Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Low cycle fatigue behavior of polycrystalline NiAl at 300 and 1000 K

The low cycle fatigue behavior of polycrystalline NiAl was determined at 300 and 1000 K - temperatures below and above the brittle- to-ductile transition temperature (BDTT). Fully reversed, plastic strain-controlled fatigue tests were conducted on two differently fabricated alloy samples: hot isostatically pressed (HIP'ed) prealloyed powder and hot extruded castings. HIP'ed powder (HP) samples were tested only at 1000 K, whereas the more ductile cast-and-extruded (C+E) NiAl samples were tested at both 1000 and 300 K. Plastic strain ranges of 0.06 to 0.2 percent were used. The C+E NiAl cyclically hardened until fracture, reaching stress levels approximately 60 percent greater than the ultimate tensile strength of the alloy. Compared on a strain basis, NiAl had a much longer fatigue life than other B2 ordered compounds in which fracture initiated at processing-related defects. These defects controlled fatigue life at 300 K, with fracture occurring rapidly once a critical stress level was reached. At 1000 K, above the BDTT, both the C+E and HP samples cyclically softened during most of the fatigue tests in air and were insensitive to processing defects. The processing method did not have a major effect on fatigue life; the lives of the HP samples were about a factor of three shorter than the C+E NiAl, but this was attributed to the lower stress response of the C+E material. The C+E NiAl underwent dynamic grain growth, whereas the HP material maintained a constant grain size during testing. In both materials, fatigue life was controlled by intergranular cavitation and creep processes, which led to fatigue crack growth that was primarily intergranular in nature. Final fracture by overload was transgranular in nature. Also, HP samples tested in vacuum had a life three times longer than their counterparts tested in air and, in contrast to those tested in air, hardened continuously over half of the sample life, thereby indicating an environmentally assisted fatigue damage mechanism. The C+E samples were tested only in air. At 1000 K, NiAl exhibited a superior fatigue life when compared to most superalloys on a plastic strain basis, but was inferior to most superalloys on a stress basis.

Lerch, Bradley A.↗

Long-wave infrared (LWIR) detectors based on III-V materials

Future NASA missions for earth observation and planetary science require large photovoltaic detector arrays with high performance in the long wavelength region to 18 microns and at operating temperatures above 65 K where single-cycle long-life cryocoolers are being developed. Since these detector array requirements exceed the state of current HgCdTe technology, alternative detector materials are being investigated as a possible option for future missions. Advanced growth techniques (e.g., MBE and MOCVD) of column III-V semiconductors have opened opportunities for engineering new detector materials and device structures. The technical approaches under investigation at JPL (with university and industry participation) include: quantum well infrared photodetectors, heterojunction internal photoemission (HIP) photodetectors, type-II strained layer superlattices, and nipi doping superlattices. Each of these options are briefly described with some of their pros and cons. A more detailed description is given for the HIP approach being pioneered at JPL.

Maserjian, Joseph↗

Rhenium material properties

Tensile data were obtained from four different types of rhenium at ambient and elevated temperatures. The four types of rhenium included chemical vapor deposition (CVD) and three powder metallurgy (PM) types, i.e., rolled sheet and pressed and sintered bars, with and without hot isostatic pressure (HIP) treatment. Results revealed a wide range of values with ultimate strengths at ambient temperatures varying from 663 MPa for CVD rhenium to 943 MPa for rolled sheet. A similar spread was also obtained for material tested at 1088 K and 1644 K. The wide variance observed with the different materials indicated that the rhenium manufacturing process, material composition and prior handling strongly dictated its properties. In addition to tensile properties, CVD, pressed and sintered material and HIP rhenium successfully completed 100 cycles of low cycle fatigue. Creep data were also obtained showing that CVD and pressed and sintered rhenium could sustain five hours of testing under a tension of 27.5 MPa at 1922 K.

