Search NASA⌕ Search

SEARCH · Search NASA

Results for “HTF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Concurrent Optimization of Capital Cost and Expected O&M

Concentrating solar power (CSP) technologies can utilize heat from concentrated sunlight from a field of tracking mirrors to generate electricity, reform fuel, provide process heat, or augment fossil plant heat sources. Electricity-generating power tower systems focus light from thousands of independent heliostats onto a thermal receiver, which uses the focused light to warm a heat transfer fluid (HTF), typically, a molten nitrate salt. The HTF is then sent to a power generation cycle or diverted into thermal energy storage (TES) for later use. Thermal storage is – in principle – a straightforward proposition. However, optimal utilization of a TES resource is complex and multi-faceted: thermal energy may be dispatched to produce electricity immediately upon first availability, or thermal energy may be reserved for next-day peak periods at risk of filling storage and dumping energy, or a portion of the thermal energy can be reserved to maintain equipment temperatures, reducing power cycle startup time, etc. Many possible dispatch permutations variously emphasize producing peak power, operating through transients, expediting daily startup, etc. The best operation strategy can change day-to-day throughout the year, depending on the weather and market pricing forecasts. The project we describe in this report develops a software package that allows users to explore design optimization, operations decisions, and performance characterization of concentrating solar power tower plants. Users interface with the tool through a scripting language, and results are reported in time series tables, plots, runtime logs, and design outputs. Users choose from a list of variables such as tower height, solar multiple, design-point irradiance, thermal storage size, etc., and specify information about the system using a list of parameters. The software can then optimize the specified variables to reduce the cost of energy produced by the system while meeting certain production requirements, accounting for uncertain weather and electricity price forecasts, and correcting for equipment failures or repair time. The software we develop is the first comprehensive design tool of its kind to incorporate all of these aspects while being deployed as open source.

14 SOLAR ENERGY↗

Characterization of the SRNL-Washed Tank 51 Sludge Batch 10 Qualification Sample

Savannah River National Laboratory (SRNL) personnel have been requested to qualify the next sludge batch (Sludge Batch 10 – SB10) for processing at the Defense Waste Processing Facility (DWPF). To accomplish this task, Savannah River Remediation (SRR) sent SRNL two 3-L samples of Tank 51H slurry to be characterized, washed, and then used in a lab-scale demonstration of the DWPF flowsheet. Sample HTF-51-19-114 was received on January 28, 2020, and HTF-51-20-15 was received on February 4, 2020. SRNL washed the Tank 51H sample per the Tank Farm washing strategy. During washing, material from H Canyon Tanks 16.3 and 16.4 was also added to the Tank 51 samples to simulate canyon discharges subsequent to sampling. A part of the qualification process is extensive radionuclide and chemical characterization of the SRNL-washed Tank 51H slurry. This report documents the chemical characterization of the washed slurry; radiological characterization will be documented in a separate report. The major supernatant components, elements on a weight percent calcined basis, and the weight percent solids of the SRNL-washed sample were comparable to the Tank Farm projections, with the exception of free hydroxide and carbonate. Therefore, this SRNL-washed sample is suitable for further SB10 qualification activities and SRR planning for SB10.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas Turbine/Solar Parabolic Trough Hybrid Design Using Molten Salt Heat Transfer Fluid: Preprint

Parabolic trough power plants can provide reliable power by incorporating either thermal energy storage (TES) or backup heat from fossil fuels. This paper describes a gas turbine / parabolic trough hybrid design that combines a solar contribution greater than 50% with gas heat rates that rival those of natural gas combined-cycle plants. Previous work illustrated benefits of integrating gasturbines with conventional oil heat-transfer-fluid (HTF) troughs running at 390?C. This work extends that analysis to examine the integration of gas turbines with salt-HTF troughs running at 450 degrees C and including TES. Using gas turbine waste heat to supplement the TES system provides greater operating flexibility while enhancing the efficiency of gas utilization. The analysis indicatesthat the hybrid plant design produces solar-derived electricity and gas-derived electricity at lower cost than either system operating alone.

