Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT BALANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impurity transport studies at the HSX stellarator using active and passive CVI spectroscopy

The transport of carbon impurities has been studied in the helically symmetric stellarator experiment (HSX) using active and passive charge exchange recombination spectroscopy (CHERS). For the analysis of the CHERS signals, the STRAHL impurity transport code has been re-written in the python programming language and optimized for the application in stellarators. In addition, neutral hydrogen densities both along the NBI line of sight as well as for the background plasma have been calculated using the FIDASIM code. By using the basinhopping algorithm to minimize the difference between experimental and predicted active and passive signals, significant levels of impurity diffusion are observed. In this work, comparisons with neoclassical calculations from DKES/PENTA show that the inferred levels exceed the neoclassical transport by about a factor of four in the core and more than 100 times towards the plasma edge, thus indicating a high level of anomalous transport. This observation is in agreement with experimental heat diffusivites determined from a power balance analysis which exhibits strong anomalous transport as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation and evolution of protostellar accretion discs – II. From 3D simulation to a simple semi-analytic model of Class 0/I discs

Here we use a 3D radiative non-ideal magnetohydrodynamic simulation to investigate the formation and evolution of a young protostellar disc from a magnetized pre-stellar core. The simulation covers the first ${\sim }10\, {\rm kyr}$ after protostar formation and shows a massive, weakly magnetized disc with radius that initially grows and then saturates at ${\sim }30\, {\rm au}$. The disc is gravitationally unstable with prominent large-amplitude spiral arms. We use our simulation results and a series of physical arguments to construct a predictive and quantitative physical picture of Class 0/I protostellar disc evolution from several aspects, including (i) the angular-momentum redistribution in the disc, self-regulated by gravitational instability to make most of the disc marginally unstable; (ii) the thermal profile of the disc, well-approximated by a balance between radiative cooling and accretion heating; and (iii) the magnetic-field strength and magnetic-braking rate inside the disc, regulated by non-ideal magnetic diffusion. Using these physical insights, we build a simple 1D semi-analytic model of disc evolution. We show that this 1D model, when coupled to a computationally inexpensive simulation for the evolution of the surrounding pseudo-disc, can be used reliably to predict disc evolution in the Class 0/I phase. The predicted long-term evolution of disc size, which saturates at ${\sim }30\, {\rm au}$ and eventually shrinks, is consistent with a recent observational survey of Class 0/I discs. Such hierarchical modelling of disc evolution circumvents the computational difficulty of tracing disc evolution through Class 0/I phase with direct, numerically converged simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of Vegetation Canopy Architecture on Dynamics of Spatiotemporal Light Distribution and its Effect on Land-Biosphere-Atmosphere Fluxes of Energy, Carbon, and Water

The dynamic spatiotemporal distribution of light and micro climatic variables (wind speed, atmospheric CO 2 concentration, humidity, pressure, and air temperature) within the plant canopy as determined by the canopy architecture play a critical role in land-biosphere-atmosphere (LBA) photosynthetic carbon uptake, transpiratory water loss and energy partitioning. Vegetation models that include effects of sun and shade flecks, leaf temperature and energy balance partitioning between sensible and latent heat fluxes, and reduced turbulent mixing in dense vegetation canopies can accurately predict canopy performance, particularly its shaded leaves, which can constitute 80% of leaf area and contribute up to 50% of carbon update and 65% of water loss. However, current vegetation models with their bulk characterization of shaded leaves poorly represent the complex three dimensional (3D) canopy architecture are insufficient to capture the spatiotemporal dynamics of shaded leaves. Here, we propose to employ an x-ray computed tomography (XCT) imaging technique in combination with an automated, high throughput, image processing pipeline (3DArch, to be developed) to obtain an explicit 3D triangulated surface mesh of a plant canopy (Fig 1). 3DArch would provide a much needed technological jump in 3D LBA modeling where computer generated artificial 3D models suffer from lack of high resolution detailed canopy architecture parameters. The 3D canopy surface mesh output from 3DArch is coupled with an explicit 3D forward ray tracing model (fastTracer) to obtain a high resolution representation of the dynamic spatiotemporal light environment within the canopy over the course of a day (Fig 1). The results from the light attenuation model are then coupled with a process based multi-scale bio-physical canopy and leaf model of photosynthesis (PlantGro) to get fluxes of carbon, water and energy at the leaf and canopy scale, in addition to estimating whole plant carbon uptake, and water loss. Our proposed model framework would be the first of its kind to provide a breakthrough capability in the field of process-based plant modeling that bridges the key technological gap in shaded leaf modeling through explicit representation of 3D canopy architecture. Computer generated artificial 3D model canopy simulations on grasses show that the canopy light distribution does not follow an exponential behavior as assumed in most 1D vegetation models, but rather exhibits a heterogeneous behavior, with a small but significant portion of interior canopy leaves experiencing peak light levels due to sun flecks while the rest of the canopy receives substantially lower light levels. These results indicate a bias in traditional models that overestimates shaded leaf contribution towards whole canopy photosynthesis by up to 15% and underestimate transpiration by up to 12% with an associated increase in sensible heat fluxes since photosynthesis, transpiration and energy partitioning are tightly coupled processes. However, these test results need to be validated using the 3D architecture obtained from a real plant imaged in 3D using 3DArch, rather than an artificial model plant. Our proposed model framework would allow us to identify inefficiencies in canopy light distribution and prescribe optimal canopy architectures (leaf optical properties, leaf area, leaf angles, row spacing, planting density, etc.) to traditional and genetic engineering based crop breeders, for maximizing target functions such as light use efficiency, water use efficiency, drought tolerance, crop yield, crop resilience etc., with important applications in biofuel crops such as sorghum, and switchgrass. Our model can also be applied for designing optimal canopy architecture that increase surface albedo as a mitigation strategy for global warming and projections of crop yield for future food and water security under climate change.