Biaglow, James A.↗

Infrared Detectors Containing Stacked Si(1-x)Ge(x)/Si Layers

Long-wavelength-infrared detectors containing multiple layers of high-quality crystalline p(+) Si(1-x)Ge(x) alternating with layers of Si undergoing development. Each detector comprises stack of Si(1-x)Ge(x)/Si heterojunction internal photoemission (HIP) photodetectors. In comparison with older HIP detectors containing single Si(1-x)Ge(x)/Si heterojunctions, developmental detectors feature greater quantum efficiencies and stronger photoresponses.

Park, Jin S.↗

The Effect of Boron on the Low Cycle Fatigue Behavior of Disk Alloy KM4

The durability of powder metallurgy nickel base superalloys employed as compressor and turbine disks is often limited by low cycle fatigue (LCF) crack initiation and crack growth from highly stressed surface locations (corners, holes, etc.). Crack growth induced by dwells at high stresses during aerospace engine operation can be particularly severe. Supersolvus solution heat treatments can be used to produce coarse grain sizes approaching ASTM 6 for improved resistance to dwell fatigue crack growth. However, the coarse grain sizes reduce yield strength, which can lower LCF initiation life. These high temperature heat treatments also can encourage pores to form. In the advanced General Electric disk superalloy KM4, such pores can initiate fatigue cracks that limit LCF initiation life. Hot isostatic pressing (HIP) during the supersolvus solution heat treatment has been shown to improve LCF initiation life in KM4, as the HIP pressure minimizes formation of the pores. Reduction of boron levels in KM4 has also been shown to increase LCF initiation life after a conventional supersolvus heat treatment, again possibly due to effects on the formation tendencies of these pores. However, the effects of reduced boron levels on microstructure, pore characteristics, and LCF failure modes in KM4 still need to be fully quantified. The objective of this study was to determine the effect of boron level on the microstructure, porosity, LCF behavior, and failure modes of supersolvus heat treated KM4.

Gabb, Timothy↗

Battling Brittle Bones

The accuDEXA(R) Bone Mineral Density Assessment System, manufactured by Schick Technologies, Inc., utilizes "camera on a chip" sensor technology invented and developed by NASA's Jet Propulsion Laboratory. Schick's accuDEXA system offers several advantages over traditional osteoporosis tests, which assess bone density loss in the hip and spine, and require specialized personnel to conduct. With accuDEXA, physicians can test the entire body's bone density at a peripheral site, such as the finger, without applying gels or having patients remove garments. Results are achieved in 30 seconds and printed out in less than a minute, compared to the estimated exam time of 15 minutes for hip and spine density analyses. Schick has also applied the CMOS APS technology to a new software product that performs dental radiography using up to 90 percent less radiation exposure than conventional X-rays. Called Computed Dental Radiography(R), the new digital imaging product utilizes an electronic sensor in place of X-ray film to generate sharp and clear images that appear on a computer screen within 3 seconds, and can be enlarged and enhanced to identify problems.

Source record↗

Fun Times with Cosmic Rays

Who would have thought cosmic rays could be so hip? Although discovered 90 years ago on death-defying manned balloon flights hip even by twenty-first-century extremesport standards cosmic rays quickly lost popularity as way-cool telescopes were finding way-too-cool phenomena across the electromagnetic spectrum. Yet cosmic rays are back in vogue, boasting their own set of superlatives. Scientists are tracking them down with new resolve from the Arctic to Antarctica and even on the high western plains of Argentina. Theorists, too, now see cosmic rays as harbingers of funky physics. Cosmic rays are atomic and subatomic particles - the fastest moving bits of matter in the universe and the only sample of matter we have from outside the solar system (with the exception of interstellar dust grains). Lower-energy cosmic rays come from the Sun. Mid-energy particles come from stellar explosions - either spewed directly from the star like shrapnel, or perhaps accelerated to nearly the speed of light by shock waves. The highest-energy cosmic rays, whose unequivocal existence remains one of astronomy's greatest mysteries, clock in at a staggering 10(exp 19) to 10(exp 22) electron volts. This is the energy carried in a baseball pitch; seeing as how there are as many atomic particles in a baseball as there are baseballs in the Moon, that s one powerful toss. No simple stellar explosion could produce them. At a recent conference in Albuquerque, scientists presented the first observational evidence of a possible origin for the highest-energy variety. A team led by Elihu Boldt at NASA s Goddard Space Flight Center found that five of these very rare cosmic rays (there are only a few dozen confirmed events) come from the direction of four 'retired' quasar host galaxies just above the arm of the Big Dipper, all visible with backyard telescopes: NGC 3610, NGC 3613, NGC 4589, and NGC 5322. These galaxies are billions of years past their glory days as the brightest beacons in the universe. Yet they still harbor central, supermassive black holes, which could generate energetic particles if they are spinning.

