Secondary Waste Simulant Development for Cast Stone Formulation Testing

Washington River Protection Solutions, LLC (WRPS) funded Pacific Northwest National Laboratory (PNNL) to conduct a waste form testing program to implement aspects of the Secondary Liquid Waste Treatment Cast Stone Technology Development Plan (Ashley 2012) and the Hanford Site Secondary Waste Roadmap (PNNL 2009) related to the development and qualification of Cast Stone as a potential waste form for the solidification of aqueous wastes from the Hanford Site after the aqueous wastes are treated at the Effluent Treatment Facility (ETF). The current baseline is that the resultant Cast Stone (or grout) solid waste forms would be disposed at the Integrated Disposal Facility (IDF). Data and results of this testing program will be used in the upcoming performance assessment of the IDF and in the design and operation of a solidification treatment unit planned to be added to the ETF. The purpose of the work described in this report is to 1) develop simulants for the waste streams that are currently being fed and future WTP secondary waste streams also to be fed into the ETF and 2) prepare simulants to use for preparation of grout or Cast Stone solid waste forms for testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance-based simulants for Hanford radioactive waste treatment process testing

Radioactive wastes from nuclear fuel processing are stored in large underground storage tanks at the Hanford Nuclear Reservation. Treatment and remediation require that waste feed from the storage tanks be delivered to the Hanford Tank Waste Treatment and Immobilization Plant continually for the duration of the treatment mission. Furthermore, the complex physical and chemical processes required for this mission, the significant scale, and the hazardous nature of the waste necessitate the use of simulants in process testing. A new class of simulants, “performance-based simulants,” has been developed to match the process performance of the simulant to actual waste performance data.

Hanford tank waste treatment↗

Secondary Waste Form Down-Selection Data Package—DuraLith

This data package developed for the DuraLith wasteform includes information available in the open literature and from data obtained from testing currently underway. DuraLith is an alkali-activated geopolymer waste form developed by the Vitreous State Laboratory at The Catholic University of America (VSL-CUA) for encapsulating liquid radioactive waste. A DuraLith waste form developed for treating Hanford secondary waste liquids is prepared by alkali-activation of a mixture of ground blast furnace slag and metakaolinite with sand used as a filler material. Based on optimization tests, solid waste loading of {approx}7.5% and {approx}14.7 % has been achieved using the Hanford secondary waste S1 and S4 simulants, respectively. The Na loading in both cases is equivalent to {approx}6 M. Some of the critical parameters for the DuraLith process include, hydrogen generation and heat evolution during activator solution preparation using the waste simulant, heat evolution during and after mixing the activator solution with the dry ingredients, and a working window of {approx}20 minutes to complete the pouring of the DuraLith mixture into molds. Results of the most recent testing indicated that the working window can be extended to {approx}30 minutes if 75 wt% of the binder components, namely, blast furnace slag and metakaolin are replaced by Class F fly ash. A preliminary DuraLith process flow sheet developed by VSL-CUA for processing Hanford secondary waste indicated that 10 to 22 waste monoliths (each 48 ft3 in volume) can be produced per day. There are no current pilot-scale or full-scale DuraLith plants under construction or in operation; therefore, the cost of DuraLith production is unknown. The results of the non-regulatory leach tests, EPA Draft 1313 and 1316, Waste Simulant S1-optimized DuraLith specimens indicated that the concentrations of RCRA metals (Ag, Cd, Cr, Hg, and Pb) in the leachates were well below the Universal Treatment Standard limits in 40 CFR 268.48. The data from the EPA draft 1315 leach test showed that LI values for COCs, namely 99Tc and I, ranged from 8.2 to 11.4 and 4.3 to 7.5, respectively. These values indicate that 99Tc meets the WAC LI requirement of 9.0 whereas, the LI values for I does not meet the WAC requirement of 11.0. Results of Toxicity Characteristic Leaching Procedure (TCLP)(EPA Method 1311) conducted on Waste Simulant S1-optimized DuraLith specimens, indicated that the concentrations of RCRA metals (Ag, As, Cd, Cr, Hg, and Pb) in the leachates were well below the Universal Treatment Standard limits in 40 CFR 268.48. The data from the ANSI/ANS 16.1 leach test showed that LI values for COC, namely Re (as a Tc surrogate), ranged from 8.06 to 10.81. The LI value for another COC, namely I, was not measured in this test. The results of the compressive strength testing of Waste Simulant S1-optimized DuraLith specimens indicated that the monoliths were physically robust with compressive strengths ranging from 115.5 MPa (16757 psi) to 156.2 MPA (22667 psi).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FINAL FRONTIER AT HANFORD TACKLING THE CENTRAL PLATEAU

