Search NASA⌕ Search

SEARCH · Search NASA

Results for “HALL ACCELERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Structure of the Neutron with Quasi-Elastic Scattering from 3H and 3HE

The magnetic form factor characterizes the magnetic distribution inside the neutron and knowledge of it is essential for the understanding of the neutron structure. The E12-11-112 experiment aimed to measure the neutron magnetic form factor (GnM) from the 3H/3He cross sections ratio, in the Q2 range of 0.5 - 3 GeV2. Quasi-elastic (QE) electron scattering was used to probe nucleons on the nucleus of the mirror 3H and 3He nuclei, in Hall A at the Thomas Jefferson National Accelerator Facility (JLab). The use of the mirror nuclei ratio is a novel extraction that cancels several systematic uncertainties from the cross section effects in the ratio. The motivation of this measurement is the disagreement between the precision measurements among the Q2 range of 0.5 - 1 GeV2 in the worldwide data. A total of five Q2 points were taken between this region and four more were taken with a Q2>1 GeV2 in order to estimate the accuracy of the method. Ideally, the 3H/3He ratio should be enough to calculate the magnetic form factor, but due to nuclear effects, there will be a correction of up to 8 % depending on the Q2 value that has to be evaluated before the form factor extraction. The cross sections were measured with a point-to-point uncertainty of 3 - 4.5 %, and the ratios were also evaluated with an uncertainty of 1.5 - 3 %. Therefore, the preliminary studies of the Gn M are summarized, and from the present analysis, it can be concluded that the precision of the measurement in the region of interest will be of the order of 1.5%.

Santiesteban, Sandra↗

MEASUREMENT OF THE GENERALIZED POLARIZABILITIES OF THE PROTON IN VIRTUAL COMPTON SCATTERING

Understanding how the visible matter in the universe arises from its elementary quark and gluon constituents is a central question for science. The visible world is founded on the proton, the only composite building block of matter that is stable in nature. Consequently, understanding the formation of matter relies on explaining the dynamics and the properties of the proton?s bound state. A fundamental property of the proton involves the system?s response to an external electromagnetic (EM) field. It is characterized by the EM polarizabilities that describe how easily the charge and magnetization distributions inside the system are distorted by the EM field. When the polarizabilities are generalized to finite momentum transfer, their Fourier transform can map out the spatial distribution of the polarization densities in a proton subject to an EM field. This thesis focuses on the measurement of the proton generalized polarizabilities (GPs) at low four-momentum transfer in experimental Hall C at the Thomas Jefferson National Accelerator Facility (TJNAF). Among the six independent GPs, we will focus on the electric (aE1) and the magnetic (bM1) scalar GPs. The GPs can be accessed through measurements of the Virtual Compton Scattering reaction, by replacing the incoming real photon of the Compton scattering process with a space-like virtual photon. The outgoing real photon provides the EM perturbation to the system. In addition, the Dispersion Relation Formalism is used for generalized polarizability extraction. In this work, the two scalar GPs measured with unprecedented precision, and the measurements help explore a momentum transfer region where an anomalous enhancement of the electric GP that contradicts the predictions of nuclear theory has been observed.

Li, Ruonan↗

Precise measurement of the nuclear dependence of the EMC effect in light nuclei

Measurements of inclusive electron scattering cross-section ratios from light nuclei over a wide range of the Björken G (0.3 ? G ? 1) up to &2 = 8.3 GeV2 were made as part of experiment E10-10-008, which was conducted in Hall C at the Thomas Jefferson National Accelerator Facility. The measurements were performed using a beam energy of 10.602 GeV and an average beam current of 45 `A. This dissertation provides a thorough description of the experiment as well as the extracted ratios of inclusive nuclear cross-sections with respect to the deuterium cross-sections (the EMC effect) for the targets 9Be, 12C, 10B, and 11B. The nuclear dependence of the inclusive inelastic electron scattering cross-section has been measured for the first time in 10B and 11B.