59 BASIC BIOLOGICAL SCIENCES↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Stability Analysis of Astrophysical Cooling Functions

To model the temperature evolution of optically thin astrophysical environments at MHD scales, radiative and collisional cooling rates are typically either pretabulated or fit into a functional form and then input into MHD codes as a radiative loss function. Thermal balance requires estimates of the analogous heating rates, which are harder to calculate, and due to uncertainties in the underlying dissipative heating processes these rates are often simply parameterized. The resulting net cooling function defines an equilibrium curve that varies with density and temperature. Such cooling functions can make the gas prone to thermal instability (TI), which will cause departures from equilibrium. There has been no systematic study of thermally unstable parameter space for nonequilibrium states. Motivated by our recent finding that there is a related linear instability, catastrophic cooling instability, that can dominate over TI, here we carry out such a study. We show that Balbus instability criteria for TI can be used to define a critical cooling rate, Λ c , that permits a nonequilibrium analysis of cooling functions through the mapping of TI zones. We furthermore illustrate how thermal conduction modifies the shape of TI zones. Upon applying a Λ c -based stability analysis to coronal loop simulations, we find that loops undergoing periodic episodes of coronal rain formation are linearly unstable to catastrophic cooling instability, while TI is stabilized by thermal conduction.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical Analysis of Novel Plate Type Heat Exchanger with Oval-Twisted Channels

The novel heat exchanger (HX) designs implementing geometrical and surface modification combinations are expected to perform better than traditional HX technologies. Applied enhancement techniques seek to achieve (1) higher overall heat transfer performance, (2) increased compactness, and (3) simplified or comparable manufacturability. One innovative enhancement technique is to generate swirling flow vortices induced by channel or tube twisting. The turbulence generated by the twisted cross-section greatly enhances the heat transfer rate with minimal increases in pressure drop. Plate-type HXs and Printed Circuit Heat Exchangers (PCHXs) are compact designs that achieve high heat transfer rates per unit volume by utilizing several small channels, which maximizes the heat transfer surface area between the hot and cold fluids. Currently, advanced manufacturing technologies enable the design and fabrication of compact-type units with complicated channel geometries to achieve the highest performance and meet the compactness criteria of innovative HX technology. The proposed HX design concept combines the compactness of plate-type HXs and twisted channels, which provide additional turbulence and flow swirl enhancement. The plate-type oval-twisted HX (PTOTHX) is a crossflow configuration, with 16 short channels on one side (for hot fluid) and 8 long channels on the perpendicular side (for cold fluid). The inlet plenums have flow guide vanes to redirect flow and produce uniformity across the various flow paths. The compact size and purportedly improved heat transfer performance of the PTOTHX investigated herein prove its viability in various applications. Some notable potential nuclear applications of the PTOTHX include reactor core, spent fuel cooling, and residual heat dissipation. To establish a reference case, circular channels (PTCHX) are also considered in the present study for comparison with (PTOTHX). This paper aims to outline the numerical analysis procedures for determining the viability of the PTOTHX by comparing its heat transfer performance with the PTCHX units. The computational study used STAR-CCM+, a commercial computational fluid dynamics (CFD) code. Sensitivity analysis and model selection studies are conducted to determine the appropriate mesh density and turbulence model to provide the reported results. Numerical analyses comparing the Nusselt number (Nu) of the PTOTHX design with a comparable HX unit, including a circular cross-section and no twisting (PTCHX), show an overall heat transfer performance increase of 29-55% for balanced flow and 29-59% for imbalanced flow. Oval-cross-sectional twisted channels induce swirling flow vortices, enhancing the working fluid's convective heat transfer capabilities.