The large land area in the center of the vast Department of Energy (DOE) Hanford Site in southeast Washington State is known as 'the plateau'--aptly named because its surface elevations are 250-300 feet above the groundwater table. By contrast, areas on the 585-square mile Site that border the Columbia River sit just 30-80 feet above the water table. The Central Plateau, which covers an ellipse of approximately 70 square miles, contains Hanford's radiochemical reprocessing areas--the 200 East and 200 West Areas--and includes the most highly radioactive waste and contaminated facilities on the Site. Five 'canyons' where chemical processes were used to separate out plutonium (Pu), 884 identified soil waste sites (including approximately 50 miles of solid waste burial trenches), more than 900 structures, and all of Hanford's liquid waste storage tanks reside in the Central Plateau. (Notes: Canyons is a nickname given by Hanford workers to the chemical reprocessing facilities. The 177, underground waste tanks at Hanford comprise a separate work scope and are not under Fluor's management). Fluor Hanford, a DOE prime cleanup contractor at the Site for the past 12 years, has moved aggressively to investigate Central Plateau waste sites in the last few years, digging more than 500 boreholes, test pits, direct soil 'pushes' or drive points; logging geophysical data sets; and performing electrical-resistivity scans (a non-intrusive technique that maps patterns of sub-surface soil conductivity). The goal is to identify areas of contamination areas in soil and solid waste sites, so that cost-effective and appropriate decisions on remediation can be made. In 2007, Fluor developed a new work plan for DOE that added 238 soil waste-site characterization activities in the Central Plateau during fiscal years (FYs) 2007-2010. This number represents a 50 percent increase over similar work previously done in central Hanford. Work Plans are among the required steps in the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) cleanup process. The CERCLA process is used to oversee the investigation, decision-making and remediation of 'past practices' (historical) sites, as opposed to sites in active use. For the first several years of Hanford's cleanup work, everyone concerned--the Department, contractors, regulatory agencies, stakeholders and Indian nations and tribes--focused efforts on the rivershore. The magnificent Columbia River--eighth largest in the world--flows through and by the Hanford Site for 52 miles. Two million people live downstream from Hanford along the Columbia before it empties into the Pacific Ocean. Further, the part of the river known as the 'Hanford Reach' is a prime habitat for salmon, steelhead, sturgeon and other species of fish. In fact, it provides a spawning ground to more salmon than any other stretch of river in the United States outside of Alaska. For these reasons, protecting the Columbia by cleaning up waste directly along its shoreline was an early priority in Hanford's Federal Facility Agreement and Consent Order (or Tri-Party Agreement) signed in 1989 among the DOE, U.S. Environmental Protection Agency (EPA) and Washington State to govern cleanup. However, Tri-Party Agreement signatories and others concerned with Hanford and the Columbia River, knew that the waste located in, and beneath, the Central Plateau could also pose dangers to the waterway. While the waste in central Hanford might move more slowly, and pose fewer immediate threats, it would have to be dealt with as cleanup progressed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Composition Measurements and Product Consistency Test Results for the EMHQ-LBE-04-B Glass

This report provides the results from the chemical analyses of the glass composition and the Product Consistency Test leachate analyses for the EMHQ-LBE-04-B glass. These data will be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TESTING GROUND BASED GEOPHYSICAL TECHNIQUES TO REFINE ELECTROMAGNETIC SURVEYS NORTH OF THE 300 AREA HANFORD WASHINGTON

