗

Evaluating Suit Fit Using Performance Degradation

The Mark III suit has multiple sizes of suit components (arm, leg, and gloves) as well as sizing inserts to tailor the fit of the suit to an individual. This study sought to determine a way to identify the point an ideal suit fit transforms into a bad fit and how to quantify this breakdown using mobility-based physical performance data. This study examined the changes in human physical performance via degradation of the elbow and wrist range of motion of the planetary suit prototype (Mark III) with respect to changes in sizing and as well as how to apply that knowledge to suit sizing options and improvements in suit fit. The methods implemented in this study focused on changes in elbow and wrist mobility due to incremental suit sizing modifications. This incremental sizing was within a range that included both optimum and poor fit. Suited range of motion data was collected using a motion analysis system for nine isolated and functional tasks encompassing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm only. The results were then compared across sizing configurations. The results of this study indicate that range of motion may be used as a viable parameter to quantify at what stage suit sizing causes a detriment in performance; however the human performance decrement appeared to be based on the interaction of multiple joints along a limb, not a single joint angle. The study was able to identify a preliminary method to quantify the impact of size on performance and to develop a means to gauge tolerances around optimal size. More work is needed to improve the assessment of optimal fit and to compensate for multiple joint interactions.

Margerum, Sarah E.↗

Evaluating Suit Fit Using Performance Degradation

The Mark III planetary technology demonstrator space suit can be tailored to an individual by swapping the modular components of the suit, such as the arms, legs, and gloves, as well as adding or removing sizing inserts in key areas. A method was sought to identify the transition from an ideal suit fit to a bad fit and how to quantify this breakdown using a metric of mobility-based human performance data. To this end, the degradation of the range of motion of the elbow and wrist of the suit as a function of suit sizing modifications was investigated to attempt to improve suit fit. The sizing range tested spanned optimal and poor fit and was adjusted incrementally in order to compare each joint angle across five different sizing configurations. Suited range of motion data were collected using a motion capture system for nine isolated and functional tasks utilizing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm by itself. Findings indicated that no single joint drives the performance of the arm as a function of suit size; instead it is based on the interaction of multiple joints along a limb. To determine a size adjustment range where an individual can operate the suit at an acceptable level, a performance detriment limit was set. This user-selected limit reveals the task-dependent tolerance of the suit fit around optimal size. For example, the isolated joint motion indicated that the suit can deviate from optimal by as little as -0.6 in to -2.6 in before experiencing a 10% performance drop in the wrist or elbow joint. The study identified a preliminary method to quantify the impact of size on performance and developed a new way to gauge tolerances around optimal size.

Margerum, Sarah E.↗

NASA Tech Briefs, April 2007

Topics include: Wearable Environmental and Physiological Sensing Unit; Broadband Phase Retrieval for Image-Based Wavefront Sensing; Filter Function for Wavefront Sensing Over a Field of View; Iterative-Transform Phase Retrieval Using Adaptive Diversity; Wavefront Sensing With Switched Lenses for Defocus Diversity; Smooth Phase Interpolated Keying; Maintaining Stability During a Conducted-Ripple EMC Test; Photodiode Preamplifier for Laser Ranging With Weak Signals; Advanced High-Definition Video Cameras; Circuit for Full Charging of Series Lithium-Ion Cells; Analog Nonvolatile Computer Memory Circuits; JavaGenes Molecular Evolution; World Wind 3D Earth Viewing; Lithium Dinitramide as an Additive in Lithium Power Cells; Accounting for Uncertainties in Strengths of SiC MEMS Parts; Ion-Conducting Organic/Inorganic Polymers; MoO3 Cathodes for High-Temperature Lithium Thin-Film Cells; Counterrotating-Shoulder Mechanism for Friction Stir Welding; Strain Gauges Indicate Differential-CTE-Induced Failures; Antibodies Against Three Forms of Urokinase; Understanding and Counteracting Fatigue in Flight Crews; Active Correction of Aberrations of Low-Quality Telescope Optics; Dual-Beam Atom Laser Driven by Spinor Dynamics; Rugged, Tunable Extended-Cavity Diode Laser; Balloon for Long-Duration, High-Altitude Flight at Venus; and Wide-Temperature-Range Integrated Operational Amplifier.