14 SOLAR ENERGY↗

Hybrid Solar Heat Generation Modelling and Cases: Preprint

Renewable thermal energy systems (RTES) harness renewable energy sources to provide services for space heating and cooling, district heating, domestic hot water, and industrial process heat (IPH). The use of low-pressure steam generated by the combustion of fossil fuels is common today to provide process heat for industrial facilities. Solar IPH (SIPH) technologies could economically replace the steam or heat needs at many industrial sites by providing high-temperature pressurized hot water, a heat transfer fluid (HTF) such as synthetic-oil, or direct steam (Kurup and Turchi, 2015). RTES could be hybridized with technology options or combined with the existing heat supply (e.g. fuels), to give options for targeted IPH application and the reduction of fuel consumption. This work has tested hybrid system modelling approaches. Initial results show when a natural gas (NG) burner that feeds an IPH application of 300°C, has both air and NG streams pre-heated with a solar field/RTES exit temperature of 180°C (via an HTF), a 13% NG offset is possible. NG offsets reach up to 26%, when the RTES exit temperatures are at 300°C for a given annual capacity factor of 24%. This can be even higher with addition of thermal energy storage (TES).

43 PARTICLE ACCELERATORS↗

Hypersonic test facility using nitrous oxide

A high enthalpy and low-cost Hypersonic Test Facility (HTF), which employs nitrous oxide to generate clean air-like gas; and a method of decomposing nitrous oxide in the presence of a catalyst in a catalytic decomposition chamber in a HTF.

Pourpoint, Timothee L.↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

TEX 2.0: DOE-EM NCS Experimental Needs [Slides]

This presentation touches on the needs presented from recent work with Hanford Tank Farms (HTF) and Savannah River Site (SRS) Liquid Waste Process (LWP). The Meetings were held with other sites by presenting information about TEX 2.0 and having discussions on what the current challenges were for criticality safety validation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Premelting, Melting, and Degradation Properties of Molten Alkali Nitrates: LiNO{sub 3}, NaNO{sub 3}, KNO{sub 3}, and Binary NaNO{sub 3}-KNO{sub 3}

A simultaneous thermal analyzer (STA) was used to observe the transition and degradation events of LiNO{sub 3}, NaNO{sub 3}, KNO{sub 3}, and binary NaNO{sub 3}-KNO{sub 3} salts for potential use as phase change materials (PCMs) and heat transfer fluid (HTF). Samples were heated from 50 °C to 800 °C at 10 °C/min scanning rate in three atmospheres (argon, air, and oxygen) using an STA to observe decomposition behavior. Thermal stability increased for all salts at high partial pressure of O{sub 2} (P{sub O{sub 2}}= 1.0) compared to inert argon (P{sub O{sub 2}}= 0). O{sub 2}, N{sub 2}, NO, N{sub 2}O, and NO{sub 2} were main evolved gases during nitrate decomposition. NO and O{sub 2} started to evolve at approximately the same temperature after melting, indicating that primary and secondary decomposition reactions were concurrent and overlapping. The solid-solid transition, liquidus and solidus temperatures, heat of transition, heat of melting, and heat of solidification were obtained at various heating-cooling rates (1, 2, 4, 5, 6, 8, 10, and 15 °C/min) using an STA. At all heating-cooling rates, a small gap exists between liquidus and solidus temperatures for all samples due to the salts exhibiting supercooling phenomena. This study showed that the degradation point depends on the blanket atmosphere top of the molten salts and that heating rates have a minor effect on transition events (peaks height, peaks width, and transition enthalpies).

