Search NASA⌕ Search

SEARCH · Search NASA

Results for “HOLOGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Hubble Space Telescope COSTAR asphere verification with a modified computer-generated hologram interferometer

To correct for the spherical aberration in the Hubble Space Telescope primary mirror, five anamorphic aspheric mirrors representing correction for three scientific instruments have been fabricated as part of the development of the corrective-optics space telescope axial-replacement instrument (COSTAR). During the acceptance tests of these mirrors at the vendor, a quick and simple method for verifying the asphere surface figure was developed. The technique has been used on three of the aspheres relating to the three instrument prescriptions. Results indicate that the three aspheres are correct to the limited accuracy expected of this test.

Feinberg, L.↗

High-Density, High-Bandwidth, Multilevel Holographic Memory

A proposed holographic memory system would be capable of storing data at unprecedentedly high density, and its data transfer performance in both reading and writing would be characterized by exceptionally high bandwidth. The capabilities of the proposed system would greatly exceed even those of a state-of-the art memory system, based on binary holograms (in which each pixel value represents 0 or 1), that can hold .1 terabyte of data and can support a reading or writing rate as high as 1 Gb/s. The storage capacity of the state-of-theart system cannot be increased without also increasing the volume and mass of the system. However, in principle, the storage capacity could be increased greatly, without significantly increasing the volume and mass, if multilevel holograms were used instead of binary holograms. For example, a 3-bit (8-level) hologram could store 8 terabytes, or an 8-bit (256-level) hologram could store 256 terabytes, in a system having little or no more size and mass than does the state-of-the-art 1-terabyte binary holographic memory. The proposed system would utilize multilevel holograms. The system would include lasers, imaging lenses and other beam-forming optics, a block photorefractive crystal wherein the holograms would be formed, and two multilevel spatial light modulators in the form of commercially available deformable-mirror-device spatial light modulators (DMDSLMs) made for use in high speed input conversion of data up to 12 bits. For readout, the system would also include two arrays of complementary metal oxide/semiconductor (CMOS) photodetectors matching the spatial light modulators. The system would further include a reference-beam sterring device (equivalent of a scanning mirror), containing no sliding parts, that could be either a liquid-crystal phased-array device or a microscopic mirror actuated by a high-speed microelectromechanical system. Time-multiplexing and the multilevel nature of the DMDSLM would be exploited to enable writing and reading of multilevel holograms. The DMDSLM would also enable transfer of data at a rate of 7.6 Gb/s or perhaps somewhat higher.

Chao, Tien-Hsin↗

Holographic wavefront sensors

A brief historical review of the first designs of holographic wavefront sensors (WFS’s) and the concepts lying in their basis is presented. The main directions in the development of these sensors are highlighted and considered. One of these directions implies a two-stage transition from the use of several separate measuring channels with holograms filtering only one Zernike mode: first to the use of one channel with a multiplexed hologram filtering several first Zernike modes, and then to filtering the entire set of Zernike modes with the aid of one combined multiplexed hologram. Another line of research in this field (related to the first one) is the optimisation of the filter hologram structure in order to reduce cross-modulation interferences, increase multiplexing level, etc. One more line of research implements principles of dynamic holography by introducing spatial light modulators into the WFS composition. Hence, the advantages of time multiplexing of holograms can be used. The approach developed by G. Andersen’s team, aimed at adapting the holographic WFS design for operation as an element of adaptive optical system with a zonal corrector, as well as an approach implying development of hybrid holographic sensors, are considered separately. The results of the authors’ studies of holographic WFS’s with application of the methods of Fourier holography (i.e., holography of focused beams, in particular, using diffuse scatterers in a hologram recording channel) are also reported. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle field holography data reduction by Fourier transform analysis

The size distribution of a particle field hologram is obtained with a Fourier transformation of the Fraunhofer diffraction pattern of the reconstructed hologram. Off-axis absorption holograms of particle fields with known characteristics were obtained and analyzed with a commercially available instrument. The mean particle size of the reconstructed hologram was measured with an error of + or - 5 percent, while the distribution broadening was estimated within + or - 15 percent. Small sections of a pulsed laser hologram of a synthetic fuel spray were analyzed with this method thus yielding a spatially resolved size distribution. The method yields fast and accurate automated analysis of particle field holograms.