Wanjek, Christopher↗

Axial and appendicular bone density predict fractures in older women

To determine whether measurement of hip and spine bone mass by dual-energy x-ray absorptiometry (DEXA) predicts fractures in women and to compare the predictive value of DEXA with that of single-photon absorptiometry (SPA) of appendicular sites, we prospectively studied 8134 nonblack women age 65 years and older who had both DEXA and SPA measurements of bone mass. A total of 208 nonspine fractures, including 37 wrist fractures, occurred during the follow-up period, which averaged 0.7 years. The risk of fracture was inversely related to bone density at all measurement sites. After adjusting for age, the relative risks per decrease of 1 standard deviation in bone density for the occurrence of any fracture was 1.40 for measurement at the proximal femur (95% confidence interval 1.20-1.63) and 1.35 (1.15-1.58) for measurement at the spine. Results were similar for all regions of the proximal femur as well as SPA measurements at the calcaneus, distal radius, and proximal radius. None of these measurements was a significantly better predictor of fractures than the others. Furthermore, measurement of the distal radius was not a better predictor of wrist fracture (relative risk 1.64: 95% CI 1.13-2.37) than other sites, such as the lumbar spine (RR 1.56; CI 1.07-2.26), the femoral neck (RR 1.65; CI 1.12-2.41), or the calcaneus (RR 1.83; CI 1.26-2.64). We conclude that the inverse relationship between bone mass and risk of fracture in older women is similar for absorptiometric measurements made at the hip, spine, and appendicular sites.

Multicenter Study↗

Dynamic posture analysis of Spacelab-1 crew members

Dynamic posture testing was conducted on the science crew of the Spacelab-1 mission on a single axis linear motion platform. Tests took place in pre- and post-flight sessions lasting approximately 20 min each. The pre-flight tests were widely spaced over the several months prior to the mission while the post-flight tests were conducted over the first, second, fourth, and sixth days after landing. Two of the crew members were also tested on the day of landing. Consistent with previous postural testing conducted on flight crews, these crew members were able to complete simple postural tasks to an acceptable level even in the first few hours after landing. Our tests were designed to induce dynamic postural responses using a variety of stimuli and from these responses, evaluate subtle changes in the postural control system which had occurred over the duration of the flight. Periodic sampling post-flight allowed us to observe the time course of readaptation to terrestrial life. Our observations of hip and shoulder position, when subjected to careful analysis, indicated modification of the postural response from pre- to post-flight and that demonstrable adjustments in the dynamic control of their postural systems were taking place in the first few days after flight. For transient stimuli where the platform on which they were asked to stand quickly moved a few centimeters fore or aft then stopped, ballistic or open loop 'programs' would closely characterize the response. During these responses the desired target position was not always achieved and of equal importance not always properly corrected some 15 seconds after the platform ceased to move. The persistent observation was that the subjects had a much stronger dependence on visual stabilization post-flight than pre-flight. This was best illustrated by a slow or only partial recovery to an upward posture after a transient base-of-support movement with eyes open. Postural responses to persistent wideband pseudorandom base-of-support translation were modeled as time invarient linear systems arrived at by Kalman adaptive filter techniques. Derived model parameters such as damping factor and fundamental frequency of the closed loop system showed significant modification between pre- and post-flight. This phenomenon is best characterized by movement of the poles toward increasing stability. While pre-flight data tended to show shoulders and hips moving in phase with each other, post-flight data showed a more disjoint behavior.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Photoresponse Model for Si_(1-x)Ge_x/Si Heterojunction Internal Photoemission Infrared Detector