Source record↗

How Well do Multisatellite Products Capture the Space-Time Dynamics of Precipitation? Part II: Building an Error Model Through Spectral System Identification

Satellite precipitation products, as all quantitative estimates, come with some inherent degree of uncertainty. To associate a quantitative value of the uncertainty to each individual estimate, error modeling is necessary. Most of the error models proposed so far compute the uncertainty as a function of precipitation intensity only, and only at one specific spatio-temporal scale. We propose a spectral error model which accounts for the neighboring space-time dynamics of precipitation into the uncertainty quantification. Systematic distortions of the precipitation signal and random errors are characterized distinctively in every frequency-wavenumber band in the Fourier domain, to accurately characterize error across scales. The systematic distortions are represented as a deterministic space-time linear filtering term. The random errors are represented as a non-stationary additive noise. The spectral error model is applied to the IMERG multi satellite precipitation product and its parameters are estimated empirically through a system identification approach using the GV-MRMS gauge-radar measurements as reference (“truth”) over the eastern United States. The filtering term is found to be essentially low-pass. While traditional error models attribute most of the error variance to random errors, it is found here that the systematic filtering term explains 48% of the error variance at the native resolution of IMERG. This fact confirms that, at high resolution, filtering effects in satellite precipitation products cannot be ignored, and that the error cannot be represented as a purely random additive or multiplicative term. An important consequence is that precipitation estimates derived from totally different sources shall not be expected to automatically have statistically independent errors.

Precipitation↗

Numerical study of the effects of boundary conditions on the measurement and calibration of gardon type heat flux sensors

To monitor the high-intensity heat flux conditions that occur in the space shuttle main engine (SSME), it is necessary to use specifically designed heat flux sensors. These sensors, which are of the Gardon-type, are exposed on the measuring face to high-intensity radiative and convective heat fluxes and on the other face to convective cooling. To improve the calibration and measurement accuracy of these gauges, researchers are studing the effect that the thermal boundary conditions have on gauge performance. In particular, they are studying how convective cooling effects the field inside the sensor and the measured heat flux. The first phase of this study involves a numerical study of these effects. Subsequent phases will involve experimental verification. A computer model of the heat transfer around a Garden-type heat flux sensor was developed. Two specific geometries are being considered are: (1) heat flux sensor mounted on a flat-plate; and (2) heat flux sensor mounted at the stagnation point of a circular cylinder. Both of these configurations are representative of the use of heat flux sensors in the components of the SSME. The purpose of the analysis is to obtain a temperature distribution as a function of the boundary conditions.

Krane, M.↗

Black holes in magnetic monopoles

We study magnetically charged classical solutions of a spontaneously broken gauge theory interacting with gravity. We show that nonsingular monopole solutions exist only if the Higgs field vacuum expectation value v is less than or equal to a critical value v sub cr, which is of the order of the Planck mass. In the limiting case, the monopole becomes a black hole, with the region outside the horizon described by the critical Reissner-Nordstrom solution. For v less than v sub cr, we find additional solutions which are singular at f = 0, but which have this singularity hidden within a horizon. These have nontrivial matter fields outside the horizon, and may be interpreted as small black holes lying within a magnetic monopole. The nature of these solutions as a function of v and of the total mass M and their relation to the Reissner-Nordstrom solutions is discussed.

Lee, Kimyeong↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗

Multimodality stereotactic brain tissue identification: the NASA smart probe project

Real-time tissue identification can benefit procedures such as stereotactic brain biopsy, functional neurosurgery and brain tumor excision. Optical scattering spectroscopy has been shown to be effective at discriminating cancer from noncancerous conditions in the colon, bladder and breast. The NASA Smart Probe extends the concept of 'optical biopsy' by using neural network techniques to combine the output from 3 microsensors contained within a cannula 2. 7 mm in diameter (i.e. the diameter of a stereotactic brain biopsy needle). Experimental data from 5 rats show the clear differentiation between tissues such as brain, nerve, fat, artery and muscle that can be achieved with optical scattering spectroscopy alone. These data and previous findings with other modalities such as (1) analysis of the image from a fiberoptic neuroendoscope and (2) the output from a microstrain gauge suggest the Smart Probe multiple microsensor technique shows promise for real-time tissue identification in neurosurgical procedures. Copyright 2000 S. Karger AG, Basel.

Non-programmatic↗

Photoionization in Ultraviolet Processing of Astrophysical Ice Analogs at Cryogenic Temperatures

Two recent experimental studies have demonstrated that amino acids or amino acid precursors are generated when astrophysical ice analogs are subjected to ultraviolet (UV) irradiation at cryogenic temperatures. Understanding the complete phenomenology of photoprocessing is critical to elucidating chemical reaction mechanisms that can function within an ice matrix under very cold conditions. Pushing beyond the much better characterized study of photolytic dissociation of chemical bonds through electronic excitation, this work explored the ability of UV radiation present in the interstellar medium to ionize small molecules embedded in ices. Quantum chemical calculations, including bulk solvation effects, were used to study the ionization of hydrogen (H2), water, and methanol (CH3OH) bound in small clusters of water. Ionization potentials were found to be much smaller in the condensed phase than in the gas phase; even a small cluster can account for large changes in the ionization potentials in ice, as well as the known formation of an OH--H3O+ pair in the case of H2O photoionization. To gauge the impact of photoionization on subsequent grain chemistry, the reaction between OH and CO in the presence of H3O+ was studied and compared with the potential energy surface without hydronium present, which is relevant to chemistry following photolysis. The differences indicate that the reaction is somewhat more likely to proceed to products (H + CO2) in the case of photoionization.