36 MATERIALS SCIENCE↗

Heat transfer model for moving packed-bed particle-to-sCO 2 heat exchangers integrated with metal foams

Particle-to-supercritical carbon dioxide (sCO 2 ) heat exchangers (HXs) play a vital role in coupling heat transfer fluid (HTF) from high-temperature thermal receivers to power cycle working fluids (WF). Heat transfer enhancement is essential for adopting particle-based moving packed-bed heat exchangers (MPBHXs) in next-generation thermal energy storage (TES) systems, as MPBHXs usually exhibit low particle bed-to-wall heat transfer coefficients. High-porosity metal foams have shown their effectiveness in heat transfer enhancement. Here, this work presents a continuum heat transfer model to demonstrate the heat transfer enhancement in MPBHXs when the particle bed channel is filled with high porosity metal foams compared to open channel MPBHXs. The presence of metal foams increases the effective thermal conductivity in the particle channel and enhances the interstitial heat transfer coefficient between the moving particle bed and the stationary metal foams. The present model considers coupled two-dimensional (2D) heat transfer in the particle channel with metal foams and 1D heat transfer in the sCO 2 channel and the dividing wall. The temperature profiles for the particle bed, metal foam, dividing wall, and sCO 2 stream, as well as the local heat flux profiles between those, are studied in detail for various foam porosities, from which the particle bed-to-wall heat transfer coefficient, overall heat transfer coefficient, and total heat transfer rate for the MPBHX are determined. The effects of major MPBHX design and operating parameters on the particle bed-to-wall heat transfer coefficient and overall heat exchange capacity are thoroughly examined; thus, the MPBHX performance improvement with metal foams is quantified for each case. The present heat transfer model can provide valuable insights into the metal-foam MPBHX design and optimization, scale-up, and operating parameters selection.

42 ENGINEERING↗

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗

Development of a concentrating solar power system using fluidized-bed technology for thermal energy conversion and solid particles for thermal energy storage

Concentrating solar power (CSP) is an effective way to convert solar energy into electricity with an economic energy-storage capability for grid-scale, dispatchable renewable power generation. However, CSP plants need to reduce costs to be competitive with other power generation methods. Two ways to reduce CSP cost are to increase solar-to-electric efficiency by supporting a high-efficiency power conversion system, and to use low-cost materials in the system. The current nitrate-based molten-salt systems have limited potential for cost reduction and improved power-conversion efficiency with high operating temperatures. Even with significant improvements in operating performance, these systems face challenges in satisfying the cost and performance targets. This paper introduces a novel CSP system with high-temperature capability that can be integrated into a high-efficiency CSP plant and that meets the low-cost, high-performance CSP targets. Unlike a conventional salt-based CSP plant, this design uses gas/solid, two-phase flow as the heat-transfer fluid (HTF); separated solid particles as storage media; and stable, inexpensive materials for the high-temperature receiver and energy storage containment. We highlight the economic and performance benefits of this innovative CSP system design, which has thermal energy storage capability for base-load power generation.

14 SOLAR ENERGY↗

A fast reduced model for a shell-and-tube based latent heat thermal energy storage heat exchanger and its application for cost optimal design by nonlinear programming

Numerical simulation of latent heat thermal energy storage (LHTES) systems plays a fundamental role in studying the physical process and guiding the engineering design. Discretization of the PDEs describing the nonlinear solidification/melting process of phase change materials (PCMs) leads to a large-scale complex dynamics system, where the system behavior depends on a set of parameters. In a design setting, repeated model evaluations are required over the set of parameters results in significant computational burden. In this paper, an explicit analytic solution was built for the propagation of the solidification front in a cylindrical coordinate. The analytic solution approach is further employed to develop a low computational reduced model (RM) as a module for a shell-and-tube based LHTES heat exchanger. The levelized Cost of Energy (LCOE) is used as a design metric and the RM model is used to apply system-level constraints in the nonlinear programming formulation that facilitates efficient global optimal design of the PCM properties, flow conditions and tube geometries. The use of LCOE as the design metric prevents over design of the heat transfer rate and also establishes a fair ground for evaluation of different thermal storage technologies and their integrated applications with other systems. Optimal results showed that a higher effectiveness results in a higher LCOE; the velocity of the HTF and the length of the channel are highly correlated with each other; both larger PCM latent energy and conductivity result in lower LCOE.