Airborne electromagnetic (AEM) surveys were flown during fiscal year (FY) 2008 within the 600 Area in an attempt to characterize the underlying subsurface and to aid in the closure and remediation design study goals for the 200-PO-1 Groundwater Operable Unit (OU). The rationale for using the AEM surveys was that airborne surveys can cover large areas rapidly at relatively low costs with minimal cultural impact, and observed geo-electrical anomalies could be correlated with important subsurface geologic and hydrogeologic features. Initial interpretation of the AEM surveys indicated a tenuous correlation with the underlying geology, from which several anomalous zones likely associated with channels/erosional features incised into the Ringold units were identified near the River Corridor. Preliminary modeling resulted in a slightly improved correlation but revealed that more information was required to constrain the modeling (SGW-39674, Airborne Electromagnetic Survey Report, 200-PO-1 Groundwater Operable Unit, 600 Area, Hanford Site). Both time-and frequency domain AEM surveys were collected with the densest coverage occurring adjacent to the Columbia River Corridor. Time domain surveys targeted deeper subsurface features (e.g., top-of-basalt) and were acquired using the HeliGEOTEM{reg_sign} system along north-south flight lines with a nominal 400 m (1,312 ft) spacing. The frequency domain RESOLVE system acquired electromagnetic (EM) data along tighter spaced (100 m [328 ft] and 200 m [656 ft]) north-south profiles in the eastern fifth of the 200-PO-1 Groundwater OU (immediately adjacent to the River Corridor). The overall goal of this study is to provide further quantification of the AEM survey results, using ground based geophysical methods, and to link results to the underlying geology and/or hydrogeology. Specific goals of this project are as follows: (1) Test ground based geophysical techniques for the efficacy in delineating underlying geology; (2) Use ground measurements to refine interpretations of AEM data; and (3) Improve the calibration and correlation of AEM information. The potential benefits of this project are as follows: (1) Develop a tool to map subsurface units at the Hanford Site in a rapid and cost effective manner; (2) Map groundwater pathways within the River Corridor; and (3) Aid development of the conceptual site model. If anomalies observed in the AEM data can be correlated with subsurface geology, then the rapid scanning and non-intrusive capabilities provided by the airborne surveys can be used at the Hanford Site to screen for areas that warrant further investigation.

58 GEOSCIENCES↗

Aligned FTICR-MS, Respiration, and Biochemical Transformation Data from Columbia River Sediment Incubations Associated with: “Carbon Limitation Leads to Thermodynamic Regulation of Aerobic Metabolism”

Columbia River hyporheic zone sediments from the Hanford Site 300 Area in eastern Washington were incubated in a full factorial design with different organic matter (OM) amendments. The aim of the experiment was to test the influence of OM thermodynamics on aerobic respiration across different organic carbon pools and concentrations. This dataset is comprised of (1) a csv with high resolution characterization of dissolved organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) analyzed through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory), (2) a csv with sample IDs, replicates, amendments, dissolved oxygen (DO) measurements, and sampling time points, (3) a csv with sample IDs, replicates, respiration rates, FTICR summary metrics, and relative abundance of chemical classes; and (4) a csv with the number of chemical transformations in each sample replicate (microcosm). The data are associated with the publication “Carbon Limitation Leads to Thermodynamic Regulation of Aerobic Metabolism” published in ES&T Letters (Garayburu-Caruso et al., 2020). Please use the data package’s DOI to cite the data package. We ask that you acknowledge the U.S. Department of Energy (DOE) Biological and Environmental Research (BER) Subsurface Biogeochemical Research (SBR) program when using the data. All data are free to be used for any purpose, such as for manuscripts, presentations, and grant proposals. There is no obligation to include data package authors as co-authors.

54 ENVIRONMENTAL SCIENCES↗

Design, Fabrication and Start-up of Test Facilities for the LAWPS Full-Scale IX Column Test and Engineering Scale Test - 17418