A photoresponse model has been developed for the Si_(1-x)Ge_x/Si heterojunction internalphotoemission (HIP) infrared detector at wavelengths corresponding to photon energies less than theFermi energy. A Si_(0.7)Ge_(0.3)/Si HIP detector with a cutoff wavelength of 23 micrometers andan emission coefficient of 0.4 eV^(-1) has been demonstrated. The model agrees with the measureddetector response at lambda greater than 8 micrometers. The potential barrier determined by themodel is in close agreement (difference similar to 4 meV) with the potential barrier determined by theRichardson plot, compared to the discrepancies of 20-50 meV usually observed for PtSi Schottkydetectors.

Lin, T.↗

Long-Wavelength Stacked SiGe/Si Heterojunction Internal Photoemission Infrared Detectors Using Multiple SiGe/Si Layers

Utilizing low temperature silicon molecular beam epitaxy (MBE) growth, long-wavelength stacked SiGe/Si heterojunction internal photoemission (HIP) infrared detectors with multiple SiGe/Si layers have been fabricated and demonstrated. Using an elemental boron source, high doping concentrations (approximately equal to 4 x 10(sup 20) cm(sup -3)) has been achieved and high crystalline quality multiple Si(sub 0.7)Ge(sub 0.3)/Si layers have been obtained. The detector structure consists of several periods of degenerately boron doped (approximately equal to 4 x 10(sup 20) cm(sup -3)) thin (less than or equal to 50 u Si(sub 0.7)Ge(sub 0.3) layers and undoped thick (approximately equal to 300u Si layers. The multiple p(sup +) - Si(sub 0.7)Ge(sub 0.3)/undoped-Si layers show strong infrared absorption in the long-wavelength regime mainly through free carrier absorption. The stacked Si(sub 0.7)Ge(sub 0.3)/Si HIP detectors with p = 4 x 10(sup 20) cm(sup -3) exhibit strong photoresponse at wavelengths ranging from 2 to 20 (micro)m with quantum efficiencies of about 4% and 1.5% at 10 and 15 (micro)m wavelengths, respectively. The detectors show near ideal thermionic-emission limited dark current characteristics.

beam epitaxy↗

Supine Treadmill Exercise in Lower Body Negative Pressure Combined with Resistive Exercise Counteracts Bone Loss, Reduced Aerobic Upright Exercise Capacity and Reduced Muscle Strength

Long-term exposure to weightlessness leads to cardiovascular and musculoskeletal deconditioning. In this report, the effectiveness of combined supine treadmill exercise in a lower body negative pressure chamber (LBNPex) and flywheel resistive exercise (Rex) countermeasures was determined to prevent bone loss, reduced aerobic upright exercise capacity and reduced muscle strength. We hypothesized that exercise subjects would show less decrease in bone mineral density (BMD), peak oxygen consumption (VO2pk) and knee extensor strength (KES) than control subjects. Sixteen healthy female subjects participated in a 60-d 6(sup 0) head-down tilt bed rest (BR) study after providing written informed consent. Subjects were assigned to one of two groups: a non-exercising control group CON or an exercise group EX performing LBNPex 2-4 d/wk and Rex every 3rd-d. VO2pk was measured with a maximal, graded, upright treadmill test performed pre-BR and on 3-d after BR. BMD was assessed before and 3-d after BR. Isokinetic KES was measured before and 5-d after BR. Two-way repeated measures ANOVA were performed. Statistical significance was set at p less than 0.05. CON experienced a significant decrease in BMD in the trochanter (PRE: 0.670 plus or minus 0.045; POST: 0.646 plus or minus 0.352 g (raised dot) per square centimeter) and in the whole hip (PRE=0.894 plus or minus 0.059; POST: 0.858 plus or minus 0.057 g (raised dot) per square centimeter). BMD also decreased significantly in EX in the trochanter (PRE: 0.753 plus or minus 0.0617; POST: 0.741 plus or minus 0.061 g (raised dot) per square centimeter) and whole hip (PRE: 0.954 plus or minus 0.067; POST: 0.935 plus or minus 0.069 g (raised dot) per square centimeter). BMD losses were significantly less in EX than in CON subjects. VO2pk was significantly decreased in the CON after BR (PRE: 38.0 plus or minus 4.8; POST: 29.9 plus or minus 4.2 ml (raised dot) per kilogram per minute), but not in the EX (PRE: 39.0 plus or minus 2.0; POST: 37.8 plus or minus 1.9 ml (raised dot) per kilogram per minute). KES was significantly reduced by 30% in Con (PRE: 113 plus or minus 12; POST: 78 plus or minus 8 N-m), but was not different in EX (PRE: 126 plus or minus 25; POST: 115 plus or minus 25 N-m). The combination LBNPex and Rex during 60-d BR protects against cardiovascular and musculoskeletal deconditioning and may be efficacious countermeasure for prolonged space flight.

