Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphite specimens”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Results of an exploration of the relationship between ultrasonic attenuation and fatigue survivability of graphite fiber epoxy composites fabricated under different cure conditions are reported. A total of 9 27 x 40 cm eight-ply graphite epoxy laminated specimens were formed, and fatigue tests were run on five partial samples at 73.5 N varying at 30 Hz, with tests ending at a 1.27 cm deflection. A pulsed oscillator generated sinusoidal waves and transducers recorded the passage of the ultrasonic waves for display on oscilloscopes. Cure pressures ranged from 0.52-0.85 MPa and cure temperatures were in the 150-200 C interval. Ultrasonic through-transmission at 4 MHz was performed prior to and during fatigue testing. The minimum void volume fraction occurred at 175 C and 0.86 MPa. The flexural stiffness decreased with the number of fatigue cycles past 10,000, when the attenuation also increased. Correlations were found between the 4.0 MHz signal attenuation and the void volume fraction, and between the number of fatigue cycles to failure and the 4.0 MHz signal attenuation.

Williams, J. H., Jr.↗

On the off-axis tension test for unidirectional composites

The off axis tensile test was examined experimentally to obtain actual displacement fields over the surface of graphite polyimide coupon specimens. The experimental results were compared with approximate analytical solutions and generated finite element results. An optical method of high sensitivity moireinterferometry was used to determine the actual displacements to high precision. The approximate analytical solution and the finite element results compare very favorably with the measured centerline displacements in the test section, and the finite element displacement fields provide excellent agreement with the moiredisplacements throughout the specimen. A 15 degree fiber orientation and coupon aspect ratios of 5 and 15 are presented. Previously announced in STAR as N82-23553

Herakovich, C. T.↗

Embedded gage impact study

Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.

Schramm, S. W.↗

Electron emission and acoustic emission from the fracture of graphite/epoxy composites

In past studies it has been shown that the fracture of materials leads to the emission of a variety of species, including electrons, ions, neutral molecules, and photons, all encompassed by the term 'fractoemission' (FE). In this paper, electron emission (EE) from the fracture of single graphite fibers and neat epoxy resin is examined. Measurements of EE are also combined with the detection of acoustic emission (AE) during the testing of graphite-epoxy composite specimens with various fiber orientation. The characteristics of these signals are related to known failure mechanisms in fiber-reinforced plastics. This study suggests that by comparing data from AE and FE measurements, one can detect and distinguish the onset of internal and external failure in composites. EE measurements are also shown to be sensitive to the locus of fracture in a composite material.

Dickinson, J. T.↗

The 737 graphite composite flight spoiler flight service evaluation

The flight service experience of 111 graphite-epoxy spoilers on 737 transport aircraft and related ground based environmental exposure of graphite-epoxy material specimens is covered. Spoilers have been installed on 28 aircraft representing seven major airlines operating throughout the world. An extended flight service evaluation program of 15 years is presently underway. As of December 1984, a total of 2,092, 155 spoiler flight hours and 2,954,814 spoiler landings had been accumulated by this fleet.

Coggeshall, R. L.↗

Experimental measurement of material damping for space structures

A procedure for the measurement of material damping is described. The free decay of free-free beams, when lofted into free fall in vacuum, was recorded. Tests were performed on aluminum, graphite/epoxy, and graphite/magnesium metal matrix materials. Specimens with a fundamental free-free frequency below the elaxation frequency showed a higher level of damping and of stress dependence than predicted. For 0 sub 8 laminates, a material damping ratio of 0.00055 was found for fequencies varying from 45 Hz to 237 Hz. The damping was neither stress nor frequency dependent. For 90 sub 8 laminates, the damping ratio ranged from 0.0055 to 0.0066 as frequency ranged from 42 Hz to 143 Hz. Damping ratios for 90 sub 8 specimens were independent of stress. Experimentally measured damping ratios for metal matrix specimens with unidirectional graphite fibers, magnesium matrix, and either titanium or magnesium foil, ranged from .00039 to .00099, depending upon the matrix material, frequency, and possibly the stress range involved.

Crawley, E. F.↗

The 737 graphite composite flight spoiler flight service evaluation

The ninth flight service report was prepared in compliance with the requirements of Contract NAS1-11668. It covers the flight service experience of 111 graphite-epoxy spoilers on 737 transport aircraft and related ground-based environmental exposure of graphite epoxy material specimens for the period 1 Jan. 1985 through 31 Dec. 1986. Spoilers have been installed on 28 aircraft representing seven major airlines operating throughout the world. An extended flight service evaluation program of 15 years is presently underway. As of 31 Dec. 1986, a total of 3,339,608 spoiler flight-hours and 3,320,952 spoiler landings had been accumulated by this fleet.