The U.S. Department of Energy (DOE), Office of River Protection's (ORP) primary mission is to retrieve and treat Hanford's tank waste and close the Tank Farms to protect the Columbia River. Mixed radioactive waste is stored in 177 underground tanks at the Hanford Site as reported in DOE/ORP 2003-02, Environmental Impact Statement for Retrieval, Treatment, and Disposal of Tank Waste and Closure of the Single Shell Tanks at the Hanford Site, Richland WA, Inventory and Source Term Data Package. The 177 underground tanks are estimated to contain about 56 million gallons of waste. The Low Activity Waste Pretreatment System (LAWPS) Project provides for the early production of immobilized low activity waste (ILAW) by feeding LAW directly from Tank Farms to the Hanford Waste Treatment Plant's (WTP's) LAW Facility, bypassing the Pretreatment Facility. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated in the LAWPS to meet the WTP LAW waste acceptance criteria. The LAWPS will also facilitate the return of secondary liquid wastes from the WTP LAW Vitrification Facility to the Tank Farms. In November of 2015 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to the AECOM Team to design, fabricate and operate two test platforms to generate performance data at two different scales and demonstrate technology maturation. The first platform models the ion exchange (IX) columns at full scale, and the second platform models the integrated flowsheet (cross flow filter (CFF) and IX) at 1/9. scale. Both test platforms underwent shakedown and start-up testing in August 2016 and moved into actual testing and NQA-1 data generation shortly thereafter. This paper covers the engineering design, procurement, construction, installation, and acceptance testing of the test platforms (which are now operational) under an aggressive fast track schedule, and initial test data as available. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utility of Bromide and Heat Tracers for Aquifer Characterization Affected by Highly Transient Flow Conditions

A tracer test using both bromide and heat tracers conducted at the Integrated Field Research Challenge site in Hanford 300 Area (300A), Washington, provided an instrument for evaluating the utility of bromide and heat tracers for aquifer characterization. The bromide tracer data were critical to improving the calibration of the flow model complicated by the highly dynamic nature of the flow field. However, most bromide concentrations were obtained from fully screened observation wells, lacking depth-specific resolution for vertical characterization. On the other hand, depth-specific temperature data were relatively simple and inexpensive to acquire. However, temperature-driven fluid density effects influenced heat plume movement. Moreover, the temperature data contained “noise” caused by heating during fluid injection and sampling events. Using the hydraulic conductivity distribution obtained from the calibration of the bromide transport model, the temperature depth profiles and arrival times of temperature peaks simulated by the heat transport model were in reasonable agreement with observations. This suggested that heat can be used as a cost-effective proxy for solute tracers for calibration of the hydraulic conductivity distribution, especially in the vertical direction. However, a heat tracer test must be carefully designed and executed to minimize fluid density effects and sources of noise in temperature data. A sensitivity analysis also revealed that heat transport was most sensitive to hydraulic conductivity and porosity, less sensitive to thermal distribution factor, and least sensitive to thermal dispersion and heat conduction. This indicated that the hydraulic conductivity remains the primary calibration parameter for heat transport.

Ma, Rui↗

Comparison of Waste Feed Delivery Small Scale Mixing Demonstration Simulant to Hanford Waste

The Hanford double-shell tank (DST) system provides the staging location for waste feed delivery to the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Hall (2008) includes WTP acceptance criteria that describe physical and chemical characteristics of the waste that must be certified as acceptable before the waste is transferred from the DSTs to the WTP. One of the more challenging requirements relates to the sampling and characterization of the undissolved solids (UDS) in a waste feed DST. The objectives of Washington River Protection Solutions' (WRPS) Small Scale Mixing Demonstration (SSMD) project are to understand and demonstrate the DST sampling and batch transfer performance at multiple scales using slurry simulants comprised of UDS particles and liquid (Townson 2009). The SSMD project utilizes geometrically scaled DST feed tanks to generate mixing, sampling, and transfer test data. In Phase 2 of the testing, RPP-49740, the 5-part simulant defined in RPP-48358 was used as the waste slurry simulant. The Phase 2 test data are being used to estimate the expected performance of the prototypic systems in the full-scale DSTs. As such, understanding of the how the small-scale systems as well as the simulant relate to the full-scale DSTs and actual waste is required. The focus of this report is comparison of the size and density of the 5-part SSMD simulant to that of the Hanford waste. This is accomplished by computing metrics for particle mobilization, suspension, settling, transfer line intake, and pipeline transfer from the characterization of the 5-part SSMD simulant and characterizations of the Hanford waste. In addition, the effects of the suspending fluid characteristics on the test results are considered, and a computational fluid dynamics tool useful to quantify uncertainties from simulant selections is discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Miniature motorized inspection tool for DOE Hanford site tank bottoms - 15700