25 ENERGY STORAGE↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduced photothermal heating in diamonds enriched with H3 point defects

Solid-state laser refrigeration of semiconductors remains an outstanding experimental challenge. In this work, we show that, following excitation with a laser wavelength of 532 nm, bulk diamond crystals doped with H3 centers both emit efficient up-conversion (anti-Stokes) photoluminescence and also show significantly reduced photothermal heating relative to crystals doped with nitrogen–vacancy (NV) centers. The H3 center in diamond is a highly photostable defect that avoids bleaching at high laser irradiances of 10–70 MW/cm 2 and has been shown to exhibit laser action, tunable over the visible band of 500–600 nm. Here, the observed reduction of photothermal heating arises due to a decrease in the concentration of absorbing point defects, including NV-centers. These results encourage future exploration of techniques for H3 enrichment in diamonds under high-pressure, high-temperature conditions for the simultaneous anti-Stokes fluorescence cooling and radiation balanced lasing in semiconductor materials. Reducing photothermal heating in diamond through the formation of H3 centers also opens up new possibilities in quantum sensing via optically detected magnetic resonance spectroscopy at ambient conditions.

42 ENGINEERING↗

Data for: A hybrid biophysical-machine learning framework for diurnal surface energy flux estimation using proximal sensing

Thermal-based remote sensing of surface energy fluxes has traditionally relied on high spatial resolution satellite data with revisit frequencies on the order of weeks. In this study, we evaluate a biophysics-based analytical surface energy balance model for predicting latent energy (LE) and sensible heat (H) fluxes using proximal sensing observations. The Surface Temperature Initiated Closure (STIC1.2) model has been extensively validated across a wide range of spatial and temporal scales using various satellite-derived thermal datasets. Here we extend this validation by applying STIC at sub-hourly temporal resolution over multiple growing seasons for four distinct agricultural systems. We further develop and evaluate novel STIC variants that incorporate machine learning (ML) techniques to eliminate the need for specific surface energy balance observations, specifically net radiation and soil heat flux, thereby enhancing model applicability in data-sparse settings. The integration of an ML component to estimate surface available energy is shown to have strong predictive performance for both LE (R2 = 0.81-0.94) and H (R2 = 0.46-0.72) across all agricultural systems examined here, demonstrating the potential of hybrid biophysical – machine learning approaches for surface energy balance modeling with minimal data requirements. This study concludes with a novel application of explainable machine learning (exML) to diagnose sources of model error. This exML framework attributes residual prediction errors to both model input variables and environmental drivers not explicitly included in the simulation experiments. This approach provides a new pathway for improving model design and integrating previously overlooked yet influential variables into future model iterations.

Agricultural Sciences↗

A Hybrid Biophysical‐Machine Learning Framework for Diurnal Surface Energy Flux Estimation Using Proximal Sensing

Thermal infrared-based remote sensing of surface energy fluxes has traditionally relied on high spatial resolution satellite data with revisit frequencies on the order of weeks. In this study, we evaluate a biophysics-based analytical surface energy balance model for predicting latent energy ( LE ) and sensible heat ( H ) fluxes using proximal sensing observations. The Surface Temperature Initiated Closure (STIC1.2) model has been extensively validated across a wide range of spatial and temporal scales using various satellite-derived thermal infrared data sets. Here we extend this validation by applying STIC at sub-hourly temporal resolution over multiple growing seasons for four distinct agricultural systems. We further develop and evaluate novel STIC variants that incorporate machine learning (ML) techniques to eliminate the need for surface energy balance observations, specifically net radiation and soil heat flux, thereby enhancing model applicability in data-sparse settings. The integration of a ML component to estimate surface available energy is shown to have strong predictive performance for both LE (R 2 = 0.81–0.94) and H (R 2 = 0.46–0.72) across all agricultural systems examined here, demonstrating the potential of hybrid biophysical-machine learning approaches for surface energy balance modeling with minimal data requirements. This study concludes with a novel application of explainable machine learning (exML) to diagnose sources of model error. This exML framework attributes residual prediction errors to both model input variables and environmental drivers not explicitly included in the simulation experiments. This approach provides a new pathway for improving model design and integrating previously overlooked yet influential variables into future model iterations.