Coggeshall, Randy L.↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Composite fracture using the normal stress ratio theory

Experiments were performed on center-notched specimens of unidirectional AS4/3501-6 graphite-epoxy subjected to varied far-field loading conditions. Specimens tested include on-axis and off-axis tensile coupons and Iosipescu shear specimens, allowing the study of normal, shear, and combined far-field loading conditions. From the tests, the direction of initial crack extension and the far-field stresses at crack initiation and fracture are obtained. The normal stress ratio theory is subsequently applied within a macroscopic-level homogeneous anisotropic stress solution to predict the direction of crack extension, critical stresses, and other crack growth behavior for the experiments. Comparison between experimental results and theoretical predictions indicates that application of the normal stress ratio theory within a macroscopic-level stress analysis has significant potential as an approach to modeling composite crack growth.

Beuth, J. L., Jr.↗

Validation of the IMCE RFDA System for Dynamic Elastic Moduli Measurements

The focus of this report is to describe the new system that has been acquired for the Low Activation Material Development and Analysis Laboratory (LAMDA) to perform the measurement of the dynamic Young’s and shear moduli, and to show that the results of the new system are more easily analyzed and more accurate than the current systems. The current system is the GrindoSonic MK5 Impulse Excitation and Vibration Test System from J.W. Lemmens, Inc., and the new system is the Resonant Frequency and Damping Analyser (RFDA) from Integrated Material Control Engineering (IMCE). A comparison between the results from both systems was performed with nine specimen shapes and five graphite grades. All of the results showed agreement of the moduli values within 1-2%. The only outliers were a 20% disagreement for one specimen shape and a 5-10% disagreement for a second specimen shape, but it was shown that this occurred because the GrindoSonic system was reporting the frequency for the flexural harmonic peak rather than the fundamental torsional peak.

36 MATERIALS SCIENCE↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗

Millimeter-Wave Thermal Analysis Development and Application to GEN IV Reactor Materials

New millimeter-wave thermal analysis instrumentation has been developed and studied for characterization of materials required for diverse fuel and structural needs in high temperature reactor environments such as the Next Generation Nuclear Plant (NGNP). A two-receiver 137 GHz system with orthogonal polarizations for anisotropic resolution of material properties has been implemented at MIT. The system was tested with graphite and silicon carbide specimens at temperatures up to 1300 ºC inside an electric furnace. The analytic and hardware basis for active millimeter-wave radiometry of reactor materials at high temperature has been established. Real-time, non contact measurement sensitivity to anisotropic surface emissivity and submillimeter surface displacement was demonstrated. The 137 GHz emissivity of reactor grade graphite (NBG17) from SGL Group was found to be low, ~ 5 %, in the 500 – 1200 °C range and increases by a factor of 2 to 4 with small linear grooves simulating fracturing. The low graphite emissivity would make millimeter-wave active radiometry a sensitive diagnostic of graphite changes due to environmentally induced stress fracturing, swelling, or corrosion. The silicon carbide tested from Ortek, Inc. was found to have a much higher emissivity at 137 GHz of ~90% Thin coatings of silicon carbide on reactor grade graphite supplied by SGL Group were found to be mostly transparent to millimeter-waves, increasing the 137 GHz emissivity of the coated reactor grade graphite to about ~14% at 1250 ºC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGC-1 Specimen Post Irradiation Data Report

Here we report the results of the Post Irradiation Examination (PIE) of the creep, control, and piggyback specimens from the irradiation creep capsule AGC-1. This is the first (prototype) of a series of six capsules planned as part of the Advanced Graphite Creep (AGC) experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphites. The data reported include: specimen dimensions and hence the dimensional change upon irradiation (a comparison of these data for specimen matched pairs will yield the creep strain); mass and volume, hence density; elastic constants (Young’s modulus, shear modulus and Poisson’s ratio) from ultrasonic time of flight (TOF) and velocity measurements; Young’s modulus from the fundamental frequency of vibration; electrical resistivity; and thermal expansion from 100-550°C (hence coefficient of thermal expansion). Over 8500 individual physical measurement have been made and the data are reduced and reported here. The AGC-1 capsule was irradiated in the Advanced Test Reactor (ATR) at INL at approximately 700°C and to a peak dose of 7 dpa (displacements per atom). The specimen’s final dose, temperature and stress conditions have been reported by INL and are also tabulated here. Additionally the analysis of the SiC temperature monitors is reported. These temperature monitors were located along the center of the AGC-1 capsule and provide an independent assessment of the capsules final irradiation temperature. While all the PIE testing is reported (with the exception of the glued-end tensile strength specimens) additional analysis of the AGC data will be required to allow: 1. Improved fits to the existing models of graphite irradiation induced creep strain. 2. With the eventual advent of temperature dependency data from the additional AGC series of capsules, and microstructural data from piggy back specimens in AGC capsules, the development of new and improved models for the development of irradiation induced creep strain in graphite are anticipated. 3. An Investigation into the effects of creep strain on the physical properties of irradiated graphite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A New Test Method for Determining the Strength and Fracture Toughness of Cement Mortar and Concrete