Recently, small amounts of waste have been found in the annulus of tank AY-102, prompting the need for developing inspection tools that can identify the cause and location of the leak. Three separate access paths can be used to obtain information regarding the tank bottom condition. The inspection may be conducted via: 1) Refractory air slots through the annulus; 2) 4'' annulus air supply pipe to central air slots; 3) 6'' leak detection pit drain from the central sump. There are various environmental and physical constraints which the tool will have to adhere to. In order for the tool to be successful, it must be capable of the following: Travel through small cooling channels with dimensions as small as 1.5'' x 1.5''; Provide live video feedback; Produce enough torque to overcome the tether drag force; Inverted travel to avoid obstacles such as tank corrosion; Navigate up to 38 feet to the tank center, while maneuvering through four 90 deg. turns. A model of the inspection tool has been designed, assembled and reported. Areas of potential performance improvement were observed; these areas are the basis of the following design, as seen above. The changes include: The addition of an additional 4 wheels; Body modification to house the camera; A loft on the bottom from the tools edge to the magnets lowest edge; Shaving the hubs of the current wheels; Control method changed to a joystick. The tank configuration through which the tool will have to maneuver are the following: 72 outer ring slots (1.5'' x 1.5'' x 17'); 36 ring slots (2'' x 1.5'' x 12'); 18 inner slots (3'' x 1.5'' x 7'). The components used for this design iteration are not radiation hardened nor are they designed to withstand elevated temperatures. However, this prototype has been constructed with the final goal of being radiation hardened and able to withstand elevated temperatures in mind. The components that make up this design iteration are the following: Arduino Uno board with ATMega328 micro-controller; Joystick shield kit for the Arduino Uno; Eggsnow USB Borescope Endoscope 5.5 mm inspection camera; 136:1 Sub-micro Plastic Planetary Gearmotor; 14 x 4.5 mm wheels; 3D-printed body; 3D-printed free rolling shafts; Neodymium magnet - 1 h x 3/8 h x 1/16 h; 4.53 lb pull force. In the time to come, there are a few goals that are to be completed. The first group of tasks is associated with the testing and recording of data of the current prototype. This data will be analyzed and appropriate action will be taken based on the results of the testing. The testing will include simulating the challenges that the tool will face in the AY-102 tank. Working with the Hanford DOE site, a bag of Kaolin 2200 will be acquired to be used for the test bed to simulate tank conditions. Further modification will then be made to enable the tool to be able to maneuver through a 90 deg. turn. Completion of this task will be a major milestone, as this tool will be readily usable in the other tanks containing HLW; as other tanks will be easier to maneuver through.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Letter Report: LAW Simulant Development for Cast Stone Screening Test

More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is being constructed to treat the wastes and immobilize them in a glass waste form. The WTP includes a pretreatment facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the nonradioactive chemicals. The HLW will be converted to glass in the HLW vitrification facility for ultimate disposal at an offsite federal repository. At least a portion (~35%) of the LAW will be converted to glass in the LAW vitrification facility and will be disposed of onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize the wastes destined for each facility. However, a second facility will be needed for the expected volume of additional LAW requiring immobilization. A cementitious waste form known as Cast Stone is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with waste acceptance criteria for the IDF disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. Further, the waste form must be tested to provide the technical basis for understanding the long term performance of the waste form in the IDF disposal environment. These waste form performance data are needed to support risk assessment and performance assessment (PA) analyses of the long-term environmental impact of the waste disposal in the IDF. A testing program was developed in fiscal year (FY) 2012 describing in some detail the work needed to develop and qualify Cast Stone as a waste form for the solidification of Hanford LAW (Westsik et al. 2012). Included within Westsik et al. (2012) is a section on the near-term needs to address Tri-Party Agreement Milestone M-062-40ZZ. The objectives of the testing program to be conducted in FY 2013 and FY 2014 are to: • Determine an acceptable formulation for the LAW Cast Stone waste form. • Evaluate sources of dry materials for preparing the LAW Cast Stone. • Demonstrate the robustness of the Cast Stone waste form for a range of LAW compositions. • Demonstrate the robustness of the formulation for variability in the Cast Stone process. • Provide Cast Stone contaminant release data for PA and risk assessment evaluations. The first step in determining an acceptable formulation for the LAW Cast Stone waste form is to conduct screening tests to examine expected ranges in pretreated LAW composition, waste stream concentrations, dry-materials sources, and mix ratios of waste feed to dry blend. A statistically designed test matrix will be used to evaluate the effects of these key parameters on the properties of the Cast Stone as it is initially prepared and after curing. The second phase of testing will focus on selection of a baseline Cast Stone formulation for LAW and demonstrating that Cast Stone can meet expected waste form requirements for disposal in the IDF. It is expected that this testing will use the results of the screening tests to define a smaller suite of tests to refine the composition of the baseline Cast Stone formulation (e.g. waste concentration, water to dry mix ratio, waste loading).