Karki, Abishek↗

A Measurement of the Eta Meson Radiative Decay Width via the Primakoff Effect

The ? meson is an interesting tool to study fundamental symmetries in Quantum Chromodynamics (QCD). In particular, its radiative decay width, ? p? Ñ ??q, is an important quantity that can be predicted in the framework of Chiral Perturbation Theory. A precision measurement of this quantity would provide critical inputs to understanding the mixing of the ? and ?1 mesons and extracting constants with wide-ranging applications in low-energy QCD. This decay width has been measured in the past using two different experimental techniques. The more popular technique utilized e`e´ collisions to produce ? mesons through electromagnetic interactions. Today, the Particle Data Group (PDG) averages the results of five such experiments to obtain their currently-accepted value of the decay width as: 0.515?0.018 keV. However the first measurement of this quantity was obtained from a fixed-target experiment that measured the cross section for photoproduction of ? mesons on a nuclear target via the Primakoff effect. Their result of 0.324?0.046 keV shows strong tension with the average of the collider measurements, motivating a new, high precision measurement using the Primakoff method. For this purpose, the PrimEx-eta experiment was conducted in Hall D of the Thomas Jefferson National Accelerator Facility (Jefferson Lab or JLab). The data is currently being analyzed to measure the differential cross section for the photoproduction of ? mesons on a liquid, 4He target. Preliminary results obtained from the analysis of the first phase of the PrimEx-eta experiment show reasonable agreement with the currently-accepted PDG value of the radiative decay width. However, as will be discussed, there are many challenges to this precision measurement which must be studied before any results can be finalized and compared with previous measurements. In parallel to the ? decay width measurement, the PrimEx-eta experiment measured the total cross section for the fundamental, Quantum Electrodynamics (QED) process of Compton scattering from the atomic electrons inside the target. The results obtained from this measurement are in strong agreement with the next-to-leading order QED calculations, and the total combined uncertainties are below 3% for incident photon energies between 7-10 GeV. In addition to providing the first precision measurement of the total Compton scattering cross section within this beam energy range, this measurement verifies the capability of the PrimEx-eta experimental setup to perform absolute cross section measurements at forward angles, and serves as a reference process for the calibration of systematic uncertainties.

Smith, Andrew↗

Measurement of the Pion Exclusive Electro-Production Cross-Section in the E12-19-006 Experiment in Hall-C at Jefferson Lab

One of the most effective methods for exploring the transition from hadronic degrees of freedom to quark-gluon degrees of freedom in Quantum Chromodynamics (QCD) is through the investigation of \exclusive" pion and kaon electro-production reactions at various Q2 and ?t values. The E12-19-006 experiment is conducted within the confi?nes of experimental Hall C at the Thomas Jefferson National Accelerator Facility, USA, for such studies. The primary aim of the experiment is to ?first enhance our comprehension of the pion electro-production cross-section and its form factor at Q2 = 0.38 and 0.42 GeV2. This is the fi?rst run period of the E12-19-006 experiment which ran in summer 2019. A more profound understanding of the pion electro-production reaction, 1H(e,e'?+)n, at low Q2 is deemed essential to employ this electro-production reaction (an indirect technique) for the high Q2 studies, thereby delving deeper into the realm of QCD. Consequently, this dissertation presents a thorough analysis of the experimental data acquired in the ?first run period of the E12-19-006 experiment. In pursuit of precision, a series of systematic studies (target boiling correction study, the elastic reaction cross-section measurements, study for determining vari- ous kinematics o?sets, etc.) are conducted to discern the accuracy of the analyzed data, a prerequisite for the use of Rosenbluth separation technique to separate the pion electro-production cross-section terms in t bins. The separated pion electro-production cross-section through the Rosenbluth separation technique is then used to extract the pion electromagnetic form factor. In this dissertation, the pion electro-production cross-section is carefully dissected into its four constituent components: longitudinal (?L), transverse (?T ), longitudinal-transverse (?LT ), and transverse-transverse (?TT ), using the full version of Rosenbluth separation technique for the Q2 = 0.38 GeV2. The technique is simultaneously fi?tted to the unseparated pion electro-production cross-sections at the three values of polarization of the virtual photon (?), i.e., ? = 0.286, 0.629 and 0.781. An iterative process is applied to re?ne the parameters of the model cross-sections until the yield ratio of experimental and Monte Carlo simulation converges. In this study, 21 iterations are conducted to re?ne the model cross-section parameters. The fi?nal pion electro-production cross-section terms are then determined for 7 t bins using the optimized parameters of the model cross-sections.

