Search NASA⌕ Search

SEARCH · Search NASA

Results for “HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Haxall-based (Axon) fault auto-correction package for building HVAC system (Haxall-based Fault Correction) v1.0

Haxall-based Fault Correction is a set of fault auto-correction algorithms implemented using the Axon language. These algorithms can automatically fix equipment and control problems as they arise and improve the operation of building Heating, Ventilation, and Air Conditioning (HVAC) systems. The coded auto-correction algorithms include mitigation of rogue zones, ASHRAE Guideline 36 static pressure and supply air reset, resolution of control hunting due to improper settings in a proportional-integral-derivative controller, correction of biased temperature sensors, etc. FDD tools with enhanced auto-correction capability can resolve control problems as they are detected, increasing energy savings and emissions reductions while freeing up operational staff expertise for the hardest facility problems.

Vitti, Raphael↗

High Velocity AI Cache (HVAC)

HVAC is a high-performance caching system designed for large-scale AI training workloads.

Khan, Awais [Oak Ridge National Laboratory (ORNL),↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Re-Envisioning RCx: Achieving Max Potential HVAC Controls Retrofits through Modernized BAS Hardware and Software

Most existing buildings have sub-optimal heating, ventilation, and air conditioning (HVAC) controls, resulting in wasted energy and occupant discomfort. Retro-commissioning (RCx) addresses many of these issues, but it is a lengthy and highly customized process. Limited capabilities of existing building automation system hardware restricts the scope of most RCx projects. Incentive programs consider building automation system (BAS) hardware retrofits to be high-capital investments and do not allow them in typical RCx programs. This paper describes work that the authors are leading to facilitate technical and market innovation in the BAS industry to unlock large savings in existing commercial buildings through deep retrofits of BAS hardware and software. California and New York research projects are demonstrating BAS retrofits leveraging the American Society of Heating, Refrigeration, and Air Conditioning Engineers’ (ASHRAE) new Guideline 36 high performance sequences of operation to achieve greater than 20 percent whole building energy savings, while saving costs and reducing risk through streamlined processes and standardization across BAS manufacturer product lines and across implementation practices. This paper describes market barriers that impede achieving deep savings from BAS retrofits in custom incentive and traditional RCx programs and presents a new maximum potential BAS retrofit model that addresses these barriers. The new model leverages the authors’ efforts in market enablement through open standards, BAS industry partnerships, and tools for cost-effective scaling that includes tools for project screening, savings calculations, and measurement and verification (M&V). This approach is widely applicable and will be ready for at-scale implementation within two years.

Paliaga, Gwelen↗

HVAC Duct Pressure Optimization System

The US Department of Energy, the California Energy Commission, and other public and private entities including the venture capital community are seeking technical solutions that include “smart, grid-interactive, efficient buildings - to best serve the needs of building occupants and the grid while reducing energy consumption overall.” In this paper, a systems engineering approach is used to examine elements of a prior proof-of-concept project along with new ideas seeking to justify additional research funding to further advance the technology. With additional research and development funding, the technology described here has the potential to achieve success toward development of a commercially viable product. These types of projects provide financial and environmental benefit to American taxpayers and investors. Cost effectiveness and return on investment are key criteria for energy efficiency projects. By evaluating the end-to-end processes including manufacturing, installation, commissioning and comparing various options, we arrived at a proposed implementation concept of a HVAC Duct Pressure Optimization System that saves energy in commercial buildings and improves the return on investment by a factor of 6X compared to previous research projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Demand Limiting and Optimization of HVAC Systems for Common Areas in High-Rise Multi-Family Housing (CRADA 518)

This project aims to create an innovative energy saving solution that is affordable and easy to implement. Initially, the proposed solution will fulfill an existing need for HVAC systems that serve multi-family housing. However, the solution can be easily expanded to other markets such as large hospitals, hotels, and commercial buildings. The proposed solution will be creatively packaged so that it can work where peak demand charge is high or where goal is to conserve energy and reduce carbon footprint. Of course, both Peak Demand Limiting (PDL) and Set-point optimization (SPO) can also operate simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Serpentine Heat Exchangers to Minimize Number of Joints and Leakage in HVAC&R Systems