Hess, Cecil F.↗

A study of TRIGLYCINE SULFATE (TGS) crystals from the International Microgravity Laboratory Mission (IML-1)

Preliminary evaluation of the data was made during the hologram processing procedure. A few representative holograms were selected and reconstructed in the HGS; photographs of sample particle images were made to illustrate the resolution of all three particle sizes. Based on these evaluations slight modifications were requested in the hologram processing procedure to optimize the hologram exposure in the vicinity of the crystal. Preliminary looks at the data showed that we are able to see and track all three sizes of particles throughout the chamber. Because of the vast amount of data available in the holograms, it was recommended that we produce a detailed data reduction plan with prioritization on the different types of data which can be extracted from the holograms.

Lal, R. B.↗

Sandia Particle Holography Processor v. 1.0

HoloSand is a suite of MATLAB® functions for measurement of particle properties from digital holograms. Functions to read and display digital holograms are included along with scripts to extract three-dimensional particle positions, sizes, and velocities. This software is a research tool used to process experimental data. A user of this software would first record digital holograms of a particle field and then use this software to measure the three-dimensional particle information encoded in the hologram. Applications range from basic laboratory fluids research to applied particle measurements. The software has no known military applications. The software solves the diffraction integral equation to numerically refocus digital holograms and then applies the hybrid and cross-correlation methods described in the references to extract three-dimensional particle information. User input is required to read-in the hologram and select optimum settings for image segmentation.

Guildenbecher, Daniel↗

Angular Selectivity of Amplitude-Phase Holographic Gratings in Polymer Material with Phenanthrenequinone

The values of the amplitudes of the refractive index and absorption coefficient modulations in volume hologram gratings, which were recorded in a polymer material with phenanthrenequinone (PQ), have been determined by the results of the approximation of the angular selectivity contours, which were measured at wavelengths of 450, 473, 532, and 633 nm before and after the development of holograms, resulting from the diffusion of PQ molecules in a glassy polymer. Immediately after recording, before the diffusion development, the holograms are mixed amplitude-phase in the PQ absorption spectral region and phase for the red light, which is not absorbed by it (633 nm), and become purely phase during the development regardless of the wavelength. The shape of the selectivity contour of the undeveloped hologram indicates the counterphase between the modulations of the absorption coefficient and refractive index, illustrating the concept of complementary gratings, on which the principle of hologram formation in the material under consideration is based.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of Entrainment on Centimeter-Scale Cloud Microphysics in Marine Stratocumulus Clouds Observed during CSET

Abstract Cloud microphysical relationships observed during the Cloud System Evolution in the Trades (CSET) campaign held between Northern California and Hawaii were analyzed to study the effects of entrainment and subsequent mixing of free-tropospheric and cloudy air on cloud microphysical properties of marine stratocumulus clouds. The data measured by Holographic Detector for Clouds (HOLODEC) were extensively used because they could provide the 3D positions and sizes of droplets within sample volume on the centimeter scale, making it possible to explore the 3D spatial distribution of droplets, which has not been possible for conventional cloud probes. This study focused on analyzing the 3D spatial distribution of droplets and visual traits of inhomogeneous mixing and on quantifying the relationship between 3D spatial distributions and traits of inhomogeneous mixing. Two types of spatial distributions are compared. The first is measured droplet spatial distribution and the second type is generated randomly distributed droplets using the Monte Carlo approach, that is, to analyze whether or not clustering is strong enough to classify as a clustered distribution for a hologram. The difference between the two types of spatial distributions depends on whether they are affected by entrainment and mixing. The holograms observed near the cloud top, where the effects of entrainment and mixing would be immediate, showed relatively high confidence in the significance test for spatially clustered populations of droplets. Moreover, spatially clustered holograms appeared to exhibit stronger visual traits of inhomogeneous mixing than perfectly randomly distributed holograms only when observed near the cloud top. On the other hand, these characteristics did not appear for holograms observed deeper into the cloud where the effects of entrainment and mixing would be reduced. Such 3D structural characteristics of droplet distributions seem to be consistent with vertical circulation mixing.

