Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT FLUX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A network of soil moisture, soil temperature, air temperature, net radiation, ground heat flux and ground water for Chicago, Illinois

This dataset contains environmental monitoring data collected using solar-powered Multi-Function Research (MFR) Long Range Wide Area (LoRaWAN)-enabled nodes at 11 sites in Chicago, Illinois, as part of the DOE Urban Integrated Field Lab CROCUS project. The MFR node system consists of an Input/Output Digital Input Module (IB8) interface box (ICT International) providing wired connections for environmental sensors and an MFR-Node-L data logger that manages power, data processing, and LoRaWAN communication. The wireless data are ingested via Sage network (https://sagecontinuum.org/) nodes that contain LoRaWAN antennae. Measurements were collected from 11 MFR nodes deployed across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), West Woodlawn "Blacks in Green" (BIG), and Indian Boundary Prairies (IBP). Each MFR node supports a consistent suite of sensors measuring atmospheric, soil, and hydrological variables. Atmospheric measurements include 2m air temperature (°C), 2m vapor pressure deficit (kPa), and 2m shortwave/longwave radiation (incoming and outgoing, W/m²) measured using ATH-VPD and Apogee SN500 sensors. Soil measurements include volumetric water content (VWC, %) and temperature (°C) at four depths (15, 30, 45, and 60 cm below surface) using Meter Teros54 sensors, and heat flux (W/m²) at 10 cm depth using Huske HFP01-05 sensors. At selected locations, Meter Hydros21 sensors measure groundwater depth (mm), specific conductivity (dS/m), and temperature (°C). The dataset includes timestamps, site identifiers with location names, device IDs, Global Positioning System (GPS) coordinates, variable names with units, measurement depths, values, sensor names, and Sage node identifiers. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 6-bit binary system indicating physical range violations, step spikes, 24-hour flat-line conditions, 6-hour jitter, 7-day ultra-low variance, and persistent high offset. Data is provided in CSV and CF-compliant NetCDF formats. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Sap Flow Meter (SFM1x) sensors.

Chicago↗

Airborne Measurements of Scale‐Dependent Latent Heat Flux Impacted by Water Vapor and Vertical Velocity Over Heterogeneous Land Surfaces During the CHEESEHEAD19 Campaign

Abstract The water vapor transport associated with latent heat flux (LE) in the planetary boundary layer (PBL) is critical for the atmospheric hydrological cycle, radiation balance, and cloud formation. The spatiotemporal variability of LE and water vapor mixing ratio ( r v ) are poorly understood due to the scale‐dependent and nonlinear atmospheric transport responses to land surface heterogeneity. Here, airborne in situ measurements with the wavelet technique are utilized to investigate scale‐dependent relationships among LE, vertical velocity ( w ) variance (), and r v variance () over a heterogeneous surface during the Chequamegon Heterogeneous Ecosystem Energy‐balance Study Enabled by a High‐density Extensive Array of Detectors 2019 (CHEESEHEAD19) field campaign. Our findings reveal distinct scale distributions of LE, , and at 100 m height, with a majority scale range of 120 m–4 km in LE, 32 m–2 km in , and 200 m–8 km in . The scales are classified into three scale ranges, the turbulent scale (8–200 m), large‐eddy scale (200 m–2 km), and mesoscale (2–8 km) to evaluate scale‐resolved LE contributed by and . The large‐eddy scale in PBL contributes over 70% of the monthly mean total LE with equal parts (50%) of contributions from and . The monthly temporal variations mainly come from the first two major contributing classified scales in LE, , and . These results confirm the dominant role of the large‐eddy scale in the PBL in the vertical moisture transport from the surface to the PBL, while the mesoscale is shown to contribute an additional ∼20%. This analysis complements published scale‐dependent LE variations, which lack detailed scale‐dependent vertical velocity and moisture information.

54 ENVIRONMENTAL SCIENCES↗

Development of a High-Intensity Heat Flux Gauge and Characterization Facility (Final Report)

Sandia National Laboratories (SNL) and Hukseflux Thermal Sensors (HTS) collaborated to advance the design and calibration of high-intensity heat flux gauges capable of measuring 2500 kW/m². An industry trade study was first conducted and highlighted the need for enhanced gauge designs and calibration methodology & services suited for high-intensities and broadband flux. We then developed, tested, and evaluated three prototype gauge designs along with four distinct coating types, each designed to extend the measurable flux range of existing HTS products to higher intensity levels. Following a down selection process, the project team refined the focus to a final product design, incorporating updated features to enhance its robustness during high flux exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron heat flux and propagating fronts in plasma thermal quench via ambipolar transport