The Spiral Notch Torsion Fracture Toughness Test (SNTT) was developed recently to determine the intrinsic fracture toughness (KIC) of structural materials. The SNTT system operates by applying pure torsion to uniform cylindrical specimens with a notch line that spirals around the specimen at a 45 a pitch. KIC values are obtained with the aid of a three-dimensional finite-element computer code, TOR3D-KIC. The SNTT method is uniquely suitable for testing a wide variety of materials used extensively in pressure vessel and piping structural components and weldments. Application of the method to metallic, ceramic, and graphite materials has been demonstrated. One important characteristic of SNTT is that neither a fatigue precrack or a deep notch are required for the evaluation of brittle materials, which significantly reduces the sample size requirement. In this paper we report results for a Portland cement-based mortar to demonstrate applicability of the SNTT method to cementitious materials. The estimated KIC of the tested mortar samples with compressive strength of 34.45 MPa was found to be 0.19 MPa m^(1/2).

36 MATERIALS SCIENCE↗

Dynamic Deformation in Nuclear Graphite and Underlying Mechanisms

Time-dependent deformation in nuclear graphite is influenced by the creation and migration of radiation-induced defects in the reactor environment. This study investigates the role of pre-existing defects such as point defect clusters and Mrozowski cracks in nuclear graphite IG-110. Separate specimens were irradiated with a 2.8 MeV Au 2+ beam with a fluence of 4.38 × 10 14 cm −2 and an 8 MeV C 2+ beam with a fluence of 1.24 × 10 16 cm −2 . Microscopic specimens were either mechanically loaded inside a transmission electron microscope (TEM) or subjected to ex situ indentation-based creep loading. In situ TEM tests showed significant plasticity in regions highly localized around the Mrozowski cracks, resembling slip or ripplocation bands. Slip bands were also seen near regions without pre-existing defects but at very high stresses. Ex situ self-ion irradiation embrittled the specimens and decreased the creep displacement and rate, while heavy ion irradiation resulted in the opposite behavior. We hypothesize that the large-sized gold ions (compared to the carbon atoms) induced interplanar swelling as well as cross-plane channels for increased defect mobility. These findings illustrate the role of pre-existing defects in the dynamic relaxation of stresses during irradiation and the need for more studies into the radiation environment’s impact on the mechanical response of nuclear graphite.

creep deformation↗

Finite element analysis of the end notched flexure specimen for measuring Mode II fracture toughness

The paper presents a finite element analysis of the end-notched flexure (ENF) test specimen for Mode II interlaminar fracture testing of composite materials. Virtual crack closure and compliance techniques employed to calculate strain energy release rates from linear elastic two-dimensional analysis indicate that the ENF specimen is a pure Mode II fracture test within the constraints of small deflection theory. Furthermore, the ENF fracture specimen is shown to be relatively insensitive to process-induced cracks, offset from the laminate midplane. Frictional effects are investigated by including the contact problem in the finite element model. A parametric study investigating the influence of delamination length, span, thickness, and material properties assessed the accuracy of beam theory expressions for compliance and strain energy release rate, GII. Finite element results indicate that data reduction schemes based upon beam theory underestimate GII by approximately 20-40 percent for typical unidirectional graphite fiber composite test specimen geometries. Consequently, an improved data reduction scheme is proposed.

Gillespie, J. W., Jr.↗

Computational Reduction of Specimen Noise to Enable Improved Thermography Characterization of Flaws in Graphite Polymer Composites

Flaw detection and characterization with thermographic techniques in graphite polymer composites are often limited by localized variations in the thermographic response. Variations in properties such as acceptable porosity, fiber volume content and surface polymer thickness result in variations in the thermal response that in general cause significant variations in the initial thermal response. These result in a "noise" floor that increases the difficulty of detecting and characterizing deeper flaws. A method is presented for computationally removing a significant amount of the "noise" from near surface porosity by diffusing the early time response, then subtracting it from subsequent responses. Simulations of the thermal response of a composite are utilized in defining the limitations of the technique. This method for reducing the data is shown to give considerable improvement characterizing both the size and depth of damage. Examples are shown for data acquired on specimens with fabricated delaminations and impact damage.

Winfree, William P.↗