Russell, Renee L.↗

Enhanced Hanford High-Aluminum Waste Glass Property Data Development

This study investigated the effects of aluminum concentration on simulated high level waste glass properties to eventually establish an aluminum limit (as single-component or multiple-component constraints) for glass formulations for high-aluminum Hanford wastes. A test matrix of 25 high-aluminum glasses (20 = Al 2 O 3 = 28.57 wt%) was generated, and the chemical compositions were measured. The following properties were measured: crystal formation after centerline canister cooling, crystallinity as a function of temperature, density, viscosity, electrical conductivity, toxic leaching characteristics using the Toxicity Characteristic Leaching Procedure, product consistency using the Product Consistency Test, and SO 3 solubility. These results are reported here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Retrieval Demonstrations of the Hanford Waste End Effector - 19383

This paper describes advanced retrieval demonstrations of the Hanford Waste End Effector (HWEE) at the Washington River Protection Solutions (WRPS) Cold Test Facility conducted by Pacific Northwest National Laboratory (PNNL) in co-operation with the U.S. Department of Energy - Office of River Protection and WRPS. The HWEE is a water-based scarifier originally developed by PNNL for the U.S. Department of Energy tank retrieval systems in the 1990's as the confined sluicing end effector and later used with additional development in the waste retrieval of tanks at Oak Ridge National Laboratory. The HWEE is being assessed for potential use in Hanford tank retrievals because it is expected to use less water during waste retrieval than other water-based methods (e.g., sluicing) previously used in Hanford tanks. This is primarily because the HWEE uses three rotating high-pressure jets for dislodging the waste and a high-velocity conveyance system to retrieve the water and the waste locally at the point of waste dislodging. The retrieval demonstrations build on previous development testing (Phase I) completed in 2017 by addressing key tank waste challenges, including retrieval of a mixed layered simulant and retrieval of uneven simulant profiles like that found near tank walls. The tests involved retrieval of water and kaolin (sludge) simulant to determine pumping rate, dilution factors, and a demonstration of vertical pumping capability. Upgrades to the HWEE for Phase II testing included a more robust inlet screen, internal flush jet modification for lower water usage, and removal of the external flush mole that was not used during Phase I retrieval testing. In addition, a rotational positioning capability was added to the three-dimensional gantry to gain additional movement capability and flexibility needed to implement more complex retrieval mining techniques. Two simulant configuration options using existing simulant materials were defined to represent key Hanford tank waste properties: 1) layered waste (e.g., strong crust over weaker sediment) and 2) topography that is representative of tank waste (uneven surface). Historical information from Hanford waste, including tank history, sampling reports, and images, was investigated to define the simulant characteristics and physical configuration. Using the layered simulant configuration, retrieval tests focused on demonstrating the same operational parameters irrespective of simulant strength. The focus of the topographical retrieval test was to demonstrate the ability to clean next to the tank wall using a tilted HWEE and to demonstrate water confinement using a specific mining strategy. This paper will describe the Phase II test equipment, instrumentation, simulant preparation procedures, and testing methodology. Testing results that will be presented include HWEE water usage versus operating pressure, simulant characterization data, dilution ratios, and retrieval rates. Reaction forces and other factors that would affect the remote operation of the HWEE will also be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Direct-Push Vadose Zone Sediments from the 241-B and 241-BX Tank Farms