Meteorology & Atmospheric Sciences↗

LCTV Holographic Imaging

Astronauts are required to interface with complex systems that require sophisticated displays to communicate effectively. Lightweight, head-mounted real-time displays that present holographic images for comfortable viewing may be the ideal solution. We describe an implementation of a liquid crystal television (LCTV) as a spatial light modulator (SLM) for the display of holograms. The implementation required the solution of a complex set of problems. These include field calculations, determination of the LCTV-SLM complex transmittance characteristics and a precise knowledge of the signal mapping between the LCTV and frame grabbing board that controls it. Realizing the hologram is further complicated by the coupling that occurs between the phase and amplitude in the LCTV transmittance. A single drive signal (a gray level signal from a framegrabber) determines both amplitude and phase. Since they are not independently controllable (as is true in the ideal SLM) one must deal with the problem of optimizing (in some sense) the hologram based on this constraint. Solutions for the above problems have been found. An algorithm has been for field calculations that uses an efficient outer product formulation. Juday's MEDOF 7 (Minimum Euclidean Distance Optimal Filter) algorithm used for originally for filter calculations has been successfully adapted to handle metrics appropriate for holography. This has solved the problem of optimizing the hologram to the constraints imposed by coupling. Two laboratory methods have been developed for determining an accurate mapping of framegrabber pixels to LCTV pixels. A friendly software system has been developed that integrates the hologram calculation and realization process using a simple set of instructions. The computer code and all the laboratory measurement techniques determining SLM parameters have been proven with the production of a high quality test image.

Knopp, Jerome↗

Optical Verification Laboratory Demonstration System for High Security Identification Cards

Document fraud including unauthorized duplication of identification cards and credit cards is a serious problem facing the government, banks, businesses, and consumers. In addition, counterfeit products such as computer chips, and compact discs, are arriving on our shores in great numbers. With the rapid advances in computers, CCD technology, image processing hardware and software, printers, scanners, and copiers, it is becoming increasingly easy to reproduce pictures, logos, symbols, paper currency, or patterns. These problems have stimulated an interest in research, development and publications in security technology. Some ID cards, credit cards and passports currently use holograms as a security measure to thwart copying. The holograms are inspected by the human eye. In theory, the hologram cannot be reproduced by an unauthorized person using commercially-available optical components; in practice, however, technology has advanced to the point where the holographic image can be acquired from a credit card-photographed or captured with by a CCD camera-and a new hologram synthesized using commercially-available optical components or hologram-producing equipment. Therefore, a pattern that can be read by a conventional light source and a CCD camera can be reproduced. An optical security and anti-copying device that provides significant security improvements over existing security technology was demonstrated. The system can be applied for security verification of credit cards, passports, and other IDs so that they cannot easily be reproduced. We have used a new scheme of complex phase/amplitude patterns that cannot be seen and cannot be copied by an intensity-sensitive detector such as a CCD camera. A random phase mask is bonded to a primary identification pattern which could also be phase encoded. The pattern could be a fingerprint, a picture of a face, or a signature. The proposed optical processing device is designed to identify both the random phase mask and the primary pattern [1-3]. We have demonstrated experimentally an optical processor for security verification of objects, products, and persons. This demonstration is very important to encourage industries to consider the proposed system for research and development.