Meuche, Sabine↗

WISE 2005: LBNP Exercise and Flywheel Resistive Exercise as an Effective Countermeasure Combination

Long-term exposure to microgravity can cause a severe musculoskeletal loss and cardiovascular deconditioning in astronauts. In this report, the effectiveness of combined supine treadmill exercise in a lower body negative pressure chamber (LBNPex) and flywheel resistive exercise (Rex) countermeasures was determined to prevent bone loss, reduced aerobic upright exercise capacity and reduced muscle strength. We hypothesized that exercise subjects (EX) would show less decrease in bone mineral density (BMD), peak oxygen consumption (VO2pk) and knee extensor strength (KES) than control subjects (CON). Sixteen healthy female subjects (34 plus or minus 4yrs, 164 plus or minus 6.5cm, 58 plus or minus 5kg; mean plus or minus SD) participated in a 60-d 6 degree head-down tilt bed rest (BR) study after providing written informed consent. Subjects were assigned to one of two groups: a non- exercising CON group or an EX group performing LBNPex 2-4 d/wk and Rex every 3rd-d. VO2pk was measured with a maximal, graded, upright treadmill test performed pre-BR and on 3-d after BR. BMD was assessed pre-BR and 3-d after BR by dual energy x-ray absorptiometry total body DEXA scan (DEXA; HOLOGIC QDR 4500 Elite ). A Cybex dynamometer was employed to measure the isokinetic KES before and 5-d after BR. Two-way repeated measures ANOVA were performed with time as the repeated factor. Statistical significance was set at p less than 0.05. CON experienced a significant decrease in BMD in the trochanter (PRE: 0.670 0.045; POST: 0.646 0.352 g(raised dot) per square centimeter) and in the whole hip (PRE: 0.894 0.059; POST: 0.858 0.057 g(raised dot) per square centimeter). BMD also decreased significantly in EX in the trochanter (PRE: 0.753 plus or minus 0.0617; POST: 0.741 plus or minus 0.061 g(raised dot) per square centimeter) and whole hip (PRE: 0.954 plus or minus 0.067; POST: 0.935 plus or minus 0.069 g(raised dot) per square centimeter). BMD losses were significantly less in EX than in CON subjects. VO2pk was significantly decreased in the CON after BR (PRE: 38.0 plus or minus 4.8; POST: 29.9 plus or minus 4.2 ml(raised dot) per kilogram per minute), but not in the EX (PRE: 39.0 plus or minus 2.0; POST: 37.8 plus or minus 1.9 ml(raised dot) per kilogram per minute). KES was significantly reduced by 30% in CON (PRE: 113 plus or minus 12; POST: 78 plus or minus 8 N-m), but was not different in EX (PRE: 126 plus or minus 25; POST: 115 plus or minus 25 N-m). The combination LBNPex and Rex during 60-d BR protects against cardiovascular and musculoskeletal deconditioning and may be an efficacious countermeasure for prolonged space flight.