evapotranspiration↗

High-performance plasmas after pellet injections in Wendelstein 7-X

A significant improvement of plasma parameters in the optimized stellarator W7-X is found after injections of frozen hydrogen pellets. The ion temperature in the post-pellet phase exceeds 3 keV with 5 MW of electron heating and the global energy confinement time surpasses the empirical ISS04-scaling. The plasma parameters realized in such experiments are significantly above those in comparable gas-fuelled discharges. Here, we present details of these pellet experiments and discuss the main plasma properties during the enhanced confinement phases. Local power balance is applied to show that the heat transport in post-pellet phases is close to the neoclassical level for the ion channel and is about a factor of two above that level for the combined losses. In comparable gas-fuelled discharges, the heat transport is by about ten times larger than the neoclassical level, and thus is largely anomalous. It is further observed that the improvement in the transport is related to the peaked density profiles that lead to a stabilization of the ion-scale turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring the Meteorological Impacts of Surface and Rooftop Heat Mitigation Strategies Over a Tropical City

Different heat mitigation technologies have been developed to improve the thermal environment in cities. However, the regional impacts of such technologies, especially in the context of a tropical city, remain unclear. The deployment of heat mitigation technologies at city-scale can change the radiation balance, advective flow, and energy balance between urban areas and the overlying atmosphere. We used the mesoscale Weather Research and Forecasting model coupled with a physically based single-layer urban canopy model to assess the impacts of five different heat mitigation technologies on surface energy balance, standard surface meteorological fields, and planetary boundary layer (PBL) dynamics for premonsoon typical hot summer days over a tropical coastal city in the month of April in 2018, 2019, and 2020. Results indicate that the regional impacts of cool materials (CMs), super-cool broadband radiative coolers, green roofs (GRs), vegetation fraction change, and a combination of CMs and GRs (i.e., “Cool city (CC)”) on the lower atmosphere are different at diurnal scale. Results showed that super-cool materials have the maximum potential of ambient temperature reduction of 1.6°C during peak hour (14:00 LT) compared to other technologies in the study. During the daytime hours, the PBL height was considerably lower than the reference scenario with no implementation of strategies by 700 m for super-cool materials and 500 m for both CMs and CC cases; however, the green roofing system underwent nominal changes over the urban area. During the nighttime hours, the PBL height increased by CMs and the CC strategies compared to the reference scenario, but minimal changes were evident for super-cool materials. The changes of temperature on the vertical profile of the heat mitigation implemented city reveal a stable PBL over the urban domain and a reduction of the vertical mixing associated with a pollution dome. This would lead to crossover phenomena above the PBL due to the decrease in vertical wind speed. Therefore, assessing the coupled regional impact of urban heat mitigation over the lower atmosphere at city-scale is urgent for sustainable urban planning.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric Gases as Quantitative Indicators of Urbanization Across Land-Use Gradients

The urban heat island (UHI) effect is a significant phenomenon characterized by higher surface temperatures in cities compared to surrounding rural areas. This change in the Earth's energy balance presents considerable challenges for urban populations, increasing heat exposure, straining energy infrastructure, and exacerbating health vulnerabilities. Quantifying UHI intensity is challenging due to blurred distinctions between urban and rural areas as land-use patterns evolve. To address this challenge, the present study builds on the framework established by Salvador et al. (2025) and investigates the use of atmospheric constituents, specifically volatile organic compounds (VOCs) and inorganic gases, as tracers of urbanization levels. A key improvement in this approach is the inclusion of a designated true rural site for comparison. Field measurements were conducted at two locations in the Southeastern United States during the summer of 2025. Inorganic gases were monitored continuously, while VOC samples were collected biweekly and analyzed using a proton transfer reaction time-of-flight mass spectrometer. The urban site exhibited elevated concentrations of anthropogenic inorganic gases, with carbon monoxide and nitrogen dioxide averaging 878 ppb and 17.99 ppb, respectively. In contrast, the rural site showed lower levels of these pollutants, 796 ppb for carbon monoxide and 12.46 ppb for nitrogen dioxide, while displaying higher concentrations of biogenic VOCs, including isoprene and monoterpenes at 1.24 ppb and 0.08 ppb, respectively. Extended mass spectral analyses revealed distinct chemical differences between the two sites, supporting the observed variability of major gases. Overall, these findings are consistent with our previous research and highlight the value of atmospheric constituents as effective indicators of urbanization, thereby improving our understanding of UHI dynamics.