Kumar, Vijay↗

The Experimental Programs on Light Pseudoscalar Meson Decays

The decays of the low-lying pseudoscalar mesons (?0, ?, and ??) allow access to a plethora of physics probes, from measurements of fundamental properties of matter such as the up-down quark mass ratio, to studies of channels that access higher-order terms in Chiral Perturbation theory, to tests of fundamental symmetries and searches for signatures of physics beyond the Standard Model. Several experiments have studied pseudoscalar decays: these experiments include PrimEx in Hall B at Jefferson Lab, A2 at the MAMI electron accelerator facility, the KLOE-II experiment at the DA?NE ?-factory, WASA-at-COSY at the cooler synchrotron COSY storage ring, and BESIII at the Beijing charm factory. In Hall D at Jefferson Lab, PrimEx-eta uses the Primakoff process to measure the ? radiative width using the GlueX spectrometer. In the near future the Jefferson Lab Eta Factory (JEF) experiment will use the GlueX spectrometer with an upgraded forward calorimeter to study ?(?) decay channels with a focus on all-neutral final states. Finally, a proposal for a new experiment, ``Rare Eta Decays with a TPC for Optical Photons'' (REDTOP) utilizing a proton beam on fixed targets, is under development. Highlights from previous and ongoing experiments and plans for future experiments will be presented.

Taylor, Simon↗

Wiggler-based electron beam microbunching amplifier study

The wiggler-based amplifier of the microbunching instability in the electron beam is considered and compared to a longitudinal space charge amplifier consisting of the drifts and chicanes. The gain in the magnitude of a seed perturbation of the electron beam density is evaluated analytically as a function of the period of the perturbation, the electron beam parameters, the wiggler parameters, and the amplifier lattice parameters. The theory is compared with the results of the numerical calculations of the gain based on simulations of the electron beam transport through the amplifier lattice. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Test Results of Fast Decaying Current-Induced AC Losses in SHMS Superconducting Magnets at Jefferson Lab

The 11 GeV Super High Momentum Spectrometer (SHMS) of Hall C, part of the recent 12 GeV accelerator Upgrade at Jefferson Lab, was successfully commissioned in 2017. Fast current discharges of the SHMS Q2, Q3 quadrupoles and dipole superconducting magnets experienced some level of operational difficulty, during commissioning and normal operation. Measurements and analyses demonstrate that the fast current discharge leads to substantial AC losses in the conductor and subsequently triggers a quench-back effect. The details of the measurements and analyses have been reported previously. This paper focuses on the test results of the magnets using a reduced value of the protection dump resistor for each magnet to lower the current decay rate. Finally, the test results confirmed that the reduced dump resistances eliminated the quench-back effect for the SHMS Q2, Q3 and Dipole magnets, thus improving their cryogenic operability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The hypernuclear physics program at Jefferson Lab

Missing mass spectroscopy of Λ hypernuclei using the (e, e' K⁺) re action has been performed in the past at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) by several experiments in Halls A and C. A new experimen tal campaign is expected to start running in 2026 in Hall C and to provide the first study of the isospin dependence in medium-mass hyperisotopes by populating $^{40}_Λ{K}$ and $^{48}_Λ{K}$ using isotopically enriched calcium targets [E12-15-008]. During this cam paign, it will be possible to study Λ interactions in nuclear matter using a lead target [E12-20-013]. Solid-state targets made of lithium, beryllium, boron [LOI12-23-013], and aluminum [LOI12-23-016] are considered to be included in the campaign. The use of the HKS and HES spectrometers together with thin target foils and high beam currents leads to a sub-MeV energy resolution, significantly better than in hadron beam experiments. Valuable information on few-body hyperon systems would be gained if helium targets were used [E12-19-002]. Using an additional spectrometer for measuring the decay-pion spectra could give access to the binding energies of light hyperfragments [LOI12-23-011]. The measurement of precise and accurate en ergy spectra of different hyperisotopes probes the Λ-N interaction in nuclei including the Λ-N-N interaction. The latter is assumed to play a key role for the stiffness of the nuclear equation of state relevant for the stability of neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Cell-Centered Implicit Numerical Scheme for Ions in the 2-D Axisymmetric Code Hall2de