The thermal collapse of a nearly collisionless plasma interacting with a cooling spot, in which the electron parallel heat flux plays an essential role, is both theoretically and numerically investigated. Here, we show that such thermal collapse, which is known as thermal quench in tokamaks, comes about in the form of propagating fronts, originating from the cooling spot, along magnetic field lines. The slow fronts, propagating with local ion sound speed, limit the aggressive cooling of plasma, which is accompanied by a plasma cooling flow toward the cooling spot. The extraordinary physics underlying such a cooling flow is that the fundamental constraint of ambipolar transport along the field line limits the spatial gradient of electron thermal conduction flux to the much weaker convective scaling, as opposed to the free-streaming scaling, so that a large electron temperature and, hence, pressure gradient can be sustained. The last ion front for a radiative cooling spot is a shock front where cold but flowing ions meet hot ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controllable Solar Flux Heating for Freeze Recovery in Molten Salt Parabolic Trough Collectors

In molten-salt parabolic trough plants, the melting process is particularly important for freeze recovery of salt that is solidified in a collector loop, should such an event occur. Currently impedance heating is expected for freeze recovery of the collector loops, but this method can be expensive. Here, a lower-cost alternative is proposed to use controllable concentrated solar flux directly from the parabolic mirrors to thaw salt that is frozen in the collector. A computational fluid dynamics model was developed to explore the solidification and melting processes of molten salt in a parabolic trough receiver and to assess the viability of this concept. Results indicate that concentrated solar heating has the potential to melt frozen salt in 5.6 h, compared to that in 8.8 h for a 300 W m –1 impedance heating system. At the same time, controllable solar flux heating introduces nonuniform solar fluxes on the receiver surface, which can induce significant thermal stress on the receiver tube. A preliminary stress analysis indicates that the temperature difference across the receiver tube should be maintained below about 70 °C for heating up to 300 °C at internal pressures ≤10 bar. At these conditions, freeze recovery using solar flux heating will not significantly affect receiver lifetime. These results suggest that controllable solar flux heating could effectively supplement or replace impedance heating in the freeze recovery system. Incorporating this methodology in future parabolic trough concentrating solar power plants is an opportunity for capital and operational cost-savings.

14 SOLAR ENERGY↗

Intercomparison of sensible and latent heat flux measurements from combined eddy covariance, energy balance, and Bowen ratio methods above a grassland prairie

We present a comparison of four different methods of measuring sensible (H) and latent (LE) heat fluxes for a year over a mixed grass prairie ecosystem in the Nebraska SandHills [eddy covariance (EC), energy balance/Bowen ratio (EBBR), residual energy (RES), modified Bowen ratio (MBR) methods]. Additionally, we developed a set of quality control criteria for each method and present a simplification to the traditional EBBR setup. Using EC as reference, all methods yielded similar estimates of yearly H (regression slopes (m) ~ 2% from unity; H EC > H EBBR , H RES , and H MBR ). For yearly LE, EBBR and RES yielded similar estimates with EC (m ~ 2% from unity; LE EC < LE EBBR and LE RES ), while a larger bias was found from MBR (m ~ 8% from unity; LE EC > LE MBR ). At shorter time scales (~ hourly), moderate scatter was found about linear regression fits for H between EBBR and EC (R 2 = 0.81), with smaller scatter between RES and MBR, and EC (R 2 = 0.91). For LE, smaller scatter was also measured between EC, and EBBR and RES (R 2 = 0.89 and 0.87, respectively), with the larger scatter between EC and MBR (R 2 = 0.65). This suggests methods other than EC may be well suited to longer-term applications (≥ yearly), but have larger uncertainty on individual measurements.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity analysis of in-pile critical heat flux experiments in TREAT for characterization of RIA power-transient effects