Meuche, S.↗

Skeletal Adaptations to Different Levels of Eccentric Resistance Following Eight Weeks of Training

Coupled concentric-eccentric resistive exercise maintains bone mineral density (BMD) during bed rest and aging. PURPOSE: We hypothesized that 8 wks of lower body resistive exercise training with higher ratios of eccentric to concentric loading would enhance hip and lumbar BMD. METHODS: Forty untrained male volunteers (34.9+/-7.0 yrs, 80.9+/-9.8 kg, 178.2+/-7.1 cm; mean+/-SD) were matched for leg press (LP) 1-Repetition Maximum (1-RM) strength and randomly assigned to one of 5 training groups. Concentric load (% 1-RM) was constant across groups, but each group trained with different levels of eccentric load (0, 33, 66, 100, or 138% of concentric) for all training sessions. Subjects performed a periodized supine LP and heel raise (HR) training program 3 d wk-1 for 8 wks using a modified Agaton Fitness System (Agaton Fitness AB, Boden, Sweden). Hip and lumbar BMD (g/sq cm) was measured in triplicate pre- and post-training using DXA (Hologic Discovery ). Pre- and post-training means were compared using the appropriate ANOVA and Tukey's post hoc tests. Within group pre- to post-training BMD was compared using paired t-tests with a Bonferroni adjustment. RESULTS: There was a main effect of training on L1, L2, L3, L4, total lumbar, and greater trochanter BMD, but there were no differences between groups. CONCLUSION: Eights wks of lower body resistive exercise increased greater trochanter and lumbar BMD. Inability to detect group differences may have been influenced by a potentially osteogenic vibration associated with device operation in the 0, 33, and 66% groups.

English, Kirk L.↗

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.↗

Crashworthy Seats Would Afford Superior Protection

Seats to prevent or limit crash injuries to astronauts aboard the crew vehicle of the Orion spacecraft are undergoing development. The design of these seats incorporates and goes beyond crash-protection concepts embodied in prior spacecraft and racing-car seats to afford superior protection against impacts. Although the seats are designed to support astronauts in a recumbent, quasi-fetal posture that would likely not be suitable for non-spacecraft applications, parts of the design could be adapted to military and some civilian aircraft seats and to racing car seats to increase levels of protection. The main problem in designing any crashworthy seat is to provide full support of the occupant against anticipated crash and emergency-landing loads so as to safely limit motion, along any axis, of any part of the occupant s body relative to (1) any other part of the occupant s body, (2) the spacecraft or other vehicle, and (3) the seat itself. In the original Orion spacecraft application and in other applications that could easily be envisioned, the problem is complicated by severe limits on space available for the seat, a requirement to enable rapid egress by the occupant after a crash, and a requirement to provide for fitting of the seat to a wide range of sizes and shapes of a human body covered by a crash suit, space suit, or other protective garment. The problem is further complicated by other Orion-application-specific requirements that must be omitted here for the sake of brevity. To accommodate the wide range of crewmember body lengths within the limits on available space in the original Orion application, the design provides for taller crewmembers to pull their legs back closer toward their chests, while shorter crewmembers can allow their legs to stretch out further. The range of hip-support seat adjustments needed to effect this accommodation, as derived from NASA s Human Systems Integration Standard, was found to define a parabolic path along which the knees must be positioned. For a given occupant, the specific position along the path depends on the distance from the heel to the back of the knee. The application of the concept of parabolic adjustment of the hip-support structure caused the seat pan to also take on a parabolic shape, yielding the unanticipated additional benefit that the seat pan fits the occupant s buttocks and thighs more nearly conformally than do seat pans of prior design. This more nearly conformal fit effectively eliminates a void between the occupant s body and the seat pan, thereby helping to prevent what, in prior seat designs, was shifting of the occupant s body into that void during an impact.

