Search NASASearch

SEARCH · Search NASA

Results for “Heat Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

300 records · Page 8

Simulations of Yarn Micro-Mechanics of Woven Heat Shield Materials

Carbon and phenolic fibers are commonly used in ablative thermal protection materials, such as 3-dimensional Mid-Density Carbon Phenolic (3MDCP), a 3D-woven composite comprised of mixed-fiber yarn bundles. Predicting the micro-mechanical response and fracture of twisted yarns composed of brittle and ductile fibers requires a modeling approach that captures per-fiber yielding, fiber fracture, and inter-fiber friction and contact. This work presents an extended bonded particle model (BPM) for discrete element method (DEM) simulation of fiber and yarn mechanics, implemented in LAMMPS. The model builds on the incremental bond formulation of Guo et al. and introduces a piecewise elasto-plastic constitutive law for axial extension, enabling representation of fibers that yield before failure. 3MDCP yarns were constructed using measured fiber radius distributions and helical twist geometry. Tensile simulations of single-ply 3MDCP yarns show good agreement with vender stress–strain results. Fiber breakage models also show details on yarn breakage propagration, centered radially in the yarn. Yarn breakage of multi-ply 3MDCP also matched experimental observations in per-ply breakage; however, predicted yarn breakage strength were found higher than experimental observations.

Discrete Element Method

Simulations of Yarn Micro-Mechanics of Woven Heat Shield Materials (3MDCP)

Carbon and phenolic fibers are commonly used in ablative thermal protection materials, such as 3-dimensional Mid-Density Carbon Phenolic (3MDCP), a 3D-woven composite comprised of mixed-fiber yarn bundles. Predicting the micro-mechanical response and fracture of twisted yarns composed of brittle and ductile fibers requires a modeling approach that captures per-fiber yielding, fiber fracture, and inter-fiber friction and contact. This work presents an extended bonded particle model (BPM) for discrete element method (DEM) simulation of fiber and yarn mechanics, implemented in LAMMPS. The model builds on the incremental bond formulation of Guo et al. and introduces a piecewise elasto-plastic constitutive law for axial extension, enabling representation of fibers that yield before failure. 3MDCP yarns were constructed using measured fiber radius distributions and helical twist geometry. Tensile simulations of single-ply 3MDCP yarns show good agreement with vender stress–strain results. Fiber breakage models also show details on yarn breakage propagration, centered radially in the yarn. Yarn breakage of multi-ply 3MDCP also matched experimental observations in per-ply breakage; however, predicted yarn breakage strength were found higher than experimental observations.

Woven

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Ground Slope Effects on Lander Radiator Performance

Two sensitivity studies were performed to examine the drop in radiator heat rejection from slopes. Study #1 used a 5.5m tall reduced order asset to represent a small-lander/rover. Study #2 used a 20m asset represent a tall lander. The assets had body mounted horizontal, 45º inward-tilted, and vertical radiator orientations. The impact of slopes on different radiator orientations and on radiators pointing different directions (i.e., slope verses sun) was investigated. The studies were conducted at a polar location of -82.5ºS to capture the incident solar flux at the northmost, and therefore the hottest, range of potential Artemis landing sites (Mons Mouton Plateau).

Lunar Slope

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Automated Resupply of Consumables: Enhancement of Space Commercialization Opportunities

This paper addresses work performed at Rockwell International's Space Systems Division to investigate the feasibility of, and develop concepts for, automated and/or robotic resupply of consumables on orbit. The work focuses on the resupply of satellites and is described in five sections. First, the various problems relating the resupply on orbit are discussed: for example, economic concerns, fuel handling problems, and safety issues. Next major methods of effecting fuel transfer on orbit are summarized, together with their advantages and disadvantages. Direct fuel exchange is emphasized as the most feasible technique. Third, guidelines are developed for automated/robotic refueling mechanisms to accomplish on-orbit consumable resupply. For example, the guidelines cover safety, reliability, maintainability, alignment, induced loads, thermal protection, leaks, extravehicular activity (EVA) interface, and so on. The fourth part of the paper covers the development of design concepts for satellite resupply robotic interfaces that comply with the guidelines. Concepts include servicer fluid transfer system and satellite propulsion system, and a combined docking/umbilical device. Last, future technical development in these areas are discussed.

Davoud Manouchehri

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Metallurgical and Thermal Properties of 57Ni-40Ti-3Hf (wt%)

Selected properties of 57Ni-40Ti-3Hf (wt%) were measured to further develop this material for use in aerospace rolling-element bearings. The average grain size and microindentation hardness of the material at room temperature were 90 μm and 549 HV, respectively. From room temperature to 500 °C, electrical resistivity increased from 8.9×10–7 to 11.3×10–7 Ω⋅m, thermal expansion coefficients varied from 1.1×10–5 to 1.2×10–5 mm/mm⋅°C, specific heat increased from 0.44 to 0.53 W⋅sec/g⋅K, thermal diffusivity rose from approximately 0.003 to 0.005 cm2/sec and thermal conductivity increased from approximately 0.09 to 0.19 W/cm⋅K. The behavior of the material can be explained by well-known metallurgical theory. These results are expected to provide a basis for design and modeling of future aerospace components.