A reactivity-initiated accident (RIA) is one type of postulated design basis accident (DBA) that can cause a departure from nucleate boiling (DNB) event in pressurized-water reactors (PWRs). A DNB occurrence and its consequences depend on the thermophysical properties of the fuel components and coolant, characteristics of the transient energy insertion into the fuel rod, and the onset of the critical heat flux (CHF) phenomenon. To leverage the restart of the Transient Reactor Test (TREAT) Facility, an effort is currently underway to better understand the cladding-to-coolant heat transfer mechanisms and the CHF phenomenon under fast-transient irradiation conditions. This paper characterizes the impact of power transients on the thermal-hydraulic behavior of a TREAT Facility reactor heater rodlet CHF experiment to provide the priority of parameters that need to be investigated for an improved CHF model. Sobol sensitivity analysis methods and the Reactor Excursion and Leak Analysis Program (RELAP5-3D) code were used to identify key input parameters on the uncertainty in the prediction of peak outer- and inner-surface temperatures of the heater tube, as well as the time of the DNB event. A series of sensitivity analyses revealed the total energy deposition on the tube and the transient effects of power pulse had large impacts on the maximum temperatures. The CHF multiplier had the largest impact on the time occurrence of CHF. The overall results show the energy deposition rate in the tube is the most influencing factor to the manifestation of CHF and the resulting thermal-hydraulic behaviors of the tube. The multiplier for the CHF, which is interpreted as the predicted CHF value, has the largest Sobol indices for the time of the CHF in all cases, since it directly determines the occurrence of CHF. It is inferred that the uncertainties in the thermal-hydraulic behaviors of fuels increase with respect to the key parameters as the power pulse becomes broader, and an accurate estimation of the energy deposition rate is required to reduce the uncertainty in the evaluation of the integrity of fuel if the CHF is expected to occur near the peak power. Therefore, the outputs are expected to provide rigorous interpretation of ongoing in-pile CHF experiments in the TREAT Facility reactor regarding thermal-hydraulic behavior of the fuel system aiming for a new transient in-pile CHF model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Threshold Heat-Flux Reduction by Near-Resonant Energy Transfer

Near-resonant energy transfer to large-scale stable modes is shown to reduce transport above the linear critical gradient, contributing to the onset of transport at higher gradients. This is demonstrated for a threshold fluid theory of ion temperature gradient turbulence based on zonal-flow-catalyzed transfer. Furthermore, the heat flux is suppressed above the critical gradient by resonance in the triplet correlation time, a condition enforced by the wave numbers of the interaction of the unstable mode, zonal flow, and stable mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review of Thermal Contact Resistance of Flexible Graphite Materials for Thermal Interfaces in High Heat Flux Applications

In this report the data is reviewed on thermal contact conductance (TCC) and/or thermal contact resistance (TCR) at material interfaces which employs flexible graphite (FG) materials as thermal interface materials (TIM). FG materials are often used as TIM due to their conforming nature. While the overall TCR can be estimated straightforward from measured data, the interface TCR is much more difficult to obtain. The report also discusses the interfacial thermal contact conductance between FG-tungsten and FG-Glidcop-Al15, which are envisioned for high-heat flux applications.

36 MATERIALS SCIENCE↗

Ion irradiation effects on Cr-coated zircaloy-4 surface wettability and pool boiling critical heat flux.

The concept of coating the currently used nuclear fuel cladding (zirconium-based alloy, typically Zircaloy-4 or Zirc-4) with an oxidation preventive layer is a progressing Accident tolerant Fuel (ATF) candidate alloys. The coated Zirc-4-based alloys could be a solution to suppress undesirable fast reaction kinetics with high-temperature steam. Zirc-4 has been the most preferred cladding material in pressurized water reactors (PWRs). Chromium (Cr) based alloys as a coating material provides excellent corrosion protection and good strength and wear resistance. In this paper, we present the surface wettability measurements and pool boiling Critical Heat Flux (CHF) for Cr-coated Zirc-4 claddings pre- and post-exposure to an ion irradiation environment. The wettability measurements, including static contact angle (contact angle, θ) and average surface roughness (surface roughness, Ra), are introduced for samples of different coating thicknesses (5–30 μm thick). The coatings fabricated by the cold spray of Cr-Al particles to 10 mm × 10 mm × 1.95 mm Zirc-4 substrates. Post fabrication, a Pilgering (cold rolling) process, was applied to finalize the coating thickness and resulted in a significant reduction in surface roughness of initially fabricated rough surfaces. The process produced three distinguished samples 5-μm unpolished (as machined), 5-μm, and 30-μm polished (cold rolled). The measurements are presented for the three surfaces and bare Zirc-4 as a baseline surface. The contact angle analyses were implemented in theoretical models from the literature to predict pool boiling CHF. Pool boiling experiments were conducted to measure the pool boiling CHF values and compare them to the predicted values. Scanning Electron Microscope (SEM) images and Energy Dispersive X-ray Spectroscopy (EDS) analysis was performed to characterize the surfaces for better understanding and interpreting the results. The SEM images showed localized surface damage due to ion irradiation. No recognized change in the measured surface roughness due to ion irradiation. The contact angles of irradiated Cr-coated surfaces are consistently higher (10°) than pre-irradiated surfaces. Decreasing the Cr-coating layer thickness resulted in lower contact angle pre- and post- ion irradiation. The predicted pool boiling CHF using the Kandlikar model is in good agreement with the experimentally measured CHF values within ±12% for all samples.