We present a new algorithm in the Hall2De code to simulate the ion hydrodynamics in the acceleration channel and near plume regions of Hall-effect thrusters. This implementation constitutes an upgrade of the capabilities built in the Hall2De code. The equations of mass conservation and momentum for unmagnetized ions are solved using a conservative, finite-volume, cell-centered scheme on a magnetic-field-aligned grid. Major computational savings are achieved by making use of an implicit predictor/multi-corrector algorithm for time evolution. Inaccuracies in the prediction of the motion of low-energy ions in the near plume in hydrodynamics approaches are addressed by implementing a multi-fluid algorithm that tracks ions of different energies separately. A wide range of comparisons with measurements are performed to validate the new ion algorithms. Several numerical experiments with the location and value of the anomalous collision frequency are also presented. Differences in the plasma properties in the near-plume between the single fluid and multi-fluid approaches are discussed. We complete our validation by comparing predicted erosion rates at the channel walls of the thruster with measurements. Erosion rates predicted by the plasma properties obtained from simulations replicate accurately measured rates of erosion within the uncertainty range of the sputtering models employed.

electric propulsion↗

Measurement of the EMC Effect of the Helium-3 Nucleus at Jefferson Lab

The MARATHON (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A=3 EMC Effect in Deep Inelastic Scattering Off the Tritium and Helium MirrOr Nuclei) experiment ran in the Hall A Facility of the Thomas Jefferson National Accelerator Facility (JLab). The experiment used a 10.59 GeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) of JLab to measure the ratio of the F2 structure functions of Helium-3 and Deuterium. Data were taken in the kinematic range of 0.195 lte x lte 0.825, 2.5 (GeV/c)2 lte Q2 lte 13 (GeV/c)2, and 3.5 (GeV/c2)^2 lte W^2 lte 13 (GeV/c2)^2. This is the first measurement of the 3He EMC effect that is purely in the Deep Inelastic Scattering region. The results of this experiment constitute an important, complimentary addition, to the limited data presently available for the EMC effect of light nuclei. The MARATHON results are compared to the world data for light, medium, and heavy nuclei. This measurement is considered an essential component to uncovering the nature of the EMC effect.

Hague, Tyler↗

Deep Multitask Learning Models for Radiation Estimation at High Energy Accelerator Facility

Controlling the dose of radiation exposure in potential radioactive facilities is critical for ensuring the safety of staff and the public. Here, in this paper, we developed machine learning models to estimate radiation exposure efficiently at the Thomas Jefferson National Accelerator Facility (JLab), aiming to enhance safety in both accelerator facilities and public areas. Multiple sensors were deployed around the three experimental halls at JLab. Data on single-beam currents, energy levels, and radiation values at the sensor locations were collected during accelerator operation. We proposed a multi-task learning model for radiation estimation, utilizing either one-dimensional convolutional neural networks (1-D CNNs) or long short-term memory networks (LSTMs) as the backbone. The proposed model was trained to simultaneously estimate radiation levels at the sensor locations. Experimental results demonstrated that the proposed model with LSTM backbone achieved the best estimation performance, with an average R 2 score of 0.7557 for estimation within the same year and 0.7157 for estimation across different years. These results significantly surpassed those of competing models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Cylindrical Hall-Effect Thruster Using Permanent Magnets

While annular Hall thrusters can operate at high efficiency at kW power levels, it is difficult to construct one that operates over a broad envelope from 1 kW down to 100 W while maintaining an efficiency of 45-55%. Scaling to low power while holding the main dimensionless parameters constant requires a decrease in the thruster channel size and an increase in the magnetic field strength. Increasing the magnetic field becomes technically challenging since the field can saturate the miniaturized inner components of the magnetic circuit and scaling down the magnetic circuit leaves very little room for magnetic pole pieces and heat shields. In addition, the central magnetic pole piece defining the interior wall of the annular channel can experience excessive heat loads in a miniaturized Hall thruster, with the temperature eventually exceeding the Curie temperature of the material and in extreme circumstances leading to accelerated erosion of the channel wall. An alternative approach is to employ a cylindrical Hall thruster (CHT) geometry. Laboratory model CHTs have operated at power levels ranging from 50 W up to 1 kW. These thrusters exhibit performance characteristics that are comparable to conventional, annular Hall thrusters of similar size. Compared to the annular Hall thruster, the CHTs insulator surface area to discharge chamber volume ratio is lower. Consequently, there is the potential for reduced wall losses in the channel of a CHT, and any reduction in wall losses should translate into lower channel heating rates and reduced erosion, making the CHT geometry promising for low-power applications. This potential for high performance in the low-power regime has served as the impetus for research and development efforts aimed at understanding and improving CHT performance. Recently, a 2.6 cm channel diameter permanent magnet CHT (shown in Fig. 1) was tested. This thruster has the promise of reduced power consumption over previous CHT iterations that employed electromagnets. Data are presented to expose the effect different controllable parameters have on the discharge and to summarize performance measurements (thrust, Isp, efficiency) obtained using a thrust stand. In addition, beam current data are presented to show the effect of the magnetic field topology on the plume profile and current utilization and to gain insight into the thruster s operation. These data extend and improve upon the results previously presented by the authors in Ref. [1].