Javidi, Bahram↗

Systematic Design and Experimental Demonstration of Transmission-Type Multiplexed Acoustic Metaholograms

Acoustic holograms have promising applications in sound-field reconstruction, particle manipulation, ultrasonic haptics, and therapy. This study reports on the theoretical, numerical, and experimental investigation of multiplexed acoustic holograms at both audio and ultrasonic frequencies via a rationally designed transmission-type acoustic metamaterial. The proposed metahologram is composed of two Fabry–Pérot resonant channels per unit cell, which enables the simultaneous modulation of the transmitted amplitude and phase at two desired frequencies. In contrast to conventional acoustic metamaterial-based holograms, the design strategy proposed here provides a new degree of freedom (frequency) that can actively tailor holograms that are otherwise completely passive and significantly enhances the information encoded in acoustic metamaterials. To demonstrate the multiplexed acoustic metamaterial, the projection of two different high-quality metaholograms is first shown at 14 and 17 kHz, with the patterns of the letters N and S. Then, two-channel ultrasound focusing and annular beams generation for the incident ultrasonic frequencies of 35 and 42.5 kHz are demonstrated. Furthermore, these multiplexed acoustic metaholograms offer a technical advance to tackle the rising challenges in the fields of acoustic metamaterials, architectural acoustics, and medical ultrasound.

36 MATERIALS SCIENCE↗

Enhanced nearfield acoustic holography for larger distances of reconstructions using fixed parameter Tikhonov regularization

This paper evaluates the performance of various regularization parameter choice methods applied to different approaches of nearfield acoustic holography when a very nearfield measurement is not possible. For a fixed grid resolution, the larger the hologram distance, the larger the error in the naive nearfield acoustic holography reconstructions. These errors can be smoothed out by using an appropriate order of regularization. In conclusion, this study shows that by using a fixed/manual choice of regularization parameter, instead of automated parameter choice methods, reasonably accurate reconstructions can be obtained even when the hologram distance is 16 times larger than the grid resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of holography to flow visualization within rotating compressor blade row

Two holographic interblade row flow visualization systems were designed to determine the three-dimensional shock patterns and velocity distributions within the rotating blade row of a transonic fan rotor, utilizing the techniques of pulsed laser transmission holography. Both single- and double-exposure bright field holograms and dark field scattered-light holograms were successfully recorded. Two plastic windows were installed in the rotor tip casing and outer casing forward of the rotor to view the rotor blade passage. The viewing angle allowed detailed investigation of the leading edge shocks and shocks in the midspan damper area; limited details of the trailing edge shocks also were visible. A technique was devised for interpreting the reconstructed holograms by constructing three dimensional models that allowed identification of the major shock systems. The models compared favorably with theoretical predictions and results of the overall and blade element data. Most of the holograms were made using the rapid double-pulse technique.

Wuerker, R. F.↗

Holographic flow visualization within a rotating compressor blade row

Rapid double-pulsed holographic techniques were used to visualize the shock configurations in the tip region of a lightly loaded, high tip speed fan stage. The holograms showed the passage shock emanating from the blade leading edge, a moderately strong conical shock originating at the intersection of the part span shroud leading edge and the blade suction surface, and a second conical shock originating at the intersection of the part span shroud and the blade pressure surface. Due to a limited viewing angle, the bow waves upstream of the rotor could not be observed, and only limited details of the trailing edge shocks were obtained. Reasonable details of the shock patterns were obtained from holograms which were made without extensive rig modifications. Results indicate that larger viewing windows and and holographic plates would permit a wider viewing angle and give much more coverage of the regions of interest. Also, shorter time delay for double-pulsed holograms is also desirable, and would minimize blade movement and give clearer holograms.

Benser, W. A.↗

A comparison of digitally simulated holographic images with actual holographic images

In making digitally generated holograms the digital computer and its associated plotting equipment degrade the quality of the hologram. It is necessary then to study the computer generated hologram in terms of these degradations. A computer simulated optical processor allows the results to be observed via computer simulated images. This research reports a method for optimizing the computer image reconstruction and compares these images with optically produced holographic images. The versatility of the simulated optical processor is illustrated by several spatial filtering and hologram reconstructions.

Calhoun, M. D.↗