Refrigerant leakage has a significant impact on heating, ventilation, air conditioning and refrigeration (HVAC&R) industries in terms of both greenhouse gas (GHG) emissions and lost efficiency of the systems themselves. One of the major causes of refrigerant leakage is braze joints within a vapor compression system. The brazing process is often inconsistent and almost always imperfect. As a result, braze joints are left vulnerable to leaks and can be weaker than non-brazed tubing. Conventional tube-fin heat exchangers are manufactured using one brazed joint per tube. An alternative to the conventional approach is the use of a single continuous serpentine tube. An Advanced Serpentine Heat Exchanger was developed to provide a heat transfer solution that meets or exceeds performance while also significantly reducing the number of joints and, consequently, the potential for refrigerant leakage. The developed serpentine heat exchanger not only delivers on performance, but is also cost competitive with conventional heat exchangers on the market.

30 DIRECT ENERGY CONVERSION↗

Highly-Efficient Microemulsion-Based Absorption Chillers for HVAC Application

Air conditioning is a necessity to achieve a comfortable, habitable home or office for many places in US. However, vapor compression air conditioners are largely made with chlorofluorocarbon refrigerants, or CFCs, which create problems for a world grappling with climate change. In addition, vapor compression air conditioners are driven by electricity. Cooling and heating represent one-third of building electrical energy consumption in US. An absorption chiller is different to vapor compression chillers or air conditioners because it doesn’t use conventional refrigerants, like CFC. Instead, they may use water as the refrigerant which is mixed with safe and nontoxic absorbents. The research performed in this project advanced the understanding of absorption cooling technology and its application in HVAC. Various technologies were explored to improve the performance of the desorber and absorber components in the absorption chillers.

42 ENGINEERING↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

HVAC modifications and computerized energy analysis for the Operations Support Building at the Mars Deep Space Station at Goldstone

The key heating, ventilation, and air-conditioning (HVAC) modifications implemented at the Mars Deep Space Station's Operation Support Building at Jet Propulsion Laboratories (JPL) in order to reduce energy consumption and decrease operating costs are described. An energy analysis comparison between the computer simulated model for the building and the actual meter data was presented. The measurement performance data showed that the cumulative energy savings was about 21% for the period 1979 to 1981. The deviation from simulated data to measurement performance data was only about 3%.

Halperin, A.↗

Can We Fix It Automatically? Development of Fault Auto-Correction Algorithms for HVAC and Lighting Systems

A fault detection and diagnostics (FDD) tool is a type of energy management and information system designed to continuously identify the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and application of automated analytics. Building owners and operators at the leading edge of technology adoption are using FDD tools to enable average whole-building portfolio savings of 8 percent. Although FDD tools can inform building operators of operational faults, currently a manual action is always required to correct faults and generate the associated energy savings. A subset of faults, however, such as biased sensors and manual override, can be addressed automatically, removing the need for operations and maintenance staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability, as well as the technical and economic performance, of FDD technologies. In this paper, we present the development of 10 innovative fault auto-correction algorithms for HVAC and lighting systems. When the auto-correction routine is triggered, it will overwrite the control setpoints or other variables (via BACnet or other protocol) to implement the intended changes. These algorithms are able to automatically correct the faults or improve the operation associated with an incorrectly programmed schedule, override manual control, sensor bias, control hunting, rogue zone, and less aggressive setpoints/setpoints setback. The paper will also discuss the implementation of the auto-correction algorithms in FDD software products.

Lin, Guanjing↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗

Simulations of Grid-Responsive HVAC Cooling Measures via Ice/PCM storage

This study uses EnergyPlus building energy simulations to assess grid-responsive HVAC cooling measures during peak hours having high electricity price, including: lock the high capacity of a two-speed cooling coil during grid-response hours; and use ice/PCM energy storage to drive a chilled water coil and meet the cooling load, when shut off the main electric cooling coil. Here, the impacts on peak power reductions, energy and utility cost savings, and comfort levels in residential buildings of two U.S. cities were revealed.

Shen, Bo↗