Polzin, Kurt A.↗

An extraction scheme for future CEBAF FFA based energy upgrade

Jefferson lab is considering an energy increase from current 12 GeV to 22 GeV for its CEBAF accelerator. This will be accomplished by recirculating 5-6 additional turns through two parallel CEBAF LINACs using an FFA arc at each end of the racetrack. The total recirculation turns would be 10 times, the first four turns use present conventional arcs to make the 180-degree bends from one LINAC to the other. However, the last 5-6 turns will all share a single beam line inside two FFA arcs. This reduces the footprint and the cost of the project significantly. On the other hand, having the trajectories of last 5-6 recirculating beams close to each other makes it challenging to extract beams from different passes with different energies. In this paper we will explain our present extraction system for 12 GeV, our challenges and limitations, and a possible extraction solution for the 22 GeV upgrade with the goal of extracting beam at different turns/energies to different experimental halls.

Accelerator Physics↗

Advanced Diagnostics of Broad Spectrum Multipactor

Multipactor is a resonance event between electron emission and RF fields causing exponential secondary electron re-emission growth when the secondary electron yield of the primary electron impact energy exceeds unity. Multipactor is a serious problem in vacuum electron devices (VEDs) such as particle accelerators, radars, electronic warfare systems, directed energy devices, and even Hall effect thrusters. It also poses an even greater threat to space communication systems where high power, multi-channel links are required. The UC Davis and SLAC team will conduct basic research to advance the fundamental understanding of multipactor physics by developing and carrying out full spectrum, radio frequency (RF) laboratory tests aimed at understanding both single and two-surface multipactor phenomena and at evaluating novel multipactor mitigation approaches for accelerator, space-based RF systems, as well as high power microwave (HPM) applications.

36 MATERIALS SCIENCE↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. The system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems and in required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled, multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems and the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

43 PARTICLE ACCELERATORS↗

Enhanced reduction of velocity data obtained during CETA flight experiment

A newly developed technique for enhanced data reduction provides an improved procedure that allows least squares minimization to become possible between data sets with an unequal number of data points. This technique was applied in the Crew and Equipment Translation Aid (CETA) experiment on the STS-37 Shuttle flight in April 1991 to obtain the velocity profile from the acceleration data. The new technique uses a least-squares method to estimate the initial conditions and calibration constants. These initial conditions are estimated by least-squares fitting the displacements indicated by the Hall-effect sensor data to the corresponding displacements obtained from integrating the acceleration data. The velocity and displacement profiles can then be recalculated from the corresponding acceleration data using the estimated parameters. This technique, which enables instantaneous velocities to be obtained from the test data instead of only average velocities at varying discrete times, offers more detailed velocity information, particularly during periods of large acceleration or deceleration.

Finley, Tom D.↗

Enhanced data reduction of the velocity data on CETA flight experiment

A newly developed technique for enhanced data reduction provides an improved procedure that allows least squares minimization to become possible between data sets with an unequal number of data points. This technique was applied in the Crew and Equipment Translation Aid (CETA) experiment on the STS-37 Shuttle flight in April 1991 to obtain the velocity profile from the acceleration data. The new technique uses a least-squares method to estimate the initial conditions and calibration constants. These initial conditions are estimated by least-squares fitting the displacements indicated by the Hall-effect sensor data to the corresponding displacements obtained from integrating the acceleration data. The velocity and displacement profiles can then be recalculated from the corresponding acceleration data using the estimated parameters. This technique, which enables instantaneous velocities to be obtained from the test data instead of only average velocities at varying discrete times, offers more detailed velocity information, particularly during periods of large acceleration or deceleration.

Finley, Tom D.↗