Woon, David E.↗

The Next-Generation Version 3 GPCP Products

The long-standing Global Precipitation Climatology Project (GPCP) recently introduced its next-generation Version 3.1 Monthly product, , which covers the period 1983-2019. Notable improvements include higher spatial resolution (0.5°x0.5°), geosynchronous IR estimates extended to the latitude band 60°N-S and based on the Precipitation Estimation from Remotely Sensed Information using Artificial Neural Networks-Climate Data Record (PERSIANN-CDR) algorithm, and high-latitude (outside 60ºN-S) precipitation estimates based on improved calibrations of Television-Infrared Operational Satellite (TIROS) Operational Vertical Sounder (TOVS) and Advanced Infrared Sounder (AIRS) data. The satellite-only estimate is adjusted to the best available monthly climatologies, namely the Tropical Combined Climatology (TCC) at lower latitudes and the Merged CloudSat, TRMM, and GPM (MCTG) climatology at higher latitudes. Finally, V3.1 merges these climatologically-adjusted satellite-only estimates with the Global Precipitation Climatology Centre (GPCC) gauge analyses at 1°x1°. In addition to the V3.1 Monthly product, the GPCP team is working towards a global Version 3 Daily product based on Integrated Multi-satellitE Retrievals for Global Precipitation Measurement (GPM) mission (IMERG) Final Run V06 estimates, where available, calibrated to the GPCP V3.1 Monthly estimate. Rescaled TOVS/AIRS data are used in high-latitude areas that lack IMERG estimates, which occur over snowy/icy surfaces outside 60°N-S. Since IMERG currently extends back to June 2000, daily PERSIANN-CDR data are used for the period January 1983–May 2000 to complete the record. This presentation will provide early results for, and the latest status of, the Monthly and Daily GPCP products as a function of time and region. Key points include examining homogeneity over time and across boundaries between input datasets. One goal is to determine the suitability of the V3 products while we continue to produce the Version 2 GPCP products for on-going use.

precipitation↗

Direct Ink Write 3D Printing of Fully Dense and Functionally Graded Liquid Metal Elastomer Foams

Liquid metal (LM) elastomer composites offer promising potential in soft robotics, wearable electronics, and human-machine interfaces. Direct ink write (DIW) 3D printing offers a versatile manufacturing technique capable of precise control over LM microstructures, yet challenges such as interfilament void formation in multilayer structures impact material performance. Here, a DIW strategy is introduced to control both LM microstructure and material architecture. Investigating three key process parameters–nozzle height, extrusion rate, and nondimensionalized nozzle velocity–it is found that nozzle height and velocity predominantly influence filament geometry. The nozzle height primarily dictates the aspect ratio of the filament and the formation of voids. A threshold print height based on filament geometry is identified; below the height, significant surface roughness occurs, and above the ink fractures, which facilitates the creation of porous structures with tunable stiffness and programmable LM microstructure. These porous architectures exhibit reduced density and enhanced thermal conductivity compared to cast samples. When used as a dielectric in a soft capacitive sensor, they display high sensitivity (gauge factor = 9.0), as permittivity increases with compressive strain. These results demonstrate the capability to simultaneously manipulate LM microstructure and geometric architecture in LM elastomer composites through precise control of print parameters, while maintaining geometric fidelity in the printed design.

Spencer Pak↗

Passive microwave remote sensing of rainfall with SSM/I: Algorithm development and implementation

A physically based algorithm sensitive to emission and scattering is used to estimate rainfall using the Special Sensor Microwave/Imager (SSM/I). The algorithm is derived from radiative transfer calculations through an atmospheric cloud model specifying vertical distributions of ice and liquid hydrometeors as a function of rain rate. The algorithm is structured in two parts: SSM/I brightness temperatures are screened to detect rainfall and are then used in rain-rate calculation. The screening process distinguishes between nonraining background conditions and emission and scattering associated with hydrometeors. Thermometric temperature and polarization thresholds determined from the radiative transfer calculations are used to detect rain, whereas the rain-rate calculation is based on a linear function fit to a linear combination of channels. Separate calculations for ocean and land account for different background conditions. The rain-rate calculation is constructed to respond to both emission and scattering, reduce extraneous atmospheric and surface effects, and to correct for beam filling. The resulting SSM/I rain-rate estimates are compared to three precipitation radars as well as to a dynamically simulated rainfall event. Global estimates from the SSM/I algorithm are also compared to continental and shipboard measurements over a 4-month period. The algorithm is found to accurately describe both localized instantaneous rainfall events and global monthly patterns over both land and ovean. Over land the 4-month mean difference between SSM/I and the Global Precipitation Climatology Center continental rain gauge database is less than 10%. Over the ocean, the mean difference between SSM/I and the Legates and Willmott global shipboard rain gauge climatology is less than 20%.

Ferriday, James G.↗