25 ENERGY STORAGE↗

Multielectrode Array Sensors to Enable Long-Duration Corrosion Monitoring and Control of Concentrating Solar Power Systems

Molten mixtures of MgCl2-KCl-NaCl are promising heat transfer fluid (HTF) candidates for the next generation of concentrating solar power systems (Gen3 CSP), because of their low cost, high decomposition temperature, and favorable heat transfer characteristics. However, if the chemistry of the salts is not properly controlled, molten chlorides can cause corrosion of high-temperature metal alloys, such as Inconel (R), in CSP systems. Here we demonstrate a corrosion monitoring system that can be used to monitor the health of the structural alloys over long durations. The monitoring system includes a multielectrode array voltammetry sensor that measures the redox potential of molten MgCl2-KCl-NaCl mixture as well as the presence of corrosion products and impurities. The sensors have been successfully operated in static molten salt environments for long durations, and are capable of detecting corrosion products, such as Cr2+ and Fe2+, quantitatively at low concentrations (i.e., approximately 100 ppm) with less than 4% error.

Concentrated solar power↗

Single crystalline multi-petal Cd nanoleaves prepared by thermal reduction of CdO

Highlights: ► Cd nanoleaves are obtained on abraded Cu substrate by thermal reduction of CdO. ► Vapour solid (VS) growth mechanism governs the formation of Cd nanoleaves (CdNLs). ► PL spectrum for CdNLs exhibits a strong ultraviolet (UV) emission band at 353 nm. ► UV band is attributed to interband radiative recombination under Xe illumination. -- Abstract: Multi-petal cadmium metal nanoleaves with 30–40 nm thickness were fabricated on abraded copper substrate by simple thermal reduction of cadmium oxide (CdO) powder at 1050 °C inside horizontal tube furnace (HTF) under nitrogen gas flow. The structural, compositional and morphological characterizations of the as-prepared cadmium nanoleaves (CdNLs) were performed by X-ray diffraction, energy dispersive X-ray spectroscopy, scanning electron microscopy, high resolution transmission electron microscopy and selected area electron diffraction. Non-catalytic vapour–solid (VS) process based growth mechanism governing the formation of CdNLs has been proposed and discussed briefly. Photoluminescence (PL) spectrum for CdNLs measured at room temperature exhibited a single prominent emission band at 353 nm which may either be ascribed to surface oxidation effects or interband radiative recombination under Xe light illumination.

36 MATERIALS SCIENCE↗

Influence of the concentration ratio on the thermal and economic performance of parabolic trough collectors

The thermal and economic performance of parabolic trough collectors (PTCs) and PTCs with double glass envelope (DGE-PTCs) are analyzed in this work. A model including thermal and optical effects is developed to evaluate the efficiency of vacuum and air-filled DGE-PTCs, while an economic model based on two commercial PTCs (SkyTrough and Ultimate Trough collectors) was developed to assess the economic performance. The efficiency and thermal output per unit cost of the proposed DGE-PTCs are analyzed as a function of the concentration ratio and are respectively compared with the thermal and economic performance of traditional and commercial PTCs. The optimum concentration ratio for maximum thermal performance varies from 11.0 to 23.3 for operation temperatures (T HTF ) between 100 degrees C and 400 degrees C, while the optimum concentration ratio for maximum economic performance ranges between 28.9 and 33.2 for the SkyTrough and between 40.0 and 43.8 for the Ultimate Trough collector designs. Finally, the DGE-PTCs present higher thermal and economic performance at high operating temperatures, which presents a valuable opportunity for implementation in new PTC designs pursuing higher operating temperatures to achieve superior thermal cycle efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of external tubular configurations for a high-temperature chloride molten salt solar receiver operating above 700°C