Gohmert, Dustin↗

The Role of Adaptation in Body Load-Regulating Mechanisms During Locomotion

Body loading is a fundamental parameter that modulates motor output during locomotion, and is especially important for controlling the generation of stepping patterns, dynamic balance, and termination of locomotion. Load receptors that regulate and control posture and stance in locomotion include the Golgi tendon organs and muscle spindles at the hip, knee, and ankle joints, and the Ruffini endings and the Pacinian corpuscles in the soles of the feet. Increased body weight support (BWS) during locomotion results in an immediate reorganization of locomotor control, such as a reduction in stance and double support duration and decreased hip, ankle, and knee angles during the gait cycle. Previous studies on the effect during exposure to increased BWS while walking showed a reduction in lower limb joint angles and gait cycle timing that represents a reorganization of locomotor control. Until now, no studies have investigated how locomotor control responds after a period of exposure to adaptive modification in the body load sensing system. The goal of this research was to determine the adaptive properties of body load-regulating mechanisms in locomotor control during locomotion. We hypothesized that body load-regulating mechanisms contribute to locomotor control, and adaptive changes in these load-regulating mechanisms require reorganization to maintain forward locomotion. Head-torso coordination, lower limb movement patterns, and gait cycle timing were evaluated before and after a 30-minute adaptation session during which subjects walked on a treadmill at 5.4 km/hr with 40% body weight support (BWS). Before and after the adaptation period, head-torso and lower limb 3D kinematic data were obtained while performing a goal directed task during locomotion with 0% BWS using a video-based motion analysis system, and gait cycle timing parameters were collected by foot switches positioned under the heel and toe of the subjects shoes. Subjects showed adaptive modification in the body load-regulating mechanisms that included increased head movement amplitude, increased knee and ankle flexion, and increased stance, stride, and double support time, with no change in the performance of the task with respect to that measured before exposure to BWS. These changes in locomotor control are opposite to that reported during 40% BWS exposure and indicative of an after-effect after removal of the adaptive stimulus. Therefore, it is evident that just 30 minutes of 40% BWS during locomotion was sufficient to induce adaptive modifications in the body load sensing systems that contribute to reorganization of sensory contributions to stable locomotor control.

Ruttley, Tara↗

Development of a Ground-Based Analog to the Advanced Resistive Exercise Device Aboard the International Space Station

NASA and Wyle engineers constructed a Horizontal Exercise Fixture (HEF) that was patented in 2006. Recently modifications were made to HEF with the goal of creating a device that mimics squat exercise on the Advanced Resistive Exercise Device (ARED) and can be used by bed rest subjects who must remain supine during exercise. This project posed several engineering challenges, such as how best to reproduce the hip motions (we used a sled that allowed hip motion in the sagittal plane), how to counterweight the pelvis against gravity (we used a pulley and free-weight mechanism), and how to apply large loads (body weight plus squat load) to the shoulders while simultaneously supporting the back against gravity (we tested a standard and a safety bar that allowed movement in the subject s z-axis, both of which used a retractable plate for back support). METHODS An evaluation of the HEF was conducted with human subjects (3F, 3M), who performed sets of squat exercises of increasing load from 10-repetition maximum (RM) up to 1-RM. Three pelvic counterweight loads were tested along with each of the two back-support squat bars. Data collection included 3-dimensional ground reaction forces (GRF), muscle activation (EMG), body motion (video-based motion capture), and subjective comments. These data were compared with previous ground-based ARED study data. RESULTS All subjects in the evaluation were able to perform low- to high-loading squats on the HEF. Four of the 6 subjects preferred a pelvic counterweight equivalent to 60 percent of their body weight. Four subjects preferred the standard squat bar, whereas 2 female subjects preferred the safety bar. EMG data showed muscle activation in the legs and low back typical of squat motion. GRF trajectories and eccentric-concentric loading ratios were similar to ARED. CONCLUSION: Squat exercise performed on HEF approximated squat exercise on ARED.

Newby, Nathaniel J.↗