54 ENVIRONMENTAL SCIENCES↗

Experimental Investigation of a Phase Change Material Charged Finned-Tube Heat Exchanger

Understanding different thermal performance aspects of phase change material heat exchangers (PCM-HX) is critical for designing future energy-efficient thermal energy storage systems. This paper presents an experimental performance analysis of a vertically oriented annular finned-tube PCM-HX in a cylindrical container tested under six different melting and solidification test conditions, varied by heat transfer fluid’s (HTF) inlet temperatures and flow directions. The PCM-HX structure with 20 evenly spaced fins was 3D printed in aluminum, and the PCM-HX container was 285 mm in height. The PCM-HX average porosity was 89.7%, where the PCM mass was 246.4 g. Water served as the HTF, and a PCM with a nominal phase change temperature of 35 °C was selected. Instead of opaque conventional insulation sheets, a combination of air-and-argon-filled see-through insulation cylinders was assembled with the PCM-HX to visualize the phase-change phenomena, while minimizing the uncertainties due to heat loss. In total, there were 78 T-type thermocouples installed in the test section which allows a more precise assessment of thermal mass and heat loss, which are often neglected in similar studies found in the literature. We validated the reliability of the test facility as the repeated test results had negligible deviations under the same test conditions. The energy balances between the estimated theoretical and experimentally calculated PCM storage, considering heat loss and thermal mass, were within ±9% deviation for all test conditions. From the experimental investigations, we made several following observations. It was found that the melting pattern of the finned-tube PCM-HX with small gaps between the container wall and the fins was largely affected by the HTF flow directions, unlike the typical straight annular tube PCM-HX. For effective charging and discharging processes, a combination of upward melting and downward solidification is recommended to shorten the test duration. However, an upward solidification should be considered to minimize the cavity formation between the fins caused by the PCM volume contraction during the solidification process.

25 ENERGY STORAGE↗

FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment (Final Report)

This report documents the FY25 Theory and Simulation Performance Target (TSPT) of developing an integrated modeling framework for fusion reactor design and assessment (FREDA). Over Q1-Q4, new capabilities were developed across both plasma and engineering domains and demonstrated on an example representation of a Compact Advanced Tokamak with a Dual Cooled Lead Lithium blanket. This represents a first-of-a-kind demonstration of coupled core-to-wall-to-engineering for a reactor. Self-consistent CESOL workflows were applied to provide core, pedestal, and SOL prediction; new modules were developed for energetic particle stability (FAR3D) and transport (TGLF-EP) analysis; and boundary plasma modeling (SOLPS-ITER, BOUT++/Hermes-3) was expanded to evaluate wall and divertor heat fluxes and interface with engineering thermal analysis. A parameterized CAD tool, TRACER, was expanded to generate medium-fidelity divertor, blanket, and coil geometries; OpenFOAM and Diablo workflows were applied for first-wall and divertor thermal analyses with helium cooling; and reduced-order models were created for high-mass-flux divertor cooling. Magnet multiphysics capabilities were verified between Elmer, Diablo, and a new MFEM-based solver, and workflows enable stress, thermal, and neutron-fluence analysis of TF coils with neutronics-driven heating. Nuclear and blanket analysis workflows were demonstrated, including tritium breeding, transport, and CFD-informed thermo-mechanical assessment. Preliminary multi-fidelity uncertainty quantification workflows were applied to boundary modeling codes and shown to achieve variance reductions with fewer high-fidelity boundary simulations. Key findings highlight the challenges of resolving the ITEP gap to find suitable balance between wall and divertor loads, neutron heating, and practical limits of PFC cooling. Next step priorities are to develop automated workflows to check boundary code convergence and detachment, implement tighter physics-engineering CAD provenance tracking, and inclusion of plasma-material interface models for SLAG and tungsten cracking behavior. Collectively, these developments establish sophisticated capabilities for predictive, multi-fidelity, whole-device modeling that integrates plasma physics, materials, magnets, and nuclear engineering to guide pathways to viable Fusion Pilot Plant design points.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Klickitat Valley Health Central Utility Plant Modernization

This project replaced legacy heating and cooling equipment at Klickitat Valley Health (KVH), a rural hospital in Goldendale, Washington. Work included constructing a new chiller building, installing modern hydronic piping systems, replacing the main Emergency Department air handler (Air Handlining Unit (AHU-1)), upgrading electrical systems, and converting the Emergency Department wing from electric reheat to hydronic heating and cooling. Commissioning, testing, adjusting, and balancing were completed under this grant. These upgrades improve energy efficiency, operational resilience, and system reliability while preparing the campus for future electrification and renewable energy integration. They also support growth in healthcare services for a rural population. The project directly reduces energy costs and provides a foundation for future decarbonization measures, including a FEMA-funded microgrid and a large-scale ground source heat pump (GSHP) project. These follow-on initiatives would not have been possible without the hydronic backbone built through this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