Geochemical tests provide evidence for the transit of a plume of caustic waste solution through the sediment column at the Hanford 241-B and -BX Tank Farms. Direct-push samples recovered from boreholes surrounding Tanks 241-B-110 and 241-BX-102 and related waste transfer lines and diversion boxes included sediments typical of those previously recovered from other localities on the Hanford Site. The Hanford formation sediments are dominantly quartzo-feldspathic sands strewn with lithic fragments, displaying a range of particle size distributions and sorting characteristics. Some moderately well-sorted, fine-grained lithologies are interpreted as lenticular bodies irregularly dispersed in coarser-grained, more poorly sorted sediments. Tier I tests conducted on the vadose zone sediments revealed an inverse correlation between moisture content and sediment size fraction (i.e., there is greater moisture content in finer-grained sediments). The Tier I tests also showed that the pore water solutions were likely sodium-rich, moderately saline, and possessed higher pH values than background (untainted) sediments. These data are characteristic of sediments that have encountered sodium-rich, saline, caustic waste solution, as documented in other reports at other suspect contamination sites around Hanford. Analyses of solutions from 1:1 water extracts reveal relatively balanced cation and anion concentrations, indicating that most of the geochemical species have been accounted for. The water extract data for affected sediments also indicate unusually high concentrations of aluminum, iron, and phosphorus. The relatively high concentrations of aluminum and iron may be the result of dissolution of secondary amorphous phases that precipitated after a reactive plume partially dissolved aluminum- and iron-bearing phases as it migrated through the sediment column. On the other hand, the presence of elevated concentrations of phosphorous may be the tell-tale signature of wastes derived from the bismuth phosphate separation process. Elements typically mobile in the geosphere, such as technetium-99, are present at either low concentrations or are below the analytical detection limit. However, we expect that the mobile elements would be present mainly along a narrow plume front, and if this front had passed deeper into the sediment profile than depths sampled, the retention of these elements would be minor. On the other hand for the direct push sediments from around BX Tank Farm, uranium-238 was detected in nearly all sediment specimens (by acid extract experiments) at concentrations above the natural crustal average (0.763 pCi/g), and we also detected the presence of several anthropogenic radioisotopes, such as cobalt-60, cesium-137, europium-154, and europium-155 (by gamma energy analysis). These data are direct confirmation of contamination of the sediments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization of LAW Glass Former Additives

The primary objective of this work was to collect data to support processing Hanford LAW streams at higher rates through changes in mineralogy, forms, and grain sizes of the GFCs. This was achieved through assessment of LAW feeds with different GFCs by feed rheology testing, testing with a vertical gradient furnace (VGF) system to assess melt rates, and processing selected modified LAW feeds through a DM100 melter to measure glass production rates and processing behavior. A high waste loading glass formulation developed in earlier work [8] for an LAW composition specified by WTP was used for rheology, VGF, and melter testing. The glass composition, ORPLA20, is based on LAW tank AN-105; the glass has a waste loading of 31.4 wt% and a Na2O content of 24.0 wt%. Another high waste loading glass formulation developed in earlier work for an LAW composition specified by WTP was also used for VGF testing to investigate the effects of changes in GFCs on melt rate for a second waste and glass composition. That glass composition is ORPLD6, which is based on LAW tank AN-102; the glass has a waste loading of 25.9 wt% and a Na2O content of 22.0 wt%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Glass Property-Composition Models Update for use in Direct Feed High-Level Waste Flowsheet Development: EWG3.0

A set of preliminary glass property models and constraints were developed and augmented by models from literature for use in design of Direct Feed High-Level Waste glasses for flowsheet evaluation, testing, and design of the High-Level Waste Facility at the Hanford Waste Treatment and Immobilization Plant. These models and constraints are meant to be used as a placeholder while glass property-composition data gaps are filled and final plant operating models are developed. This report describes the motivation and intended use of the models, the compilation of data, model fitting and selection, and methods to apply the models and constraints in glass design, and offers example calculations demonstrating their intended use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Process Knowledge Concerning Organic Chemicals in Hanford Tank Waste Supernate

This report addresses the specific need to characterize double-shell tank supernates to meet the regulatory requirements and data quality objectives associated with Direct Feed Low Activity Waste, Tank-Side Cesium Removal, Low Activity Waste Pretreatment System, and Test Bed Initiative requirements. The use of process knowledge can greatly reduce the need for chemical analysis to meet regulatory requirements. This will decrease the cost of characterization and improve sample data turnaround times.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