rule of mixtures

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

inviscid theory

NASA Space Launch System Artemis I & II Post Flight Ascent Aerothermal Environments Overview

Since 2011 the Aerosciences Branch/EV33 at NASA Marshall Space Flight Center has been involved with the development of ascent external aerothermal environments for the NASA Space Launch System (SLS) Block 1 launch vehicle for the purposes of supporting thermal analysis and the design of thermal protection systems. The SLS Block 1 Artemis I and II launch vehicles successfully launched from Pad39B at NASA Kennedy Space Center on November 16th, 2022 and April 1st, 2026, respectively. Over 70 aerothermal islands, consisting of over 265 operational instruments captured aerodynamic heating and plume induced environments throughout the launch vehicles. Gauges consisted of calorimeters, radiometers, gas temperature probes, pressure transducers, bi-directional pressure probes and thermocouples. Prior to launch, aerothermal design environment models were generated to predict ascent aerodynamic heating and plume induced environments over a design space that covered a range of vehicle trajectories that varied atmospheric, vehicle performance, and off-nominal, engine-out conditions. Post flight reconstruction models were developed for each flight island using the Day-of-Launch (DOL) Best Equivalent Trajectory (BET) that provided freestream conditions and propulsion system boundary conditions. This paper discusses a summary of the ascent aerothermal environments observed during the flights and the respective modelling approaches and the performance of them through comparisons of flight data and predictions.

aerothermodynamics

Thin Film Sensors for Fission Surface Power

Physical sensors fabricated with thin films could result a significant savings in space and weight with improved reliability for monitoring the long-term operation of fission surface power systems. Thin film sensors of 1 µm or less are attractive for FSP applications because they can be incorporated onto component surfaces with minimal machining and the additional weight to a system is minimal compared to thick film-, wire-, or foil-based sensors. The thin, surface fabrication of the sensors is also expected to make them less susceptible to deep dose effects that affect thicker sensors. An overview of thin film sensors using thermocouples and resistive elements designed, fabricated, and demonstrated at GRC for aerospace applications exceeding 900°C is presented.

Physical Sensors

Material Properties and Modeling of Room Temperature Vulcanizing Silicone

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive that has successfully been used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also used to bond instrumentation plugs such as temperature and pressure sensors into the heatshields. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Heating RTV has also shown swelling, or intumescence, which can pose unique problems that lead to roughness induced boundary-layer transition, surface oxide formation and contamination of heat shield sensors. Therefore, it is crucial to understand and model the intumescence phenomenon of RTV. As data for RTV material properties is limited, the first step in modeling RTV is to collect material properties such as pyrolysis mass-loss, microstructure change, virgin and char porosity, etc. which was performed in our initial study. Additionally, thermomechanical properties such as Young’s modulus and Poisson ratio are required for modeling the intumescence of RTV, which were taken from literature and the coefficient of thermal expansion was collected using in-situ heating and Micro Computed Tomography (µ-CT) in previous studies. Finally, numerous other properties such as pyrolysis gas properties, virgin and char thermal conductivity and specific heat were compiled from previous experiments and literature into a material database that can be used for simulations. In Porous Material Analysis Toolbox based on OpenFOAM (PATO) [4], structural mechanics coupled with material response was used for simulating the intumescence of RTV as it is heated. However, since the permeability of the material is very low, the pyrolysis gas creates an internal pressure build-up as the material is being heated, significantly contributing to the deformation of the material. To correctly characterize this phenomenon, additional physics models were implemented into PATO's stress analysis solver, and results were compared with RTV dilatometry test data as a preliminary verification case. Future work will include experiments of RTV at the Plasmatron X facility and the in-situ heating cell with µ-CT, and improvement of simulation tools to more accurately model RTV intumescence.

PATO

Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH 2 ). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH 2 temperatures (20.3 – 24.2 K), pressures (100 – 350 kPa), and flow rates (0.010 – 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

Fuel Depot

Effect of Thermomechanical Processing on the Microstructure, Properties, and Work Behavior of a Ti50.5 Ni29.5 Pt20 High-Temperature Shape Memory Alloy

TiNiPt shape memory alloys are particularly promising for use as solid state actuators in environments up to 300 °C, due to a reasonable balance of proper ties, including acceptable work output. However, one of the challenges to commercializing a viable high-temperature shape memory alloy (HTSMA) is to establish the appropriate primary and secondary processing techniques for fabrication of the material in a required product form such as rod and wire. Consequently, a Ti 50.5 Ni 29.5 Pt 20 alloy was processed using several techniques including single- pass high-temperature extrusion, multiple-pass high-temperature extrusion, and cold drawing to produce bar stock, thin rod, and fine wire, respectively. The effects of heat treatment on the hardness, grain size, room temperature tensile properties, and transformation temperatures of hot- and cold-worked material were examined. Basic tensile properties as a function of temperature and the strain-temperature response of the alloy under constant load, for the determination of work output, were also investigated for various forms of the Ti 50.5 Ni 29.5 Pt 20 alloy, including fine wire.

Grain Size