Next-generation concentrating solar power (CSP) tower technologies target operating temperatures exceeding 700°C to increase the thermal-to-electric conversion efficiency. Molten chloride salts are one possible alternative to current commercial molten nitrate salts to enable the higher operating temperature. This paper analyzes the predicted optical, thermal-fluids, and structural performance of traditional external tubular solar receiver configurations applied with a chloride salt heat transfer fluid (HTF) and inlet/outlet temperatures of 500°C/735°C, and considers sensitivity analysis and optimization relative to receiver sizing, tube sizing, number of panels, flow circuit configurations, and solar flux concentration under constraints on internal velocity, pressure drop, wall thickness, and required creep-fatigue lifetime. The high temperature conditions increase the significance of inelastic deformation mechanisms such as creep relative to that expected in commercial 565°C nitrate salt designs. High-temperature creep and creep-fatigue damage in the metal alloy tubes are the key factors that limit allowable solar flux concentration and achievable receiver thermal efficiency at the near-800°C wall temperature conditions. For a traditional external cylindrical receiver configuration, the design parameters and conditions capable of satisfying all constraints produced, at best, a design point receiver efficiency of 78.2%, or 80.5% when excluding receiver intercept efficiency. Variation in the optimal receiver performance relative to uncertainty in the binding maximum velocity, minimum wall thickness, and minimum lifetime constraints is presented.

14 SOLAR ENERGY↗

Techno-economic comparison of sCO 2 cycles for particle-based CSP at design-point conditions

In this work, we compare the techno-economic performance of supercritical carbon dioxide power cycles integrated in a particle CSP system. We model four core cycle configurations: simple (with optional bypass), recompression (with optional bypass), partial cooling, and turbine split flow, which each demonstrate different benefits in a CSP system, such as high efficiency, low cost, or large HTF temperature differences. We parametrically sweep cycle design variables for each configuration. The set of power cycle performance results are then combined with a design point particle CSP system model which calculates the system specific cost. The simple cycle and turbine split flow cycles have the best performance in the baseline results, with system specific costs of 5,912 and 5,899 $\$$/kWe respectively. In addition to the baseline set of results, we also vary key parameters and costs in a sensitivity study. The cycle designs with the best system performance limit their efficiency to ~45 %, despite demonstrating higher maximum efficiencies, due to the rapid increase in cost of recuperation as efficiencies rise. The simple cycle has strong performance in the analysis and is on average only 1.4 % worse than the optimal configuration. Lowered turbine inlet temperatures from the sensitivity study improve performance by reducing the PHX and turbine cost. Decreasing the inlet temperature from 700 to 625°C results in an >8 % decrease in system specific cost. Future work should expand sensitivity analyses to colder turbine inlet temperatures and calculate system performance by simulating annual performance with off-design solar and cycle component models.

14 SOLAR ENERGY↗

Modeling and Simulating Diffused Aeration for Hydrogen Removal from Expansion Tanks of Parabolic Trough Solar Thermal Power Plants

High-temperature decomposition of organic heat transfer fluids (HTFs) can cause hydrogen build-up in the receiver annulus of parabolic trough power plants. This build-up increases the receiver thermal losses and results in a decline in power output. Prior work has shown that removal of hydrogen from the expansion tank can be an effective mitigation strategy. This paper presents a modeling methodology and simulation results for passive and diffused aeration removal of hydrogen from the expansion tank. Focus is on estimating the mass transfer of hydrogen from the HTF into the headspace gas across the surface and bubble liquid/gas interfaces. Simulations for the operation conditions and expansion tank geometry of the Nevada Solar One power plant (located near Las Vegas, Nevada, USA) show that passive removal (surface mass transfer only) may be sufficient to obtain hydrogen removal rates of 1.7 x 10-4 mol/s (minimal removal rate necessary). A diffused aeration system (surface plus bubble mass transfer) with gas injection volume rates up to 100 L/s may be necessary to obtain a hydrogen removal rate of 2.0 x 10-4 mol/s (optimal removal rate).

14 SOLAR ENERGY↗