36 MATERIALS SCIENCE↗

The effect of relative humidity on eddy covariance latent heat flux measurements and its implication for partitioning into transpiration and evaporation

While the eddy covariance (EC) technique is a well-established method for measuring water fluxes (i.e., evaporation or 'evapotranspiration’, ET), the measurement is susceptible to many uncertainties. One such issue is the potential underestimation of ET when relative humidity (RH) is high (> 70%), due to low-pass filtering with some EC systems. Yet, this underestimation for different types of EC systems (e.g. open-path or closed-path sensors) has not been characterized for synthesis datasets such as the widely used FLUXNET2015 dataset. Here, we assess the RH-associated underestimation of latent heat fluxes (LE, or ET) from different EC systems for 163 sites in the FLUXNET2015 dataset. We found that the LE underestimation is most apparent during hours when RH is higher than 70%, predominantly observed at sites using closed-path EC systems, but the extent of the LE underestimation is highly site-specific. We then propose a machine learning based method to correct for this underestimation, and compare it to two energy balance closure based LE correction approaches (Bowen ratio correction, BRC, and attributing all errors to LE). Our correction increases LE by 189% for closed-path sites at high RH (> 90%), while BRC increases LE by around 30% for all RH conditions. Additionally, we assess the influence of these corrections on ET-based transpiration (T) estimates using two different ET partitioning methods. Results show opposite responses (increasing vs. slightly decreasing T-to-ET ratios, T/ET) between the two methods when comparing T based on corrected and uncorrected LE. Overall, our results demonstrate the existence of a high RH bias in water fluxes in the FLUXNET2015 dataset and suggest that this bias is a pronounced source of uncertainty in ET measurements to be considered when estimating ecosystem T/ET and WUE.

54 ENVIRONMENTAL SCIENCES↗

Development and testing of a solar flux heating freeze recovery system for molten salt parabolic troughs

A major obstacle preventing commercialization of molten salt parabolic trough plants is freeze protection and recovery of the solar field. One of the most common nitrate salt compositions under consideration allows for solar field outlet temperatures up to 565°C and begins solidifying above 240°C. Using molten salt directly in the solar field can significantly reduce thermal energy storage costs and the higher temperature compared to oil heat transfer fluids can power a more efficient power cycle, but the very high freezing point is cause for concern. This work builds on a previous modeling effort investigating different methods for melting Solar Salt frozen in the solar field, which suggested the viability of a novel solar heating method to lower costs of the freeze protection system. In this work higher fidelity models are developed to better investigate the melting process with a more detailed 3D geometry which includes the insulated bellows. The thermal-fluid model of the melting process is updated to include temperature dependent density and data for solid phase properties. In addition, a finite element model is developed to resolve thermal stresses at the point with highest thermal gradients. Results with the new model confirm the viability of using controllable solar flux heating to thaw salt frozen in the solar field without damaging the receiver; however, the presence of non-illuminated sections significantly slows down the melting process. Solar heating simulations with pauses off-sun of 120 and 60 s require 18.5 and 11.9 h to melt salt from a night-time temperature of 10°C with 1000 W m2 DNI, which results in maximum thermal stresses of 48.2 and 53.5 MPa, respectively. Adding 150 W m−1 to the solar heating simulation with a 60 s pause off-sun decreases both the melt time and thermal stresses due to the more uniform heating, suggesting a combined heating method may be the best option.

14 SOLAR ENERGY↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Flux Sensor Measurement and Calibration Requirements for High-Intensity Heat Flux Applications: A Trade Study

Stakeholders of CSP and non-CSP high-intensity broadband flux measurements were surveyed and interviewed to obtain flux sensor design and calibration requirements. Existing sensor technologies and existing calibration facilities were then compared against this standard. Stakeholders require a flux sensor designed for >5,000 kW/m2 flux measurements, >1,000 life cycles, <500 ms response time, >60-minute exposure at maximum flux, and <5% measurement uncertainty. Stakeholders also require a sensor with minimal cost, short procurement lead time, and a high-intensity broadband flux calibration. Commercial CSP stakeholders primarily rely on infrared (IR) temperature measurements of receiver equipment to control CSP plant process operation, whereas CSP research and development (R&D) and non-CSP stakeholders rely on accurate flux gauge measurements for a variety of applications. It was determined that existing flux sensor technologies and calibration facilities do not comprehensively meet stakeholder needs. This study suggests a more robust circular foil gauge with a high-intensity solar flux calibration comprehensively meets stakeholder flux measurement needs. Improved circular foil gauge designs and an improved flux sensor calibration facility are discussed.

McLaughlin, Luke (ORCID:0000000303711310)↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